• Title/Summary/Keyword: flux recovery rate

Search Result 62, Processing Time 0.021 seconds

A Study on the Opimization of Process and Operation Condition for Membrane System in Tap Water Treatment (분리막을 이용한 정수처리 System에서 처리공정 및 운전조건의 최적화에 관한연구)

  • 오중교
    • Membrane Journal
    • /
    • v.9 no.4
    • /
    • pp.193-201
    • /
    • 1999
  • The object of study were the development of membrane process and the optimization of operation condition for membrane system, which was used the pre-treatment system of tap water treatment in steady of conventional process such as coagulation, sedimentation. The higher steady flux is very important factor, by a suitable pre-treatment and optimization of operating condition such as fouling control, crossflow and backwashing method, in membrane system. So, we were observed the effect of flux decline for membrane used by 4 type ultrafiltration(UF) membrane pre-treatment process, and optimized the operation condition of filtration system under various MWCO(Molecular weight cut-off), operation pressure, linear velocity and temperature to maintain higher flux. From these experiment, we were identified that UF process showed a slower flux decline rate and a higher flux recovery than microfiltration(MF) membrane. The water quality of UF permeate was better than that of MF, and was not effected pre-treatment process. In the operation condition, the rate of flux decline was diminished by a higher linear velocity and operation temperature, lower pressure.

  • PDF

Analysis of thermal energy efficiency for hollow fiber membranes in direct contact membrane distillation

  • Park, Youngkyu;Lee, Sangho
    • Environmental Engineering Research
    • /
    • v.24 no.2
    • /
    • pp.347-353
    • /
    • 2019
  • Although membrane distillation (MD) has great promise for desalination of saline water sources, it is crucial to improve its thermal efficiency to reduce the operating cost. Accordingly, this study intended to examine the thermal energy efficiency of MD modules in a pilot scale system. Two different modules of hollow fiber membranes were compared in direct contact MD mode. One of them was made of polypropylene with the effective membrane area of $2.6m^2$ and the other was made of polyvinylidene fluoride with the effective membrane area of $7.6m^2$. The influence of operation parameters, including the temperatures of feed and distillate, feed flow rate, and distillate flow rate on the flux, recovery, and performance ratio (PR), was investigated. Results showed that the two MD membranes showed different flux and PR values even under similar conditions. Moreover, both flow rate and temperature difference between feed and distillate significantly affect the PR values. These results suggest that the operating conditions for MD should be determined by considering the module properties.

Recovery of Levafix brilliant red E-4BA and Levafix brilliant red E-6BA from aqueous solution by supported liquid membrane

  • Muthuraman, G.;Sathya, M.;Soniya, M.;Elumalai, S.
    • Membrane and Water Treatment
    • /
    • v.4 no.4
    • /
    • pp.277-291
    • /
    • 2013
  • The transport and recovery of Levafix brilliant red E-4BA and Levafix brilliant red E-6BA were investigated using polytetrafluoroethylene (PTFE) fiber based supported liquid membrane containing tetra butyl ammonium bromide (TBAB) in coconut oil as a carrier. The influencing parameters studied are: pH of the feed solution, concentration of dye in the feed solution, extractant concentration, and various kind of stripping agent, rate of stirring, time of transport, reusability of membrane and stability of membrane. Increase in TBAB concentration inside the membrane enhances the flux with its maximum value at $1.553{\times}10^{-4}$ M TBAB. Further increase in the concentration of TBAB leads to decreased rate of transport due to increase in viscosity of membrane liquid. The optimum conditions for dye transport are: pH of feed ($7{\pm}0.1$), $1.553{\times}10^{-4}$ M extractant concentration, 350 rpm for stirring, $4.9{\times}10^{-1}$ M potassium hydrogen phthalate as a stripping solution, the time of transport 6 h. It was noticed that flux values were increased with increasing dye concentration in the feed phase. Applying this study to textile wastewater, dyes were transported up to 98% in 6 h. This recovery technique is rewarding to environment and economic.

Recovery of Nitric Acid from Waste Solder Stripper by Diffusion Dialysis (폐솔더 박리액으로부터 확산투석법에 의한 질산의 회수)

  • Ryu, Seong-Hyung;Kim, Tae-Young;Ahn, Nak-Kyoon;Gang, Myeong-Sik;Ahn, Jae-Woo;Ahn, Jong-Gwan
    • Resources Recycling
    • /
    • v.24 no.5
    • /
    • pp.33-39
    • /
    • 2015
  • A basic study was conducted to effectively recover nitric acid from a waste solder stripper by diffusion dialysis using anion exchange membranes. The effects of flow rate, flux ratio, nitrate concentration, and metallic ion types and concentration on the recovery percentage of nitric acid were investigated. The recovery percentage of nitric acid was decreased with the increase of flow velocity. But the recovery percentage of nitric acid was increased as the increase of flux ratio(W/F) and showing a recovery percentage of nitric acid of about 99% at a flux ratio of 1.5 or more. As the increase of nitric acid concentration in feed solution, the recovery percentage of nitric acid was increased up to 3.0M, but in case of greater than 3.0M, the recovery percentage gradually was decreased. Leakage percentage of metallic ions through the membrane were in the order of Pb, Na and Cu but Fe and Sn did not leakaged. As a result of diffusion dialysis using real waste solder stripper at a flow rate of $0.9L/hr-m^2$, W/F = 1.3, a recovery percentage of nitric acid of approximately 94% was gained.

Evaluation of High Flux Combined with Pretreatment Process for Application of Decentralized Water Supply System with Ceramic Membrane (세라믹 분리막의 분산형 용수공급 시스템 적용을 위한 전처리 연계공정의 고플럭스 평가)

  • Kang, Joon-Seok;Park, Seo Gyeong;Lee, Jeong Eun;Kang, So Yeon;Lee, Jeong Jun;Quyen, Vo Thi Kim;Kim, Seongsu;Kim, Han-Seung
    • Journal of Korean Society of Water Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.61-72
    • /
    • 2018
  • In this study, applicability of the decentralized water supply system were investigated by the high flux evaluation using ceramic membrane with combined pretreatment process. A) filtration process increased the transmembrane pressure of 1.4 kPa and 89.5 kPa on 2 and $5m^3/m^2{\cdot}d$ of filtration flux, respectively, the physical backwashing recovery rate were less than 28.6%. The (B) Coag./Floc. - Sedi. combined process with 4 mg / L of A-PAC showed that the transmembrane pressure increased to within 6 kPa, the physical backwashing recovery rate was over 37.9 % higher than (A) Filtration process. (C) Coag./Floc. combined process showed an increase of transmembrane pressure compared with (B) Coag./Floc. - Sedi. combined process, physical backwashing recovery rate was over 84%. As a result of the membrane fouling analysis using the resistance in series model, the combined pretreatment process showed that the cake resistance (Rc) was more than 92% at membrane filtration flux of $2m^3/m^2{\cdot}d$. In the (C) Coag./Floc. combined process, cake resistance(Rc) was over 86% on high flux conditions. The coagulation floc contained in influent was removed by the membrane, and the cake layer formed with the removed floc was identified as reversible fouling resistance which could be recovered by physical backwashing. The decentralized water supply system, which has the limitation of site area and installation space, is considered to could be operation of high flux of ceramic membrane by applying (C) Coag./Floc. combined process without sedimentation process.

The Degumming and Sericin Recovery of the Silk fabric Using the Electrolytic Water(II) (전해수를 이용한 견섬유 정련 및 세리신 회수(II)-분리막에 의한 세리신 농축을 중심으로-)

  • 배기서;이태상;노덕길;홍영기
    • Textile Coloration and Finishing
    • /
    • v.16 no.4
    • /
    • pp.10-18
    • /
    • 2004
  • In this work, Aqueous sericin solution was prepared by degumming process with electrolytic reduction water. Then, the microfiltration and ultrafiltration systems were applied to the concentration of aqueous sericin solution. The objective of this study was to select the optimum operating condition among the different pressure. The permeate flux and rejection ratio were observed with time, pressure, flow rate and concentration. and, the wastewater and permeated water quality values such as pH, BOD, COD, and NH levels were measured. In order to see the influence of electrolytic reduction water, the flux of pure water and electrolytic reduction water by PVDF22(MF) and PS100(UF) membrane was measured. In microfiltration system, the relative flux reduction decreased rapidly to 0.02 in the 30min, as the concentration polarization and gel layer formation were increased. and then the sericin concentration rejection ratio was 40%. In ultrafiltration system, the permeate flux decreased with time and concentration, and increased with the operating pressure and flow rate. Optimal condition in PS100 membrane system for sericin concentration was operating pressure 1.464kgf/$cm^24, operating flow rate $7\ell/min at\; 40^{\circ}C$. At that time, sericin concentration rejection ratio was 83% respectably. The sericin solution was concentrated from 0.1wt% solution to 0.2 wt % solution during about 2 hrs by the UF filteration membrane system.

Evaluation of the efficiency of cleaning method in direct contact membrane distillation of digested livestock wastewater

  • Kim, Sewoon;Park, Ki Young;Cho, Jinwoo
    • Membrane and Water Treatment
    • /
    • v.8 no.2
    • /
    • pp.113-123
    • /
    • 2017
  • This study investigated effects of physical and chemical cleaning methods on the initial flux recovery of fouled membrane in membrane distillation process. A laboratory scale direct contact membrane distillation (DCMD) experiment was performed to treat digested livestock wastewater with 3.89 mg/L suspended solids, 874.7 mg/L COD, 543.7 mg/L nitrogen, 15.6 mg/L total phosphorus, and pH of 8.6. A hydrophobic PVDF membrane with an average pore size of $0.22{\mu}m$ and a porosity of 75 % was installed inside a direct contact type membrane distillation module. The temperature difference between feed and permeate side was maintained at $40^{\circ}C$ with the feed and permeate stream velocity of 0.18 m/s. The results showed that the permeate flux decreased from $22.1L{\cdot}m^{-2}{\cdot}hr^{-1}$ to $19.0L{\cdot}m^{-2}{\cdot}hr^{-1}$ after 75 hours of distillation. The fouled membrane was cleaned first by physical flushing and consecutively by chemicals with NaOCl and citric acid. After the physical cleaning the flux was recovered to 92 % as compared with the initial clean water flux of the virgin membrane. Then 94 % of the flux was recovered after cleaning by 2,000 ppm NaOCl for 90 minutes and finally 97 % of flux recovered after 3 % citric acid for 90 minutes. SEM-EDS and FT-IR analysis results presented that the foulants on the membrane surface were removed effectively after each cleaning step. The contact angle measurement showed that the hydrophobicity of the membrane surface was also restored gradually after each cleaning step to reach nearly the same hydrophobicity level as the virgin membrane.

Studies on the Efficient Concentration Process of Apple Juice with Reverse Osmosis Process (역삼투막 공정을 이용한 사과쥬스의 효율적인 농축공정에 관한 연구)

  • Hur, Sang-Sun;Choi, Yong-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.321-326
    • /
    • 1993
  • Membrane separation technology with polymeric membranes for the effective separation and energy conservation has emerged to be a new technology for separation in recent years. In this research, the reverse osmosis process was applied to the concentration process of clarified apple juices. The changes of concentration and permeate flux of apple juice in this process were measured at different membrane characteristics, operating pressures, temperature and flow rate. And the changes of quality were also measured at different pressures. The prediction model for the permeate flux based on these data was established. Generally, the osmotic pressure increased as the concentration of the feed increased in the RO process, which caused a reduction of permeate flux. The changes of permeate flux were not much dependent on temperature and flow rate, but very much dependent on pressure. The most effective factor in increased permeate flux was found to be the operating pressure, followed by temperature and flow rate. The final prediction model for the permeate flux was developed by the $SPSS^x$ computer program. The result showed that recovery of sugar was not affected by processing pressures, but the percentage recovery of total flavor was increased with increasing pressure.

  • PDF

The Evaluation of Fouling Mechanism on Cross Flow Precoagulation-UF Process (십자형 응집-UF 막분리 공정 적용시 전처리 응집조건에 따른 막오염 메카니즘 규명)

  • Jung, Chul-Woo;Son, Hee-Jong
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.639-645
    • /
    • 2008
  • The objectives of this research are to (1) observe changes in particle size distribution due to formation of microflocs during coagulation process (2) identify the membrane fouling potential on cross flow system (3) investigate the mechanism of membrane fouling. The rate of flux decline for the hydrophobic membrane was significantly greater than for the hydrophilic membrane, regardless of pretreatment conditions. The pretreatment of the raw water significantly reduced the fouling of the UF membrane. Also, the rate of flux decline for the hydrophobic membrane was considerably greater than for the hydrophilic membrane. Applying coagulation process before membrane filtration showed not only reducing membrane fouling, but also improving the removal of dissolved organic materials that might otherwise not be removed by the membrane. That is, during the mixing period, substantial changes in particle size distribution occurred under rapid and slow mixing condition due to the simultaneous formation of microflocs and NOM precipitates. Therefore, combined pretreatment using coagulation not only improved dissolved organics removal efficiency but also flux recovery efficiency.

Surface properties and interception behaviors of GO-TiO2 modified PVDF hollow fiber membrane

  • Li, Dongmei;Liang, Jinling;Huang, Mingzhu;Huang, Jun;Feng, Li;Li, Shaoxiu;Zhan, Yongshi
    • Membrane and Water Treatment
    • /
    • v.10 no.2
    • /
    • pp.113-120
    • /
    • 2019
  • To investigate surface properties and interception performances of the new modified PVDF membrane coated with Graphene Oxide (GO) and nano-$TiO_2$ (for short the modified membrane) via the interface polymerization method combined with the pumping suction filtration way, filtration experiments of the modified membrane on Humic Acid (HA) were conducted. Results showed that the contact angle (characterizing the hydrophilicity) of the modified membrane decreased from $80.6{\pm}1.8^{\circ}$ to $38.6{\pm}1.2^{\circ}$. The F element of PVDF membrane surface decreased from 60.91% to 17.79% after covered with GO and $TiO_2$. O/C element mass ratio has a fivefold increase, the percentage of O element on the modified membrane surface increased from 3.83 wt% to 20.87%. The modified membrane surface was packed with hydrophilic polar groups (like -COOH, -OH, C-O, C=O, N-H) and a functional hydrophilic GO-polyamide-$TiO_2$ composite configuration. This configuration provided a rigid network structure for the firm attachment of GO and $TiO_2$ on the surface of the membrane and for a higher flux as well. The total flux attenuation rate of the modified membrane decreased to 35.6% while 51.2% for the original one. The irreversible attenuation rate has dropped 71%. The static interception amount of HA on the modified membrane was $158.6mg/m^2$, a half of that of the original one ($295.0mg/m^2$). The flux recovery rate was increased by 50%. The interception rate of the modified membrane on HA increased by 12% approximately and its filtration cycle was 2-3 times of that of the original membrane.