• Title/Summary/Keyword: fluorescence polarizaiton

Search Result 2, Processing Time 0.021 seconds

Effect of Lipid Peroxidation on the Fluidity of Erythrocyte Ghost and Phospholipid Liposomal Membranes

  • Han, Suk-Kyu;Kim, Min;Park, Yeong-Hun;Park, Eun-Ju;Lee, Jeong-Hee
    • Archives of Pharmacal Research
    • /
    • v.15 no.4
    • /
    • pp.309-316
    • /
    • 1992
  • The effects of lipid peroxidation on the fluidity of the lipid bilayers of the human erythrocyte ghosts and egg-lecithin phospholipid liposomes have been studied. For the measurements of the peroxidation extent and the fluidity of the membranes, the thiobarbituric acid-reactive substances and the fluorescence depolarization of 1, 6-diphynyl-1, 3, 5-hexatriene labelled into the membrane were employed, respectively. The lipid peroxidation was performed in hypoxanthine/xanthine oxidase/ferrous ion, and hydrogen peroxide/ferrous ion systems. The results of these experiments show that both of the xanthine oxidase and hydrogen peroxide systems effectively. The lipid peroxidation decreased the fluidity of the membranes, especially at the very early stage of the peroxidation reaction. The decrease in the fluidity of membrane by the lipid peroxidation has been ascribed to the alteration of the polyunsaturated acyl chains of lipids and cross linkages among the membrane components. However, under drastic condition of lipid peroxidation, tdhe fluidity of the membrane rather increased possibly due to the deterioration of the membrane integrity by the peroxidation. Morphological change of the erythrocyte on peroxidation has also been observed.

  • PDF

A Simple Device of the Dry Tetrabromophenolphthalein Ethyl Ester Reagent Strip for the Detection of Methamphetamine

  • Choi, Myung-Ja;Song, Eun-Young;Kim, Seung-Ki;Choi, Jeong-Eun;Lho, Dong-Seok;Park, Jong-Sei
    • Archives of Pharmacal Research
    • /
    • v.16 no.3
    • /
    • pp.227-230
    • /
    • 1993
  • A new device to detect methamphetamine (MA), amphetamine(A) and its metabolites in urine was developed using the paper strip method and the test tube method of dry chemical reagents. The reagent containing tetrabromophenolphthalein ethyl ester (TBPE) and borax. For the TBPE paper strip method, a device was prepared with a window at each end of the reagent paper strip ; one window is for the sample application, and the other window is for the methylene chloride. The diffused sample from one window reacts with reagent in the paper and produces color at the point where it meets with methylene chloride which has diffused form the other side. A positive smaple produces as red-purple color and the negative sample a greenish color, with a detection limit of 5-10 ppm. The result can be obtained within one minute. For the TBPE test tube method which contains dry reagents, the detection limit is 5 ppm and the result can be obtaineed within 30 seconds, however the carry-on is not as convenient as the paper strip method. The performance of both methods were evlauated by comparing with the results of gas chromatography (GC) and fluorescence polarizaiton immunoassay (FPIA). The results were proven that both methods were useful as primary screening reagents to detect MA in urine and in dry powder.

  • PDF