• Title/Summary/Keyword: flux loss

Search Result 485, Processing Time 0.031 seconds

A Study on the Measurement of Axial Cracks in the Magnetic Flux Leakage NDT System (자기누설 비파괴 검사 시스템에서 축방향 미소결함 측정에 관한 연구)

  • Kim, Hui-Min;Park, Gwan-Soo;Rho, Yong-Woo;Yoo, Hui-Ryong;Cho, Sung-Ho;Kim, Dong-Kyu;Koo, Sung-Ja
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.2
    • /
    • pp.49-57
    • /
    • 2012
  • From among the NDT (Non-Destructive Testing) methods, the MFL (Magnetic Flux Leakage) PIG (Pipeline Inspection Gauge) is especially suitable for testing pipelines because the pipeline has high magnetic permeability. MFL PIG showed high performance in detecting the metal loss and corrosions. However, MFL PIG is difficult to detect the crack which occured by exterior-interior pressure difference in pipelines and the shape of crack is very long and narrow. Therefore, the new PIG is needed to be researched and developed for detecting the cracks. The CMFL (Circumferential MF) PIG performs magnetic fields circumferentially and can maximize the magnetic flux leakage at the cracks. In this paper, CMFL PIG is designed and the distribution of the magnetic fields is analyzed by using 3 dimensional nonlinear finite element method (FEM). By Simulating and Measuring the magnetic leakage field, it is possible to detect of axial cracks in the pipeline.

Field Loss Analysis and Cooling Analysis of HTS Synchronous Motor (고온초전도 동기모터의 계자손실 해석 및 냉각 해석)

  • Kim, Ki-Chan;Lee, Dae-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.69-74
    • /
    • 2018
  • Large industrial motors require a large area because of the high risk of shutdown accidents and large industrial accidents due to the lowering of the dielectric strength of the armature windings and overheating problems. Therefore, there is a demand for a large-capacity motor that has small size, light weight, and excellent dielectric strength compared with conventional motors. Superconducting motors have advantages of high efficiency and output power, low size, low weight, and improved stability. This results from greatly increasing the magnetic field generation by using superconductive field coils in rotating machines such as generators and motors. It is very important to design and analyze the cooling system to lower the critical temperature of the wires to achieve superconducting performance. In this study, a field loss analysis and low-temperature heat transfer analysis of the cooling system were performed through the conceptual design of a 100-HP high-temperature superconducting synchronous motor. The field loss analysis shows that a uniform pore magnetic flux density appears when high-temperature superconducting wire is used. The low-temperature heat transfer analysis for gaseous neon and liquid neon showed that a flow rate of 1 kg/min of liquid neon is suitable for maintaining low-temperature stability of the high-temperature superconducting wire.

[Fe II] $1.64{\mu}m$ Outflow Features around Ultracompact H II Regions in the First Galactic Quadrant

  • Shinn, Jong-Ho;Kim, Kee-Tae;Lee, Jae-Joon;Lee, Yong-Hyun;Kim, Hyun-Jeong;Pyo, Tae-Soo;Koo, Bon-Chul;Kyeong, Jaemann;Hwang, Narae;Park, Byeong-Gon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.68.2-69
    • /
    • 2015
  • We present [Fe II] $1.644{\mu}m$ features around ultracompact H II regions (UCHIIs) found on a quest for the "footprint" outflow features of UCHIIs -the features produced by outflowing materials ejected during an earlier, active accretion phase of massive young stellar objects (MYSOs). We surveyed 237 UCHIIs in the first Galactic quadrant, employing the CORNISH UCHII catalog and UWIFE data, which is an imaging survey in [Fe II] $1.644{\mu}m$ performed with UKIRT-WFCAM under ~0.''8 seeing conditions. The [Fe II] features were found around five UCHIIs. We interpret the [Fe II] features to be shock-excited by outflows from YSOs and estimate the outflow mass-loss rates from the [Fe II] flux which are ${\sim}1{\times}10^{-6}-4{\times}10^{-5}M{\odot}yr^{-1}$. We propose that the [Fe II] features might be the "footprint" outflow features, but more studies are required to clarify whether or not this is the case. This is based on the morphological relation between the [Fe II] and 5 GHz radio features, the outflow mass-loss rate, the travel time of the [Fe II] features, and the existence of several YSO candidates near the UCHIIs.

  • PDF

COMS DATS Implementation and Test (통신해양기상위성 데이터 송수신 서브시스템의 구축 및 시험)

  • Park, Durk-Jong;Kim, Su-Jin;Ahn, Sang-Il
    • Journal of Astronomy and Space Sciences
    • /
    • v.25 no.4
    • /
    • pp.459-470
    • /
    • 2008
  • DATS which is one of three subsystems of IDACS is responsible to receive Sensor Data, LRIT and HRIT in L-Band and transmit LRIT and HRIT in S-Band from/to COMS satellite. This paper shows detailed test procedures used to verify the performance and functionality of DATS after its implementation was completely finished. As a part of efforts to verify key DATS performance, G/T and EIRP were measured by using solar flux density as radio source. Regarding the verification of DATS functionality, RF loop-back test was conducted to validate if there is no BER degradation excepting MODEM/BB implementation loss occurred in the integrated DATS. Integrated with 13m antenna, DATS successfully restored image from received MTSAT-1R broadcasting data, LRIT and HRIT, of which frequencies are all L-Band. S-Band transmission was also verified through test antenna placed away from 13m antenna by measuring real LRIT and HRIT spectrum in S-Band. From those test results, DATS is determined to be fully ready to communicate with COMS in L-Band and S-Band.

Mixing and Penetration Studies of Transverse Jet into a Supersonic Crossflow (초음속 유동 내 공동을 이용한 수직 분사 혼합 및 연료 침투거리에 관한 연구)

  • Kim, Chae-Hyoung;Jeong, Eun-Ju;Jeung, In-Seuck;Kang, Sang-Hun;Yang, Soo-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.2
    • /
    • pp.24-32
    • /
    • 2008
  • A non-reacting experimental study on a normal injection into a Mach 1.92 crossflow which flows over various geometries(flat plate, small cavity, large cavity) was carried out to investigate the effect of the momentum flux ratio(J). The aft ramp of the cavity advances the increase of the penetration height and the strong two-dimensional shock from recompression region mainly affects the shock structure and mixing layer at the downstream flow. As flow runs downward, the transverse penetration height increases with increasing J(J = 0.9, 1.7, 3.4). However, above some critical ratio, jet penetration height growth with increasing J is not appeared in flow-field. Large scale cavity has a good mixing efficiency but it increases the drag loss in the combustor.

Sensitivity Analyses for Maximum Heat Removal from Debris in the Lower Head

  • Kim, Yong-Hoon;Kune Y. Suh
    • Nuclear Engineering and Technology
    • /
    • v.32 no.4
    • /
    • pp.395-409
    • /
    • 2000
  • Parametric studies were performed to assess the sensitivity in determining the maximum in-vessel heat removal capability from the core material relocated into the lower plenum of the reactor pressure vessel (RPV)during a core melt accident. A fraction of the sensible heat can be removed during the molten jet delivery from the core to the lower plenum, while the remaining sensible heat and the decay heat can be transported by rather complex mechanisms of the counter-current flow limitation (CCFL) and the critical heat flux (CHF)through the irregular, hemispherical gap that may be formed between the freezing oxidic debris and the overheated metallic RPV wall. It is shown that under the pressurized condition of 10MPa with the sensible heat loss being 50% for the reactors considered in this study, i.e. TMI-2, KORI-2 like, YGN-3&4 like and KNGR like reactors, the heat removal through the gap cooling mechanism was capable of ensuring the RPV integrity as much as 30% to 40% of the total core mass was relocated to the lower plenum. The sensitivity analysis indicated that the cooling rate of debris coupled with the sensible heat loss was a significant factor The newly proposed heat removal capability map (HRCM) clearly displays the critical factors in estimating the maximum heat removal from the debris in the lower plenum. This map can be used as a first-principle engineering tool to assess the RPV thermal integrity during a core melt accident. The predictive model also provided ith a reasonable explanation for the non-failure of the test vessel in the LAVA experiments performed at the Korea Atomic Energy Research Institute (KAERI), which apparently indicated a cooling effect of water ingression through the debris-to-vessel gap and the intra-debris pores and crevices.

  • PDF

Heat Treatment Effect on Pitting Corrosion of Super Duplex Stainless Steel UNS S32750 FCA Welds (슈퍼 듀플렉스 스테인리스강 UNS S32750의 FCA 용접 후 열처리가 공식에 미치는 영향)

  • Jang, Bok-Su;Moon, In-June;Kim, Se-Cheol;Koh, Jin-Hyun
    • Journal of Welding and Joining
    • /
    • v.31 no.5
    • /
    • pp.20-25
    • /
    • 2013
  • This study was carried out to investigate the influence of a sigma phase precipitation on the pitting corrosion resistance and microstructural change of super duplex stainless steels(UNS S32750). The welds made by FCAW (Flux Cored Arc Welding) were heat treated ($930^{\circ}C$, $1080^{\circ}C$, $1230^{\circ}C$) and quenched. Based on the microstructural examination, it was found that the ${\sigma}$ phase was formed in base metals and welds heat treated at $930^{\circ}C$ while there were little ${\sigma}$phases formed in base metals and weld metal experienced the relatively fast cooling from $1080^{\circ}C$ and $1230^{\circ}C$. On the other hand, the most weight loss due to pitting corrosion occurred in base and weld metals heat treated at $930^{\circ}C$. It was confirmed that the pitting corrosion occurred in the phase boundaries of ferrite/sigma and austenite/sigma. The pitting corrosion resistance decreased owing to an increase in Cr, Mo depleted areas adjacent to the intermetallic phases such as ${\sigma}$phases. The hardness was greatly increased due to the precipitation ${\sigma}$phases.

1.64 ${\mu}m$ features of Jets and Outflows from Young Stellar Objects in the Carina Nebula

  • Shinn, Jong-Ho;Pyo, Tae-Soo;Lee, Jae-Joon;Lee, Ho-Gyu;Kim, Hyun-Jeong;Koo, Bon-Chul;Sung, Hwankyung;Chun, Moo-Young;Lyo, A. Ran;Moon, Dae-Sik;Kyeong, Jaemann;Park, Byeong-Gon;Hur, Hyeonoh;Lee, Yong-Hyun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.56.2-56.2
    • /
    • 2014
  • We present [Fe II] 1.64 ${\mu}m$ imaging observations for jets and outflows from young stellar objects over the northern part (${\sim}24^{\prime}{\times}45^{\prime}$) of the Carina Nebula, a massive star forming region. The observations were performed with IRIS2 of Anglo-Australian Telescope and the seeing was ~1.5". Eleven jets and outflows features are detected at eight different regions, and are termed as Ionized Fe Objects (IFOs). The [Fe II] features have knotty or elongated shapes, and the detection rate of IFOs against previously identified YSOs is 1.4%. Four IFOs show anti-correlated peak intensities in [Fe II] and $H{\alpha}$, where the ratio I([Fe II])/I($H{\alpha}$) is higher for longish IFOs than for knotty IFOs. We estimate the outflow mass loss rate from the [Fe II] flux using two different methods. The jet-driving objects are identified for three IFOs (IFO-2, -4, and -7). The ratios of the outflow mass loss rate over the disk accretion rate for IFO-4 and -7 are consistent with the previously reported values ($10^{-2}-10^{+1}$), while the ratio is higher for IFO-2. This excess may result from underestimating the disk accretion rate. Other YSO physical parameters show reasonable relations or trends.

  • PDF

The Effects of Co Addition on Glass Forming Ability and Magnetic Properties for FeSiBNb Ribbon Alloys (FeSiBNb 리본 합금의 비정질 형성능과 자기적 특성에 미치는 Co의 첨가 효과)

  • Lee, Tae-Gyu;Noh, Tae-Hwan
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.3
    • /
    • pp.128-132
    • /
    • 2007
  • The thermal and magnetic properties of amorphous (FeCo)SiBNb ribbon alloys with high glass forming ability have been investigated. The glass forming ability was enhanced by Co substitution in amorphous ($Fe_{1-X}Co_X)_{72}Si_4B_{20}Nb_4$ alloys with the thickness of about $40{\mu}m$. With the increase in Co content, the temperature range of supercooled liquid phase increased indicating the high glass forming ability of the Co-added alloys. Further the ac permeability increased, and the core loss decreased considerably by Co substitution, while small change in $B_8$ (magnetic flux density at 800 A/m) was observed. The frequency characteristics of permeability deteriorated as compared to conventional amorphous ribbon alloys with the thickness of about $20\;{\mu}m$ due to the increased skin effect.

Changes in Fire Characteristics according to the Distance Between the Fire Source and Sidewall in a Reduced-Scale Compartment (축소 구획실에서 화원과 측벽의 거리에 따른 화재특성 변화)

  • Yun, Hong-Seok;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.50-59
    • /
    • 2019
  • Experimental and numerical studies on the fire characteristics according to the distance between the fire source and sidewall under the over-ventilated fire conditions. A 1/3 reduced ISO 9705 room was constructed and spruce wood cribs were used as fuel. Fire Dynamics Simulator (FDS) was used for fire simulations to understand the phenomenon inside the compartment. As a result, the mass loss rate and heat release rate were increased due to the thermal feedback effect of the wall in the compartment fire compared to the open fire. As the distance between the fire source and sidewall was reduced, the major fire characteristics, such as maximum mass loss rate, heat release rate, fire growth rate, temperature, and heat flux, were increased despite the limitations of air entrainment into the flame. In particular, a significant change in these physical quantities was observed for the case of a fire source against the sidewall. In addition, the vertical distribution of temperature was changed considerably due to a change in the flow structure inside the compartment according to the distance between the fire source and sidewall.