• 제목/요약/키워드: flushing rate

검색결과 105건 처리시간 0.022초

환경친화적 항만건설을 위한 항내 희석률 예측 (Prediction of a Flushing Rate in an Embayment System for Construction of an Environmentally Sound Harbor)

  • 정미훈;박석순
    • 환경영향평가
    • /
    • 제9권3호
    • /
    • pp.215-228
    • /
    • 2000
  • This paper presents a novel method to predict a flushing rate in an embayment system, which can be utilized to assess an environmental impact caused by harbor construction. The method was successfully applied to the Ulsan-Onsan coastal area. The flushing rate was computed on the basis of water quality changes predicted by US Army Corps of Engineers' RMA-2/RMA-4 models. After calibration and verification to the measured tidal elevation and current velocity, the model was used to estimate the flushing rate in the proposed harbor. The water quality was simulated for 96 hours and the flushing rate was computed. The results indicated that the proposed harbor would significantly reduce the flushing rate in the Onsan harbor, especially at the small embayment area near the south breakwater. The flushing rate was evaluated for several alternatives, of which the tidal flow channel of 1,000 $m^2$ in the south pier appeared to be the best mitigation measure. This study proposes that the prediction of flushing rate would be a novel method to assess a water quality impact caused by harbor construction.

  • PDF

원위치 토양세척 공정의 효율향상을 위한 세제선정과 운전기법 (Selection of Surfactant and Operation Scheme for Improved Efficiency of In-situ Soil Flushing Process)

  • 손봉호;임봉수;어성욱;이병호
    • 한국물환경학회지
    • /
    • 제22권5호
    • /
    • pp.824-830
    • /
    • 2006
  • Several tests were conducted to optimize the design parameters of ln-situ soil flushing processes for diesel contaminated soil. According to the batch extraction test for three anionic surfactants evaluation, Calgonit limiting bubble occurrence was selected for its higher oil cleaning efficiency. After optimum surfactant selection, there were many sets of column flushing test. Over 70% of BTEX was removed in this surfactant dose with 400% of soil volume. In the case of no surfactant addition flushing in column, so called "blank flushing test", BTEX removal rate was 64%. But when we reused the effluent for the cleaning solution, the removal rate was decreased to 46.9%. This result showed reabsorption of oil occurred on the soil. With the addition of Calgonit solution to the diesel contaminated column, BTEX was removed up to 98.9% during the first flushing and 99.4% for the second recirculation flushing. In microcosm tests, diesel contaminated soils were cleaned by both surfactant flushing and biological activities. In anoxic condition, nitrate was used as an electron acceptor while the surfactant and the oil were used an electron donor. BTEX removal efficiency could be achieved up to 80% by biological degradation.

파키스탄 파트린드댐의 저수지 퇴사관리를 위한 배사효과 분석 (Analysis of Sediment Flushing Effect for Reservoir Sedimentation Management of the Patrind Dam in Pakistan)

  • 노준우;박진혁;허영택;김상호
    • 한국물환경학회지
    • /
    • 제29권6호
    • /
    • pp.799-807
    • /
    • 2013
  • Reservoir sedimentation is one of the major concerns for sustainable reservoir operation. Since sediment concentration of the rivers in the Himalayan Mountain is very high, a proper sediment management scheme is necessary. This paper presents long-term reservoir sedimentation and sediment flushing based on the gate operation. Focused on the reservoir to be constructed for the Patrind hydropower project in Pakistan, 4 different flushing scenarios were proposed in this study to prevent successive sedimentation. By extending flushing period and by increasing the flushing discharge for 2 times, the flushing rate increases up to 53.2% and 43.6% in proportion to flushing period and discharge, respectively. Based on the simulation presented in this paper, it is expected to establish efficient sediment management plan to increase hydro power generation and sediment flushing simultaneously.

유압시스템 롤-오프 청정도의 이론적 고찰 및 트랙터에의 응용 (A Theoretical Investigation of Roll-Off Cleanliness for Hydraulic System and Application to a Tractor)

  • 이재천
    • 한국자동차공학회논문집
    • /
    • 제8권5호
    • /
    • pp.207-215
    • /
    • 2000
  • This study theoretically investigated the roll-off cleanliness operation to eliminate the built-in contaminants which are primarily the result of manufacturing and assembly procedures first. A rigorous analytical examination of the cleaning process associated with hydraulic systems was performed by developing the general filtration process equations. The sloughing process by which built-in contaminant is entrained in the system fluid was examined during the development of a general analytical expression for sloughing rate. This sloughing rate expression in conjunction with the filtration process equations have lead to a relationship rate expression in conjunction with the filtration process equations have lead to a relationship which describes the flushing and clean-up operation for the hydraulic systems. The effects of the primary roll-off cleanliness factors was discussed and illustrated on the figures. Then, the analytical results was shown to be usefully applied into the design of roll-off flushing equipment for the hydraulic system of a tractor.

  • PDF

토양의 종류에 따른 초음파토양세척의 투수특성 분석

  • 정하익;송봉준;이용수;유준;강동우
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.258-261
    • /
    • 2004
  • In this study, the combined electrokinetic and ultrasonic remediation technique onto simple soil flushing was studied for the enhancement of water and liquid flows and the removal of contaminants in contaminated soils. The ultrasonic technique has been used to increase liquid flow and remove pollutants in contaminated soil. The laboratory soil flushing tests combined electrokinetic and ultrasonic technique were conducted using specially designed and fabricated devices to determine the effect of these both techniques. A series of laboratory permeability experiments involving the simple, electrokinetic, ultrasonic, and electrokinetic & ultrasonic flushing test were carried out. A soil admixed with sand and kaolin was used as a test specimen, and Pb and ethylene glycol were used as contaminants. An increase in out flow, permeability and contaminant removal rate was observed in electrokinetic and ultrasonic flushing tests.

  • PDF

In-Situ Flushing기법이 Endosulfan으로 오염된 토양의 생물학적 처리에 미치는 영향 (Effects of In-Situ flushing on the Bioremediation of Soil Contaminated with Endosulfan)

  • 전민하;최상일
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제6권2호
    • /
    • pp.39-47
    • /
    • 2001
  • 회분식 세척실험에서 적용된 혼합계면활성제 중 $POE_5$ + $POE_14$, SDS+$POE_5$가 endosulfan의 탈착에 효율이 우수한 것으로 나타났으며, 독성실험 결과 SDS+POE$_{5}$는 미생물의 활성을 다소 저해시키는 경향이 있어 $POE_5$ + $POE_14$ (1:1) 1%를 세척제로 선정하였다. In-Situ flushing 실험에서는 세척용액의 주입 flux가 1.5L/min/m$^2$일 때 67%의 제거효율을 얻을 수 있었으며, 보조용매로서 메탄올과 에탄올을 첨가한 경우에는 각각 75%와 81%의 제거효율을 보였다. In-situ flushing기법의 적용에 따른 농도 저감이 생물학적 분해에 미치는 영향을 알아보기 위하여, 초기 농도 13mg/kg dry soil과 3mg/kg dry soil인 토양을 생물학적으로 처리한 결과 제거 효율은 각각 86% 및 81%였으며, 2가지 토양 모두 24시간 이후에는 미생물에 의한 작용이 크지 않은 것으로 나타났다. 이것은 토양상에서 용액상으로의 물질전이 속도가 율속 단계로 작용하고 있기 때문이라 판단된다. 토양에 잔류하는 계면활성제가 생물학적 분해에 미치는 영향에 대하여 검토한 결과, 잔류하는 계면활성제에 의해 물질전이 속도가 향상되어 생분해가 지속적으로 일어났으며 초기 농도 3mg/kg dry soil인 경우 120시간이 경과한 후 89%의 제거효율을 나타내었다. 계면활성제와 보조용매가 동시에 잔류하는 경우에는 계면활성제에 대한 순응기간이 보다 길어지는 것을 알 수 있었으며, 메탄올과 에탄올의 경우 각각 84% 및 83%의 제거효율을 나타내었다.

  • PDF

Transcervical Embryo Recovery in Korean Black Goats: A Preliminary Experiment

  • Lee, Doo-Soo;Kim, Dong-Woo;Shin, Sang Tae
    • 한국수정란이식학회지
    • /
    • 제30권3호
    • /
    • pp.171-174
    • /
    • 2015
  • Four pluriparous Korean black goat does were superovulated with FSH and mated with fertile bucks. Anesthetized animals were placed in lateral recumbency, then size 8 Foley catheter was inserted into the uterus through the cervix under the vaginal speculum and the balloon was inflated to fix the catheter in the uterine body. The opposite end of the catheter was connected to a 3-way and a flushing medium was infused into the uterus. Modified Dubecco's PBS with 1% FBS was used as the flushing medium. Four goats were allocated in two groups depending on the type of medium infusion into uterus. Injection group; the flushing medium was injected into uterus and the infused medium was collected by to-and-fro method using a syringe. Gravity-flow group; the flushing medium was allowed to enter the uterus by gravity flow by lifting the medium bottle and drained out of the uterus into a collecting tube. All four goats had catheter inserted through the cervix and uteri flushed successfully. The volume (recovery rate) of recovered medium varied considerably from 87 ml/200 ml (43.5%) to 148 ml/160 ml (92.5%). Nine embryos/ova in total were recovered from Gravity-flow group goats. Although the embryo recovery rate was low, the possibility of a transcervical embryo recovery in Korean black goat had been proven in this preliminary experiment.

한우에서 Direct Embryo Collection(DEC)을 이용한 체내 수정란의 회수율 분석 (Analysis of Embryo Recovery Rate by Direct Embryo Collection (DEC) in Korean Native Cattle (Hanwoo))

  • 유한준;박정준;윤필상;김기원;박춘근
    • 한국수정란이식학회지
    • /
    • 제26권3호
    • /
    • pp.159-164
    • /
    • 2011
  • This study was performed in order to determine optimum flushing solution using the direct embryo collection (DEC). Donors, at random stages of the estrous cycle, received a CIDR. 7 days later, 200 mg FSH was treated with 40, 30, 20, 10 mg FSH levels in declining doses twice daily by intramuscular injection for 4 days. On the 3$^{rd}$ day administration of FSH, 25 mg $PGF_2{\alpha}$ was administered and CIDR was withdrawn. After FSH injections were complete, donors were artificially inseminated twice at 12 hr intervals. The donor cattle received 250 ${\mu}g$ GnRH at time of 1$^{st}$ insemination and embryos were recovered 8 days after the 1$^{st}$ insemination. Embryo collection from superovulated donors were performed to flushing by DEC and conventional method. As a results, the average number of recovered embryos were significantly higher as 19.1${\pm}$1.40 with DEC method than 12.0${\pm}$0.44 with conventional embryo collection method, respectively (p<0.05). Also, The average number of transferable embryos were significantly higher (p<0.05) as 15.8${\pm}$1.72 with DEC method than 6.9${\pm}$0.35 from conventional embryo recovery procedures. Meanwhile, number of recovered embryos and number of recovered transferable embryos following the number of flushing times until 6${dr}$ flushing were significantly higher as 8.6${\pm}$0.53 and 8.6${\pm}$0.53 from 2$^{nd}$ flushing time than other groups (p<0.05). No. of Ear. B stage embryos were significantly higher as 3.9${\pm}$0.90 and 3.9${\pm}$0.90 with 2$^{nd}$ flushing time in total collected embryos and transferable embryos (p<0.05). Com M stage embryos were significantly higher as 3.7${\pm}$1.00 in 2$^{nd}$ flushing time and as 2.2${\pm}$0.76 in 3$^{rd}$ flushing time for recovered embryos (p<0.05). In transferable embryos, Com. M stage embryos were significantly higher (p<0.05) as 3.7${\pm}$1.00 in 2$^{nd}$ flushing time and as 2.2${\pm}$0.76 in 34$^{dr}$ flushing time, also. No. of degradation embryos was significantly higher as 2.2${\pm}$0.72 in 5${rd}$ flushing time, On the other hand, degradation embryos was not observed in transferable embryos (p<0.05). In conclusion, these results suggest that DEC method should effective methods for production of in vivo embryos using less flushing solution following perform until 4$^{rd}$ flushing time than conventional embryo collecting method. Also, it might be effectively collection of transferable embryos following more less procedure times compared to conventional embryo recovery methods.

Ultrasonic flushing 기법에 의한 유류오염토양의 복원에 관한 실험연구

  • 정하익;오인규;김상근;이용수;유준
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 총회 및 춘계학술발표회
    • /
    • pp.13-17
    • /
    • 2002
  • Ultrasonic waves have several mechanical, chemical, and biological effects on a saturated soil medium. Their mechanical effects, popularly known as cavitation. Cavitation is the rapid and repeated formation, and resulting implosion, of imcrobubbles in a liquid, resulting in the propagation of microscopic shock waves. In a soil-liquid system, their mechanical effects generate high differntial fluid-particle velocities and microscopic shock waves. The velocity perturbations are capable of dislodging oil in the system by overcoming the forces binding oil to sand particles. In this study, a series of laboratory experiments involving the simple flushing and ultrasonic flushing were carried out. An increase in permeability and oil removal rate were observed in ultrasonic flushing tests. Some practical implications of these results are discussed in terms of technical feasibility of in situ implementation of ultrasonics.

  • PDF

초음파동전기세척 복합기법에 의한 오염부지 복원기술

  • 정하익;김상근;송봉준;강동우;이경국
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.183-185
    • /
    • 2004
  • In this study, the combined electrokinetic and ultrasonic remediation technique, ultrasonically enhanced electrokinetic technique, was studied for the removal of heavy metal and organic substance in contaminated soils. The electrokinetic technique has been applied to remove mainly the heavy metal and the ultrasonic technique has been to remove mainly organic substance in contaminated soil. The laboratory soil flushing tests combined electrokinetic and ultrasonic technique were conducted using specially designed and fabricated devices to determine the effect of these both techniques. A series of laboratory experiments involving the simple, electrokinetic, ultrasonic, and electrokinetic & ultrasonic flushing test were carried out. A soil admixed with sand and kaolin was used as a test specimen, and Pb and ethylene glycol were used as contaminants of heavy metal and organic substance. An increase in out flow, permeability and contaminant removal rate was observed in electrokinetic and ultrasonic flushing tests. Some practical implications of these results are discussed in terms of technical feasibility of in situ implementation of electrokinetic ultrasonic remediation technique.

  • PDF