• Title/Summary/Keyword: follow up

Search Result 12,322, Processing Time 0.035 seconds

A Study on Factors Affecting BigData Acceptance Intention of Agricultural Enterprises (농업 관련 기업의 빅데이터 수용 의도에 미치는 영향요인 연구)

  • Ryu, GaHyun;Heo, Chul-Moo
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.17 no.1
    • /
    • pp.157-175
    • /
    • 2022
  • At this moment, a paradigm shift is taking place across all sectors of society for the transition movements to the digital economy. Various movements are taking place in the global agricultural industry to achieve innovative growth using big data which is a key resource of the 4th industrial revolution. Although the government is making various attempts to promote the use of big data, the movement of the agricultural industry as a key player in the use of big data, is still insufficient. Therefore, in this study, effects of performance expectations, effort expectations, social impact, facilitation conditions, based on the Unified Theory of Acceptance and Use of Technology(UTAUT), and innovation tendencies on the acceptance intention of big data were analyzed using the economic and practical benefits that can be obtained from the use of big data for agricultural-related companies as moderating variables. 333 questionnaires collected from agricultural-related companies were used for empirical analysis. The analysis results using SPSS v22.0 and Process macro v3.4 were found to have a significant positive (+) effect on the intention to accept big data by effort expectations, social impact, facilitation conditions, and innovation tendencies. However, it was found that the effect of performance expectations on acceptance intention was insignificant, with social impact having the greatest influence on acceptance intention and innovation tendency the least. Moderating effects of economic benefit and practical benefit between effort expectation and acceptance intention, moderating effect of practical benefit between social impact and acceptance intention, and moderating effect of economic benefit and practical benefit between facilitation condition and acceptance intention were found to be significant. On the other hand, it was found that economic benefits and practical benefits did not moderate the magnitude of the influence of performance expectations and innovation tendency on acceptance intention. These results suggest the following implications. First, in order to promote the use of big data by companies, the government needs to establish a policy to support the use of big data tailored to companies. Significant results can only be achieved when corporate members form a correct understanding and consensus on the use of big data. Second, it is necessary to establish and implement a platform specialized for agricultural data which can support standardized linkage between diverse agricultural big data, and support for a unified path for data access. Building such a platform will be able to advance the industry by forming an independent cooperative relationship between companies. Finally, the limitations of this study and follow-up tasks are presented.

Factors Influencing the Social and Economic Performance of High-Tech Social Ventures (하이테크 소셜벤처의 사회적·경제적성과에 미치는 영향요인)

  • Kim, Hyeong Min;Kim, Jin Soo
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.17 no.1
    • /
    • pp.121-137
    • /
    • 2022
  • The purpose of this study is to present the necessary success factors and strategies for high-tech social ventures and stakeholders in the related ecosystem by empirically identifying factors that affect their sustainable performance. Based on prior research, the dimensions of three performance factors were presented: core technology competency, core business competency, and social mission orientation. Then, such sub-dimensions such as technology innovation orientation, R&D capability, business model, customer orientation, social network, and social mission pursuit were derived. For empirical analysis, a survey was conducted on domestic high-tech social ventures, and the significance of the hypothesis was tested through PLS-structural equation analysis of the collected 243 valid data. As a result, it was found that the technology innovation orientation was embedded as an abstract organizational and cultural characteristic in the high-tech social venture, which is a research sample, and thus did not significantly affect the dependent variable. In other words, aiming for the latest cutting-edge technology alone cannot affect performance, and it is a result of proving the need for substantial influencing factors that can strengthen it. On the other hand, the business model had a significant effect only on social performance, which is presumed to be the limitation of measurement tools developed for social enterprises, and the results of additional multi-group analysis to determine the cause also supported the basis for this estimation. Excluding the previous two performance factors, R&D competency, customer orientation, social network, and social mission pursuit were all found to have a significant positive (+) effect on social and economic performance. This study laid a foundation for related research by identifying high-tech social ventures emerging in the ecosystem of a social economy and expanded empirical research models related to the performance of existing social enterprises and social ventures. However, in the research method or process, there were limitations such as factor derivation or verification for balance of dual performance, subjective measurement method, and sample representativeness. It is expected that more in-depth follow-up studies will continue by supplementing future limitations and designing improved research models.

2021 Korean Thyroid Imaging Reporting and Data System and Imaging-Based Management of Thyroid Nodules: Korean Society of Thyroid Radiology Consensus Statement and Recommendations

  • Eun Ju Ha;Sae Rom Chung;Dong Gyu Na;Hye Shin Ahn;Jin Chung;Ji Ye Lee;Jeong Seon Park;Roh-Eul Yoo;Jung Hwan Baek;Sun Mi Baek;Seong Whi Cho;Yoon Jung Choi;Soo Yeon Hahn;So Lyung Jung;Ji-hoon Kim;Seul Kee Kim;Soo Jin Kim;Chang Yoon Lee;Ho Kyu Lee;Jeong Hyun Lee;Young Hen Lee;Hyun Kyung Lim;Jung Hee Shin;Jung Suk Sim;Jin Young Sung;Jung Hyun Yoon;Miyoung Choi
    • Korean Journal of Radiology
    • /
    • v.22 no.12
    • /
    • pp.2094-2123
    • /
    • 2021
  • Incidental thyroid nodules are commonly detected on ultrasonography (US). This has contributed to the rapidly rising incidence of low-risk papillary thyroid carcinoma over the last 20 years. The appropriate diagnosis and management of these patients is based on the risk factors related to the patients as well as the thyroid nodules. The Korean Society of Thyroid Radiology (KSThR) published consensus recommendations for US-based management of thyroid nodules in 2011 and revised them in 2016. These guidelines have been used as the standard guidelines in Korea. However, recent advances in the diagnosis and management of thyroid nodules have necessitated the revision of the original recommendations. The task force of the KSThR has revised the Korean Thyroid Imaging Reporting and Data System and recommendations for US lexicon, biopsy criteria, US criteria of extrathyroidal extension, optimal thyroid computed tomography protocol, and US follow-up of thyroid nodules before and after biopsy. The biopsy criteria were revised to reduce unnecessary biopsies for benign nodules while maintaining an appropriate sensitivity for the detection of malignant tumors in small (1-2 cm) thyroid nodules. The goal of these recommendations is to provide the optimal scientific evidence and expert opinion consensus regarding US-based diagnosis and management of thyroid nodules.

Diagnostic Value of CYFRA 21-1 Measurement in Fine-Needle Aspiration Washouts for Detection of Axillary Recurrence in Postoperative Breast Cancer Patients (유방암 수술 후 액와림프절 재발 진단에 있어서의 미세침세척액 CYFRA 21-1의 진단적 가치)

  • So Yeon Won;Eun-Kyung Kim;Hee Jung Moon;Jung Hyun Yoon;Vivian Youngjean Park;Min Jung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.147-156
    • /
    • 2020
  • Purpose The objective of this study was to evaluate the diagnostic value and threshold levels of cytokeratin fragment 21-1 (CYFRA 21-1) in fine-needle aspiration (FNA) washouts for detection of lymph node (LN) recurrence in postoperative breast cancer patients. Materials and Methods FNA cytological assessments and CYFRA 21-1 measurement in FNA washouts were performed for 64 axillary LNs suspicious for recurrence in 64 post-operative breast cancer patients. Final diagnosis was made on the basis of FNA cytology and follow-up data over at least 2 years. The concentration of CYFRA 21-1 was compared between recurrent LNs and benign LNs. Diagnostic performance and cut-off value were evaluated using a receiver operating characteristic curve. Results Regardless of the non-diagnostic results, the median concentration of CYFRA 21-1 in recurrent LNs was significantly higher than that in benign LNs (p < 0.001). The optimal diagnostic cut-off value was 1.6 ng/mL. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CYFRA 21-1 for LN recurrence were 90.9%, 100%, 100%, 98.1%, and 98.4%, respectively. Conclusion Measurement of CYFRA 21-1 concentration from ultrasound-guided FNA biopsy aspirates showed excellent diagnostic performance with a cut-off value of 1.6 ng/mL. These results indicate that measurement of CYFRA 21-1 concentration in FNA washouts is useful for the diagnosis of axillary LN recurrence in post-operative breast cancer patients.

Comparison of Radiation Dose and Image Quality between the 2nd Generation and 3rd Generation DualSource Single-Energy and Dual-Source Dual-Energy CT of the Abdomen (2세대와 3세대 이중 소스 단일 에너지와 이중 소스 이중 에너지를 이용한 복부 컴퓨터단층촬영의 방사선량 및 영상 품질 비교)

  • Chang Gun Kim;See Hyung Kim;Seung Hyun Cho;Hun kyu Ryeom;Won Hwa Kim;Hye Jung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1342-1353
    • /
    • 2022
  • Purpose We compared the radiation dose and image quality between the 2nd generation and the 3rd generation dual-source single-energy (DSSE) and dual-source dual-energy (DSDE) CT of the abdomen. Materials and Methods We included patients undergoing follow-up abdominal CT after partial or radical nephrectomy in the first 10 months of 2019 (2nd generation DS CT) and the first 10 months of 2020 (3rd generation DS CT). We divided the 320 patients into 4 groups (A, 2nd generation DSSE CT; B, 2nd generation DSDE CT; C, 3rd generation DSSE CT; and D, 3rd generation DSDE CT) (n = 80 each) matched by sex and body mass index. Radiation dose and image quality (objective and subjective qualities) were compared between the groups. Results The mean size-specific dose estimation of 3rd generation DSDE CT group was significantly lower than that of the 2nd generation DSSE CT (42.5%, p = 0.013) and 2nd generation DSDE CT (46.9%, p = 0.015) groups. Interobserver agreement was excellent for the overall image quality (intraclass correlation coefficient [ICC]: 0.8867) and image artifacts (ICC: 0.9423). Conclusion Our results showed a considerable reduction in the radiation dose while maintaining high image quality with 3rd generation DSDE CT as compared to the 2nd generation DSDE CT and 2nd generation DSSE CT.

Efficacy and Safety of a Newly Developed Self-Expanding Open-Cell Type Nitinol Stent for Peripheral Arteries: A Preclinical Study in Minipigs (새로 개발된 말초동맥용 자가팽창성 개방형 니티놀 스텐트의 유효성 및 안전성 평가: 미니피그 전임상실험)

  • Min Uk Kim;Jae Hwan Lee;Chang Jin Yoon;Won Seok Choi;Saebeom Hur;Jin Wook Chung
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.4
    • /
    • pp.899-911
    • /
    • 2020
  • Purpose To evaluate the safety and efficacy of the newly designed open-cell type self-expandable nitinol stent (NiTi-stent) for peripheral arteries. Materials and Methods Twenty-eight limbs of 14 minipigs were randomly assigned to the NiTistent group or conventional nitinol stent group. Stents were symmetrically implanted into the iliac arteries of each animal using carotid artery approach and were observed for 1 month (n = 5) and 6 months (n = 9). The angiographic lumen diameter (ALD), late lumen loss, angiographic stenosis, histomorphometric lumen area, neointimal area, and area stenosis were analyzed and compared between the groups. Results Stent migration, stent fracture, or thrombus formation were not observed in either group. At the 1-month follow-up, the neointimal area (p = 0.008) and area stenosis (p = 0.016) were significantly smaller in the NiTi-stent group than in the control group. At the 6-months followup, the NiTi-stent group showed significantly larger ALD (p = 0.014), less late lumen loss (p = 0.019), less angiographic stenosis (p = 0.014), larger lumen area (p = 0.040), and smaller neointimal area and area stenosis (p = 0.004 and p = 0.014, respectively) compared with the control group. Conclusion The NiTi-stent is as safe and effective as the conventional nitinol stent and induces less neointimal hyperplasia in a minipig iliac artery model.

Safety and Efficacy of Ultrasound-Guided Percutaneous Core Needle Biopsy of Pancreatic and Peripancreatic Lesions Adjacent to Critical Vessels (주요 혈관 근처의 췌장 또는 췌장 주위 병변에 대한 초음파 유도하 경피적 중심 바늘 생검의 안전성과 효율성)

  • Sun Hwa Chung;Hyun Ji Kang;Hyo Jeong Lee;Jin Sil Kim;Jeong Kyong Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1207-1217
    • /
    • 2021
  • Purpose To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy (USPCB) of pancreatic and peripancreatic lesions adjacent to critical vessels. Materials and Methods Data were collected retrospectively from 162 patients who underwent USPCB of the pancreas (n = 98), the peripancreatic area adjacent to the portal vein, the paraaortic area adjacent to pancreatic uncinate (n = 34), and lesions on the third duodenal portion (n = 30) during a 10-year period. An automated biopsy gun with an 18-gauge needle was used for biopsies under US guidance. The USPCB results were compared with those of the final follow-up imaging performed postoperatively. The diagnostic accuracy and major complication rate of the USPCB were calculated. Multiple factors were evaluated for the prediction of successful biopsies using univariate and multivariate analyses. Results The histopathologic diagnosis from USPCB was correct in 149 (92%) patients. The major complication rate was 3%. Four cases of mesenteric hematomas and one intramural hematoma of the duodenum occurred during the study period. The following factors were significantly associated with successful biopsies: a transmesenteric biopsy route rather than a transgastric or transenteric route; good visualization of targets; and evaluation of the entire US pathway. In addition, the number of biopsies required was less when the biopsy was successful. Conclusion USPCB demonstrated high diagnostic accuracy and a low complication rate for the histopathologic diagnosis of pancreatic and peripancreatic lesions adjacent to critical vessels.

Light-Chain Cardiac Amyloidosis: Cardiac Magnetic Resonance for Assessing Response to Chemotherapy

  • Yubo Guo;Xiao Li;Yajuan Gao;Kaini Shen;Lu Lin;Jian Wang;Jian Cao;Zhuoli Zhang;Ke Wan;Xi Yang Zhou;Yucheng Chen;Long Jiang Zhang;Jian Li;Yining Wang
    • Korean Journal of Radiology
    • /
    • v.25 no.5
    • /
    • pp.426-437
    • /
    • 2024
  • Objective: Cardiac magnetic resonance (CMR) is a diagnostic tool that provides precise and reproducible information about cardiac structure, function, and tissue characterization, aiding in the monitoring of chemotherapy response in patients with light-chain cardiac amyloidosis (AL-CA). This study aimed to evaluate the feasibility of CMR in monitoring responses to chemotherapy in patients with AL-CA. Materials and Methods: In this prospective study, we enrolled 111 patients with AL-CA (50.5% male; median age, 54 [interquartile range, 49-63] years). Patients underwent longitudinal monitoring using biomarkers and CMR imaging. At follow-up after chemotherapy, patients were categorized into superior and inferior response groups based on their hematological and cardiac laboratory responses to chemotherapy. Changes in CMR findings across therapies and differences between response groups were analyzed. Results: Following chemotherapy (before vs. after), there were significant increases in myocardial T2 (43.6 ± 3.5 ms vs. 44.6 ± 4.1 ms; P = 0.008), recovery in right ventricular (RV) longitudinal strain (median of -9.6% vs. -11.7%; P = 0.031), and decrease in RV extracellular volume fraction (ECV) (median of 53.9% vs. 51.6%; P = 0.048). These changes were more pronounced in the superior-response group. Patients with superior cardiac laboratory response showed significantly greater reductions in RV ECV (-2.9% [interquartile range, -8.7%-1.1%] vs. 1.7% [-5.5%-7.1%]; P = 0.017) and left ventricular ECV (-2.0% [-6.0%-1.3%] vs. 2.0% [-3.0%-5.0%]; P = 0.01) compared with those with inferior response. Conclusion: Cardiac amyloid deposition can regress following chemotherapy in patients with AL-CA, particularly showing more prominent regression, possibly earlier, in the RV. CMR emerges as an effective tool for monitoring associated tissue characteristics and ventricular functional recovery in patients with AL-CA undergoing chemotherapy, thereby supporting its utility in treatment response assessment.

Single Center Experience of the Balloon-Stent Technique for the Treatment of Unruptured Distal Internal Carotid Artery Aneurysms: Sharing a Simple and Reliable Tip to Use Scepter-Atlas Combination (원위내경동맥에 위치한 비파열성 동맥류의 치료에 있어 풍선-스텐트 테크닉에 대한 단일기관의 경험: Scepter-Atlas 조합을 사용하기 위한 간단하지만 확실한 방법)

  • Yu-jung Park;Jieun Roh;Seung Kug Baik;Jeong A Yeom;Chul-Hoo Kang;Hee Seok Jeong;Sang Won Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1258-1273
    • /
    • 2021
  • Purpose The balloon-stent technique (BST) has certain strengths as an assisted technique for the treatment of complex aneurysms. After Atlas release, the BST can be executed without an exchange maneuver of the balloon to the stent-delivery catheter. The purpose of this article is to share our experience with the BST using the Scepter-Atlas combination. Materials and Methods Device inspection led us to a simple method to avoid failure in loading Atlas to the Scepter. From March 2018 to December 2019, 57 unruptured distal internal carotid artery (dICA) aneurysms were treated with coil embolization; among which, 25 aneurysms in 23 patients were treated with BST. Clinical and angiographic data were retrospectively collected and reviewed. Results The technical success rate of the Scepter-Atlas combination increased from 50% to 100% after careful inspection. BST angiographic results were comparable to the stent-assisted coil (SAC) group treated during the immediately post-embolization same period (modified Raymond-Roy classification [MRRC] 1 & 2 84% in BST, 96.3% in SAC) and during short-term follow-up (MRRC 1 & 2 95.8% in BST, 88.4% in SAC). A small number of patients showed periprocedural complications, but none had clinical consequences. Conclusion BST using the Scepter-Atlas combination can provide an effective and safe method for the treatment of dICA aneurysms. Scepters can be used as delivery catheters for Atlas.

First-Pass Recanalization with EmboTrap II in Acute Ischemic Stroke (FREE-AIS): A Multicenter Prospective Study

  • Jang-Hyun Baek;Byung Moon Kim;Sang Hyun Suh;Hong-Jun Jeon;Eun Hyun Ihm;Hyungjong Park;Chang-Hyun Kim;Sang-Hoon Cha;Chi-Hoon Choi;Kyung Sik Yi;Jun-Hwee Kim;Sangil Suh;Byungjun Kim;Yoonkyung Chang;So Yeon Kim;Jae Sang Oh;Ji Hoe Heo;Dong Joon Kim;Hyo Suk Nam;Young Dae Kim
    • Korean Journal of Radiology
    • /
    • v.24 no.2
    • /
    • pp.145-154
    • /
    • 2023
  • Objective: We aimed to evaluate the efficacy of EmboTrap II in terms of first-pass recanalization and to determine whether it could yield favorable outcomes. Materials and Methods: In this multicenter, prospective study, we consecutively enrolled patients who underwent mechanical thrombectomy using EmboTrap II as a front-line device. The primary outcome was the first pass effect (FPE) rate defined by modified Thrombolysis In Cerebral Infarction (mTICI) grade 2c or 3 by the first pass of EmboTrap II. In addition, modified FPE (mFPE; mTICI grade 2b-3 by the first pass of EmboTrap II), successful recanalization (final mTICI grade 2b-3), and clinical outcomes were assessed. We also analyzed the effect of FPE on a modified Rankin Scale (mRS) score of 0-2 at 3 months. Results: Two hundred-ten patients (mean age ± standard deviation, 73.3 ± 11.4 years; male, 55.7%) were included. Ninety-nine patients (47.1%) had FPE, and mFPE was achieved in 150 (71.4%) patients. Successful recanalization was achieved in 191 (91.0%) patients. Among them, 164 (85.9%) patients underwent successful recanalization by exclusively using EmboTrap II. The time from groin puncture to FPE was 25.0 minutes (interquartile range, 17.0-35.0 minutes). Procedure-related complications were observed in seven (3.3%) patients. Symptomatic intracranial hemorrhage developed in 14 (6.7%) patients. One hundred twenty-three (58.9% of 209 completely followed) patients had an mRS score of 0-2. Sixteen (7.7% of 209) patients died during the follow-up period. Patients who had successful recanalization with FPE were four times more likely to have an mRS score of 0-2 than those who had successful recanalization without FPE (adjusted odds ratio, 4.13; 95% confidence interval, 1.59-10.8; p = 0.004). Conclusion: Mechanical thrombectomy using the front-line EmboTrap II is effective and safe. In particular, FPE rates were high. Achieving FPE was important for an mRS score of 0-2, even in patients with successful recanalization.