• Title/Summary/Keyword: flow ratio

Search Result 5,898, Processing Time 0.039 seconds

A Study on the Synthesis and Tribological Characteristics of Calcium Sulfonate Grease with Improved Low-temperature Performance (저온 성능이 향상된 Calcium Sulfonate 그리스의 합성 및 트라이볼로지 특성 연구)

  • Gwang-Tae Kim;Hyun-Ho Park;Chang-Seop Lee
    • Applied Chemistry for Engineering
    • /
    • v.34 no.4
    • /
    • pp.434-443
    • /
    • 2023
  • We have investigated the performance improvement of grease by synthesizing calcium sulfonate grease as an alternative to lithium grease, which is widely used globally. Since the composition ratio of the grease, when manufactured, is usually 50% base oil and 50% thickener, using grease as a lubricant in a cryogenic environment is not encouraged due to its inferior low-temperature performance. In this study, we have synthesized three types of calcium sulfonate grease with paraffin oil and PAO-based base oil and thickener. Furthermore, lithium grease was synthesized via saponification with PAO-based base oil, lithium hydroxide, 12-hydroxystearic acid, and sebacic acid. We have measured low-temperature characteristics using a rheometer and low-temperature torque meter, and tribology characteristics were obtained using a four-ball lubricant tester and schwingung reibung verschleiß (SRV). As a result, the flow point of the calcium sulfonate grease synthesized with a PAO-based base oil and thickener was found to be -40℃, overcoming the existing calcium sulfonate grease's low-temperature limitation. Moreover, the synthesized calcium sulfonate grease showed low-temperature performance similar to that of lithium grease synthesized with PAO base oil, but superior anti-wear, extreme pressure, coefficient of friction, heat resistance, adhesion, and corrosion resistance. It is thus expected to commercially replace the existing lithium grease.

Injection Characteristics Evaluation of Conductive Grout Material According to Carbon Fiber Mixing Ratio (탄소섬유 배합비에 따른 전도성 그라우트 재료의 주입특성평가)

  • Hyojun Choi;Wanjei Cho;Hyungseok Heo;Teawan Bang;Chanyoung Yune
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.1
    • /
    • pp.15-23
    • /
    • 2023
  • The grouting method is a method of construction for the purpose of waterproofing and reinforcing soft ground. When grout is injected into the ground, there are various types of penetration and diffusion of grout depending on the shape of the ground, the size of soil, the porosity, and the presence or absence of groundwater. the current situation. Therefore, in this study, to investigate the penetration performance of the grouting to conductive material, laboratory tests were performed on the addition of the conductive material. In the injection test, 0%, 3%, and 5% of the mixed water were added as conductive materials to the grout, and the original ground condition was composed of various types of ground composed of gravel and silica sand. Conductive grout is injected by pressure into the model ground using a dedicated injection device, and the injection time (t), pressure (p), flow rate (v) and injection amount (q) are measured, and the hardened body injected in the model ground is collected. Penetration performance was evaluated. In the results of the grout injection experiment, the amount of conductive material used and the grout injection rate showed an inverse relationship, and it was confirmed that the penetration pattern was changed according to the size of the soil particles in the model ground. The grout containing the conductive material has relatively good penetration into the ground and excellent strength and durability of the hardened body, so it was judged that it could be used as an additive for measuring the penetration range of the grout.

A Case Study on the Interior design characteristics of Integrated CCTV Control Center - Focused at Human Factor Design aspect (CCTV 통합관제센터의 실내공간특성에 대한 사례분석연구 - 인간공학디자인(HFD)의 관점에서)

  • Han, Ji Eun;Kwon, Gyu Hyun
    • Design Convergence Study
    • /
    • v.16 no.3
    • /
    • pp.103-118
    • /
    • 2017
  • It is expected that the integrated control service of the public sector will be increased for the safety of citizens in the future. Therefore, In this study, we analyzed the classification of CCTV control center and the characteristics of interior design. The survey was conducted at eight control centers in Seoul that were constructed since 2007 and analyzed according to the criteria of general matters, services, spatial basic information, spatial structure, and internal structure. The results of the survey are summarized as follows. Based on the results of the study, the Integrated Control Center is a space where the ratio of the physical environment is not high but performs important tasks for the citizens of the city, which are operated 24 hours a day, and security and security. It is characterized by the efficient space allocation for the treatment, the design of the moving line, and the connection according to the urgent work flow. The results of this study are expected to be used as basic data for other integrated control center environment.

Effect of Void Formation on Strength of Cemented Material (고결 지반 내에 형성된 공극이 강도에 미치는 영향)

  • Park, Sung-Sik;Choi, Hyun-Seok;Kim, Chang-Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.2C
    • /
    • pp.109-117
    • /
    • 2010
  • Gas hydrate dissociation can generate large amounts of gas and water in gas hydrate bearing sediments, which may eventually escape from a soil skeleton and form voids within the sediments. The loss of fine particles between coarse particles or collapse of cementation due to water flow during heavy or continuous rainfall may form large voids within soil structure. In this study, the effect of void formation resulting from gas hydrate dissociation or loss of some particles within soil structure on the strength of soil is examined. Glass beads with uniform gradation were used to simulate a gas hydrate bearing or washable soil structure. Glass beads were mixed with 2% cement ratio and 7% water content and then compacted into a cylindrical sample with five equal layers. Empty capsules for medicine are used to mimic large voids, which are bigger than soil particle, and embedded into the middle of five equal layers. The number, direction, and length of capsules embedded into each layer vary. After two days curing, a series of unconfined compression tests is performed on the capsule-embedded cemented glass beads. Unconfined compressive strength of cemented glass beads with capsules depends on the volume, direction and length of capsules. The volume and cross section formed by voids are most important factors in strength. An unconfined compressive strength of a specimen with large voids decreases up to 35% of a specimen without void. The results of this study can be used to predict the strength degradation of gas hydrate bearing sediments in the long term after dissociation and loss of fine particles within soil structure.

Fundamental Properties of Mortar with Magnet-Separated Converter-Slag Powder as SCM (자력 선별 전로슬래그 미분말을 결합재로 활용한 모르타르의 기초특성)

  • Beom-Soo Kim;Sun-Mi Choi;Jin-Man Kim
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.3
    • /
    • pp.161-168
    • /
    • 2023
  • Converter slag is a by-product generated by refining the pig iron produced into molten steel in the blast furnace, occupying about 15 % of the weight of steel production. It has a high free-CaO content that can generate expansion cracks when used for concrete aggregate. This is the main reason to make it difficult to recycle. To solve this problem, government guideline requires that converter slag has to be aged in an open yard for 90 days. However, aging can not be perfectly performed because it entails time and cost. In this study, we tried to investigate the applicability of converter slag as a cementitious material rather than an aggregate by mixing converter slag with mortar formulations. According to the EDS results of the converter slag in the experiment, we found that screening in the aggregate phase was more effective than that in the powder phase. When the particles separated by a magnet in the aggregate state were pulverized and used for concrete up to a 15 % replacement ratio, various engineering characteristics, such as flow, length change, and compressive strength, showed engineering characteristics similar to those of the control mix.

Development of Ceramide NP Analysis Method in Cosmetic Formulations Using Liquid Chromatography (액체크로마토그래피를 이용한 화장품 제형 내 세라마이드엔피 분석법 확립)

  • Ye Ji Lee;Young Eun Kim;Jae Yong Seo;Hyun Dae Cho
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.49 no.4
    • /
    • pp.291-298
    • /
    • 2023
  • In this study, a quantitative analysis method was developed using high-performance liquid chromatography (HPLC) to analyze the content of ceramide NP in lotion, cream, and cleanser formulations in cosmetics. The analysis was performed using a C18 column, and the mobile phase was set at a ratio of 70 : 30 for acetonitrile and methanol, the flow rate was set to 0.8 mL/min, and the column temperature was set to 20 ℃. The method was verified by analyzing specificity, linearity, limit of detection, limit of quantitation, accuracy, and precision in accordance with the ICH guidelines. As a result of validating the method, the linearity of the calibration curve was excellent (R2 = 0.99984). The accuracy of the lotion, cream, and cleanser formulations was confirmed with a recovery rate ranging from 95.11% to 100.48%. The precision analysis showed a low relative standard deviation (RSD) of less than 0.26%. The limit of detection was 0.902 ㎍/mL, and the limit of quantitation was 2.733 ㎍/mL. Through this quantitative analysis method of ceramide NP applied in cosmetics, it is expected to assist in the quality control of products by enabling measurement even when it is difficult to separate the main peak due to the influence of interfering substances.

A Simple Design of an Imaging System for Accurate Spatial Mapping of Blood Oxygen Saturation Using a Single Element of Multi-wavelength LED (혈중 산소 포화도의 정확한 공간 매핑을 위한 다중 파장 LED 단일소자를 활용한 이미징 시스템 설계)

  • Jun Hwan Kim;Gi Yeon Yu;Ye Eun Song;Chan Yeong Yu;Yun Chae Jang;Riaz Muhammad;Kay Thwe Htun;Ahmed Ali;Seung Ho Choi
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.450-464
    • /
    • 2023
  • Pulse oximetry, a non-invasive technique for evaluating blood oxygen saturation, conventionally depends on isolated measurements, rendering it vulnerable to factors like illumination profile, spatial blood flow fluctuations, and skin pigmentation. Previous efforts to address these issues through imaging systems often employed red and near-infrared illuminations with distinct profiles, leading to inconsistent ratios of transmitted light and the potential for errors in calculating spatial oxygen saturation distributions. While an integrating sphere was recently utilized as an illumination source to achieve uniform red and near-infrared illumination profiles on the sample surface, its bulkiness presented practical challenges. In this work, we have enhanced the pulse oximetry imaging system by transitioning illumination from an integrating sphere to a multi-wavelength LED configuration. This adjustment ensures simultaneous emission of red and near-infrared light from the same position, creating a homogeneous illumination profile on the sample surface. This approach guarantees consistent patterns of red and near-infrared illuminations that are spatially uniform. The sustained ratio between transmitted red and near-infrared light across space enables precise calculation of the spatial distribution of oxygen saturation, making our pulse oximetry imaging system more compact and portable without compromising accuracy. Our work significantly contributes to obtaining spatial information on blood oxygen saturation, providing valuable insights into tissue oxygenation in peripheral regions.

Strategies for Managing Dementia Patients through Improving Oral Health and Occlusal Rehabilitation: A Review and Meta-analysis

  • Yeon-Hee Lee;Sung-Woo Lee;Hak Young Rhee;Min Kyu Sim;Su-Jin Jeong;Chang Won Won
    • Journal of Korean Dental Science
    • /
    • v.16 no.2
    • /
    • pp.128-148
    • /
    • 2023
  • Dementia is an umbrella term that describes the loss of thinking, memory, attention, logical reasoning, and other mental abilities to the extent that it interferes with the activities of daily living. More than 50 million individuals worldwide live with dementia, which is expected to increase to 131 million by 2050. Recent research has shown that poor oral health increases the risk of dementia, while oral health declines with cognitive decline. In this narrative review, the literature was based on the "hypothesis" that dementia and oral health have a close relationship, and appropriate oral health and occlusal rehabilitation treatment can improve the quality of life of patients with dementia and prevent progression. We conducted a literature search in PubMed and Google Scholar databases, using the search terms "dementia," "major neurocognitive disorder," "dentition," "occlusion," "tooth loss," "dental prosthesis," "dental implant," and "occlusal rehabilitation" in the title field over the past 30 years. A total of 131 studies that scientifically addressed dementia, oral health, and/or oral rehabilitation were included. In a meta-analysis, the random effect model demonstrated significant tooth loss increasing the dementia risk 3.64-fold (pooled odds ratio=3.64, 95% confidence interval [2.50~5.32], P-value=0.0348). Tooth loss can be an important indicator of cognitive function decline. As the number of missing teeth increases, the risk of dementia increases. Loss of teeth can lead to a decrease in the ascending information to the brain and reduced masticatory ability, cerebral blood flow, and psychological atrophy. Oral microbiome dysbiosis and migration of key bacterial species to the brain can also cause dementia. Additionally, inflammation in the oral cavity affects the inflammatory response of the brain and the complete body. Conversely, proper oral hygiene management, the placement of dental implants or prostheses to replace lost teeth, and the restoration of masticatory function can inhibit symptom progression in patients with dementia. Therefore, improving oral health can prevent dementia progression and improve the quality of life of patients.

Study on Enhancement of Ammonia Generation for Effective Collision Frequency (유효충돌빈도를 고려한 암모니아 생성 증대기법 연구)

  • Sejin Kim;Yongseok CHoi;Hyunchul Park
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.6
    • /
    • pp.1-8
    • /
    • 2023
  • Research, such as developing alternative energy in the transportation field, including aviation, is being actively conducted to solve the issue of current climate change. Interest in ammonia fuel as a carbon free energy (CFE) source is increasing due to the ease of liquefaction and transportation and similarity in energy density to that of methanol. However, explosiveness and toxicity of ammonia make it difficult to handle. Therefore, in this study, stable ammonia production was attempted using relatively easy-to-handle urea water solution (UWS). High temperature steam was used to promote the hydrolysis of ammonia. In order to determine the causes for ammonia production below the theoretical equivalent ratio, it was suggested that there were not enough collisions to promote the hydrolysis based on the kinetic theory of gases. The hydrolysis of unreacted isocyanic acid (HNCO) was tested according to the change in water supply. As a result, an increased amount of ammonia produced was confirmed. The increased amount of ammonia produced in a certain section was dependent on the steam temperature and the flow rate of water supplied.

Myocardial Coverage and Radiation Dose in Dynamic Myocardial Perfusion Imaging Using Third-Generation Dual-Source CT

  • Masafumi Takafuji;Kakuya Kitagawa;Masaki Ishida;Yoshitaka Goto;Satoshi Nakamura;Naoki Nagasawa;Hajime Sakuma
    • Korean Journal of Radiology
    • /
    • v.21 no.1
    • /
    • pp.58-67
    • /
    • 2020
  • Objective: Third-generation dual-source computed tomography (3rd-DSCT) allows dynamic myocardial CT perfusion imaging (dynamic CTP) with a 10.5-cm z-axis coverage. Although the increased radiation exposure associated with the 50% wider scan range compared to second-generation DSCT (2nd-DSCT) may be suppressed by using a tube voltage of 70 kV, it remains unclear whether image quality and the ability to quantify myocardial blood flow (MBF) can be maintained under these conditions. This study aimed to compare the image quality, estimated MBF, and radiation dose of dynamic CTP between 2ndDSCT and 3rd-DSCT and to evaluate whether a 10.5-cm coverage is suitable for dynamic CTP. Materials and Methods: We retrospectively analyzed 107 patients who underwent dynamic CTP using 2nd-DSCT at 80 kV (n = 54) or 3rd-DSCT at 70 kV (n = 53). Image quality, estimated MBF, radiation dose, and coverage of left ventricular (LV) myocardium were compared. Results: No significant differences were observed between 3rd-DSCT and 2nd-DSCT in contrast-to-noise ratio (37.4 ± 11.4 vs. 35.5 ± 11.2, p = 0.396). Effective radiation dose was lower with 3rd-DSCT (3.97 ± 0.92 mSv with a conversion factor of 0.017 mSv/mGy∙cm) compared to 2nd-DSCT (5.49 ± 1.36 mSv, p < 0.001). Incomplete coverage was more frequent with 2nd-DSCT than with 3rd-DSCT (1.9% [1/53] vs. 56% [30/54], p < 0.001). In propensity score-matched cohorts, MBF was comparable between 3rd-DSCT and 2nd-DSCT in non-ischemic (146.2 ± 26.5 vs. 157.5 ± 34.9 mL/min/100 g, p = 0.137) as well as ischemic myocardium (92.7 ± 21.1 vs. 90.9 ± 29.7 mL/min/100 g, p = 0.876). Conclusion: The radiation increase inherent to the widened z-axis coverage in 3rd-DSCT can be balanced by using a tube voltage of 70 kV without compromising image quality or MBF quantification. In dynamic CTP, a z-axis coverage of 10.5 cm is sufficient to achieve complete coverage of the LV myocardium in most patients.