• 제목/요약/키워드: flushing

Search Result 547, Processing Time 0.034 seconds

Evaluation of Rainwater Utilization for Miscellaneous Water Demands in Different Types of Buildings Using Geographic Information System

  • Kim, Jinyoung;An, Kyoungjin;Furumai, Hiroaki
    • Environmental Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.85-90
    • /
    • 2013
  • This study is an attempt to quantify rainwater utilization and miscellaneous water demand in Tokyo's 23 special wards, the core of the urban area in Tokyo, Japan, in order to elucidate the potential of further rainwater utilization. The rainwater utilization for miscellaneous appropriate water demands, including toilet flushing, air conditioning, and garden irrigation, were calculated for six different types of building: residential house, office, department store, supermarket, restaurant, and accommodation. Miscellaneous water demands in these different types of building were expressed in terms of equivalent rainfall of 767, 1,133, 3,318, 1,887, 16,574, and 2,227 (mm/yr), respectively, compared with 1,528 mm of Tokyo's average annual precipitation. Building types, numbers and its height were considered in this study area using geographic information system data to quantify miscellaneous water demands and the amount of rainwater utilization in each ward. Area precipitation-demand ratio was used to measure rainwater utilization potential for miscellaneous water demands. Office and commercial areas, such as Chiyoda ward, showed rainwater utilization potentials of <0.3, which was relatively low compared to those wards where many residential houses are located. This is attributed to the relatively high miscellaneous water demand. In light of rainwater utilization based on building level, the introduction of rainwater storage mechanisms with a storage depth of 50 mm for six different types of buildings was considered, and calculated as rainfall of 573, 679, 819, 766, 930, and 787 (mm), respectively. Total rainwater utilization using such storage facilities in each building from 23 wards resulted in the retention of 102,760,000 $m^3$ of water for use in miscellaneous applications annually, and this volume corresponded to 26.3% of annual miscellaneous water demand.

Sex Determination of Boving Embryos by Polymerase Chain Reaction (PCR 방법을 이용한 소 수정란의 성판별)

  • 황윤식;한용만;한용만;한용만;김정익;이경광
    • Korean Journal of Animal Reproduction
    • /
    • v.18 no.4
    • /
    • pp.275-284
    • /
    • 1995
  • In sexing early mammalian embryos, viability of biopsied embryos and accuracy of sexing are both important. We have been previously developed efficient methods for biopsy of mouse embryos and sex identification from a single blastomere by PCR. In this study, squeeze method used for biopsy of mouse embryos was applied to bovine embryos. Compact bovine morulae were obtained by flushing uteri on Day 6 after the onset of standing estrus. A small number of blastomeres could be isolated from bovine morulae by the biopsy method. All 13 biopsied morulae were survived and 10 embryos developed to normal blastocyst after 24 h of culture. Subsequently, sex of the bovien embryos was identified from a few blastomeres by PCR amplifying a Y-specific bovine DNA sequence. Among 13 embryos analyzed, 7 embryos were determined as males and 6 embryos as females. Thus, bovine embryos at morular stage could be successfully biopsied by the squeeze method and sex of the bovine embryos determined from biopsied material by PCR.

  • PDF

Comparing Night Soil Treatment Processes in Aspects of Cost and Energy Consumption (분뇨처리방법의 비용 및 에너지소비 비교)

  • Yoo, Kee Young
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.16 no.3
    • /
    • pp.38-45
    • /
    • 2008
  • There are still lots of areas where combined sewer pipes are covering in Seoul. All buildings within those areas are equipping septic tanks which take part in separating solids from flushing water of chamber pots. Septic tanks legally demand emptying and cleaning the those inner bodies once a year, resulting the generation of sludge which should be purified using the specified treatment plants as one of environmental infrastructures. Previous research showed that sludge volume continuously increase putting night soil treatment facilities in shortage by 3,549kL a day in 2020, which should be prepared by newly built facilities. This study aimed to define which process is more suitable especially in the points of cost and energy consumption. It was the main results that combining treatment of sewer with night soil, in fact same as nowaday process, is the very positive way beyond the treatment of night soil's own in respects of both costs and energy consumption.

  • PDF

Remediation of Contaminated Sites in Canada

  • Koo, Jahak
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1996.11a
    • /
    • pp.39-49
    • /
    • 1996
  • Hundreds of contaminated sites have been generated due to the past mismagement of toxic substances, the lack of adequate environmental controls and ignorance of the potential environmental impacts of general activities in Canada. The general public, industry and governments have been addressing the contaminated sites with a number of cleanup responses. Environmental protection and remediation have become top priorities for the public and private sectors alike in Canada. Between the late 1980s and the early 1990s, the Canadian Environmental Protection Act and Canada's Green Plan were followed by provincial and territorial laws and policies to regulate contaminated sites. The National Contaminated Site Remediation Program(NCSRP) was initiated in 1989. It has been administered through bilateral agreements between the federal and participating provincial/territorial governments. They have committed a total of $250 million toward orphan site cleanup and technology development/demonstration over a five year period. The federal government has committed an additional $25 million to assess contaminated sites on federal crown land. Over 40 orphan high-risk contaminated sites, over 230 federal sites and over 35 technology development/demonstration projects have been addressed. The Canadian Council of Ministers of the Environment has developed a series of guidance documents to ensure a consistent and successful implementation of the Program. The management/regulation scheme of contaminated sites generally consists of: 1) identifying and investigating sites, 2) determining site contamination, 3) recognizing responsibility and liability, 4) assessing priority for remediation, 5) activation, evaluation and implementing remediation options, and 6) documenting remediation completion. The NCSRP supported the successful development/demonstration of a wide range of innovative remedial technologies. They are related to stabilization/solidification, thermal washing/flushing, advanced oxidation, sonics, and groundwater contaminated with hydrocarbons, PAHS, PCBs, heavy metals, and other hazardous pollutants in a variety of site environments.

  • PDF

A Study on the stress condition of apprentice doctorf who were in Oriental Medical Hospital (대구 시내 한방병원(韓方病院) 수련의의 스트레스 양상(樣相)에 관(關)한 조사(調査) 연구(硏究))

  • Woo Joo-Young;Jung Dae-Kyoo
    • Journal of Oriental Neuropsychiatry
    • /
    • v.7 no.1
    • /
    • pp.65-75
    • /
    • 1996
  • This paper is for studying stress condition of apprentice doctors who were in Oriental Medical Hospital. This study was done on 35 apprentice doctors who were in Kyungsang University Oriental Medical Hospital and Bulgy Oriental Medical Hospital. The Seven-Minute Stress Test of Thomas E. Sttats and 10 questions which were made by the present writer shows the following results.1. The Body stress scale was the highest point. In order of high percent, this shows Whole scale, Mind scale, Situation scale. 2. In comparison of the stress scale of men and women doctors, all the stress scale of women doctors were higher than men doctors. 3. In comparison of the stress scale of Interne and Resident doctors, Whole and Situation stress scale of Resident doctors were higher than Interne doctors, Body and Mind stress scale of Interne doctors were higher than Resident doctors. 4. The personal relation with other people was harmonious, the worst relation of the other colleague was the administrative staff, the next were nurses, senior apprentice doctors orderly. 5. In order of high percent of stressors, this shows personal relation, many works and troubles of care, the lack of private life, unsatisfactory administration system and equipment, the class system and overbearing atmospheres, education and continuous stress, bad conditions and fatigue, economic problems. 6. In order of high percent of systemic stress diseases, this shows musculo- skeletal disease, nervous disease, digestive disease, neurosis, urinary and genital disorder, opthalomo-otolaryngo disease, immunity disorder and vascular disease. In order of high percent of stress symptom, this show headache, fatigue, shoulder pain, back and leg pain, pantalgia and abdominal pain, diarrhea and dismenorrhea, stiffness of neck dizziness indigestion languor after a meal insomnia, neurasthenia lacking interest constipation menorrhalgia bloodshot eyes otitis media allergy thirst flushing edema. 7. In order of the seven mode of emotions in relation to stress, this shows anger, anxiety, isolation, melancholy, fright, sorrow, terror, overjoy.

  • PDF

An Assessment of Allograft Function in Canine Single Lung Transplantation (일측 폐이식 실험견에서 이식폐의 기능 평가연구)

  • 박창권
    • Journal of Chest Surgery
    • /
    • v.28 no.12
    • /
    • pp.1096-1106
    • /
    • 1995
  • We experienced 7 cases of left single lung transplantation in 14 mongrel dogs and analyzed graft lung function by hemodynamics, blood gas analysis, chest X-ray, biopsy and perfusion lung scan. We performed right pulmonary artery cuff[PA cuff for analysis of graft lung function in 3 cases. The donor lungs were flushed with modified Euro-Collins solution[n=3 or low potassium dextran glucose solution[n=4 and preserved for 4 to 5 hours[n=4 or 24 hours[n=3 at 10o C and implanted to the dogs with similar weight . Assessment of left graft lung was done by occluding the right pulmonary artery for 10 minutes using PA cuff. Assessment for graft lung function was done immediately after an operation and after 3 days, 7days and 3 weeks postoperatively. Four dogs survived for 3days, 7days[2 cases and 3 weeks respectively. Other three dogs expired within 3 hours of reperfusion. Immediate perfusion scans of left lung in four survived dogs after reperfusion were 42.1%, 36% , 11% and 5.9% respectively, and another dog with 4.8% perfusion to left lung was dead due to left atrial thrombi after 3 hours reperfusion. In one case among three acute rejections follow-up perfusion scan was done on 3rd and 11th postoperative day and the result decreased from 36% perfusion immediate postoperatively to 21% and 15% respectively. Three expired dogs postoperatively couldn`t tolerate occlusion of right pulmonary artery with above 40 mmHg of mean pulmonary artery pressure. On the other hand, three survival dogs postoperatively tolerated occlusion of right pulmonay artery with less than 30 mmHg of mean pulmonary artery pressure. and one dog couldn`t tolerate same procedure immediate postopertively but in 2 hours reperfusion later tolerated with 29 mmHg of mean pulmonary artery pressure.In conclusion we couldn`t compare the effect of two flushing solutions but low potassium dextran glucose solution showed relatively safe preservation effect in cases with preservation of more than 20 hours. Also canine left single lung transplantation model with PA cuff indicated useful method for the assessment of graft lung function with effect of lung preservation.

  • PDF

Applicability Evaluation of Electrodes Exchange and Mixed Solution for Enhanced Electrokinetic Process (Electrokinetic Process의 효율 향상을 위한 전극교환 방식과 혼합용매 적용 가능성 평가)

  • Lee, Noh-Sup;Park, Sung-Soo;NamKoong, Wan
    • Applied Chemistry for Engineering
    • /
    • v.18 no.4
    • /
    • pp.391-395
    • /
    • 2007
  • This study investigated the feasibility of enhanced electrokinetic (EK) remediation of soil contaminated with approximately 20000 Pb-mg/kg. Enhanced EK remediation was evaluated by using mixed solution (0.3 M acetic acid and 0.03 M EDTA, EK-M) and by exchanging electrodes for preventing precipitation of metal hydrate. For the EK-M, the lead removal efficiency was only 2% lower than the case where 0.03 M EDTA was solely used (EK-Blank, EK-B). Considering the costly expense of EDTA, the application of EK-M would be economically viable. The efficiency of of EK-E was higher by 2% than the EK-B method. More impertantly, the pH values of entire soil packed column presented to be neutral (7~8) in the EK-E process. Unlike to EK-B and EK-M, the deposition of heavy metals to any specific area was avoided in the EK-E process.

Analysis of Uterine Bacteria to Increase Reproductive Efficiency in Hanwoo(Korean Native Cattle) (한우의 번식 효율 향상을 위한 자궁 내 세균 분석)

  • Park, Joung-Jun;Yoo, Han-Jun;Cho, Young-Jae;Choi, Hye-Won;Yoon, Pil-Sang;Lee, Seon-Goo;Jung, Bae-Dong;Hahn, Tae-Wook
    • Journal of Embryo Transfer
    • /
    • v.28 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • The objective of this study was to evaluate several types of uterine bacteria in Hanwoo. uterine bacteria from randomly selected 5 uterus was collected by flushing methods into a sterilized 1.5 ml centrifuge tube and was inoculated onto MacConkey agar and blood agar, respectively. After being incubated for 5% $CO_2$, aerobic or anaerobic condition at $37^{\circ}C$ during 48h, bacterial colonies were selected and re-inoculated onto blood agar plates. Re-cultured colonies were identified by Gram staining and finally identified using Vitek system. The identified bacteria were Staphylococcus lentus, Staphylococcus sciuri, Staphylococcus vitulinus, Staphylococcus warneri of Gram (+) and Rhizobium radiobacter, Sphingomonas paucimobilis of Gram (-) bacteria. Although, pathogenicity of identified bacteria was unclear, the bacteria can have an effect on the uterine microenvironment. Therefore, repetitive research will be required to determine the effects of bacteria in cattle exposed to a various environment.

Hybrid Water Treatment of Tubular Ceramic MF and Photocatalyst Loaded Polyethersulfone Beads : Effect of Organic Matters, Adsorption and Photo-oxidation at Nitrogen Back-flushing (관형 세라믹 정밀여과와 광촉매 첨가 PES 구의 혼성 수처리 : 질소 역세척 시 유기물 및 흡착, 광산화의 영향)

  • Hong, Sung Taek;Park, Jin Yong
    • Membrane Journal
    • /
    • v.23 no.1
    • /
    • pp.61-69
    • /
    • 2013
  • The effect of humic acid (HA), and the roles of microfiltration (MF), PES (polyethersulfone) beads adsorption, and photo-oxidation were investigated in hybrid process of ceramic MF and PES beads loaded with titanium dioxide ($TiO_2$) photocatalyst for advanced drinking water treatment. Those were compared and studied in viewpoints of membrane fouling resistance ($R_f$), permeate flux (J), and total permeate volume ($V_T$). Because membrane fouling increased dramatically as decreasing HA, $R_f$ increased and J decreased, and finally $V_T$ was the highest at 2 mg/L HA. In the experiment to investigate the roles of photo-oxidation and adsorption at humic acid 4 mg/L and 6 mg/L. In both conditions, $R_f$ was the lowest and $V_T$ was the highest in MF + $TiO_2$ + UV process. The average treatment efficiencies of turbidity and dissolved organic matters were the highest in MF + $TiO_2$ + UV process, too.

Superovulation response after follicular wave synchronization with follicular aspiration by ultrasonography in HanWoo II. Ovarian response following superovulation treatment at different day of estrus (과배란 처치시 우세난포 조절에 의한 한우 수정란 생산성 향상에 관한 연구 II. 과배란 처치 시기에 따른 난소반응)

  • Lee, Dong-won;Lee, Byeong-chun;Hwang, Woo-suk
    • Korean Journal of Veterinary Research
    • /
    • v.40 no.4
    • /
    • pp.769-775
    • /
    • 2000
  • This study was investigated the ovarian response following superovulation treatment at different day of diestrus. The criterion for the presence or absence of a dominant follicle based on their morphological examination. Dominant follicle was puntured 48 hrs before the oneset of superovulation treatment by ultrasonography guided aspiration needle. Superovulation was induced by subcutaneous administration of FSH twice a day for 4 day in a decreasing regimen. There was no significant different between presence of dominont follicle and progesterone concentration/diameter of corpus luteum in HanWoo. Number of corpus luteum of donor after superovulation treatment was not significantly different in FSH administration at day 9, 11 and day 13 of estrus($14.5{\pm}4.5$, $15.5{\pm}5.6$ and $11.0{\pm}5.5$, respectively). But, the diameter of CL was significantly correlate(R2 = 0.757) with progesterone levels on day of superovulatory induction. After 7 days of artificial insemination, the embryos at 7 days were collected by uterine flushing after dominant follicle aspiration and superovulation treatment, and evaluated their quality by morphological criteria. Fifty five embryos with excellent, good and fair grade were transferred into 24 recipient cows. Seventeen offsprings, 1 of triplet, 4 of twins and 6 of singlet, were yield from 10 recipient cow. In conclusion, the present study showed that 1) dominant follicle can be determined by ultrasonography with rectal palpation by morphological evaluations, 2) superovulation response after follicular aspiration was not differ at day 9, 11 and 13 of estrus, 3) dominant follicle did not affect to progesterone concentration and diameter of CL, and 4) diameter of CL was significantly correlate to the level of progesterone concentrations in HanWoo.

  • PDF