• Title/Summary/Keyword: flux data quality

Search Result 176, Processing Time 0.027 seconds

A Method for Critical Heat Flux Prediction in Vertical Round Tubes with Axially Non-uniform Heat Flux Profile

  • Shim, Jae-Woo
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.13-21
    • /
    • 2008
  • In this study a method to predict CHF(Critical heat flux) in vertical round tubes with axially non-uniform cosine heat flux distribution for water was examined. For this purpose a local condition hypothesis based CHF prediction correlation for uniform heat flux in vertical round tubes for water was developed from 9,366 CHF data points. The local correlation consisted of 4 local condition variables: the system pressure(P), tube diameter(D), mass flux of water(G), and 'true mass quality' of vapor($X_t$). The CHF data points used were collected from 13 different published sources having the following operation ranges: 1.01 ${\leq}$ P (pressure) ${\leq}$ 206.79 bar, 9.92${\leq}$ G (mass flux) ${\leq}$ 18,619.39 $kg/m^2s$, 0.00102 ${\leq}$ D(diameter) ${\leq}$ 0.04468 m, 0.0254${\leq}$ L (length) ${\leq}$ 4.966 m, 0.11 ${\leq}$ qc (CHF) ${\leq}$ 21.41 $MVW/m^2$, and -0.87 ${\leq}X_c$ (exit qualities) ${\leq}$ 1.58. The result of this work showed that a uniform CHF correlation can be easily extended to predict CHF in axially non-uniform heat flux heater. In addition, the location of the CHF in axially non-uniform tube can also be determined. The local uniform correlation predicted CHF in tubes with axially cosine heat flux profile within the root mean square error of 12.42% and average error of 1.06% for 297 CHF data points collected from 5 different published sources.

Processing and Quality Control of Flux Data at Gwangneung Forest (광릉 산림의 플럭스 자료 처리와 품질 관리)

  • Lim, Hee-Jeong;Lee, Young-Hee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.10 no.3
    • /
    • pp.82-93
    • /
    • 2008
  • In order to ensure a standardized data analysis of the eddy covariance measurements, Hong and Kim's quality control program has been updated and used to process eddy covariance data measured at two levels on the main flux tower at Gwangneung site from January to May in 2005. The updated program was allowed to remove outliers automatically for $CO_2$ and latent heat fluxes. The flag system consists of four quality groups(G, D, B and M). During the study period, the missing data were about 25% of the total records. About 60% of the good quality data were obtained after the quality control. The number of record in G group was larger at 40m than at 20m. It is due that the level of 20m was within the roughness sublayer where the presence of the canopy influences directly on the character of the turbulence. About 60% of the bad data were due to low wind speed. Energy balance closure at this site was about 40% during the study period. Large imbalance is attributed partly to the combined effects of the neglected heat storage terms, inaccuracy of ground heat flux and advection due to local wind system near the surface. The analysis of wind direction indicates that the frequent occurrence of positive momentum flux was closely associated with mountain valley wind system at this site. The negative $CO_2$ flux at night was examined in terms of averaging time. The results show that when averaging time is larger than 10min, the magnitude of calculated $CO_2$ fluxes increases rapidly, suggesting that the 30min $CO_2$ flux is influenced severely by the mesoscale motion or nonstationarity. A proper choice of averaging time needs to be considered to get accurate turbulent fluxes during nighttime.

Quantitative Study of CO2 based on Satellite Image for Carbon Budget on Flux Tower Watersheds (플럭스 타워 설치 유역을 대상으로 탄소수지 분석을 위한 위성영상자료기반의 CO2 정량화 연구)

  • Jung, Chung Gil;Lee, Yong Gwan;Kim, Seong Joon;Jang, Cheol Hee
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.3
    • /
    • pp.109-120
    • /
    • 2015
  • Spatial heterogeneous characteristics of solar radiation energy from Climate Change gives rise to energy imbalance in the general ecological system including water resources. This study is to estimate the $CO_2$ flux of South Korea using Terra MODIS image and to assess the reliability of MODIS data from the ground measured $CO_2$ flux by eddy covariance flux tower data at 3 locations (two at mixed forest area and one at rice paddy area). The MODIS Gross Primary Productivity (GPP) product (MOD17A2), 8-day composite at 1-km spatial resolution was adopted for the spatial $CO_2$ flux generation. The MOD17A2 data by noise like cloud and snow in a day were tried to fill by Inverse Distance Weighted (IDW) method from valid pixels and the damping effect of MOD17A2 data were corrected by Quality Control (QC) flag. The MODIS $CO_2$ flux was estimated as the sum of GPP and Re (ecosystem respiration) by Lloyd and Taylor method (1994). The determination coefficient ($R^2$) between MODIS $CO_2$ and flux tower $CO_2$ for 3 years (2011~2013) showed 0.55 and 0.60 in 2 mixed forests and 0.56 in rice paddy respectively. The $CO_2$ flux generally fluctuated showing minus values during summer rainy season (from July to August) and maintaining plus values for other periods. The MODIS $CO_2$ flux can be a useful information for extensive area, for example, as a reliable indicator on ecological circulation system.

Operational Water Temperature Forecast for the Nakdong River Basin Using HSPF Watershed Model (HSPF 유역모델을 이용한 낙동강유역 실시간 수온 예측)

  • Shin, Chang Min;Na, Eun Hye;Kim, Duck Gil;Kim, Kyunghyun
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.6
    • /
    • pp.673-682
    • /
    • 2014
  • A watershed model was constructed using Hydrological Simulation Program Fortran to predict the water temperature at major tributaries of Nakdong River basin, Korea. Water temperature is one of the most fundamental indices used to determine the nature of an aquatic environment. Most processes of an aquatic environment such as saturation level of dissolved oxygen, the decay rate of organic matter, the growth rate of phytoplankton and zooplankton are affected by temperature. The heat flux to major reservoirs and tributaries was analyzed to simulate water temperature accurately using HSPF model. The annual mean heat flux of solar radiation was estimated to $150{\sim}165W/m^2$, longwave radiation to $-48{\sim}-113W/m^2$, evaporative heat loss to $-39{\sim}-115W/m^2$, sensible heat flux to $-13{\sim}-22W/m^2$, precipitation heat flux to $2{\sim}4W/m^2$, bed heat flux to $-24{\sim}22W/m^2$ respectively. The model was calibrated at major reservoir and tributaries for a three-year period (2008 to 2010). The deviation values (Dv) of water temperature ranged from -6.0 to 3.7%, Nash-Sutcliffe efficiency(NSE) of 0.88 to 0.95, root mean square error(RMSE) of $1.7{\sim}2.8^{\circ}C$. The operational water temperature forecasting results presented in this study were in good agreement with measured data and had a similar accuracy with model calibration results.

Study on Evaporation Heat Transfer of R-l34a, R-407C, and R-410A in the Oblong Shell and Plate Heat Exchanger (오블롱 셀 플레이트 열교환기에서의 R-l34a, R-407C, R-410A의 증발 열전달에 관한 실험적 연구)

  • 박재홍;김영수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.9
    • /
    • pp.845-854
    • /
    • 2004
  • The evaporation heat transfer coefficient for R-l34a, R-407C (a mixture of 23wt% R-32, 25 wt% R-125, and 52 wt% R-l34a) and R-410A (a mixture of 50 wt% R-32 and 50 wt% R-125) flowing in the oblong shell and plate heat exchanger were investigated experimentally in this study. Four vertical counterflow channels were formed in the exchanger by four plates of commercial geometry with a corrugated sinusoid shape of a chevron angle of 45 degree. The effects of the mean vapor quality, mass flux, heat flux, and saturation temperature of different refrigerants on the evaporation heat transfer were explored in detail. Similar to the case of a Plate heat exchanger, even at a very low Reynolds number, the flow in the oblong shell and plate heat exchanger remains turbulent. It is found that the evaporation heat transfer coefficient in the plates is much higher than that in circular pipes. The present data show that the evaporation heat transfer coefficients of all refrigerants increase with the vapor quality. At a higher mass flux h, is higher than for the entire range of the vapor quality. Raising the imposed wall heat flux was found to slightly improve h$_{r}$, while h$_{r}$ is found to be lower at a higher refrigerant saturation temperature. A comparison of the performance of the various refrigerants reveals that R-410A has the highest heat transfer performance followed by R-l34a, and R-407C had the lowest performance of the refrigerants tested. Based on the present data, empirical correlations of the evaporation heat transfer coefficient were proposed.sed.

Experimental Study on R-l34a Condensation Beat Transfer Characteristics in Plate and Shell Heat Exchanger (판각형 열교환기내의 R-134a 응축열전달 특성에 관한 실험적 연구)

  • 이기백;박재홍;서무교;이희웅;김영수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.1
    • /
    • pp.108-116
    • /
    • 2003
  • In this paper, the experimental results of condensation heat transfer were reported for the plate and shell heat exchangers(P&SHE) using R-l34a. An experimental refrigerant loop has been established to measure the condensation heat transfer coefficient of R-l34a in a vertical P&SHE. Two vertical counter flow channels were formed in the P&SHE by three plates of geometry with a corrugated trapezoid shape of a chevron angle of 45$^{\circ}$. Downflow of the condensing R-l34a in one channel releases heat to the cold up flow of water in the other channel. The effect of the refrigerant mass flux, average heat flux, system pressure and vapor quality of R-l34a on the measured data were explored in detail. The results indicate that at a higher vapor quality the condensation heat transfer coefficients are significantly higher. Condensation heat transfer coefficients were increased when the refrigerant mass flux was increased. A rise in the average heat flux causes an slight increase in the hr. Finally, at a higher system pressure the hr is found to be lower. Correlation is also provided for the measured heat transfer coefficients in terms of the Nusselt number.

Experimental Study on R-22 Condensation Heat Transfer Characteristic in Plate and Shell Heat Exchanger (Plate and Shell 열교환기 내의 R-22 응축열전달 특성에 관한 실험적 연구)

  • Seo, Mu-Gyo;Park, Jae-Hong;Kim, Yeong-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.6
    • /
    • pp.860-867
    • /
    • 2001
  • In this study, condensation heat transfer experiments were conducted with plate and shell heat exchangers(P&SHE) using R-22. An experimental refrigerant loop has been established to measure the condensation heat transfer coefficient of R-22 in a vertical P&SHE. Two vertical counter flow channels were formed in the P&SHE by three plates of geometry with a corrugated trapezoid shape of a chevron angle of 45°. Downflow of the condensing R-22 in one channel releases heat to the cold upflow of water in the other channel. The effect of the refrigerant mass flux, average heat flux, system pressure and vapor quality of R-22 on the measured data were explored in detail. The results indicate that at a higher vapor quality the condensation heat transfer coefficients are significantly higher. A rise in the refrigerant mass flux causes an increase in the h(sub)r. Also, a rise in the average heat flux causes an increase in the h(sub)r. Finally, at a higher system pressure the h(sub)r is found to be slightly lower. Correlation is also provided for the measured heat transfer coefficients in terms of the Nusselt number.

A Study on an Electro-Magnetic System far Arc Rotating in MIAB Welding (MIAB용접에서 아크 회전을 위한 전자기 시스템에 관한 연구)

  • 최동혁;김재웅
    • Journal of Welding and Joining
    • /
    • v.19 no.4
    • /
    • pp.391-398
    • /
    • 2001
  • MIAB welding method uses a rotating arc as its heat source and is known to be efficient in pipe butt welding. The arc is rotated around the weld line by the electro-magnetic force resulting from the interaction of arc current and magnetic field. This paper is concerned with the experiment of initial stage for process control, monitoring for weld quality, and the design of coil system which is efficient of flux generation and concentration. A coil system for the generation of magnetic flux was designed and constructed. Magnetic flux density and arc rotating behavior are important factors in MIAB welding, so the relations between these factors and process parameters were investigated. Various experiments were performed for the steel pipes(48.1mm O.D and 2.0mm thickness). The magnetic flux density is increased by increasing exciting current and decreasing gap size. The maximum of arc rotating frequency is affected by exciting current and gap size. However, the variations of arc rotating frequency during welding and then the melting process are mainly influenced by welding current. Thus, it is considered that the results of this study can be used as important data on the monitoring for weld quality and the design of efficient coil system.

  • PDF

Flow Boiling of R-123/Oil Mixture in a Plain Tube Bundle (평활관군 내 R-123/오일의 흐름비등)

  • Lee, Jin-Wook;Lee, Jae-Ho;Kim, Nae-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.10
    • /
    • pp.704-709
    • /
    • 2010
  • The effect of oil on flow boiling of R-123 in a plain tube bundles was experimentally investigated for a range of quality and heat flux. It is shown that the heat transfer coefficient decreased as the oil concentration increased. Comparison with the previous pool boiling data reveals that the reduction of heat transfer coefficient by oil is more pronounced in pool boiling, and the difference increased with the increase of oil concentration and heat flux. Within the experimental range, the variation of mass flux or quality has negligible effect on the heat transfer coefficient.

Surface Flux Measurements at King Sejong Station in West Antarctica: I. Turbulent Characteristics and Sensible Beat Flux (남극 세종기지에서의 지표 플럭스 관측: I. 난류 특성과 현열 플럭스)

  • Choi, Tae-Jin;Lee, Bang-Yong;Lee, Hee-Choon;Shim, Jae-Seol
    • Ocean and Polar Research
    • /
    • v.26 no.3
    • /
    • pp.453-463
    • /
    • 2004
  • The Antarctic Peninsula is important in terms of global warming research due to pronounced increase of air temperature over the last century. The first eddy covariance system was established at King Sejong Station located in the northern region of the Antarctic Peninsula in December of 2002 and has been operated over one year. Here, we analyze turbulent characteristics to determine quality control criteria for turbulent sensible heat flux data as well as to diagnose the possibility of long term eddy covariance measurement under extreme weather conditions of the Antarctic Peninsula. We also report the preliminary result on sensible heat flux. Based on the analyses on turbulent characteristics such as integral turbulence characteristics of vertical velocity (w) and heat (T), stationarity test and investigation of correlation coefficient, they fallow the Monin-Obukhov similarity and eddy covariance flux data were reliable. ${\sim}47%$ of total retrieved sensible heat flux data could be used for further analysis. Daytime averaged sensible heat flux showed a pronounced seasonal variation, with a maximum of up to $300Wm^{-2}$ in summer. In conclusion, continuous and long-term eddy covariance measurement may be possible at the study site and the land surface may influence the atmosphere significantly through heat transport in summer.