• Title/Summary/Keyword: flow sheet

Search Result 524, Processing Time 0.025 seconds

Theoretical Heat Flow Analysis and Vibration Characteristics During Transportation of PCS(Power Conversion System) for Reliability (전력변환장치 캐비넷에서의 내부발열 개선을 위한 열유동 분석 및 유통안전성 향상을 위한 진동특성 분석)

  • Joo, Minjung;Suh, Sang Uk;Oh, Jae Young;Jung, Hyun-Mo;Park, Jong-Min
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.28 no.2
    • /
    • pp.143-149
    • /
    • 2022
  • PCS needs to freely switch AC and DC to connect the battery, external AC loads and renewable energy in both directions for energy efficiency. Whenever converting happens, power loss inevitably occurs. Minimization of the power loss to save electricity and convert it for usage is a very critical function in PCS. PCS plays an important role in the ESS(Energy Storage System) but the importance of stabilizing semiconductors on PCB(Printed Circuit Board) should be empathized with a risk of failure such as a fire explosion. In this study, the temperature variation inside PCS was reviewed by cooling fan on top of PCS, and the vibration characteristics of PCS were analyzed during truck transportation for reliability of the product. In most cases, a cooling fan is mounted to control the inner temperature at the upper part of the PCS and components generating the heat placed on the internal aluminum cooling plate to apply the primary cooling and the secondary cooling system with inlet fans for the external air. Results of CFD showed slightly lack of circulating capacity but simulated temperatures were durable for components. The resonance points of PCS were various due to the complexity of components. Although they were less than 40 Hz which mostly occurs breakage, it was analyzed that the vibration displacement in the resonance frequency band was very insufficient. As a result of random-vibration simulation, the lower part was analyzed as the stress-concentrated point but no breakage was shown. The steel sheet could be stable for now, but for long-term domestic transportation, structural coupling may occur due to accumulation of fatigue strength. After the test completed, output voltage of the product had lost so that extra packaging such as bubble wrap should be considered.

Review of the Melting of West Antarctic Ice Shelves in the Amundsen Sea and Its Influence: Research Issues and Scientific Questions (아문젠해 서남극 빙붕 용융과 영향에 대한 고찰: 연구동향 및 과학적 질문)

  • Seung-Tae Yoon
    • Ocean and Polar Research
    • /
    • v.45 no.3
    • /
    • pp.155-172
    • /
    • 2023
  • The collapse of ice shelves is a process that can severely increase the rise of global sea-levels through the reduction of the buttressing effect of ice shelves and the consequent acceleration of the ice flow of ice sheets. In recent years, the West Antarctic ice shelves in the Amundsen Sea, whose buttressing effect is essential for a great part of the West Antarctic ice sheet, have been experiencing the most rapid melting and thinning in the world. The melting of the West Antarctic ice shelves is caused primarily by heat transported by Circumpolar Deep Water (CDW). For this reason, it is important to investigate ice-ocean interactions that could influence the melting of ice shelves and evaluate the stability of West Antarctic ice shelves. A lot of researchers have been actively investigating the West Antarctic ice shelves in the Amundsen Sea. High-impact journals have recognized the importance of and published studies on ice-ocean interactions occurring near and under the ice shelves as well as the connections among ice shelves. However, in situ observations are limited due to extreme weather and sea-ice conditions near the ice shelves; therefore, many scientific questions remain unanswered. This study introduces the characteristics of the Amundsen Sea and investigate the past and latest research issues in this region. This study also gives suggestions regarding important scientific questions and directions for future research that should help early-career scientists take the lead in future research on the melting dynamics of the West Antarctic ice shelves in the Amundsen Sea.

Change in Microstructure with the Gas Quenching Rate during Austempering Treatment of SAE 1078 Steel (SAE 1078 강의 오스템퍼링 열처리시 가스 퀜칭 속도에 따른 미세조직의 변화)

  • Gi-Hoon Kwon;Hyunjun Park;Kuk-Hyun Yeo;Young-Kook Lee;Sang-Gweon Kim
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.36 no.3
    • /
    • pp.121-127
    • /
    • 2023
  • When high carbon steel is heated in an appropriate austenizing temperature range and subjected to austempering, the size and shape of lamellar structure can be controlled. The high carbon steel sheet having the pearlite structure has excellent elastic characteristics because it has strong restoring force when properly rolled, and is applied in a process known as patenting-process using lead bath. In the case of isothermal treatment using lead-medium, it is possible to quickly reach a uniform temperature due to high heat transfer characteristics, but it is difficult to replace it with process technology that requires treatment to remove harmfulness lead. In this study, we intend to develop fluidization technology using garnet powder to replace the lead medium. After heating the high-carbon steel, the cooling rate was changed by compressed air to the vicinity of the nose of the continuous cooling curve, and then maintained for 90 s and then exposed to room temperature. The microstructure of the treated specimens were analyzed and compared with the existing products treated with lead bath. The higher the flow rate of compressed air, the faster the cooling rate to the pearlite transformation temperature, so lamellar spacing decreases and the hardness tends to increase.

A facile synthesis of transfer-free graphene by Ni-C co-deposition

  • An, Sehoon;Lee, Geun-Hyuk;Jang, Seong Woo;Hwang, Sehoon;Yoon, Jung Hyeon;Lim, Sang-Ho;Han, Seunghee
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.129-129
    • /
    • 2016
  • Graphene, as a single layer of $sp^2$-bonded carbon atoms packed into a 2D honeycomb crystal lattice, has attracted much attention due to its outstanding properties. In order to synthesize high quality graphene, transition metals, such as nickel and copper, have been widely employed as catalysts, which needs transfer to desired substrates for various applications. However, the transfer steps are not only complicated but also inevitably induce defects, impurities, wrinkles, and cracks of graphene. Furthermore, the direct synthesis of graphene on dielectric surfaces has still been a premature field for practical applications. Therefore, cost effective and concise methods for transfer-free graphene are essentially required for commercialization. Here, we report a facile transfer-free graphene synthesis method through nickel and carbon co-deposited layer. In order to fabricate 100 nm thick NiC layer on the top of $SiO_2/Si$ substrates, DC reactive magnetron sputtering was performed at a gas pressure of 2 mTorr with various Ar : $CH_4$ gas flow ratio and the 200 W DC input power was applied to a Ni target at room temperature. Then, the sample was annealed under 200 sccm Ar flow and pressure of 1 Torr at $1000^{\circ}C$ for 4 min employing a rapid thermal annealing (RTA) equipment. During the RTA process, the carbon atoms diffused through the NiC layer and deposited on both sides of the NiC layer to form graphene upon cooling. The remained NiC layer was removed by using a 0.5 M $FeCl_3$ aqueous solution, and graphene was then directly obtained on $SiO_2/Si$ without any transfer process. In order to confirm the quality of resulted graphene layer, Raman spectroscopy was implemented. Raman mapping revealed that the resulted graphene was at high quality with low degree of $sp^3$-type structural defects. Additionally, sheet resistance and transmittance of the produced graphene were analyzed by a four-point probe method and UV-vis spectroscopy, respectively. This facile non-transfer process would consequently facilitate the future graphene research and industrial applications.

  • PDF

Studies on Photocatalytic Thin Films($TiO_2$, TiO-N) Manufactured by DC Magnetron Sputtering Method and it's Characteristics for Removal of Pollutants (DC 마그네트론 스퍼터링법을 이용한 광촉매박막($TiO_2$, TiO-N)제조 및 오염물질 제거에 관한 연구)

  • Jeong, Weon-Sang;Park, Sang-Weon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.1
    • /
    • pp.59-66
    • /
    • 2005
  • [ $TiO_2$ ] was deposited by DC magnetron sputtering on glass surface under various sputtering parameters such as discharge power($0.6{\sim}5.2\;kW$, substrate temperature($R.T{\sim}350^{\circ}C$), Ar and $O_2$ flow ratio with $0{\sim}50\;sccm$($Ar+O_2$ 90 sccm) and about 1 mtorr of pressure. TiO-N thin film was prepared under same sputtering conditions for $TiO_2$ thin film except flow ratio($Ar+O_2+N_2$ 90 sccm). The sheet resistance of thin films deposited under these parameters was measured to analyze electronic characteristic and thin film's thickness(${\alpha}$-step), surface roughness(AFM) and formation construction(FE-SEM, XRD) were also measured to draw optimal sputtering parameters. In order to evaluate photo-activity of thin film($TiO_2$, TiO-N) made in optimal parameters for removal of pollutants, toluene among VOCs and Suncion Yellow among reactive dyes were chosen to probe organic compounds for photo-degradation. It was shown that the photo-catalytic thin films had a significant photo-activation for the chosen contaminants and especially TiO-N thin film showed maximum efficiency of 33% for toluene(5 ppm) removal in visible-light range.

Numerical Analysis of Heat Transfer in the Ribbed Channel Inserted with Tape (테이퍼가 설치된 리브(rib)이 있는 채널의 열전달에 대한 수치해석)

  • Kang, Ho-Keun;Ahn, Soo-Whan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.638-644
    • /
    • 2010
  • Numerical predictions of a fully developed turbulent flow through a square duct ($30mm{\times}30mm$) with twisted tape inserts and with twisted tape plus interrupted ribs are respectively conducted to investigate regionally averaged heat transfer and flow patterns. A rib height-to-channel hydraulic diameter(e/$D_h$) of 0.067 and a lengthto-hydraulic diameter(L/$D_h$) of 30 are considered at Reynolds number ranging 8,900 to 29,000. The interrupted ribs are axially arranged on the bottom wall. The twisted tape is 0.1 mm thick carbon steel sheet with diameter of 28 mm, length of 900 mm, and 2.5 turns. Each wall of the square channel is composed of isolated aluminum sections. Two heating conditions are investigated for test channels with twisted tape inserts and rib turbulators: (1) electric heat uniformly applied to four side walls of the square duct, and (2) electric heat uniformly applied to two opposite walls of the square channel. The results show that uneven surface heating enhances the heat transfer coefficient over uniform heating conditions, and significant improvements can be achieved with twisted tape inserts plus interrupted ribs.

Analysis of Hydraulic Characteristics According to Operation of Movable Weir (가동보 운영에 따른 수리학적 특성 분석)

  • Seo, Il Won;Park, Sung Won;Kim, Tae-Won
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.101-101
    • /
    • 2011
  • 현재 국내에서 시행되고 있는 '4대강 살리기 사업'은 하천에서 발생하는 홍수 및 가뭄재해방지를 위한 다양한 공학적 노력을 시도하고 있다. 특히 안정적인 수위 및 유량확보와 홍수방지를 위한 보(weir)가 4대강 유역에 16개 설치되고 있다. 이러한 보 구간에는 고정보와 가동보가 복합적으로 설치되고 있으며 가동보는 그 형상과 운영방식에 따라 다양한 설계방안이 적용되었다. '4대강 살리기 사업' 중 낙동강 23공구의 강정보 공사 구간에는 원호형태의 측면 형상을 갖는 라이징 섹터게이트(Rising sector gate)가 적용되었다. 라이징 섹터게이트는 구조물의 높이가 낮고 수문의 개폐장치가 수문피어 구조물 내에 설치되어 경관이 우수하며, 구조가 간단하여 비체와 수류의 안정성이 뛰어나기 때문에 4개의 공사구간에 적용되었다. 따라서 본 연구에서는 강정보의 가동보 구간 2문 중 1문을 1/100 축척으로 제작하여 가변경사 개수로에 설치하고, 홍수 빈도별 상류 유량 조건과 하류단 수위조건으로 케이스를 정하여 실험을 수행하였다. 본 실험에서 사용한 개수로 장치는 너비 0.6 m, 높이 0.8 m, 그리고 길이 15.0 m(측정가능 구간, 헤드탱크와 테일게이트 부제외)의 개수로 실험장치이다. 측부는 모두 강화유리로 되어 육안관찰 및 계측 시 용이하게 제작되었으며, 순환식 유량 공급장치를 구축하여 수로의 하부에 설치된 유량탱크로부터 계속적으로 순환하도록 설계되었다. 또한 수로 하단으로부터 상단방향으로 약 33 m 지점에 전동 유압식 Jack screw 2기가 설치되어 경사도를 조절할 수 있도록 제작되었다. 유량조절용 판넬의 제어기판에는 디지털 경사계가 설치되어 있기 때문에 보다 정확한 경사도의 조절이 가능하다. 보 모형의 총연장은 53 cm이며 폭은 45 cm이다. 섹터게이트의 게이트부분은 직경 15 cm로 설계하였다. 문주부분을 포함한 모든 모형은 아크릴로 제작하며 레이저의 주사를 방해하지 않으며 투과율을 최대로 할 수 있도록 고강도의 아크릴을 가장 얇게 하여 중공형태를 채택하였다. 실험조건은 우선 보의 운영방안에 따라 게이트의 4가지 개방도를 설정하였고, 특히 평수위조건에서는 보의 상류부에 퇴적된 퇴적물의 세척을 위한 flushing 운영개방도 포함되어 있다. 홍수시에 대한 유량조건은 2년 빈도에 해당하는 유량을 수문의 비율과 상사법칙에 따라 설정하였으며 하류단 수위조건도 동일한 조건에 대한 값을 채택하여 적용하였다. 유동장의 해석을 위해서는 비접촉식 계측방법인 PIV(Particle Image Velocimetry) 시스템을 채택하여 2차원(x-z 방향) laser sheet를 생성하고 주입된 particle에서 반사된 변위(displacement) 정보를 상호상관(cross-correlation)기법으로 유동장을 계산하였다. 또한 수리모형과 동일한 지형격자를 구축하여 3차원 CFD 프로그램인 FLOW-3D로 계산하여 결과를 비교하였다. 특히 flushing 운영방안에 대한 게이트부의 개방도를 세가지(30, 45, $60^{\circ}$)로 구분하여 모의하였고, 적절한 개방도를 제안하고자 하였다. 실험결과는 우선 4가지 운영방안에 대한 가동보 주변에서의 유속장을 파악하였고, 최대유속의 발생위치의 변화를 확인할 수 있었다. 그리고 이에 따른 보의 바닥에서 최대유속이 발생할 경우, 하상보호공 위치와 거리 등에 대해서 분석하였다. 이를 통해 가동보 운영에 따른 다양한 유속구조를 파악할 수 있게 되며 구조적 안정성 확보를 위한 검증자료로 활용될 수 있을 것으로 예상된다. 향후, 가동보 운영방안 중 수세효과(flushing effect)에 대한 효과분석을 위해 게이트부 상류구간에 적절한 입경과 비중의 퇴적물질을 설치하는 연구와 상류부에서의 유입유사농도 및 시간변화에 따른 퇴적에 관한 연구를 수행할 계획이다.

  • PDF

Structure and Physical Property of the Crust of Mid-west Korea: Analysis of Sedimentary Basins in the Namyang and Tando Areas, Kyeonggi Province, Korea (한반도 중서부 지각구조와 물성 연구: 경기도 화성군 남양 및 안산시 탄도지역에 분포하는 퇴적분지의 분석)

  • Park, Sung-Dae;Chung, Gong-Soo;Jeong, Ji-Gon;Kim, Won-Sa;Lee, Dong-Woo;Song, Moo-Young
    • Journal of the Korean earth science society
    • /
    • v.21 no.5
    • /
    • pp.563-582
    • /
    • 2000
  • Two Cretaceous(80-90 Ma) non-marine sedimentary basins, Namyang and Tando Basins, are distributed in the Namyang area, Hwaseonggun and in the Tando area, Ansanshi, Kyungki Province, Korea. The Namyang and Tando Basins are composed of 10 facies, which are pooped into 5 facies associations(FA). FA I consists of massive conglomerate facies, normally graded conglomerate facies and reversely graded conglomerate facies, which is interpreted to have been formed by laminated sandstone facies, massive conglomerate facies(channelized), which is thought to have been formed by sheet flow, stream flow and suspension sedimentation in an alluvial/braided plain environment. FA III consists of massive mudstone(pebbly) facies, laminated mudstone facies, massive sandstone facies and is interbedded by channel-fill conglomerate. It is interpreted to have been deposited by suspension settling during flooding and channel-fill deposition in a floodplain environment. FA IV consists of massive conglomerate facies, normally graded conglomerate facies, massive sandstone facies, normally graded sandstone facies, and laminated sandstone facies and is interbedded with mudstone facies. It is thought to have been deposited by debris flow and turbidity current in a fan-delta environment. FA V consists of massive mudstone facies, laminated mudstone facies, laminated sandstone facies and is interbedded by massive conglomerate bed. It is thought to have been formed by suspension sedimentation and low-density turbidity current in a lake. In the Namyang Basin FA I is distributed in the eastern and southern margin of the basin, FA II in the middle part of the basin as north-south tending band. and FA III in the western part. In the Tando Basin FA II is distributed in the middle part of eastern margin and in the northwestern margin, FA IV in the southwestern part, and FA V in the central part. Correlation of the facies associations shows that FA I and II in the Namyang Basin are distributed in the lower to middle part of stratigraphic sequence and FA III in the upper part of the sequence whereas FA II and IV in the Tando Basin are in the lower to middle part and FA V in the upper part of the sequence. These patterns of facies associations distribution suggest that the Namyang Basin was developed as an alluvial fan and alluvial/braided plain at first and then evolved into a floodplain whereas the Tando Basin was developed as a fan-delta and alluvial/braided plain at first and then evolved into a lake environment.

  • PDF

Evaluation of Fine-Particle Removal Performance of Novel ESP with Highly Durable Chargers and Collectors (고내구성 하전 및 집진 방식 전기집진기의 미세입자 제거 특성)

  • Kim, Hak-Joon;Han, Bang-Woo;Hong, Won-Seok;Shin, Wan-Ho;Song, Dong-Keun;Jung, Sang-Hyeon;Kim, Yong-Jin;Oh, Won-Suk;Hwang, Kyu-Dong;Yoo, Seong-Yeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.4
    • /
    • pp.423-428
    • /
    • 2010
  • Electrostatic precipitators (ESPs) used currently in industries for removing fine particles from semiconductors have to be made of expensive anticorrosive metallic materials in order to maintain their particle-removal performance. To satisfy the economical demands of industries, a novel ESP was developed; in this ESP, the charger is made of carbon fibers and collection plates consist of PET films among which an aluminum sheet is inserted. The ESP was evaluated by changing the voltages applied to the chargers and collection plates, flow rates, and number of charging channels. KCl particles with mean diameters of 100 nm were used, and a scanning mobility particle sizer was used to measure the changes in particle number concentrations upstream and downstream of the ESP. The experimental results showed that more than 90% of the particles were removed by using the ESP containing ionizers with nine channels and 65-mm collection plates at $500\;m^3/hr$ when voltages of 7 kV and 10 kV were applied to the ionizers and collection plates, respectively.

An Experimental Study of Smoke Movement in Tunnel Fires with Natural Ventilation (터널 화재시 자연 배기에 의한 연기 거동에 관한 실험적 연구)

  • 이성룡;김충익;유홍선
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.1-6
    • /
    • 2001
  • In this study, reduced-scale experiments were conducted to understand smoke movements in tunnel fires with the natural ventilation. The 1/20 scale experiments were conducted under the Froude scaling since the smoke movement in tunnels is governed by buoyancy force. Three cases of experiments, in which a natural vent location varied from 1 m, 2 m and 3 m from the fire source symmetrically, were conducted in order to evaluate the effect of the position of ventilation systems on smoke movement. In case of a poo1 whose diameter is 4.36 cm, the temperature of smoke layer passed through the vent was maintained 7~$8^{\circ}c$ less than that of smoke layer without a vent. In case of a pool whose diameter is 5.23 cm, the average velocity passed through the vent was decreased when it was close to the fire source. And the maximum delay time was 3.86s. In CASE 1, the ceiling temperature was decreased by approximately 8$^{\circ}C$ and the vertical temperature was decreased by approximately $7^{\circ}c$. In CASE 2, both ceiling and vertical temperature wert decreased by $3^{\circ}c$ and in CASE 3, they were decreased by $2^{\circ}c$ each. It was confirmed that the thickness of smoke layer was maintained uniformly under the 25% height of tunnel through the visualized smoke flow by a laser sheet and the digital camcoder.

  • PDF