• 제목/요약/키워드: flux noise

검색결과 261건 처리시간 0.02초

누설자속 탐상법 및 노이즈 필터를 이용한 와이어로프의 결함진단시스템 개발 (A Development of the Fault Detection System of Wire Rope using Magnetic Flux Leakage Inspection Method and Noise Filter)

  • 이영진;아미나;이권순
    • 전기학회논문지
    • /
    • 제63권3호
    • /
    • pp.418-424
    • /
    • 2014
  • A large number of wire rope has been used in various industries such as cranes and elevators. When wire used for a long time, wire defects occur such as disconnection and wear. It leads to an accident and damage to life and property. To prevent this accident, we proposed a wire rope fault detection system in this paper. We constructed the whole system choosing the leakage fault detection method using hall sensors and the method is simple and easy maintenance characteristics. Fault diagnosis and analysis were available through analog filter and amplification process. The amplified signal is transmitted to the computer through the data acquisition system. This signal could be obtained improved results through the digital filter process.

The Iron loss Estimation of IPMSM According to Current Phase Angle

  • Cho, Gyu-Won;Kim, Dong-Yeong;Kim, Gyu-Tak
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1345-1351
    • /
    • 2013
  • Variable iron loss as function of current phase angle of Interior Permanent Magnet Synchronous Motor(IPMSM) was calculated through Curve Fitting Method(CFM). Also, a magnetic flux density distribution of iron core according to current phase angle was analyzed, and an iron loss calculation was performed including harmonic distortion. The experiment was performed by production of non-magnetizing model for the separation of mechanical loss, and the iron loss was calculated by the measurement of input using power analyzer and output power using dynamometer. Some error was generated between experimental results and calculation value, but an iron loss diminution according to current phase angle followed a same pattern. So, errors were generated by measurement, vibration, noise, harmonic distortion loss, etc.

The Maximum Efficiency Driving in IPMSM by Precise Estimation of Current Phase Angle

  • Cho, Gyu-Won;Kim, Cheol-Min;Kim, Gyu-Tak
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권5호
    • /
    • pp.1221-1226
    • /
    • 2013
  • In this paper, the equivalent circuit for the efficiency calculation by precise estimation of the linkage flux, inductance and iron loss resistance was calculated accurately. In addition, the driving characteristics according to the current phase angle are analyzed and the maximum efficiency point is calculated. And then, analyzed and experimental values of the efficiency were compared. So, causes of error were expected to be vibration and noise by harmonic distortion of the voltage and current, and mechanical loss of dynamometer. In addition, the driving characteristics according to the current phase angle are analyzed and the maximum efficiency point is calculated.

다목적 실용위성의 궤도 결정 오차 분석 (Orbit Determination Error Analysis for the KOMPSAT)

  • 이정숙;이병선
    • Journal of Astronomy and Space Sciences
    • /
    • 제15권2호
    • /
    • pp.437-447
    • /
    • 1998
  • 한반도의 지도 제작을 주임무로 1999년에 발사될 다목적 실용위성의 궤도 오차를 GPS 항행 해와 지상 안테나의 추적 데이터를 이용하여 분석하였다. 측정 데이터의 잡음과 모델 링의 오차를 고려하여 최소 자승 방법으로 궤도 결정과 예측 오차를 시뮬레이션 하였다. 측정 데이터의 잡음은 단기간 오차의 주 요인이 되며, 태양 플럭스의 불확실성으로 인한 오차가 궤도 예측 오차에 가장 크게 작용함을 알 수 있었다.

  • PDF

단상 유도형 동기 전동기의 성능향상을 위한 고찰 (The study of single phase line start permanent magnet motor for characteristic improvement)

  • 이진헌;김승주;최승길;이주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.77-79
    • /
    • 2007
  • In previous structure of single phase LSPM, there is large torque ripple that makes a noise and a vibration by a distortion of flux distribution in air gap. By this reason, the single phase LSPM is not accepted home applications. So, in this paper, we propose new structure of single phase LSPM(Line Start Permanent magnet Motor). The proposed model is reduced a torque ripple about a half than previous model.

  • PDF

Assessment of a Phase Doppler Anemometry Technique in Dense Droplet Laden Jet

  • Koo, Ja-Ye;Kim, Jong-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • 제17권7호
    • /
    • pp.1083-1094
    • /
    • 2003
  • This study represents an assessment of the phase-Doppler technique to the measurements of dense droplet laden jet. High-pressure injection fuel sprays have been investigated to evaluate the use of the Phase-Doppler anemometry (PDA) technique. The critical issue is the stability of the phase-Doppler anemometry technique for dense droplet laden jet such as Diesel fuel spray in order to insure the results from the drop size and velocity measurements are repeatable, consistent, and physically realistic because the validation rate of experimental data is very low due to the thick optical density. The effect of shift frequency is minor, however, the photomultiplier tube (PMT) voltage setting is very sensitive to the data acquisition and noise in dense droplet laden jet. The optimum PMT voltage and shift frequency should be chosen so that the data such as volume flux and drop diameter do not change rapidly.

아트리움형 공간 내 수직온도차에 따른 온열환경 (Indoors Thermal Environment by Vertical Temperature Differences in Atrium Space)

  • 위승환;이종기;김석환;김수민
    • 한국가구학회지
    • /
    • 제25권2호
    • /
    • pp.122-128
    • /
    • 2014
  • Recently, many studies have conducted to satisfy a physical need of human between environment of light on space, so an atrium structure has been applied to cultural complex. However, this structure brings about many problems such as overheating in summer, excessive vertical temperature differences, condensation, diffusion of noise, effect of echo, and withering landscapes. Especially, in this research, thermal comfort by difference of vertical temperature in the space of atrium and the optical characteristics of glass skins of the atrium could be remarkably effected by solar flux entering indoors.

  • PDF

수도사업장 고조파 측정, 분석을 통한 관리기준 만족여부 조사 (To examine of management standard by the harmonics measured and analyzed in water supply field)

  • 홍성택;이은춘;신강욱;임재일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.296-298
    • /
    • 2003
  • At the water supply field, high voltage induction motor is main facility of a load equipment. The motor is often out of order and its noise, generated heat, loss etc occured occasionally. especially, transmission motor for flux control generates an amount of the harmonics then have a bad influence upon the electric power system. In this study, to analyze the total harmonics distortion of the water supply field receiving high voltage, the harmonics measured and analyzed using the PQA(Power Quality Analyzer) according to the electric power system and electrical load and the reduction method presented.

  • PDF

영구 자석형 선형 진동 기기의 특성 시험법에 관한 연구 (A Set of Experiments to more fully characterize PM Linear Oscillatory Machines)

  • 김명진;장기봉;이주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.22-24
    • /
    • 2005
  • This paper is intended to introduce a set of static and dynamic experiments for a better characterization of the linear permanent magnet oscillatory machine. The experiment have been peformed on two prototypes; one with buried permanent magnets with flux concentration while the other with surface permanent magnets. Though the testing arrangement allows for it, temperature, noise and vibration have not been in this paper.

  • PDF

직접 적응제어 방식을 이용한 유도전동기의 벡타제어 (A VECTOR CONTROLLER DESIGN WITH DIRCT MRAC FOR SPEED CONTROL OF INDUCTION MOTOR)

  • 임계영;장석주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(I)
    • /
    • pp.737-741
    • /
    • 1987
  • The induction motor is represented by nonlinear equations whose parameters are changing with respect to the slip-frequency, temperature, etc. The slip-frequency is effected by unknown load which is difficult to estimate on-line. Astable vector controller is designed with direct MRAC to improve the quality of the transient response. The unknown load is considered in this speed controller design, and tested by simulation. Also a flux controller is designed and tested to reduce the audible noise in this paper.

  • PDF