• 제목/요약/키워드: flux data

검색결과 1,545건 처리시간 0.026초

수치해석 방법을적용한 BLDC 전동기의 역기전력 연구 (A Study on Back EMF of BLDC Motor Using Numetical Analysis Method)

  • 김현철
    • 한국안전학회지
    • /
    • 제23권4호
    • /
    • pp.36-41
    • /
    • 2008
  • This report describes the analytical solution of back EMF for BLDC motor using numerical analysis of air gap flux density. The analysis of air gap flux density is the key to expect the performance of back EMF for the design of brushless motor. The numerical analysis and FEM analysis are performed to vary attachment of stator side or rotor side, radial flux magnetization or parallel flux magnetization, magnet arc angle in the condition of constant air gap. This results have more reliable data comparing with test result of the back EMF for 7 phase BLDC motor.

발사체 열부하 예측을 위한 태양열 모델 개발 (Development of a solar flux model for thermal load prediction of a launch vehicle)

  • 김성룡;김인선
    • 한국항공우주학회지
    • /
    • 제35권9호
    • /
    • pp.826-835
    • /
    • 2007
  • 발사체 열환경 설계를 위해서 여러 종류의 태양열 모델을 비교 검토하였으며, 측정된 태양열과 잘 일치하는 태양열 모델을 개발하였다. 기존의 태양열 모델은 태양 직사광 예측은 정확하지만 산란광에 대해서는 오차가 포함되어 있었다. 이에 반하여 새롭게 개발된 산란광 모델은 등방성, 이방성 산란을 고려하였으며 기존의 어느 모델보다 관측값과 잘 일치하였다. 우주 센터의 태양광 측정 데이터가 매우 적기 때문에 본 모델은 발사체 열하중 설계에 필요한 설계 데이터를 제공할 수 있었다. 또한 본 모델은 위도, 경도, 날짜, 고도에 대한 제한이 없는 일반적인 모델이기 때문에 추후 태양열에 민감한 반응을 보이는 비행기구 등의 개발에 효과적인 열환경 예측 수단을 제공할 수 있다.

알루미늄 다채널 압출관 내 R-22 대류 비등에 관한 실험 연구 (Experimental Investigation on Flow Boiling of R-22 in a Alumium Extruded Tube)

  • 심용섭;민창근;이응렬;신태룡;김내현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1340-1345
    • /
    • 2004
  • Convective boiling heat transfer coefficients of R-22 were obtained in a flat extruded aluminum tube with $D_h=1.41mm$ . The test range covered mass flux from 200 to 600 $kg/m^2s$, heat flux from 5 to 15 $kW/m^2$ and saturation temperature from $5^{\circ}C$ to $15^{\circ}C$ . The heat transfer coefficient curve shows a decreasing trend after a certain quality(critical quality). The critical quality decreases as the heat flux increases, and as the mass flux decreases. The early dryout at a high heat flux results in a unique 'cross-over' of the heat transfer coefficient curves. The heat transfer coefficient increases as the mass flux increases. At a low quality region, however, the effect of mass flux is not prominent. The heat transfer coefficient increases as the saturation temperature increases. The effect of saturation temperature, however, diminishes as the heat flux decreases. Both the Shah and the Kandlikar correlations underpredict the low mass flux and overpredict the high mass flux data.

  • PDF

Flow Boiling Heat Transfer of R-22 in a Flat Extruded Aluminum Multi-Port Tube

  • Kim Nae-Hyun;Sim Yang-Sup;Min Chang-Keun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권3호
    • /
    • pp.148-157
    • /
    • 2004
  • Convective boiling heat transfer coefficients of R-22 were obtained in a flat extruded aluminum tube with $D_h=1.41mm$. The test range covered mass flux from 200 to $600kg/m^{2}s$, heat flux from 5 to $15kW/m^2$ and saturation temperature from $5^{\circ}C\;to\;15^{\circ}C$. The heat transfer coefficient curve shows a decreasing trend after a certain quality (critical quality). The critical quality decreases as the heat flux increases, and as the mass flux decreases. The early dryout at a high heat flux results in a unique 'cross-over' of the heat transfer coefficient curves. The heat transfer coefficient increases as the mass flux increases. At a low quality region, however, the effect of mass flux is not prominent. The heat transfer coefficient increases as the saturation temperature increases. The effect of saturation temperature, however, diminishes as the heat flux decreases. Both the Shah and the Kandlikar correlations un-derpredict the low mass flux and overpredict the high mass flux data.

핵연료집합체 지지격자의 혼합날개 형상이 임계열유속에 미치는 영향 (Effect of Mixing Vane Shapes of Spacer Grids in Nuclear Fuel Assembly on Critical Heat Flux)

  • 신창환;추연준;문상기;천세영;전태현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2396-2401
    • /
    • 2007
  • Freon CHF experiments are carried out to investigate the CHF enhancements by mixing vane shapes of spacer grids in nuclear fuel assembly. The experiments were performed for a wide range mass flux, 50$\sim}$3000 kg/$m^2s$. Three kinds of spacer grids in 5${\times}$5 rod bundles are tested: no mixing vane grids, hybrid mixing vane grids, and split mixing vane grids. The CHF performances are compared along with the data belong to the PWR operating conditions based on a water equivalence through a fluid-to-fluid modeling method. The average of the data in this range is 16.4% for 37 data of hybrid vane grid and 12.5% for 24 data of split vane. In the lower mass flux, however, the split vane grid shows slightly higher performance than the hybrid vane grid.

  • PDF

Experimental Study and Correlation Development of Critical Heat Flux under Low Pressure and Low Flow Condition

  • Kim, Hong-Chae;Baek, Won-Pil;Kim, Han-Kon;Chang, Soon-Heung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.356-361
    • /
    • 1997
  • To investigate parametric effect on CHF and to get CHF data, experimental study has been performed with vertical round tubes under the condition of low pressure and low flow (LPLF). Test sections are made of Inconel-625 tube and have the geometry of 8 and 10 mm in diameter, and 0.5 and 1.0 m in heated length. All experiments have been conducted at the pressure of under 9 bar, the mass flux of under 250 kg/$m^2$ and the inlet subcooling of 350 and 450 kJ/kg, for stable upward flow with water as a coolant. Flow regime analysis has been performed for obtained CHF data with Mishima's flow regime map, which reveals that most of the CHF occur in the annular-mist flow regime. General parametric trends of the collected CHF data are consistent with those of previous studies. However, for the pressure effect on CHF, two different are observed; For relatively high mass flux, CHF increases with pressure and far lower mass flux, CHF decrease with pressure. Using modern data regression tool, ACE algorithm, two new CHF correlations for LPLF condition are developed based on local condition and inlet condition, respectively. The developed CHF correlations show better prediction accuracy compared with existing CHF prediction methods.

  • PDF

정유량 막여과 파울링 모델을 이용한 막여과 정수 플랜트 공정 진단 기법 (A process diagnosis method for membrane water treatment plant using a constant flux membrane fouling model)

  • 김수한
    • 상하수도학회지
    • /
    • 제27권1호
    • /
    • pp.139-146
    • /
    • 2013
  • A process diagnosis method for membrane water treatment plant was developed using a constant flux membrane fouling model. This diagnosis method can be applied to a real-field membrane-based water treatment plant as an early alarming system for membrane fouling. The constant flux membrane fouling model was based on the simplest equation form to describe change in trans-membrane pressure (TMP) during the filtration cycle from a literature. The model was verified using a pilot-scale microfiltraton (MF) plant with two commercial MF membrane modules (72 m2 of membrane area). The predicted TMP data were produced using the model, where the modeling parameters were obtained by the least square method using the early plant data and modeling equations. The diagnosis was carried out by comparing the predicted TMP data (as baseline) and real plant data. As a result of the case study, the diagnsis method worked pretty well to predict the early points where fouling started to occur.

STUDY OF SPECTRAL ENERGY DISTRIBUTION OF GALAXIES WITH PRINCIPAL COMPONENT ANALYSIS

  • Kochi, Chihiro;Nakagawa, Takao;Isobe, Naoki;Shirahata, Mai;Yano, Kenichi;Baba, Shunsuke
    • 천문학논총
    • /
    • 제32권1호
    • /
    • pp.209-211
    • /
    • 2017
  • We performed Principle Component Analysis (PCA) over 264 galaxies in the IRAS Revised Bright Galaxy Sample (Sanders et al., 2003) using 12, 25, 60 and $100{\mu}m$ flux data observed by IRAS and 9, 18, 65, 90 and $140{\mu}m$ flux data observed by AKARI. We found that (i)the first principle component was largely contributed by infrared to visible flux ratio, (ii)the second principal component was largely contributed by the flux ratio between IRAS and AKARI, (iii)the third principle component was largely contributed by infrared colors.

Locating Mechanical Damages Using Magnetic Flux Leakage Inspection in Gas Pipeline System

  • Kim, Jae-Joon
    • 비파괴검사학회지
    • /
    • 제30권6호
    • /
    • pp.521-526
    • /
    • 2010
  • Gas transmission pipelines are often inspected and monitored using the magnetic flux leakage method. An inspection vehicle known as a "pig" is launched into the pipeline and conveyed along the pipe by the pressure of natural gas. The pig contains a magnetizer, an array of sensors and a microprocessor-based data acquisition system for logging data. This paper describes magnetic flux leakage (MFL) signal processing used for detecting mechanical damages during an in-line inspection. The overall approach employs noise removal and clustering technique. The proposed method is computationally efficient and can easily be implemented. Results are presented and verified by field tests from an application of the signal processing.

평활관군의 R-134a 흐름비등에 관한 연구 (R-134a Flow Boiling on a Plain Tube Bundle)

  • 김종원;김정오;김내현
    • 설비공학논문집
    • /
    • 제13권1호
    • /
    • pp.9-17
    • /
    • 2001
  • In this study, flow boiling experiments were performed using R-134a on a plain tube bundle. Tests were conducted for the following range of variables; quality from 0.1 to 0.9, mass flux from $8\;kg/m^2s$ to $26\;kg/m^2s$ and heat flux from $10\;kW/m^2s$ to $40\;kW/m^2s$. The heat transfer coefficients were strongly dependent on the heat flux. However, they were almost independent on the mass flux or quality. The data are compared with the modified Chen model, which satisfactorily () predicted the data. Original Chen model, however, did not adequately predict the effect of quality. The reason may be attributed to the flow pattern of the present test, where the bubbly flow prevailed for the entire test range. The heat transfer coefficients of the tube bundle were 6~40% higher than those of the single tube pool boiling.

  • PDF