• 제목/요약/키워드: flowing velocity

검색결과 220건 처리시간 0.034초

회전 원판 위 액막 유동 찢김 가시화 (Visualization of rupturing of rotating films)

  • 김동주;김대겸
    • 한국가시화정보학회지
    • /
    • 제22권1호
    • /
    • pp.28-33
    • /
    • 2024
  • We visualized the rupturing of liquid films flowing over a disk rotating with large angular velocity. A setup of high speed imaging for liquid flows on dark and reflective surfaces are suggested. From the result, rivulet structures are revealed to be strongly governed by three-dimensional surface structures developed in the film flow. Additionally, unique flow structures including the rivulet sliding and internal meandering are investigated. Generation mechanism of such structures are discussed in terms of the dynamic contact angle theory.

가열원관군 주위를 유동하는 굴패각의 탈착과정에 대한 열 및 물질전달에 관한 연구 (Study on the Heat and Mass Transfer Characteristics of Oyster Shell Flowing through the Bundle of Heating Pipes)

  • 김명준
    • 동력기계공학회지
    • /
    • 제17권3호
    • /
    • pp.28-34
    • /
    • 2013
  • This study is experimentally performed for using the oyster shell as a desiccant in the fluidized bed with bundle of heating pipe. The test material is oyster shell from fishery wastes which can use without costs. The main parameters of experiment are inlet air temperature, velocity of inlet air and heat flux of heating pipes. Also the geometry of heating pipe is treated as important parameter. From this study, the effect of inlet air temperature and input heat flux have much affect to increase the heat and mass transfer. On the other hand, the effect of inlet air velocity has less affect to increase the heat and mass transfer. And it is clarified that the oyster shell has sufficient probability for using as a desiccant in air-conditioning system.

초유동 충격파관 장치의 고레이놀즈수 유동실험에의 응용 (Application of Superfluid Shock Tube Facility to experiment of High Reynolds number flow)

  • 양형석
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.27-30
    • /
    • 2002
  • The particle velocity in superfluid helium (He II) induced by a gas dynamic shock wave impingement onto He II free surface were studied experimentally by using Schlieren visualization method with an ultra-high speed video camera. It is found form visualization results that a dark zone in the immediate vicinity of the vapor-He II interface region is formed because of the high compressibility of He II and is developed toward bulk He II with the flowing-down speed of the vapor-He II interface. The mass velocity behind a transmitted compression shock wave that is equal to the contraction speed of He II amounts to 10 m/sec, the Reynolds number of which reaches $10^{7}$. This fact suggests that the superfluid shock tube facility can be applied to an experimental facility for high Reynols number flow as an alternative to the superfluid wind tunnel.

  • PDF

평형평판 간극사이에서 PIV를 이용한 ER유체의 유동특성에 관한연구 (A Study on Flow Characteristics of ERF Between Two Parallel-Plate by Using PlV)

  • 정완보;박영석
    • 한국공작기계학회논문집
    • /
    • 제15권1호
    • /
    • pp.56-62
    • /
    • 2006
  • An experimental investigation was performed to study the characteristics of ER(Electro-Rheological) fluid flow in a horizontal rectangular tube with or without D.C voltage. To determine some characteristics of the ER flow, 2D PIV(Particle Image Velocimetry) technique is employed for velocity measurement. This research found the mean velocity distribution with 0kV/mm, 1.0kV/mm and 1.5kV/mm for Re = 0, 0.62, 1.29 and 2.26. When the strength of the electric field increased, the cluster of ERF are clearly strong along the test tube and the flow rate decreased. In this study, the rheology of ER fluid stagnating or flowing through a dispersion meter will be investigated by PIV method. And then the ER effect, which appears at the ER valves and their appliance will be visualized.

혈류 진단을 위하여 직렬데이터 처리를 하는 다중(128) 채널 초음파 펄스 도플러 시스템에 관한 연구 (A Study on a Multichannel(128) Ultrasound Pulsed Doppler System with Serial Data Processing for Sensing the Blood Flow)

  • Kim, Young-Kil
    • 대한전자공학회논문지
    • /
    • 제23권3호
    • /
    • pp.389-396
    • /
    • 1986
  • A pulsed ultrasonic doppler flowmeter for mesurements of velocity profils in man is described. The device projects a beam of ultrasound in burst of 570 ns duration at 3.5 MHz. The back-scattered signals are processed to produce a signal oxrresponding to the mean velocity over a small region of the flowing stream. The observation range of 112mm is divided into 128 depth channels. The size of this sample volume determines the flowmeter sensitivity and accuracy. The device uses a quadrature detector to detect the direction of the moving target(hemoglobin). The main feature of the novel instrumnet is its simple hardware structure due to sequential signal processing.

  • PDF

섭동법을 이용한 만곡 리뷸릿에 관한 이론적 연구 (Perturbation Analysis of a Meandering Rivulet)

  • 김진호;김호영;강병하;이재헌
    • 설비공학논문집
    • /
    • 제13권12호
    • /
    • pp.1196-1204
    • /
    • 2001
  • The rivulet is a narrow stream of liquid flowing down a solid surface. When the rivulet\`s flow rate exceeds a certain limit, it tends to meander exhibiting the instability of its interface. This analysis performs a perturbation analysis of this meandering rivulet assuming an inviscid flow possessing contact angle hysteresis at the contact line. The analysis reveals that the contact angle hysteresis as well as the velocity difference across the inter-face, strongly induces the instability of the liquid interface. Moreover, when the rivulet veto-city is low, it is predicted that the axisymmetric disturbance amplifies more rapidly than the anti-axisymmetric disturbance, which explains the emergence of the droplet flow at the low velocity regime.

  • PDF

FLUID-GRANULE MIXED FLOIW DOWNSTREAM OF SCOUR HOLE AT OUTLET OF HYDRAULIC STRUCTURE

  • Kim, Jin-Hong;Shim, Myung-Pil;Kim, Kyung-Sub
    • Water Engineering Research
    • /
    • 제3권3호
    • /
    • pp.155-162
    • /
    • 2002
  • This study presents the theoretical approach for volume concentration, velocity profile, and granular discharge on the fluid-granule mixed flow downstream of the scour hole at the outlet of the hydraulic structure. Concept of dilatant model was applied for the stress-strain relationships of fluid-granule mixed flow since the flow downstream of the scour hole corresponds to debris flow, where momentum transfers through particle collisions. Mathematical formulations were derived using momentum equation and stress-strain relation of the fluid-granule mixture. Velocity profile under the assumption of uniform concentration over flowing layer showed the downward convex type. Deposition angle of downstream hump was found to be a function of an upstream slope angle, a dynamic friction angle and a volume concentration irrespective of flow itself, Granular discharge and the overflow depth were obtained with given values of inflow rates. Experimental results showed relatively good agreements with theoretical ones.

  • PDF

고온의 강관 냉각용 삼중 열교환기에 대한 열해석 (Thermal analysis on triple-passage heat exchangers for a hot tube cooling system)

  • 고봉환;박승호;신동신
    • 설비공학논문집
    • /
    • 제11권5호
    • /
    • pp.615-623
    • /
    • 1999
  • The objective of present study is to analyze a hot steel-tube cooling system as a kind of concentric triple-passage heat exchanger, whose inner tube is moving with a constant speed. Velocities and temperatures of an antioxidant gas flowing between inner and outer tubes are calculated theoretically for both laminar and turbulent flow regimes and used to give Nusselt numbers and friction factors with respect to various radius ratios and velocity ratios. In addition, it is shown that heat transfer coefficients based on ratios of average heat fluxes from inner and outer tubes might result in great errors for the temperature distributions of the flows, since the local heat transfer coefficients are dependent on the local heat flux ratios.

  • PDF

Experimental study of bubble flow behavior during flow instability under uniform and non-uniform transverse heat distribution

  • Al-Yahia, Omar S.;Yoon, Ho Joon;Jo, Daeseong
    • Nuclear Engineering and Technology
    • /
    • 제52권12호
    • /
    • pp.2771-2788
    • /
    • 2020
  • Experiments are conducted to study bubble flow behavior during the instability of subcooled boiling under uniform and non-uniform transverse heating. The non-uniform heat distribution introduces nonuniform bubble generation and condensation rates on the heated surface, which is different from the uniform heating. These bubble generation and condensation characteristics introduce a non-uniform local pressure distribution in the transverse direction, which creates an extra non-uniform pressure on the flowing bubbles. Therefore, different bubble flow behavior can be observed between uniform and non-uniform heating conditions. In the uniform heating, bubble velocity fluctuations are low, and the bubbles travel straight along the axial direction. In the non-uniform heating, more fluctuation in the bubble velocity occurs at low mass flow rate and high subcooled inlet temperatures, and reverse flow is observed. Additionally, the bubbles show a zigzag trajectory when they pass through the channel, which indicates the existence of cross flow in the transverse direction.

Proposed Guidelines for Selection of Methods for Erosion-corrosion testing in Flowing Liquids

  • Matsumura, Masanobu
    • Corrosion Science and Technology
    • /
    • 제6권6호
    • /
    • pp.291-296
    • /
    • 2007
  • The corrosion of metals and alloys in flowing liquids can be classified into uniform corrosion and localized corrosion which may be categorized as follows. (1) Localized corrosion of the erosion-corrosion type: the protective oxide layer is assumed to be removed from the metal surface by shear stress or turbulence of the fluid flow. A macro-cell may be defined as a situation in which the bare surface is the macro-anode and the other surface covered with the oxide layer is the macro-cathode. (2) Localized corrosion of the differential flow-velocity corrosion type: at a location of lower fluid velocity, a thin and coarse oxide layer with poor protective qualities may be produced because of an insufficient supply of oxygen. A macro-cell may be defined as a situation in which this surface is the macro-anode and the other surface covered with a dense and stable oxide layer is the macro-cathode. (3) Localized corrosion of the active/passive-cell type: on a metal surface a macro-cell may be defined as a situation in which a part of it is in a passivation state and another in an active dissolution state. This situation may arise from differences in temperature as well as in the supply of the dissolved oxygen. Compared to uniform corrosion, localized corrosion tends to involve a higher wall thinning rate (corrosion rate) due to the macro-cell current as well as to the ratio of the surface area of the macro-anode to that of the macro-cathode, which may be rationalized using potential vs. current density diagrams. The three types of localized corrosion described above can be reproduced in a Jet-in-slit test by changing the flow direction of the test liquid and arranging environmental conditions in an appropriate manner.