• 제목/요약/키워드: flux angle

검색결과 508건 처리시간 0.026초

Comparison of geometrical methods to identify CME 3-D structures

  • Lee, Harim;Moon, Yong-Jae;Na, Hyeonock;Jang, Soojeong
    • 천문학회보
    • /
    • 제39권1호
    • /
    • pp.73-73
    • /
    • 2014
  • Several geometrical models (e.g., cone and flux rope models) have been suggested to infer 3-D parameters of CMEs using multi-view observations (STEREO/SECCHI) and single-view observations (SOHO/LASCO). To prepare for when only single view observations are available, we have made a test whether the cone model parameters from single-view observations are consistent with those from multi-view ones. For this test, we select 35 CMEs which are identified as CMEs, whose angular widths are larger than 180 degrees, by one spacecraft and as limb CMEs by the other ones. For this we use SOHO/LASCO and STEREO/SECCHI data during the period from 2010 December to 2011 July when two spacecraft were separated by $90{\pm}10$ degrees. In this study, we compare 3-D parameters of these CMEs from three different methods: (1) a triangulation method using the STEREO/SECCHI and SOHO/LASCO data, (2) a Graduated Cylindrical Shell (GCS) flux rope model using the STEREO/SECCHI data, and (3) an ice cream cone model using the SOHO/LASCO data. The parameters used for comparison are radial velocities, angular widths and source location (angle ${\gamma}$ between the propagation direction and the plan of the sky). We find that the radial velocities and the ${\gamma}$-values from three methods are well correlated with one another (CC > 0.8). However, angular widths from the three methods are somewhat different. The correlation coefficients are relatively not good (CC > 0.4). We also find that the correlation coefficients between the locations from the three methods and the active region locations are larger than 0.9, implying that most of the CMEs are radially ejected.

  • PDF

Racemic and enantiomeric effect of tartaric acid on the hydrophilicity of polysulfone membrane

  • Sharma, Nilay;Purkait, Mihir Kumar
    • Membrane and Water Treatment
    • /
    • 제7권3호
    • /
    • pp.257-275
    • /
    • 2016
  • The enantiomeric and racemic effects of tartaric acid (TA) on the properties of polysulfone (PSn) ultrafiltration membranes were studied in terms of morphology and hydrophilicity (HPCT) of membrane. Asymmetric membranes were prepared by direct blending of polyvinyl pyrrolidone (PVP) with D-TA and DL-TA in membrane casting solution. FTIR analysis was done for the confirmation of the reaction of PVP and TA in blended membranes and plain PSn membranes. Scanning electron microscope (SEM), field emission scanning electron microscope (FESEM) and atomic force microscopy (AFM) were used for analyzing the morphology and structure of the resulting membranes. The membranes were characterized in terms of pure water flux (PWF), hydraulic permeability and HPCT. PWF increased from $52L/m^2h$ to $79.9L/m^2h$ for plain and D-TA containing PSn membrane, respectively. Water contact angle also found to be decreased from $68^{\circ}$ to $55^{\circ}$. In Additionally, permeation and rejection behavior of prepared membranes was studied by bovine serum albumin (BSA) solution. A considerable increase in BSA flux (from $19.1L/m^2h$ for plain membrane to $32.1L/m^2h$ for D-TA containing membrane) was observed. FESEM images affirm that the pore size of the membranes decreases and the membrane permeability increases from 0.16 to 0.32 by the addition of D-TA in the membrane. D-TA increases the HPCT whereas; DL-TA decreases the HPCT of PSn membrane. PVP (average molecular weight of 40000 Da) with D-TA (1 wt%) gave best performance among all the membranes for each parameter.

A Inclined Slot-excited Circular Plasma Source with a Cusp Magnetic Field

  • You, H.J.;Kim, D.W.;Koo, M.;Jang, S.W.;Jung, Y.H.;Lee, B.J.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.435-435
    • /
    • 2010
  • A inclined slot-excited plasma source is newly designed and constructed for higher flux HNB(Hyperthermal Neutral Beam) generation. The present source is different from the vertical SLAN(SLot ANtenna) sources [1] in two aspects. One is that the slots are inclined, and the other is that the magnetic field is configured to a cusp type. These modifications are intended to make the source plasma operated in sub-milli-torr pressure regime and as thin as possible, both of which is to get higher HNB flux by decreasing the re-ionization rate of the reflected atoms from the neutralizer [2]. The plasma is generated in a quartz tube of internal diameter 170 mm enclosed in a aluminum application chamber of larger diameter 250 mm. The microwave power is fed to the plasma chamber by 8 inclined slots cut into the application chamber wall. The slots are coupled the chamber to a WR280 waveguide wound around it to form a ring resonator. In order to make two slots $\lambda_g/2$ apart in phase, the adjacent slots are rotated in opposite directions. The rotation angle of the slots are set to $60^{\circ}$ from the chamber axis. Between the quartz chamber and the aluminum cylindrical chamber 8 NdFeB magnets are equally spaced and fixed to form the cusp magnetic field confinement and ECR (Electron Cyclotron Resonance) field. In this presentation, the magnetic and electromagnetic simulations, and the measured plasma parameters are given for both the inclined and the vertical slot-excited plasma sources. We also discuss how the sources can be tailored to suit better-performing HNB sources.

  • PDF

A study on membrane technology for surface water treatment: Synthesis, characterization and performance test

  • Haan, Teow Yeit;Shah, Mubassir;Chun, Ho Kah;Mohammad, Abdul Wahab
    • Membrane and Water Treatment
    • /
    • 제9권2호
    • /
    • pp.69-77
    • /
    • 2018
  • The use of membrane as an innovative technology for water treatment process has now widely been accepted and adopted to replace the conventional water treatment process in increasing fresh water production for various domestic and industrial purposes. In this study, ultrafiltration (UF) membranes with different formulation were fabricated via phase inversion method. The membranes were fabricated by varying the polymer concentration (16 wt%, 18 wt%, 20 wt%, and 21 wt%). A series of tests, such as field emission scanning electron microscope (FESEM), pore size and porosity, contact angle, and zeta potential were performed to characterize the membranes. The membrane performance in terms of permeation flux and rejection were evaluated using a laboratory bench-scale test unit with mine water, lake water and tube well as model feed solution. Long hour filtration study of the membranes provides the information on its fouling property. Few pore blocking mechanism models were proposed to examine the behaviour of flux reduction and to estimate the fouling parameters based on different degree of fouling. 21 wt% PVDF membrane with smaller membrane pore size showed an excellent performance for surface water treatment in which the treated water complied with NWQS class II standard.

이산화탄소 분리용 세라믹 중공사 접촉막 모듈 기술 개발 (Development of Ceramic Hollow Fiber Membrane Contactor Modules for Carbon Dioxide Separation)

  • 이홍주;채진웅;박정훈
    • 한국기후변화학회지
    • /
    • 제7권3호
    • /
    • pp.249-256
    • /
    • 2016
  • Porous $Al_2O_3$ hollow fiber membranes were successfully prepared by dry-wet spinning/sintering method. The SEM image shows that the $Al_2O_3$ hollow fiber membrane consists mostly of sponge pore structure. The contact angle and the breakthrough pressure were $126^{\circ}$ and 1.91 bar, respectively. This results indicate that the $Al_2O_3$ hollow fiber membranes were successfully modified to hydrophobic surface. The hydrophobic modified $Al_2O_3$ hollow fiber membranes were assembled into a membrane contactor system to separate $CO_2$ from a model gas mixture of the flue gas at elevated gas velocity. The $CO_2$ absorption flux was enhanced when the gas velocity increased from $1{\times}10^{-3}$ to $6{\times}10^{-3}$ m/s. Whereas the $CO_2$ absorption flux was decreased with the number of hollow fiber membrane of a module because of the concentration polarization. Furthermore, we developed an lab-scale $Al_2O_3$ hollow fiber membrane contactor modules and their system (i.e., $CO_2$ absorption using the $Al_2O_3$ membrane and monoethanolamine (MEA)) that could dispose of over $0.02Nm^3/h$ mixture gas (15% $CO_2$) with the removal efficiency higher than 95%. The results can be useful in a field of the membrane contactor for $CO_2$ separation, helping to design and extend a equipment.

Characterization and performance of post treated PVDF hollow fiber membrane

  • Eman S. Sayed;Hayam F. Shaalan;Magda I. Marzouk;Heba A. Hani
    • Membrane and Water Treatment
    • /
    • 제15권2호
    • /
    • pp.79-88
    • /
    • 2024
  • Modification of Polyvinylidene fluoride (PVDF) hollow fiber membranes (HFMs) characteristics and performance were investigated via post treatment using different oxidants. sodium hypochlorite (NaOCl), hydrogen peroxide (H2O2) and potassium persulfate (KPS). Fourier transform infrared (FTIR) and Proton nuclear magnetic resonance (1H-NMR) results revealed no structural differences after post treatment. Cross-sectional micrographs show finger-like structures at the outer and inner walls of the HFMs and sponge-like structures in middle, where NaOCl and KPS post treated fibers exhibited a decrease in finger-like structures in addition to aggregates appearing on the surface, consequently leading to an increase in the surface roughness (Ra) from 48 nm to 52.8nm and 56 nm, respectively. Hydrogen peroxide post treatment only was observed to decrease the water contact angle from 98° to 81.4°. It was also observed that the elongation at break and the modulus deceased after NaOCl post treatment from 34.5 to 28.5% and from 19.3 Mpa to 16.6 Mpa, respectively. Moreover, pure water flux after H2O2 post treatment increased from 87.8 LMH/bar to 113 LMH/bar at 0.45 bar, while no changes were detected for the methylene blue dye rejection (74%) between raw and hydrogen peroxide post treated fibers at the same pressure. According to the findings hydrogen peroxide post treated PVDF HFMs have the most uniform surfaces, with almost no alterations in structural and mechanical properties or porosities with enhanced hydrophilicity and pure water flux maintaining appropriate rejection. Therefore, it is considered an efficient surface modifying agent for UF/NF membranes or low-pressure separators.

포항방사광가속기의 다극 위글러용 고 열량부하 슬릿 (High Heat-load Slits for the PLS Multi-pole Wiggler)

  • 길계환;김창균;정진화
    • 한국진공학회지
    • /
    • 제16권1호
    • /
    • pp.46-51
    • /
    • 2007
  • 포항가속기연구소의 HFMX(High Flux Macromolecular X-ray crystallography) 빔라인은 다극 위글러의 방사광을 이용한다. 따라서 고 열량부하에 적합한 두 개의 수평 및 수직 슬릿이 빔라인의 프론트엔드 영역에 설치되었다. 빔 산란을 피하면서 고 열량부하를 처리하기 위하여, 빔을 차단하는 수평 슬릿의 두 글리드콥 블록은 수직면 상에서 기울어진, $10^{\circ}$의 스침각 경사면 구조를 이루고 있다. 글리드콥 블록들은 두 개의 구동막대에 의해서 궤도대를 따라 각각 병진함으로써 슬릿의 간격을 조정한다. 구동막대 내부에 가공된 유로를 통하여 흐르는 냉각수가 두 블록의 열량부하를 냉각시킨다. 수직 슬릿은 진공용기에 대한 설치 방향과 스침각 경사면 구조의 경사각만 다를 뿐 수평 슬릿과 동일한 구조를 가지고 있다. 블록들이 궤도대 상에서 정밀하게 조정되므로 두 블록 간의 정렬이 필요치 않은 장점이 있으며 설치된 슬릿들은 안정적인 작동 성능을 보이고 있다. 또한, 두 슬릿의 냉각 성능도 만족할 만한 것으로 나타났다. 본 논문에서는 두 슬릿의 설계에 대한 상세한 설명이 제시되고 그 작동 성능을 검토한다.

$PES-TiO_2$ 복합막의 제조 및 막 특성 평가 (Preparation of $PES-TiO_2$ Hybrid Membranes and Evaluation of Membrane Properties)

  • 염경호;이미선
    • 멤브레인
    • /
    • 제17권3호
    • /
    • pp.219-232
    • /
    • 2007
  • 침지침강 상변환법으로 폴리에테르설폰$(PES)-TiO_2$ 복합막을 제조하였다. 14 wt% 및 20 wt%의 PES/NMP 기준 고분자 용액에 $TiO_2$ 나노입자를 PES에 대해 $0{\sim}60$ wt%로 첨가량을 달리하여 복합막 제조에 사용될 캐스팅 용액을 준비하였다. 제조된 $PES-TiO_2$ 복합막의 막 특성과 몰폴로지를 $TiO_2$ 첨가량에 따른 캐스팅 용액의 점도, coagulation value, 광투과도와 복합막의 인장강도, 세공크기 및 접촉각, 표면 및 단면 SEM 사진, BSA 용액의 한외여과 실험을 통해 규명하였다. 캐스팅 용액에 첨가시킨 $TiO_2$ 입자의 함유량이 증가함에 따라 점도는 증가하고 coagulation value는 낮아져 캐스팅 용액의 열역학적 불안정성이 증가하였다. $TiO_2$ 입자의 첨가량이 증가함에 따라 1) 순간분리의 침강형식을 유지하면서 침강속도가 빨라졌으며, 2) 순수투과량, 세공크기 및 압밀화 안정성이 증가하며, 3) 인장강도와 접촉각은 감소하였다. $PES-TiO_2$ 복합막의 BSA 용액에 대한 전량여과식 한외여과 실험결과 $TiO_2$ 입자의 함유량이 증가함에 따라 막의 친수화 특성이 증가하여 투과플럭스가 증가하였으며, $TiO_2$가 첨가되지 않은 막과 비교하여 최대 7배까지 투과 플럭스가 향상되었다.

유도전동기의 강건한 저속 제어를 위한 단위각 보상 벡터 제어 (The Vector Control with Compensating Unit Angle for the Robust Low Speed Control of Induction Motor)

  • 원영진;박진홍
    • 전자공학회논문지T
    • /
    • 제35T권1호
    • /
    • pp.90-98
    • /
    • 1998
  • 본 논문은 유도전동기를 저속에서 강건하게 제어할 수 있도록 개선된 벡터 제어에 관한 연구이다. 유도전동 기가 정격 속도의 10% 이하인 저속에서 구동될 경우 고조파에 의하여 발생하는 단위 벡터각 오차를 보상하는 알고리즘을 제안하였다. 또한 저속 및 과도상태에서 회전자 파라미터 변화에 대하여 강건하게 운전하도록 회전 자 시정수에 동조하는 알고리즘을 제시하였다. 제안한 벡터 제어를 이용하여 자속과 토오크 리플을 감소시킴으로써 저속에서 안정된 출력특성을 얻을 수 있었다. 입출력이 정현적인 상태일 때, 제안한 벡터 제어와 직접 벡터 제어 및 간접 벡터 제어의 저속 특성을 비교 분석하였고, 고조파가 함유된 상태에서 각각의 제어 특성을 비교 분석하였다. 그리고 회전자 시정수의 추종 성능은 시뮬레이션으로 확인하였다. 전체 제어 시스템을 실제의 하드웨어로 구현하고, 제안한 벡터 제어와 직접 벡터 제어를 비교 분석하였다. 두 제어 기법을 저속에서 실험 한 결과, 정상상태에서 직접 벡터를 기준으로 할 경우 토오크 리플이 45% 개선된 특성을 얻었다. 또한 자속 전류 리플은 0.2 p.u. 감소하였고, 토오크 전류 리플은 0.6 p.u. 감소함을 확인하였다. 그리고 회전자 시정수의 변화에 대하여 동조됨을 확인하였다. 따라서 저속에서 제안한 벡터 제어의 타당성과 강건성을 입증하였다.

  • PDF

고속탄자 유동의 가시화 실험 및 비정렬격자 계산 (Flow Visualization and Unstructured Grid Computation of Flow over a High-Speed Projectile)

  • 이상길;최서원;강준구;임홍규;백영호;김두연;강호철
    • 한국자동차공학회논문집
    • /
    • 제6권2호
    • /
    • pp.12-20
    • /
    • 1998
  • Exter ballistics of a typical high-speed projectile is studied through a flow-visualization experiment and an unstructured grid Navier-Srokes computation. Experiment produced a schlieren photograph that adequately shows the characteristic features of this complex flow, namely two kinds of oblique cone shocks and turbulent wake developing into the downstream. A hybrid scheme of finite volume-element method is used to simulate the compressible Reynolds-Averaged Navier-Stok- es solution on unstructured grids. Osher's approximate Riemann solver is used to discretize the cinvection term. Higher-order spatial accuracy is obtained by MUSCL extension and van Albada ty- pe flux limiter is used to stabilize the numerical oscillation near the solution discontinuity. Accurate Gakerkin method is used to discretize the viscous term. Explict fourth-order Runge-Kutta method is used for the time-stepping, which simplifies the application of MUSCL extension. A two-layer k-$\varepsilon$ turbulence model is used to simulate the turbulent wakes accurately. Axisymmetric folw and two-dimensional flow with an angle of attack have been computed. Grid-dependency is also checked by carrying out the computation with doubled meshes. 2-D calculation shows that effect of angle of attack on the flow field is negligible. Axi-symmetric results of the computation agrees well with the flow visualization. Primary oblique shock is represented within 2-3 meshes in numerical results, and the varicose mode of the vortex shedding is clearly captured in the turbulent wake region.

  • PDF