• Title/Summary/Keyword: flux data quality

Search Result 176, Processing Time 0.027 seconds

KoFlux's Progress: Background, Status and Direction (KoFlux 역정: 배경, 현황 및 향방)

  • Kwon, Hyo-Jung;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.12 no.4
    • /
    • pp.241-263
    • /
    • 2010
  • KoFlux is a Korean network of micrometeorological tower sites that use eddy covariance methods to monitor the cycles of energy, water, and carbon dioxide between the atmosphere and the key terrestrial ecosystems in Korea. KoFlux embraces the mission of AsiaFlux, i.e. to bring Asia's key ecosystems under observation to ensure quality and sustainability of life on earth. The main purposes of KoFlux are to provide (1) an infrastructure to monitor, compile, archive and distribute data for the science community and (2) a forum and short courses for the application and distribution of knowledge and data between scientists including practitioners. The KoFlux community pursues the vision of AsiaFlux, i.e., "thinking community, learning frontiers" by creating information and knowledge of ecosystem science on carbon, water and energy exchanges in key terrestrial ecosystems in Asia, by promoting multidisciplinary cooperations and integration of scientific researches and practices, and by providing the local communities with sustainable ecosystem services. Currently, KoFlux has seven sites in key terrestrial ecosystems (i.e., five sites in Korea and two sites in the Arctic and Antarctic). KoFlux has systemized a standardized data processing based on scrutiny of the data observed from these ecosystems and synthesized the processed data for constructing database for further uses with open access. Through publications, workshops, and training courses on a regular basis, KoFlux has provided an agora for building networks, exchanging information among flux measurement and modelling experts, and educating scientists in flux measurement and data analysis. Despite such persistent initiatives, the collaborative networking is still limited within the KoFlux community. In order to break the walls between different disciplines and boost up partnership and ownership of the network, KoFlux will be housed in the National Center for Agro-Meteorology (NCAM) at Seoul National University in 2011 and provide several core services of NCAM. Such concerted efforts will facilitate the augmentation of the current monitoring network, the education of the next-generation scientists, and the provision of sustainable ecosystem services to our society.

Boiling Heat Transfer Characteristics of $CO_2$ in Horizontal Smooth Microchannel (수평 microchannel의 $CO_2$ 비등열전달)

  • Choi, Kwang-Il;Ardiyansyah, Ardiyansyah;Oh, Jong-Taek
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.241-246
    • /
    • 2007
  • The present paper dealt with an experimental study of boiling heat transfer characteristics of $CO_2$. Heat transfer coefficients of the refrigerant flow inside horizontal smooth microchannel were obtained with inner tube diameter of 0.3mm and length of 300mm. The direct electric heating method was applied for supplying the heat uniformly to the refrigerant. The experiments were conducted with $CO_2$ purity of 99.99%, at saturation temperature of $10^{\circ}C$, mass flux ranges of $300{\sim}900\;kg/m^2s$, and heat flux ranges of $15{\sim}45\;kW/m^2$. While heat transfer coefficient increased with the increase of heat flux in the low quality region, the heat transfer coefficient decreased with the increase of quality in the high quality region. The heat transfer coefficients were compared with seven existing correlations with the Gungor-Winterton's(1986) correlation gave the best prediction. A new corelation to predict the two-phase flow heat transfer coefficient was developed based on the Chen(1966) correlation. The new correlation predicted the experimental data well with a mean deviation of 9.69% and average deviation of -3.03%.

  • PDF

Convective Boiling of R-410A in an Aluminum Flat Tube for Air-Conditioning Application (공조용 알루미늄 납작관 내의 R-410A 대류 비등)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3006-3013
    • /
    • 2015
  • Flat tube heat exchangers can improve the thermal performance significantly compared with round tube heat exchangers. For proper design of flat tube heat exchangers, one should know the tubeside heat transfer coefficients. In this study, convective boiling heat transfer coefficients of R-410A were obtained in a flat extruded aluminum tube with $D_h=1.41mm$. The test range covered mass flux from 200 to $600kg/m^2s$, heat flux from 5 to $15kW/m^2$ and saturation temperature from $5^{\circ}C$ to $15^{\circ}C$. The heat transfer coefficient curve shows a decreasing trend after a certain quality(critical quality). The critical quality decreases as the heat flux increases, and as the mass flux decreases. The early dryout at a high heat flux results in a unique 'cross-over' of the heat transfer coefficient curves. The heat transfer coefficient increases as the mass flux increases. At a low quality region, however, the effect of mass flux is not prominent. The heat transfer coefficient increases as the saturation temperature increases. The effect of saturation temperature, however, diminishes as the heat flux decreases. Both the Shah and the Kaew-On et al. correlations reasonably predicted the present data.

Pollutant Flux Releases During Summer Monsoon Period based on Hydrological Modeling in Two Forested Watersheds, Soyang Lake

  • Kang, S.H.
    • Environmental Engineering Research
    • /
    • v.14 no.1
    • /
    • pp.13-18
    • /
    • 2009
  • In this study, specific pollutant releases during the Asian monsoon season were estimated and the information was applied to the non-point pollutant sources management from two forested watersheds of the Soyang Lake. The two watersheds are part of the 2,703 km2 Soyang Lake watershed in the northern region of the Han River. The outlets of the two watersheds were respectively analyzed for continuous water quality concentration and for discharge during various single rainfall events. Statistical power function methods are utilized to compare stream discharge and pollutant flux release during the study period. Based on the monitoring data during the study period, the specific load flux method using simulated discharge was conducted and validated in the two watersheds. The model predictions corresponded well with the measured and calculated pollutant releases. The modeling approach taken in this study was found to be applicable for the two forested watersheds.

Changes and Improvements of the Standardized Eddy Covariance Data Processing in KoFlux (표준화된 KoFlux 에디 공분산 자료 처리 방법의 변화와 개선)

  • Kang, Minseok;Kim, Joon;Lee, Seung-Hoon;Kim, Jongho;Chun, Jung-Hwa;Cho, Sungsik
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.20 no.1
    • /
    • pp.5-17
    • /
    • 2018
  • The standardized eddy covariance flux data processing in KoFlux has been updated, and its database has been amended accordingly. KoFlux data users have not been informed properly regarding these changes and the likely impacts on their analyses. In this paper, we have documented how the current structure of data processing in KoFlux has been established through the changes and improvements to ensure transparency, reliability and usability of the KoFlux database. Due to increasing diversity and complexity of flux site instrumentation and organization, we have re-implemented the previously ignored or simplified procedures in data processing (e.g., frequency response correction, stationarity test), and added new methods for $CH_4$ flux gap-filling and $CO_2$ flux correction and partitioning. To evaluate the effects of the changes, we processed the data measured at a flat and homogeneous paddy field (i.e., HPK) and a deciduous forest in complex and heterogeneous topography (i.e., GDK), and quantified the differences. Based on the results from our overall assessment, it is confirmed that (1) the frequency response correction (HPK: 11~18% of biases for annually integrated values, GDK: 6~10%) and the stationarity test (HPK: 4~19% of biases for annually integrated values, GDK: 9~23%) are important for quality control and (2) the minimization of the missing data and the choice of the appropriate driver (rather than the choice of the gap-filling method) are important to reduce the uncertainty in gap-filled fluxes. These results suggest the future directions for the data processing technology development to ensure the continuity of the long-term KoFlux database.

Phenomenological Liquid Film Dryout Model for Upward Flow in Tubes and Annuli (원형 및 환상 채널에 흐르는 수직 상향류의 액막 건조 모델)

  • Hong, Sung-Deok;Chun, Se-Young
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.201-207
    • /
    • 2001
  • We modeled the liquid film dryout(LFD) process for both tube and annulus which have uniformly heated vertical channels. We set phenomenological initial conditions in the model. The initial void fraction on the onset of the annular flow location is derived from the physical chum-to-annular flow criterion with the help of the drift-flux-model. The initial thermodynamic-equilibrium-quality is calculated by iteration with the flow quality to find the onset of the annular-flow location. Present model tends to predict very well at the lower exit quality but under-estimates at the higher exit quality. We found that the prediction error of the present model is gradually bigger as the inlet subcooling approaches near the saturation. We obtained excellent results for both tube and annulus channels as the mean of 0.97 and root-mean-square error of 11% for the number of 3883 experimental data on tubes, and of 0.96 and of 12% for 593 on annuli. The present model extended the applicable range to the relatively low exit quality region than previous LFD models.

  • PDF

A Prediction Model for Condensation of Zeotropic Refrigerant Mixtures Inside a Horizontal Smooth Tube (수평평활관내의 비공비 혼합냉매의 응축에 대한 예측모델)

  • ;;小山繁
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.4
    • /
    • pp.262-270
    • /
    • 2001
  • This paper deals with a prediction method for the condensation of ternary refrigerant mixture inside a horizontal smooth tube. Based on some reliable assumptions, the governing equations for the local heat and mass transfer characteristics are derived, and the prediction for the condensation of ternary zeotropic refrigerant mixtures composed of HFC32/HFC125/HFC134a, including R407C, is carried out. The local values of vapor quality, thermodynamic states at bulk vapor, vapor-liquid interface and bulk liquid, mass flux etc. are obtained for a constant wall temperature and a constant wall heat flux conditions, and the effects of the composition of HFC32/HFC125/HFC134a on heat transfer characteristics are examined. The prediction result is also compared with experimental data for condensation of ternary refrigerant mixtures. The predicted wall temperature distribution has a similar trend with experimental data but the predicted local heat transfer coefficients are 20-30% higher than the experimental data.

  • PDF

An Improved Mechanistic Critical Heat Flux Model for Subcooled Flow Boiling

  • Young Min Kwon;Soon Heung Chang
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.552-557
    • /
    • 1997
  • Based on the bubble coalescence adjacent to the heated wall as a flow structure for CHF condition, Chang and Lee developed a mechanistic critical heat flux (CHF) model for subcooled flow boiling. In this paper, improvements of Chang-Lee model are implemented with more solid theoretical bases for subcooled and low-quality flow boiling in tubes. Nedderman-Shearer's equations for the skin friction factor and universal velocity profile models are employed. Slip effect of movable bubbly layer is implemented to improve the predictability of low mass flow. Also, mechanistic subcooled flow boiling model is used to predict the flow quality and void fraction. The performance of the present model is verified using the KAIST CHF database of water in uniformly heated tubes. It is found that the present model can give a satisfactory agreement with experimental data within less than 9% RMS error.

  • PDF

An Experimental Study on Flow Boiling Heat Transfer within Horizontal Rectangular Channels with Small Heights (미세 수평 사각 유로에서의 비등 열전달에 대한 실험적 연구)

  • Lee, Sang-Yong;Lee, Han-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.9
    • /
    • pp.1209-1218
    • /
    • 2001
  • The present paper proposes a new correlation for the flow boiling heat transfer coefficients in the low flow rate condition (Re(sub)LF$\leq$200) within horizontal rectangular channels with small gaps (heights). The gap between the upper and the lower plates of each channel ranges from 0.4 to 2mm while the channel width being fixed to 20mm. Refrigerant 113 was used as the test fluid. The mass flux ranges from 50 to 200kg/㎡s and the channel walls were uniformly heated with the heat flux range of 3-15kW/㎡. The quality range covers from 0.19 to 0.76 and the flow pattern is considered to be annular. The measured heat transfer coefficients increase with the mass flux and the local quality; however the effect of the heat flux appears to be minor. At the low mass flux condition, which is more likely with the smaller gap size, the heat transfer is primarily controlled by the liquid film thickness. The proposed F factor for the heat transfer coefficient in the range of Re(sub)LF$\leq$200 well represents the experimental data within the deviation of $\pm$20%. The Kandlikars flow boiling correlation covers the higher flow-rate range(Re(sub)LF>200) within the deviation of $\pm$20%.

Condensation Heat Transfer and Pressure Drop of R-134a in the Oblong Shell and Plate Heat Exchanger

  • Park Jae-Hong;Kim Young-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.3
    • /
    • pp.158-167
    • /
    • 2004
  • Condensation heat transfer experiments were conducted with a oblong shell and plate heat exchanger without oil in a refrigerant loop using R-134a. An experimental refrigerant loop has been developed to measure the condensation heat transfer coefficient $h_r$ and frictional pressure drop ${\Delta}p_f$ of R-134a in a vertical oblong shell and plate heat exchanger. Four vertical counter flow channels were formed in the oblong shell and plate heat exchanger by four plates having a corrugated sinusoid shape of a $45^{\circ}$ chevron angle. The effects of the refrigerant mass flux, average heat flux, refrigerant saturation temperature and vapor quality were explored in detail. Similar to the case of a plate heat exchanger, even at a very low Reynolds number, the flow in the oblong shell and plate heat exchanger remains turbulent. The results indicate that the condensation heat transfer coefficients and pressure drops increase with the vapor quality. A rise in the refrigerant mass flux causes an increase in the $h_r\;and\;{\Delta}p_f$. Also, a rise in the average heat flux causes an increase in the $h_r$. But the effect of the average heat flux does not show significant effect on the ${\Delta}p_f$. On the other hand, at a higher saturation temperature, both the $h_r\;and\;{\Delta}p_f$. found to be lower. Based on the present data, the empirical correlations are provided in terms of the Nusselt number and friction factor.