• 제목/요약/키워드: flux flow

검색결과 1,680건 처리시간 0.03초

Transient Critical Heat Flux Under Flow Coastdown in a Vertical Annulus With Non-Uniform Heat Flux Distribution

  • Moon, Sang-Ki;Chun, Se-Young;Park, Ki-Yong;Baek, Won-Pil
    • Nuclear Engineering and Technology
    • /
    • 제34권4호
    • /
    • pp.382-395
    • /
    • 2002
  • An experimental study on transient critical heat flux (CHF) under flow coastdown has been performed for the water flow in a non-uniformly heated vertical annulus under low flow and a wide range of pressure conditions. The objectives of this study are to systematically investigate the effect of the flow transient on the CHF and to compare the transient CHF with steady-state CHF The transient CHF experiments have been performed for three kinds of flow transient modes based on the coastdown data of a nuclear power plant reactor coolant pump. At the same inlet subcooling, system pressure and heat flux, the effect of the initial mass flux on the critical mass flux can be negligible. However, the effect of the initial mass flux on the time-to- CHF becomes large as the heat flux decreases. The critical mass flux has the largest value for slow flow reduction rate. There is a pressure effect on the ratio of the transient CHF data to steady-state CHF data. Except under low system pressure conditions, the flow transient CHF was revealed to be conservative compared with the steady-state CHF data. Bowling CHF correlation and thermal hydraulic system code MARS show promising results for the prediction of CHF occurrence .

수직 액막형 흡수기의 흡수성능 변화에 미치는 냉각수 유량의 영향 (Effect of the Flow Rate of Coolant on the Absorption Peformance of a Vertical Absorber)

  • 김정국;조금남
    • 설비공학논문집
    • /
    • 제18권5호
    • /
    • pp.410-417
    • /
    • 2006
  • The present study predicted the effect of the flow rate of coolant on the absorption performance of a vertical falling film type absorber Heat and mass transfer peformances were numerically investigated. The exit temperatures of solution and coolant were decreased as the flow rate of the coolant was increased at the film Reynolds number of 100. The absorption mass flux was increased and then decreased as the distance from the inlet of the absorber was increased. The distance showing the maximum absorption mass flux was ranged from 0.3 to 0.5m. The heat flux and the absorption mass flux were increased and then slowly decreased as the flow rate of the coolant was increased. The maximum values were obtained at the flow rate of coolant of 2.0L/min.

인덕턴스 복사계 측정을 위해 사용된 초전도 자속 흐름 센서기 모델링 (Modeling of a Superconducting Flux Flow Sensor Inductance Radiometer)

  • 고석철;강형곤;임성훈;최명호;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 센서 박막재료 반도체 세라믹
    • /
    • pp.19-22
    • /
    • 2003
  • For use in constructing highly sensitive thermal detectors, the present authors have been studying the preparation of Superconducting Flux Flow Sensor(SFFS). In this research, SFFS with five channel ($5{\mu}m$/1channel) has been fabricated based on the flux flow using high temperature superconducting thin films by the ICP etching technique. We have designed a bolometer based on the temperature dependence of the kinetic inductance of a superconducting flux flow thin film. In this paper examines the fabrications and flux flow resistance and thermometer responses of the highly sensitive sensor constructed of a thin YBCO film. It is also suggested that they will be applicable to a new type of flux flow sensor.

  • PDF

Modeling of flux enhancement in presence of concentration polarization by pressure pulsation during laminar cross flow ultrafiltration

  • Kumar, Kamal;De, Sirshendu
    • Membrane and Water Treatment
    • /
    • 제1권4호
    • /
    • pp.253-271
    • /
    • 2010
  • A theoretical study for the flux enhancement by pulsation of transmembrane pressure is presented for osmotic pressure controlled ultrafiltration under laminar flow regime. The transient velocity profile is solved analytically using Green's function method. Time dependent convective diffusive equation is solved to quantify the membrane surface concentration and the permeate flux, numerically. The effects of the amplitude and frequency of pulsation on flux, surface concentration and observed retention are studied.

Cross-Flow Filtration에 의한 항생물질 생산 균사체의 분리 (Separation of Antibiotics-Producing Mycelia by Cross-Flow Filteration)

  • 정상철;윤종원
    • KSBB Journal
    • /
    • 제4권2호
    • /
    • pp.177-184
    • /
    • 1989
  • 항생물질 발효액의 균사체 분리에 있어서 Modified regenerated cellulose 막을 이용한 Cross-flow filtration으로 높은 Flux를 얻을 수 있었다. 막분리시 가급적 높은 유속, 높은 온도, 특정 균사체농도(약 20% PMV)에서 높은 Flux를 보여주었으며 Fouling 정도는 균사체 농도가 높을수록 또한 유속이 낮을수록 심각한 것으로 나타났다. 발효액을 농축 분리할 때의 Flux profile은 1단계 Sublayer형성에 의한 급속감소, 2단계 평형, 3단계 Fouling에 의한 급속감소의 세 구간으로 나눌 수 있었으며 Diafiltration의 적용으로 3단계의 Flux 감소 현상을 현저히 완화시킬 수 있었다. 한편 Diafiltration에 의한 항생물질 회수시 초기부터Diafiltration하는 것보다는 특정 PMV까지 농축시킨 후 Diafiltration하는 경우에 작업시간과 여액의 Volume을 최소화 할 수 있었으며 본 실험에서는 98%의 회수율을 얻기 위해서 Di-afiltration을 시작하는 Optimum PMV는 20%였다.

  • PDF

$N_2$ flow rate가 GaN 박막의 특성에 미치는 영향 (Effect of $N_2$ flow rate on properties of GaN thin films)

  • 허광수;박민철;명재민
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.66-69
    • /
    • 2001
  • Effect of $N_2$ flow rate on properties of GaN thin films grown by plasma-enhanced molecular beam epitaxy(PEMBE) was discussed to optimize the quality of thin films. It was found that at low $N_2$ flow rate indicating high III/V flux ratio, the growth rate of GaN thin films was controlled by $N_2$ flux, and at high $N_2$ flow rate the growth rate was not controlled by $N_2$ flux any longer. It was also found that III/V flux ratio affected film quality. The film grown at higher $N_2$ flow rate showed low background carrier concentration, higher carrier mobility, and narrow FWHM in band-edge emission of low temperature PL. It is thought that the film in more Ga flux region was grown by 2-dimensional layer-by-layer growth mode, and the film in more nitrogen region was grown by 3-D island growth mode. All samples exhibited a good crystallinity.

  • PDF

맥동관 내부의 열전달에 관한 실험적 연구 (Experimental study on the transfer in pulse tube)

  • 김민규;남관우;정상권;장호일;정은수
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권1호
    • /
    • pp.45-50
    • /
    • 2000
  • The present study has been conducted to observe the heat transfer under pulsating pressure and oscillating flow. The experimental apparatus was fabricated to measure the gas temperature, the wall temperature. the pressure and the instantaneous heat flux inside the pulse tube. The measured gas temperature and heat flux must be calibarated to compensate their finite time constant in the oscillating flow conditious. The experiment was performed from 1 Hz to 5 Hz. The phase difference between the instantaneous heat flux and the gas-wall temperature difference was clearly observed. The experimental heat fluxes were compared to the theroretical correlations such as Complex Nusselt Number Model(CNNM) and Variable Coefficient Model(CVM). The heat flux predisted by CNNM was always greater than that of VCM. The experiment confirmed the valisity of the VCM for the instantaneous heat flux under the pulsating pressure and oscillating flow in the warm end of the pulse tube.

  • PDF

저온의 순수물속에 잠겨있는 약간 경사진 균일 열유속 원기등에 의한 자연대류의 실험적 연구 (Experimental Study of Natural Convection from a Slightly Inclined Cylinder with Uniform Heat Flux Immersed in Cold Pure Water)

  • 유갑종;추홍록;장우석
    • 대한기계학회논문집
    • /
    • 제18권7호
    • /
    • pp.1799-1807
    • /
    • 1994
  • Natural convection from a slightly inclined circular cylinders immersed in quiescent cold pure water was studied experimentally. The experiment was carried out for circular cylinders with uniform heat flux ranging from $100W/m^{2} to 800 W/m^{2}$ and inclined angle ranging from horizontal $({\phi}=0^{\circ}) to 15^{\circ}$. The flow fields around cylinder were visualized and heat transfer characteristics investigated by measuring the surface temperatures for each case. As the results, it is shown that flow patterns are changed consecutively through the sequence of steady state downflow, unsteady state flow and steady state upflow with increasing heat flux. At the same inclined angle, as heat flux increases, the average Nusselt number decreases and then increases. At the same heat flux, as inclined angle increases, the average Nusselt number decreases.

Operational Characteristics of Superconducting Amplifier using Vortex Flux Flow

  • Lim, Sung-Hun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권6호
    • /
    • pp.260-264
    • /
    • 2008
  • The operational characteristics of superconducting amplifier using vortex flux flow were analyzed from an equivalent circuit in which its current-voltage characteristics for the vortex motion in YBCO microbridge were reflected. For the analysis of operation as an amplifier, dc bias operational point for the superconducting amplifier is determined and then ac operational characteristics for the designed superconducting amplifier were investigated. The variation of transresistance, which describes the operational characteristics of superconducting amplifier, was estimated with respect to conditions of dc bias. The current and the voltage gains, which can be derived from the circuit for small signal analysis, were calculated at each operational point and compared with the results obtained from the numerical analysis for the small signal circuit. From our paper, the characteristics of amplification for superconducting flux flow transistor (SFFT) could be confirmed. The development of the superconducting amplifier applicable to various devices is expected.

액막류의 MHF 점에 관한 실험적 연구 (Experimental Study on Minimum Heat Flux Point of Liquid Film Flow)

  • 김영찬
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.208-213
    • /
    • 2001
  • The minimum heat flux conditions are experimentally investigated for the subcooled liquid film flow on the horizontal plate. The experimental results show that the minimum heat flux point temperature becomes higher with the increase of the velocity and the subcooling of the liquid film flow. However, the effect of distance from the leading edge of the heat transfer plate on the minimum heat flux is almost negligible. Also, the experimental results show that the propagation velocity of wetting front increase with increasing the velocity and the subcooling of the liquid film flow.

  • PDF