Determining the simultaneous flow rate in any particular section of piping is the important step in order to determine the size of water supply piping. Now we are using the diversity curve of common water closet in order to determine the simultaneous flow rate of water supply piping, but there is a difference between a determined flow rate of general water closet and that of water closet for water saving. This study aims to find out the fixture unit of a flush valve type water closet for water saving in office building, and to determine the correlation between the fixture units and peak flow rates on the basis of the probability theory. A flush valve type water closet for water saving that have a 7.5 second duration of flush operation with an average design flow rate 72 $\ell$/fin was considered. Simulation results indicate that the number 5 is shown to be reasonable to the fixture unit of water closet for water saving. And the design can be undersized considerably with the revised diversity curves using modified fixture unit.
건물의 우수관에 연결하여 초기빗물의 부유물질을 처리할 수 있는 장치를 개발하기 위하여 건물옥상 유출 빗물의 수질특성 변화를 파악하고 다양한 여재를 활용해 초기빗물의 부유물질 제거를 연구하였다. 건물옥상 유출빗물의 입자성 물질은 대부분 $10{\sim}30{\mu}m$의 크기로, 부유물질 농도는 강우시 초기 10~20분까지 높았고 점진적으로 감소하였다. 옥상유출빗물의 용존성 유기물과 무기물의 농도도 유출 초기에 높게 나타났다. Anthracite (AC), Polyurethane (PU), Polypropylene (PP) 여재로 여과시 초기에 50%의 부유물질을 제거할 수 있었으나 20분 이상 여과시 제거율이 급격히 낮아졌다. 세척후 반복여과를 고려하면 AC 여재만 9회까지 재사용가능하였다. 여재층의 높이가 높을수록, 통과유량이 적을수록 시간에 따른 SS 제거율 감소폭은 적었고, 여재층 30 cm, 유량 12 L/min 이하로 운전할 경우 초기빗물(SS = 450 mg/L)의 SS 제거율 50%를 달성할 수 있었다.
본 연구는 국내 중소 도시지역에서 강우 시 발생하는 강우유출수의 유출경향을 분석하고 초기강우기준을 산정하기 위하여 수행되었다. 연구지역은 국가산업단지가 소속되어 있는 구미시 원평동의 주거지역으로 선정 되었으며 모니터링 기간은 3개월에 걸쳐 시행되었다. 연구지역의 유역면적은 24.9 ha이고, 토지이용형태는 주거지역으로 대상유역의 80%가 불투수 면적(포장의 형태: 아스팔트)인 것으로 나타났다. 모니터링은 총 6회의 강우사상에 대하여 실시하였으며 모든 수질항목에 대해 EMC (Event Mean Concentration)와 SMC (Site Mean Concentration)를 산정하였다. 또한 강우지속시간에 따른 입경크기분포의 변화와 초기세척 현상을 관찰하였는데, 입경크기분포는 10%입경($D_{0.1}$), 50%입경($D_{0.5}$, 90%입경($D_{0.9}$이 각각 9.82 ${\mu}m$, 38.99 ${\mu}m$, 159.61 ${\mu}m$로 나타났고, 초기세척 현상은 용존성 물질보다 입자성 물질이 더 강하게 나타났다. $MFF_n$ (Mass first flush)을 이용하여 초기강우기준을 검토한 결과 초기우수유출수의 부피 30%에 오염물질부하량의 부피 44.4~58.5%를 포함하고 있는 것으로 나타났다. $MFF_n$과 입경크기분포는 자연형, 장치형 시설과 같은 다양한 비점오염저감시설의 설계 및 운전과 초기강우기준 결정을 위한 정보를 제공할 수 있을 것으로 기대된다.
In transport networks, a multi-ring architecture is very useful to facilitate network planning and to design and provide more resilient services for customers. Unlike traditional synchronous optical network multi-rings, the service resiliency of Ethernet-based multi-rings is significantly impacted by the ring hierarchy because a link or node failure in a certain level ring triggers filtering database flush actions in all higher level rings as well as in the ring with the failure, and consequently a large amount of duplicated data frames may be flooded. In this paper, we investigate how the ring hierarchy impacts the service resiliency of multi-ring networks. Based on extensive experiments on various single- and multiple-link failures, we suggest two effective inter-ring connection rules to minimize the transient traffic and to ensure more resilient multi-ring networks. In addition, we consider a flush optimization technique called e-ADV, and show that the combination of e-ADV and multi-ring structures satisfying our inter-ring connection rules results in a more attractive survivability performance.
플래시 메모리는 현재 휴대용 기기 뿐 아니라 개인용 컴퓨터와 서버용 컴퓨터에서 널리 사용되고 있다 하드디스크를 위한 버퍼 캐시 교체 정책인 LRU(Least Recently Used)와 LFU(Least Frequently Used)는 플래시 메모리의 특성을 전혀 고려하지 않아 플래시 메모리에 적합하지 않다. 기존에 연구되었던 CFLRU(Clean-First LRU)와 그 변형인 CFLRU/C, CFLRU/E, DL-CPLRU/E는 플래시 메모리의 특성을 고려하였지만 hit ratio가 LRU와 LFU에 비하여 좋지 않다. 본 논문에서는 기존의 버퍼 캐시 교체 정책들을 보완하는 새로운 버퍼 캐시 교체 정책을 제안한다. 이 버퍼 캐시 교체 정책은 LFU를 기반으로 하고 플래시 메모리의 특성을 고려하였다. 그리고 이 새로운 버퍼 캐시 교체 정책을 기존 플래시 메모리 버퍼 캐시 교체 정책과 hit ratio와 flush 횟수를 비교하여 성능을 평가한다.
Ultra-high performance liquid chromatography (UHPLC) systems are integral to modern analytical laboratories, necessitating careful maintenance and operation protocols to ensure optimal performance. This document provides comprehensive guidelines for the proper shutdown and reactivation of UHPLC systems to prevent damage and maintain operational efficiency. • Shutdown: Remove the column and replace it with a union to avoid blockages. Flush the system with a compatible solvent mix, clean mobile phase reservoirs to prevent microbial growth, flush the pump with storage solvent, and clean the autosampler, including the needle and injection port. • Reactivation: Inspect the system for wear or damage, gradually reintroduce mobile phases starting with a weak solvent, reinstall the column securely, and perform system checks on baseline stability, pressure consistency, and detector performance. By adhering to these guidelines, laboratories can ensure the longevity and reliability of their UHPLC systems, maintaining high analytical performance and minimizing downtime. These procedures help prevent common issues such as blockages, contamination, and component wear, thereby supporting efficient and accurate analytical operations.
스프링클러 설비는 화재 발생 시 화재를 초기에 제어 및 진압하는 설비로서 어떠한 화재 분위기에서도 스프링클러 헤드의 작동온도에서 정상적인 동작을 하여야 한다. 그러나 최근 화재성장속도가 느린 화재 발생 장소에서 일부 조기반응형 스프링클러 헤드가 정상적인 동작을 하지 않을 수 있다는 문제가 제기되고 있다. 이에 본 논문에서는 공동주택 침실규모의 모형실험 및 캐비넷형 버너를 이용하여 화재성장속도가 느린 조건을 형성하고 실제 현장에서 배관 내에 가해지는 최소압력인 0.2MPa 이상의 가압수를 공급하여 실험을 진행하였다. 실험결과 국내에서 사용되고 있는 과반수 이상의 플러쉬형 조기반응형 스프링클러 헤드에서 Cold Soldering 현상이 발생되면서 불완전하게 개방되는 것이 확인되었다. 이러한 현상은 화재 조기진압 및 제어에 실패하여 화재확산 및 인명피해의 원인이 될 수 있으므로 추가적인 연구를 통해 국내 형식승인 및 제품검사기준의 보완의 필요할 것으로 판단된다.
Management of Swimming pool is focused on Swimming pool samitation in relation with chlorination of swimming water and potable water, disposal of waste and excrement within the boundry of swimming pool that may be summerised as follows: 1. Chlorination of Swimming Water Residual chlorine must be kept within the range of $0.4\~0.6 mg/l$ and in case of chloramine should be $0.7\~1.0mg/l$ while swimming pool is in operation 2. Chlorination of potable Water Residual chlorine must be kept within the rangs of $0.2\~04 mg/l$ at all time 3. Disposal of litters must be kept in the water tight waste bin with fitted lid, and waste should not be overflow -out of the bin. When waste in landfilled, the sufficient amount of cover material should be used daily. 4. Disposal of excrement Toilet must be water-flush type. However, The establishment of pit latrine is unavoidable the excrement must be covered with lime or dirt so that excrement should not be exposed to air.
목적 : Tibial Inlay 방법을 이용한 후방 십자 인대 재건술의 임상적, 방사선학적 결과를 알아보고자 하였다. 대상 및 방법 : 1996년 2월부터 후방 십자 인대 부전증으로 tibial inlay 방법으로 후방 십자 인대 재건술을 시행하고 2년 이상 추시가 가능했던 24명, 25예를 대상으로 Lysholm knee score 및 후방전위 검사, 층형성(step off sign) 등의 임상적 결과와 $Telos^{\circledR}$ 기구(Telos stress device; Austin & Associates, Inc., Polston, US)를 이용한 슬관절 후방 전위 방사선 사진을 촬영하여 건측과 비교하여 안정성 여부를 측정하였다. 수술시 평균나이는 35세였고 평균 추시는 34개월($24\~53$개월)이었다. 결과 : Lysholm knee score는 술전 평균 56.9점에서 최종 추시상 94.6점으로 호전되었고 후방전위검사는 술전 Grade II 1예, Grade III 18예, Grade IV 6예였던 것이 술후 Grade I 12예, Grade II 10예, Grade III 3예로 회복되었다. step off sign도 술전 -10mm 6예, -5mm 18예, flush 1예였던 것이 술후 -5mm 3예, flush 10예, +5mm 12예로 호전되었다. $Telos^{\circledR}$ 기구를 이용한 후방 전위 방사선 사진상 반대측과 비교하여 술전 평균 13.6$(9\~31)$mm의 차이를 보였으나 추시상 평균 4.3$(1\~10)$mm로 호전되었다. 결론 : Tibial Inlay 방법을 이용한 후방 십자 인대 재건술은 경골 부착부에 직접 이식건을 견고하게 고정할 수 있어 이식건의 마모가 없고 비교적 큰 이식건을 사용할 수 있는 장점이 있고, 2년 이상의 추시상 임상적 및 방사선학적으로 좋은 결과를 보여 후방 십자 인대 재건술의 좋은 술식으로 생각된다.
The purpose of this study was to analyse the runoff characteristics of non-point pollution sources in an urban watershed and determine the effectiveness of newly installed riverwater treatment system to reduce water pollution caused by storm runoff in the urban watershed. The results of this study showed that the levels of BOD5 and suspended solid were highly influenced by first-flush effect and the pollutant load of those two parameters were also very high in the urban watershed. Meanwhile, the effectiveness of riverwater treatment system to reduce the levels of BOD5 and suspended solid was relatively high, but those to reduce the levels of T-N and T-P was low, which needs some additional unit treatment process such as filtration and coagulation. Nonetheless, the riverwater treatment system tested was relatively simple in installation and operation, effective in removing many water pollutants and, most importantly, does not require much space as other treatment systems, so it could be an attractive alternative option to reduce riverwater pollution caused by storm runoff in urban watersheds.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.