• Title/Summary/Keyword: flush operation

검색결과 14건 처리시간 0.022초

사무소 건물의 급수배관경 산정을 위한 동시사용유량에 관한 연구 (The evaluation of the simultaneous flow rate for sizing the water supply piping in the office building)

  • 이용화
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.511-517
    • /
    • 1999
  • Determining the simultaneous flow rate in any particular section of piping is the important step in order to determine the size of water supply piping. Now we are using the diversity curve of common water closet in order to determine the simultaneous flow rate of water supply piping, but there is a difference between a determined flow rate of general water closet and that of water closet for water saving. This study aims to find out the fixture unit of a flush valve type water closet for water saving in office building, and to determine the correlation between the fixture units and peak flow rates on the basis of the probability theory. A flush valve type water closet for water saving that have a 7.5 second duration of flush operation with an average design flow rate 72 $\ell$/fin was considered. Simulation results indicate that the number 5 is shown to be reasonable to the fixture unit of water closet for water saving. And the design can be undersized considerably with the revised diversity curves using modified fixture unit.

  • PDF

여과재를 활용한 건물옥상유출 초기빗물의 부유물질 저감 (Reduction of Suspended Solids in First Flush from a Building Rooftop using Various Media)

  • 김성범;이원태
    • 대한환경공학회지
    • /
    • 제39권4호
    • /
    • pp.214-219
    • /
    • 2017
  • 건물의 우수관에 연결하여 초기빗물의 부유물질을 처리할 수 있는 장치를 개발하기 위하여 건물옥상 유출 빗물의 수질특성 변화를 파악하고 다양한 여재를 활용해 초기빗물의 부유물질 제거를 연구하였다. 건물옥상 유출빗물의 입자성 물질은 대부분 $10{\sim}30{\mu}m$의 크기로, 부유물질 농도는 강우시 초기 10~20분까지 높았고 점진적으로 감소하였다. 옥상유출빗물의 용존성 유기물과 무기물의 농도도 유출 초기에 높게 나타났다. Anthracite (AC), Polyurethane (PU), Polypropylene (PP) 여재로 여과시 초기에 50%의 부유물질을 제거할 수 있었으나 20분 이상 여과시 제거율이 급격히 낮아졌다. 세척후 반복여과를 고려하면 AC 여재만 9회까지 재사용가능하였다. 여재층의 높이가 높을수록, 통과유량이 적을수록 시간에 따른 SS 제거율 감소폭은 적었고, 여재층 30 cm, 유량 12 L/min 이하로 운전할 경우 초기빗물(SS = 450 mg/L)의 SS 제거율 50%를 달성할 수 있었다.

국내 중소 도시지역 강우유출수의 유출특성 (Runoff Characteristics of Stormwater in Small City Urban Area)

  • 이홍신;이승환
    • 대한환경공학회지
    • /
    • 제31권3호
    • /
    • pp.193-202
    • /
    • 2009
  • 본 연구는 국내 중소 도시지역에서 강우 시 발생하는 강우유출수의 유출경향을 분석하고 초기강우기준을 산정하기 위하여 수행되었다. 연구지역은 국가산업단지가 소속되어 있는 구미시 원평동의 주거지역으로 선정 되었으며 모니터링 기간은 3개월에 걸쳐 시행되었다. 연구지역의 유역면적은 24.9 ha이고, 토지이용형태는 주거지역으로 대상유역의 80%가 불투수 면적(포장의 형태: 아스팔트)인 것으로 나타났다. 모니터링은 총 6회의 강우사상에 대하여 실시하였으며 모든 수질항목에 대해 EMC (Event Mean Concentration)와 SMC (Site Mean Concentration)를 산정하였다. 또한 강우지속시간에 따른 입경크기분포의 변화와 초기세척 현상을 관찰하였는데, 입경크기분포는 10%입경($D_{0.1}$), 50%입경($D_{0.5}$, 90%입경($D_{0.9}$이 각각 9.82 ${\mu}m$, 38.99 ${\mu}m$, 159.61 ${\mu}m$로 나타났고, 초기세척 현상은 용존성 물질보다 입자성 물질이 더 강하게 나타났다. $MFF_n$ (Mass first flush)을 이용하여 초기강우기준을 검토한 결과 초기우수유출수의 부피 30%에 오염물질부하량의 부피 44.4~58.5%를 포함하고 있는 것으로 나타났다. $MFF_n$과 입경크기분포는 자연형, 장치형 시설과 같은 다양한 비점오염저감시설의 설계 및 운전과 초기강우기준 결정을 위한 정보를 제공할 수 있을 것으로 기대된다.

Impacts of Hierarchy in Ethernet Ring Networks on Service Resiliency

  • Lee, Kwang-Koog;Ryoo, Jeong-Dong;Kim, Young-Lok
    • ETRI Journal
    • /
    • 제34권2호
    • /
    • pp.199-209
    • /
    • 2012
  • In transport networks, a multi-ring architecture is very useful to facilitate network planning and to design and provide more resilient services for customers. Unlike traditional synchronous optical network multi-rings, the service resiliency of Ethernet-based multi-rings is significantly impacted by the ring hierarchy because a link or node failure in a certain level ring triggers filtering database flush actions in all higher level rings as well as in the ring with the failure, and consequently a large amount of duplicated data frames may be flooded. In this paper, we investigate how the ring hierarchy impacts the service resiliency of multi-ring networks. Based on extensive experiments on various single- and multiple-link failures, we suggest two effective inter-ring connection rules to minimize the transient traffic and to ensure more resilient multi-ring networks. In addition, we consider a flush optimization technique called e-ADV, and show that the combination of e-ADV and multi-ring structures satisfying our inter-ring connection rules results in a more attractive survivability performance.

MLC-LFU : 플래시 메모리를 위한 멀티레벨 버퍼 캐시 관리 정책 (MLC-LFU : The Multi-Level Buffer Cache Management Policy for Flash Memory)

  • 옥동석;이태훈;정기동
    • 한국정보과학회논문지:컴퓨팅의 실제 및 레터
    • /
    • 제15권1호
    • /
    • pp.14-20
    • /
    • 2009
  • 플래시 메모리는 현재 휴대용 기기 뿐 아니라 개인용 컴퓨터와 서버용 컴퓨터에서 널리 사용되고 있다 하드디스크를 위한 버퍼 캐시 교체 정책인 LRU(Least Recently Used)와 LFU(Least Frequently Used)는 플래시 메모리의 특성을 전혀 고려하지 않아 플래시 메모리에 적합하지 않다. 기존에 연구되었던 CFLRU(Clean-First LRU)와 그 변형인 CFLRU/C, CFLRU/E, DL-CPLRU/E는 플래시 메모리의 특성을 고려하였지만 hit ratio가 LRU와 LFU에 비하여 좋지 않다. 본 논문에서는 기존의 버퍼 캐시 교체 정책들을 보완하는 새로운 버퍼 캐시 교체 정책을 제안한다. 이 버퍼 캐시 교체 정책은 LFU를 기반으로 하고 플래시 메모리의 특성을 고려하였다. 그리고 이 새로운 버퍼 캐시 교체 정책을 기존 플래시 메모리 버퍼 캐시 교체 정책과 hit ratio와 flush 횟수를 비교하여 성능을 평가한다.

UHPLC 시스템 종료 및 재가동 시 가이드 (UHPLC System Shutdown and Reactivation Advice)

  • Mark Fever;Gemma Lo
    • FOCUS: LIFE SCIENCE
    • /
    • 제1호
    • /
    • pp.8.1-8.3
    • /
    • 2024
  • Ultra-high performance liquid chromatography (UHPLC) systems are integral to modern analytical laboratories, necessitating careful maintenance and operation protocols to ensure optimal performance. This document provides comprehensive guidelines for the proper shutdown and reactivation of UHPLC systems to prevent damage and maintain operational efficiency. • Shutdown: Remove the column and replace it with a union to avoid blockages. Flush the system with a compatible solvent mix, clean mobile phase reservoirs to prevent microbial growth, flush the pump with storage solvent, and clean the autosampler, including the needle and injection port. • Reactivation: Inspect the system for wear or damage, gradually reintroduce mobile phases starting with a weak solvent, reinstall the column securely, and perform system checks on baseline stability, pressure consistency, and detector performance. By adhering to these guidelines, laboratories can ensure the longevity and reliability of their UHPLC systems, maintaining high analytical performance and minimizing downtime. These procedures help prevent common issues such as blockages, contamination, and component wear, thereby supporting efficient and accurate analytical operations.

  • PDF

저성장속도 화재에서의 스프링클러 헤드 동작특성에 관한 실험적 연구 (An Experimental Study on Characteristics of Sprinkler Head Activation in Low Growth Rate Fire)

  • 최용섭;윤종칠
    • 한국화재소방학회논문지
    • /
    • 제30권5호
    • /
    • pp.26-35
    • /
    • 2016
  • 스프링클러 설비는 화재 발생 시 화재를 초기에 제어 및 진압하는 설비로서 어떠한 화재 분위기에서도 스프링클러 헤드의 작동온도에서 정상적인 동작을 하여야 한다. 그러나 최근 화재성장속도가 느린 화재 발생 장소에서 일부 조기반응형 스프링클러 헤드가 정상적인 동작을 하지 않을 수 있다는 문제가 제기되고 있다. 이에 본 논문에서는 공동주택 침실규모의 모형실험 및 캐비넷형 버너를 이용하여 화재성장속도가 느린 조건을 형성하고 실제 현장에서 배관 내에 가해지는 최소압력인 0.2MPa 이상의 가압수를 공급하여 실험을 진행하였다. 실험결과 국내에서 사용되고 있는 과반수 이상의 플러쉬형 조기반응형 스프링클러 헤드에서 Cold Soldering 현상이 발생되면서 불완전하게 개방되는 것이 확인되었다. 이러한 현상은 화재 조기진압 및 제어에 실패하여 화재확산 및 인명피해의 원인이 될 수 있으므로 추가적인 연구를 통해 국내 형식승인 및 제품검사기준의 보완의 필요할 것으로 판단된다.

수영장 관리 (Management of Swimming Pool)

  • 김경호
    • 환경위생공학
    • /
    • 제4권1호
    • /
    • pp.37-42
    • /
    • 1989
  • Management of Swimming pool is focused on Swimming pool samitation in relation with chlorination of swimming water and potable water, disposal of waste and excrement within the boundry of swimming pool that may be summerised as follows: 1. Chlorination of Swimming Water Residual chlorine must be kept within the range of $0.4\~0.6 mg/l$ and in case of chloramine should be $0.7\~1.0mg/l$ while swimming pool is in operation 2. Chlorination of potable Water Residual chlorine must be kept within the rangs of $0.2\~04 mg/l$ at all time 3. Disposal of litters must be kept in the water tight waste bin with fitted lid, and waste should not be overflow -out of the bin. When waste in landfilled, the sufficient amount of cover material should be used daily. 4. Disposal of excrement Toilet must be water-flush type. However, The establishment of pit latrine is unavoidable the excrement must be covered with lime or dirt so that excrement should not be exposed to air.

  • PDF

Tibial Inlay 방법을 이용한 후방 십자 인대 재건술의 결과 (Posterior Cruciate Ligament Reconstruction by Tibial Inlay Technique)

  • 송은규;윤택림;정종욱;김종선
    • 대한관절경학회지
    • /
    • 제5권2호
    • /
    • pp.80-84
    • /
    • 2001
  • 목적 : Tibial Inlay 방법을 이용한 후방 십자 인대 재건술의 임상적, 방사선학적 결과를 알아보고자 하였다. 대상 및 방법 : 1996년 2월부터 후방 십자 인대 부전증으로 tibial inlay 방법으로 후방 십자 인대 재건술을 시행하고 2년 이상 추시가 가능했던 24명, 25예를 대상으로 Lysholm knee score 및 후방전위 검사, 층형성(step off sign) 등의 임상적 결과와 $Telos^{\circledR}$ 기구(Telos stress device; Austin & Associates, Inc., Polston, US)를 이용한 슬관절 후방 전위 방사선 사진을 촬영하여 건측과 비교하여 안정성 여부를 측정하였다. 수술시 평균나이는 35세였고 평균 추시는 34개월($24\~53$개월)이었다. 결과 : Lysholm knee score는 술전 평균 56.9점에서 최종 추시상 94.6점으로 호전되었고 후방전위검사는 술전 Grade II 1예, Grade III 18예, Grade IV 6예였던 것이 술후 Grade I 12예, Grade II 10예, Grade III 3예로 회복되었다. step off sign도 술전 -10mm 6예, -5mm 18예, flush 1예였던 것이 술후 -5mm 3예, flush 10예, +5mm 12예로 호전되었다. $Telos^{\circledR}$ 기구를 이용한 후방 전위 방사선 사진상 반대측과 비교하여 술전 평균 13.6$(9\~31)$mm의 차이를 보였으나 추시상 평균 4.3$(1\~10)$mm로 호전되었다. 결론 : Tibial Inlay 방법을 이용한 후방 십자 인대 재건술은 경골 부착부에 직접 이식건을 견고하게 고정할 수 있어 이식건의 마모가 없고 비교적 큰 이식건을 사용할 수 있는 장점이 있고, 2년 이상의 추시상 임상적 및 방사선학적으로 좋은 결과를 보여 후방 십자 인대 재건술의 좋은 술식으로 생각된다.

  • PDF

도시지역의 비점오염유출특성을 고려한 도시하천 적정관리방안 (Selection of Best Management Practices for Urban Watershed Corresponding to the Runoff Characteristics from Non-point Pollution Sources)

  • 지홍진;신귀암
    • 한국환경과학회지
    • /
    • 제25권1호
    • /
    • pp.31-40
    • /
    • 2016
  • The purpose of this study was to analyse the runoff characteristics of non-point pollution sources in an urban watershed and determine the effectiveness of newly installed riverwater treatment system to reduce water pollution caused by storm runoff in the urban watershed. The results of this study showed that the levels of BOD5 and suspended solid were highly influenced by first-flush effect and the pollutant load of those two parameters were also very high in the urban watershed. Meanwhile, the effectiveness of riverwater treatment system to reduce the levels of BOD5 and suspended solid was relatively high, but those to reduce the levels of T-N and T-P was low, which needs some additional unit treatment process such as filtration and coagulation. Nonetheless, the riverwater treatment system tested was relatively simple in installation and operation, effective in removing many water pollutants and, most importantly, does not require much space as other treatment systems, so it could be an attractive alternative option to reduce riverwater pollution caused by storm runoff in urban watersheds.