• 제목/요약/키워드: flowing amount

검색결과 210건 처리시간 0.024초

공간축소형 댐퍼의 날개개도에 따른 풍량변화 특성평가 (Characteristics of Wind Flow Variation with Wing Development of Space-Reduced Damper)

  • 백근욱;백남도;이명원;강명창
    • 한국기계가공학회지
    • /
    • 제20권7호
    • /
    • pp.113-120
    • /
    • 2021
  • An experimental device was designed to control the opening of a damper via operating the folding blade drive of the device and to control the amount of air flowing through the damper. In addition, an inverter was installed in the blower to control its fan rotation speed and hence the amount of air flowing through the damper. An experimental study was conducted on the opening of the folding blade damper and changes in the rotational speed of the blower. From the results, the theoretical air volume of the folding blade damper and experimental air volume were observed to be in good agreement within an error range of ±3%. As the mass flow rate of the air passing through the folding blade damper increases proportionally with the changes in damper opening and fan rotation speed, the performance of the damper can be controlled proportionally. The mass flow rate was also observed to increase linearly; therefore, the mass flow rate of the air passing through the folding blade damper increases proportionally with changes in the rotation speed of the blower, such that the performance of the damper is proportional to a constant air volume even with varying rotation speeds of the blower.

디젤차량용 통합연료히터의 저온유동성 시험장치개발 (Low Temperature Fluidity Test System of Composited Package Fuel Heater for Diesel Cars)

  • 장용성;윤달환
    • 전기전자학회논문지
    • /
    • 제18권2호
    • /
    • pp.185-191
    • /
    • 2014
  • 본 연구에서는 저온유동성 성능검사 시스템 구현을 통해 디젤 차량용 통합형 연료히터의 성능을 평가한다. 저온유동성 시험장치에서 $+20{\sim}-30^{\circ}C$ 온도범위에 따라 분리형과 통합형 연료히터 성능을 비교하고, 필터 전후에 따라 유압과 시동시간, 히터의 소모전력을 측정한다. 이때 다양한 종류의 필터면적을 사용함으로써 통합형 연료히터와 분리형을 비교한 결과 시동 시간이 23% 향상되었고, 저온시동성능은 19% 정도 향상된다.

냉동방법에 따른 냉동태의 조성아미노산 함량의 변화에 관한 연구 (The Effects of Various Defrosting Methods on the Amount of the Amino Acids in the Frozen Alaska Pollack)

  • 안명수
    • 대한가정학회지
    • /
    • 제17권4호
    • /
    • pp.29-34
    • /
    • 1979
  • Three different defrosting methods were employed in order to investigated the change in the amount of the total proteins and the amino acids in the frozen Alaska Pollack. The sample were defrosted (1) in the air of 25$\pm$3$^{\circ}C$ (2) in the air at the temperature of 4 $\pm$ $1^{\circ}C$(3) in the flowing water of 22$\pm$ $3^{\circ}C$ respectively. The samples were quick-freezed at $-23^{\circ}C$ and stored for 1 month, 2 months, and 3 months keeping the temperature at $-15^{\circ}C$.

  • PDF

흉부물리요법이 인공호흡기환자의 객담량, 폐유순도, 일회호흡량 및 산소포화도에 미치는 효과 (The Effects of Chest Physiotherapy on Sputum Amount, Lung Compliance, Tidal Volume and Oxygen Saturation of Intensive Care Unit Patients Mechanical Ventilated)

  • 서경산;권은옥
    • 중환자간호학회지
    • /
    • 제2권1호
    • /
    • pp.15-25
    • /
    • 2009
  • Purpose: This study investigated the effects of chest physiotherapies on intensive care unit patients mechanical ventilated. Methods: Good lung down position, chest percussion, postural drainage was applied to patients who admitted to ICU. Each patients divided into four groups and each group received different treatments. Sputum amount, lung compliance, tidal volume and oxygen saturation were measured before treatment and immediately, and time flowing. Data was analyzed with frequency, percentage, ANOVA and paired t-test using via SPSSWIN 12.0 program. Results: There were significant differences in variables each characteristics of subjects. Chest percussion increased tidal volume, static lung compliance for the mean time. Desaturation related to suction. Conclusion: Chest percussion influences on lung compliance. Based on this study results and limitation, this study suggests repeated studies in various groups

  • PDF

플레넘 챔버 내의 유동 특성에 관한 실험적 연구 (An Experimental Study on the Flow characteristics in the Plenum Chamber)

  • 정재우;이기형;이창식
    • 한국자동차공학회논문집
    • /
    • 제7권7호
    • /
    • pp.24-31
    • /
    • 1999
  • The MPI engine becomes increasingly popular because it meets two requirements of stringent pollutant emission and the lower fuel consumption. Even though supplies the same amount of fuel to each cylinder , it is hard to precisely control the air-duel ration due to the different amount of air flowing into each cylinder. The uniformity of air-fuel ration in each cylinder is considerably affected by the plenum chamber configuration . This study is focused on experimentally analyzing the flow characteristics within the plenum chamber In the present experiment , steady and valve dynamic state flow tests are performed and the flow field inside the plenum chamber is visualized and measured by utilizing a laser sheet visualization technique and a PTV method. These measured results indicate that the flow structure in the plenum chamber is highly influenced by the plenum chamber configurations, suction flow rates, crank speeds and so on.

  • PDF

Design of an Intelligent Controller for Waste Water Heat Pump Recycled Energy Systems

  • Choo, Yeon-Gyu
    • Journal of information and communication convergence engineering
    • /
    • 제9권4호
    • /
    • pp.375-378
    • /
    • 2011
  • This study is intended to realize an intelligent controller using fuzzy control algorithms in order to recycle energy by recycling the waste water heat discharged by waste water heat collection boilers. Using waste water inflow temperature changes and waste water inflow amount changes as parameters, we present characteristic curves of the number of compressors being operated at fixed speeds and the temperature of hot water being discharged. We propose an intelligent controller that determines the optimum number of compressors being operated at fixed speeds in real time by measuring changes in the temperature and amount of waste water inflows in order to minimize the number of compressors being operated at fixed speeds relative to the waste water load flowing into the waste water heat collection boiler.

복합차체의 낙뢰에 대한 인체 안전성 분석 (Safety Analysis for Passengers of Composite Car-body against Lightning Strikes)

  • 김성욱;최수연;박대원;길경석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.144-150
    • /
    • 2008
  • In this paper, the safety for passengers of composite car-body against lightning strikes was analyzed by the application of an impulse generator which can produce impulse current up to 50 [kA] with 8/20 [us] waveform. Potential difference on inside surface of the car-body was measured as a safety parameter for the passengers against lightning strikes. The potential difference between 20 [cm] distant was 175 [V] at 37.67 [kA], and it corresponded to 875 [V] between 1 [m] distant. The amount of charge flowing a passenger at 100 [kA] impulse current can be estimated to 0.31 [mA s]. This is much less than the limit amount of charge for human body, 30 [mA s] which is presented by Koeppen and Osypka.

  • PDF

동전기적 가스발생방식의 자동윤활주유기 개발 (Development of Automatic Grease Lubricator for Gas Generation Type of Galvanic Electricity)

  • 왕덕현
    • 한국기계가공학회지
    • /
    • 제7권4호
    • /
    • pp.121-127
    • /
    • 2008
  • Automatic grease lubricator is an equipment that provides adequate amount of fresh grease constantly to the shaft and bearings of machines. It minimizes the friction heat and reduces the friction loss of machines to the least. This paper is developing an automatic grease lubricator using a mode of the gas generation type from galvanic electricity. The ultimate goal of this equipment is to lubricate an adequate amount of grease with galvanic corrosion. In an electrolyte, combining anode(Mo) with cathode(Zn) is pressing out hydrogen gas of an galvanic element with galvanic reaction. The characteristics of this method is continuous flowing small hydrogen gas and controling the usage of the amount of the generation of hydrogen gas. The exterior body of grease lubricator was analyzed by Digital Mock-up of CATIA V5 and finite element analysis. The maximum stress is distributed over the outlet part where the grease lubricator suddenly narrowly contracts. The outlet part is analyzed with different constructed angle due to the different loading and setting angles. Using the analyzed design, RP trial products were producted and tested.

  • PDF

위성영상의 시계열 분석을 통한 미기후변화 분석 -대구시 달서구를 대상으로- (A Study on Microclimate Change Via Time Series Analysis of Satellite Images -Centered on Dalseo District, Daegu City-)

  • 백상훈;정응호
    • 한국지리정보학회지
    • /
    • 제12권2호
    • /
    • pp.34-43
    • /
    • 2009
  • 바람길 도입을 통한 도시열섬현상의 저감 방안에 관한 선행연구들을 바탕으로 본 연구에서는 도시화과정을 거치면서 발생하는 토지피복의 변화가 도시공간의 찬공기 생성 및 유동에 어떠한 변화를 일으키는지 분석하였다. 연구 대상지로는 우리나라의 대표적인 극서(劇暑)도시이며 1980년대 이후 주변 지역을 편입하여 도시가 확장된 대구시 내에서도 특히 지표온도의 변화가 크고 1988년 신설되어 급격한 인구 증가가 이루어졌던 달서구를 대상으로 연구를 실시하였다. 시간적 범위로는 1987년, 1997년, 2007년의 여름철 위성영상을 이용하여 20년간의 도시미기후 변화를 연구하였다. 연구결과 자연 토지피복의 감소와 인공 토지피복의 증가는 찬공기 생성 및 유동에 불리하여 도심지에서의 찬공기의 양과 높이가 현저히 낮아졌다. 이는 찬공기 생성 및 유동기능이 토지피복에 의해 영향을 받는 것으로 보였다. 지속적인 찬공기 생성 및 유동의 확보를 위해서는 도시를 둘러싼 주변지역의 공간적 특성을 분석하여 도시개발이나 도시재생을 실시해야 하며, 이를 통해 쾌적하고 건강한 도시조성이 될 수 있을 것으로 사료된다.

  • PDF

하천생태계와 경관복원을 위한 도시소하천의 유지유량확보에 관한 연구 - 울산 무거천을 중심으로 - (A Study on Securing Instream Flow for Restoring Ecosystems and Riverine Aesthetics of a Degraded Urban Stream - Applied to the Mugeo Stream in the Ulsan Metropolitan Area -)

  • 이수식
    • 한국환경과학회지
    • /
    • 제16권5호
    • /
    • pp.649-655
    • /
    • 2007
  • This study was focused on estimating instream flow, and its optimal alternative for securing the required total amount of instream flow was also researched in order to restore ecosystems and riverine aesthetics of the Mugeo Stream. the first tributary of the Taewha River flowing through the center of Ulsan. In this study the hydraulic and hydrologic conditions and water quality were investigated at specific channel reaches and representative stations of the Mugeo Stream to determine a proper estimate of instream flow. And riverine functions, such as the minimum flow, water duality conservation, fish habitat, and recreation, were considered to restore the environmental functions of the stream, As a result, the total amount of $11,500m^3/day$ was set as the target instream flow for the Mugeo Stream. It was chosen as the optimal alternative for securing the total external supply of $10,000m^3/day$ which have to be transfered from the riverbed flow diverted through the Taewha Main river at upstream of Samho bridge. The water duality throughout the Mugeo Stream channels will be improved considerably to 3-4 mg/l of BOD standard if the target instream flow is supplied and sewage is intercepted by the sanitary sewage system.