• Title/Summary/Keyword: fluoride wastewater

Search Result 58, Processing Time 0.041 seconds

Fluoride Wastewater Treatment using Waste Concrete Powder (폐콘크리트분말을 이용한 불산폐수 처리)

  • Kim, Eun-I;Kang, Wan-Hyup;Park, Joo-Yang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.2
    • /
    • pp.125-134
    • /
    • 2005
  • Waste concrete powder was used to remove fluoride ions in highly concentrated fluoride wastewater. 92.6% of fluoride in 100 mg F/L wastewater was removed by 1% dose of the cement paste powder that represents characteristics of waste concrete powder, whereas the removal efficiencies of raw cement and lime were 47.3% and 96.4%, respectively. The cement paste powder was competitive to lime, common fluoride removal agent. Various Ca-bearing hydrates such as portlandite, calcium silicate hydrate, and ettringite in cement paste slurry can remove fluoride by precipitating $CaF_2$ and absorbing $F^-$ ions. In the experiments using both cement paste and lime, 50~67% of lime can be substituted by cement paste to satisfy fluoride effluent limitation of 15 mg/L. Since cement paste has higher acid neutralization capacity than lime, it can be recycled to neutralize more acid and to remove more fluoride. Therefore waste concrete powder can be more economical and viable alternative for lime in fluoride wastewater treatment.

Effects on Microbial Activity and Substrate Removal in Industrial Wastewater with Fluoride Content (산업폐수에서 불소함유가 미생물활성도 및 기질제거에 미치는 영향에 관한 연구)

  • Choi, Jung Su;Joo, Hyun Jong;Jin, Oh Suk
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.5
    • /
    • pp.717-722
    • /
    • 2012
  • Fluoride can be easily found in semiconductor and display industry. However, there is a lack of research for its effects on the related wastewater treatment. The objective of this study is to evaluate the microbial inhibitory effect by fluoride injection. The research entailed the assessment of removal efficiency of $TCOD_{Cr}$ according to the fluoride concentration and also the Specific Oxygen Uptake Rate (SOUR) was measured. The laboratory scale reactor was prepared and operated with the fluoride concentrations of 0, 10, 50, 100, and 200 mg/L based on concentrations frequently occurring in the wastewater. The results from this study showed that, as the fluoride concentration increase, the Specific Substrate Utilization Rate (SSUR) tend to decrease as expected. Also, the increase in fluoride concentrations resulted in the decrease in SOUR. It is determined that fluoride injection affects the microbial activity. Especially, The addition of above 200 mg/L fluoride into reactor caused rapidly decreased SSUR and SOUR due to the inhibitory effects of fluoride.

Optimum Condition for Fluoride Removal Prior to the Application of Struvite Crystallization in Treating Semiconductor Wastewater (Struvite 결정화를 이용한 반도체 폐수처리 시 불소제거를 위한 최적 조건)

  • An, Myeong Ki;Woo, Gwi Nam;Kim, Jin Hyung;Kang, Min Koo;Ryu, Hong Duck;Lee, Sang-Ill
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.916-921
    • /
    • 2009
  • This study was aimed to both enhance the fluoride removal and to reduce the phosphorus removal in treating semiconductor wastewater using $Ca(OH)_2$ at low pH so as to facilitate struvite crystallization reaction. The struvite crystallization could be introduced after fluoride removal by retaining the phosphorus source. As the results, the method applied in this study achieved high fluoride removal efficiency (about 91%) with retardation of phosphorus removal at pH 4, compared to conventional methods where the removal of fluoride and phosphorus were done at pH 11. Therefore, the fluoride removal at low pH would contribute to the enhancement of nitrogen and phosphorus removals in a consecutive struvite crystallization reactor. Treatment of semiconductor wastewater at low pH using $Ca(OH)_2$ also had lower (about 20%) water content of precipitated sludge compared to conventional method. As the molar ratio of Ca to F increased the removal efficiencies of fluoride and phosphorus increased. Although the amount of seed dosage didn't affect the removal of fluoride and phosphorus, its increase reduced the water content of precipitated matter. Finally, considering consecutive struvite reaction, the optimum condition for the removal of fluoride and phosphorus was as follow: pH: 4, the molar ratio of Ca:F: 1:1.

A Study of Fluoride Injection in Water Supply (상수도수 불소투입에 관한 연구)

  • Kim, Sung-Soon;Lee, Yang-Kyoo;Kim, Gab-Jin;Seo, Seong-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.4
    • /
    • pp.73-84
    • /
    • 1996
  • Fluoride was first introduced into the drinking water of residents of Grand Rapids, Michigan in 1945 for the prevention of dental caries. Ever since, growing numbers of communities favor fluoridation. Now, over 7000 communities in the United States are adding F(0.7~1.2ppm) to their drinking water. The most effective to prevent tooth decay is putting lower concentrated fluoride(F, 0.7~1.2ppm) into drinking water. However, exact fluoride injection amount have not been decided, because the research of the fluoride injection effect was insufficient. Therefore, after separating fluoridation and non-fluoridation into public water supplies, we investigated concentration of fluoride, alkalinity, Al, Ca, Mg, evaporation residuals in APT, domestic, commercial area. Then, we decided allowable concentration of fluoride, injection point of fluoride in water supply system, cost effectiveness.

  • PDF

Removal of Hydrogen Fluoride from Waterjet Plasma Wastewater by Electrocoagulation (전해응집법에 의한 불화수소 함유 워터젯 플라즈마 폐수처리)

  • Lee, Chae Hong;Chun, Young Nam
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.10
    • /
    • pp.702-708
    • /
    • 2012
  • Tetrafluoromethane ($CF_4$) has been used as etching and Chemical Vapor Deposition (CVD) gases for semiconductor manufacturing processes. These gases need to be removed efficiently because of their strong absorption of infrared radiation and long atmospheric lifetimes which cause the global warming effect. Also, the wastewater including the fluorine is caused by of the ground water pollution. Long-term consumption of water containing excessive fluoride can lead to fluorosis of the teeth and bones. The wastewater including the fluorine among the by-product which is generated by using the waterjet plasma after destroying $CF_4$ by HF is generated. The system which can remove the hydrogen fluoride among the wastewater by using the electrocoagulation using this wastewater the aluminum electrode was developed. The operating condition such as initial pH, electrocoagulation time, wastewater flow rate, current density were investigated experimentally using a electrocoagulation. Through the parametric studies, the highest hydrogen fluoride destruction of 85% was achieved at 3.5 initial pH, 10 min electrocoagulation time, 10 mL/min wastewater flow rate and $159A/m^2$ current density.

Studies on the Adsarption Characteristics of Fluoride Ion-Containing Wastewater by Employing Waste Oyster Shell as an Adsorbent (폐굴껍질을 흡착제로 한 불소폐수 처리특성에 관한 연구)

  • Lee, Jin-Suk;Kim, Dong-Su
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.2
    • /
    • pp.222-227
    • /
    • 2007
  • The adsorption features of fluoride ion on the oyster shell have been investigated for the purpose of the employment of waste oyster shell as an adsorbent for the treatment of fluoride ion-containing wastewater. The major component of oyster shell was examined to be Ca with minor components of Na, Si, Mg, Al, and Fe. As the initial concentration of fluoride ion was raised, its absorbed amount was enhanced at equilibrium, however, the adsorption ratio of fluoride ion compared with its initial concentration was shown to be decreased. Also, adsorption of fluoride ion onto the oyster shell resulted in the formation of $CaF_2$ in the morphological structure of adsorbent. Kinetic analysis showed that the adsorption reaction of fluoride ion generally followed a second order reaction with decreasing rate constant with the initial concentration of adsorbate. Freundlich model agreed well with the adsorption behavior of fluoride ion at equilibrium and the adsorption reaction of fluoride ion was examined to be endothermic. Several thermodynamic parameters for the adsorption reaction were calculated based on thermodynamic equations and the activation energy for the adsorption of fluoride ion onto oyster shell was estimated to be ca. 13.589 kJ/mole.

Estimate Analysis on the Fluoride Work Management of Water Supply Conveyance (상수도수 불화사업 운영에 관한 평가분석)

  • Kim, Kap-Jin;Lee, Yang-Kyoo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.17 no.4
    • /
    • pp.510-518
    • /
    • 2003
  • The fluoride work management of water supply conveyance has been recommending by the WHO to prevent of tooth decay. Fluoridation of public water supplies has been practiced since 1945. The present approximately 67 countries reported community water fluoridation benefiting many cities. At our country, Fluoridation began in 1981 in Chongiu and Jinhea. In 2002, approximately 40 cities have large populations consuming fluoridated water. But Chongiu stopped fluoridation water works. Few public health measures have been accorded greater clinical and laboratory research, epidemiological study, clinical trials, and public attention than has water fluoridation. In this study, chemical analysis of Sodium Silicofluoride and Fluoride Feed Equipment analyzed. And this study proposed to Fluoride concentration experimental (lab. and field exp.), economics analysis, prevention effect. This study can be decided on the concentration of fluoride injection in Water Fluoridation. Hereafter, this study will be useful in safety and economics of Water Fluoridation in the future.

Defluoridation of Wastewater by Adsorption on Bituminous Coal Fly Ash (유연탄 소각 비산재를 이용한 폐수중의 불소이온 제거)

  • 이성대;박석환;정문식
    • Journal of Environmental Health Sciences
    • /
    • v.19 no.1
    • /
    • pp.51-56
    • /
    • 1993
  • This study was performed to find the ability of bituminous coal fly ash to remove fluoride from water and wastewater at different fluoride concentration, reaction temperature, reaction time and pH. The removal of fluoride is favorable at low concentration, high temperature and acidic pH. With the increase in the initial fluoride concentration, the amount adsorbed increased. Adsorption process was exothermic at pH 2.0. Physisorption process was predominant over pH 2.3, while Chemisorption was under pH 2.3. Fluoride uptake by fly ash was conducted the adherence of fluoride on the active surface sites of adsorbent and its intraparticle diffusion within adsorbent. The values of rate constants of adsorption were 3.028X 10$^{-3}$, 4.715X 10$^{-3}$, 2.88X 10$^{-3}$ (min) and intraparticle diffusion were 1.434X10$^{-3}$, 3.012X10$^{-3}$, 5.635X10$^{-3}$ at each temperatures.

  • PDF

Treatment of Mixed Fluoride Wastewater Using Cement Paste (시멘트 페이스트를 이용한 혼합 불산폐수 처리)

  • Byun, Hye-Jung;Choi, Won-Ho;Park, Joo-Yang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.8
    • /
    • pp.909-914
    • /
    • 2007
  • Fluorine compounds are the essential chemicals for wet processes of semiconductor and LCD production line. Problems of conventional treatments for fluoride wastewater are their high operation costs and low fluoride removal capacity. In this study, cement paste containing various Ca-bearing hydrates such as portlandite, calcium silicate hydrate(CSH), and ettringite was investigated for fluoride removal. The objectives of this study are to assess the feasibility of using cement paste cured mixture of cement and water as an alternative agent for treatment of fluoride wastewater and to investigate fluoride removal capacity of the cement paste. The performance of cement paste was comparable to that of lime in the kinetic test. In column experiment where the effluent fluoride concentrations were below 0.5 mg/L. Then the leached calcium reached the maximum level of 800 mg/L. The nitrate reduced to the level of less than 10 mg/L. Nitrate in the wastewater was exchanged with interlayer sulfate of these cement hydrate LDHs. Phosphate concentration could be reduced to 10 mg/L by forming calcium phosphate. These results indicate that the cement paste generally has advantageous characteristics as an economical and viable substitute for lime to remove fluoride.

Effects of pyrolysis temperature of the waste cattle bone char on the fluoride adsorption characteristics (소뼈의 소성 온도가 골탄의 불소흡착 특성에 미치는 영향)

  • Kim, Junyoung;Hwang, Jiyeon;Choi, Younggyun;Shin, Gwyam
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • In this study, the physicochemical characteristics and fluoride adsorption capacity of the bone char pyrolyzed at different temperatures; 200℃, 300℃, 350℃, 400℃, 500℃, 600℃, and 700℃ were investigated. Analytical studies of the synthesized bone char including; SEM-EDS, XRD, BET and FT-IR, showed the presence of hydroxyapatite(HAP), which is the main substance that adsorbs fluoride from aqueous solutions containing high fluoride concentrations. Bone char pyrolyzed from 350~700℃ specifically revealed that, the lower the temperature, the higher the fluoride adsorption capacity and vice versa. The loss of the fluoride adsorption function of HAP (OH- band in the FTIR analysis) was interpreted as the main reason behind this inverse correlation between temperature and fluoride adsorption. Bone char produced at 350℃ hence exhibited a fluoride adsorption capacity of 10.56 mgF/g, resulting in significantly higher adsorption compared to previous studies.