• Title/Summary/Keyword: flow meter

Search Result 596, Processing Time 0.029 seconds

Cryogenic Systems for HTS Power Cables

  • Yeom, Han-Kil;Koh, Deuk-Yong;Lee, Bong-Kyu;Kim, Ig-Seang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.133-135
    • /
    • 2003
  • Cryogenic systems are requirement for the operation of HTS power cables. In general, HTS power cables require temperature below 77K, a temperature that can be achieved from the liquid nitrogen at latm or sub-cooled LN2 above latm. HTS power cable needs sufficient refrigeration to overcome its low temperature heat loading. This loading typically cones in two forms : (1) heat leaks from the surroundings and (2) internal heat generation. This paper explains the cooling test system of 10m HTS power cable. This system is composed of storage dewar, auto fill system, core cryostat and cold-box. Storage dewar is a LN2 storage tank and auto fill system is a LN2 supply device to the sub-cooler, Core cryostat is a LN2 flow line. Cold box is a control unit of temperature and flow rate. It is composed of control valve, flow meter, sub-cooler and circulation pump, etc..

A Study on the Characteristics of the Electronic EGR Valve for Gasoline Engine (가솔린엔진용 E-EGR 밸브 특성에 관한 연구)

  • Park, Cheol-Woong;Kim, Chang-Gi
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.1
    • /
    • pp.127-133
    • /
    • 2008
  • Since the 1960's, exhaust gas recirculation(EGR) has been used effectively in spark ignition(SI) engines to control the exhaust emissions of the oxides of nitrogen(NOx). The most important requirements for the application of EGR systems to conventional SI engines are controllable flow rate and good dynamic response. In order to evaluate the characteristics of the electronic EGR valve, a test bench which is consisted of blower, heater, air flow meter and driving unit for electronic EGR valve was set up to simulate engine operating conditions. During the tests, the valve actuation parameters were controlled and the valve lifts and flow rates were measured to infer the characteristics of EGR valve. The results confirmed the capabilities of mathematical analysis and it seems that the correction for the valve lift and potentiometer output is necessary to achieve precise control of EGR rates.

A Study on the Characteristics in Design and Made of Eddy Current Flowmeter (와전류식 전자유량계 설계제작에 대한 실험적 특성연구)

  • 황종선;남호윤;이용범;김용균;김동화
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.281-284
    • /
    • 1997
  • In this paper, the eddy current flow meter with 4-coil group is designed and made on the basis of theory, and its characteristics is considered through dry test flow experiments. The biggest output signal varied with wave form and frequency, and 900Hz in rectangular wave, 27.12kHz in sine wave. The conductivity is bigger, the output signal is bigger and has a linearity between both relation, and also The Magnetic Reynolds Number and output characteristics. The flow faster and the output singnal is bigger.

  • PDF

A Study on the Modification Method of Flow Data in the Sewage System (하수관거 유량자료의 보정방법에 관한 연구)

  • Kim, Dae-Geun;Gong, Min-Geun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.17 no.4
    • /
    • pp.495-502
    • /
    • 2003
  • In order to modify incorrect flow data in the sewage system, the method using the stage-discharge relation and hydraulic characteristic curve of sewer pipe are applied. The modified data were verified with field measured data and the infiltration analysis using the modified data was carried out. When flowrate were measured using the flow-meter in fair weather, the stage data were comparatively consistent but velocity data were very poor for the most part. Therefore, it was recommended that sewage flowrate variation characteristic curve and infiltration were computed using the modified data on the basis of stage data. Especially, in the case of using the hydraulic characteristic curve, extrapolation results of the rainy season flowrate using regression curve on the basis of the data in fair weather were also reasonable.

A study on a Characteristics of Eddy current Flow meter (와전류식 전자 유량계의 출력특성 연구)

  • Hwang, J.S.;Nam, H.Y.;Lee, Y.B.;Kim, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1096-1099
    • /
    • 1996
  • In this paper, the eddy current flowmeter with 4-coil is designed and made on the basis of theory, and its characteristics is considered through dry test and flow experiments. The biggest output signal varied with wave wave form frequency, and 900Hz in rectangular wave, 27.12kHz in sine wave. The conductivity is bigger, the output signal is bigger and has a linearity between both relation, and also The Magnetic Reynolds Number and output characteristics The flow faster and the output signal is bigger.

  • PDF

Design and Implementation of a Hybrid-Type Mass Flow Controller (하이브리드형 질량 유량 제어기의 설계 및 실현)

  • 이명의;정원철
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.2
    • /
    • pp.63-70
    • /
    • 2003
  • In this paper, an MFC (Mass Flow Controller) which is widely used in many semiconductor manufacturing processes for controlling the mass flow rate of a gas is designed and implemented using the PIC 16F876 of Microchip, Inc. The MFC implemented in this thesis has the form of hybrid-type, i.e., the mixed-type of the analog-type MFC, which has many problems such as low accurary, and digital-type MFC, which use an expensive DSP (Digital Signal Processor) and an ADC (Analog to Digital Convertor) with high precision. The MFC is consists of the sensor unit, the control unit and the actuator unit, and it has used the automatic calibration algorithm and the reference table method for the improvement of the performance.

  • PDF

Feedwater Flow-rate Evaluation of Nuclear Power Plants Using Wavelet Analysis and Artificial Neural Networks (웨이블릿 해석과 인공 신경회로망을 이용한 원자력발전소의 급수유량 평가)

  • Yu, Sung-Sik;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.5 no.4 s.17
    • /
    • pp.47-53
    • /
    • 2002
  • The steam generator feedwater flow-rate in a nuclear power plant was estimated by means of artificial neural networks with the wavelet analysis for enhanced information extraction. The fouling of venturi meters, used for steam generator feedwater flow-rate in pressurized water reactors, may result in unnecessary plant power derating. The back-propagation network was used to generate models of signals for a pressurized water reactor Multiple-input, single-output hetero-associative networks were used for evaluating the feedwater flow rate as a function of a set of related variables. The wavelet was used as a low pass filter eliminating the noise from the raw signals. The results have shown that possible fouling of venturi can be detected by neural networks, and the feedwater flow-rate can be predicted as an alternative to existing methods. The research has also indicated that the decomposition of signals by wavelet transform is a powerful approach to signal analysis for denoising.

Experimental Study on Flows within an Unshrouded Centrifugal Impeller Passage(II)-on the Influence of Flow Rate- (개방형 원심회전차의 내부유동장에 관한 실험적 연구(2)-유량에 따른 영향-)

  • Kim, Seong-Won;Jo, Gang-Rae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.10
    • /
    • pp.3251-3261
    • /
    • 1996
  • Flows were measured in an unshrouded centrifugal impeller. By using a single slanted hot-wire probe and a Kiel probe mounted on the impeller hub disk, the 3-D relative velocities and the rotary stagnation pressures were measured in seven circumferential planes between the inlet and outlet of the impeller rotating at 700 rpm, which diameter is 0.39 meter, and the static pressures and the slip factor at the impeller outlet were estimated from the measured values. Measurements were made for three flow rates corresponding to zero incidence and two others with the greater and the smaller one than zero. From the measured data in these flow rates, the followings were investigated in the impeller passage, the variation of the primary and secondary flows, the leakage flows, the wake's position and its size, the static pressure rise and the loss production mechanism. Furthermore the static pressure and the slip factor were compared with the results of inviscid Quasi-3D calculation.

Effects of Interferential Current Stimulation on the Peripheral Blood Velocity in Healthy Subjects (간섭전류자극이 말초 혈류속도에 미치는 영향)

  • Park Jang-Sung;Lee Jae-Hyoung
    • The Journal of Korean Physical Therapy
    • /
    • v.11 no.2
    • /
    • pp.37-42
    • /
    • 1999
  • The purpose of this study was to determine whether percutaneous interferential current stimulation on thoracic sympathetic ganglia with amplitude modulated frequency (AMF) $90\~100$ bps and subthreshold of muscle contraction for 10 minutes on peripheral blood flow velocity in healthy subjects. Thirty-seven healthy volunteers were assigned randomly into an experimental group (n=25) and a control group (n=12). the experimental group received interferential current stimulation with subthreshold of the muscle contraction of current at AMF $90\~100$ bps on $1st\~5th$ thoracic sympathetic ganglial region for 10 minutes. The control group received same handling and electode placement, but no current was applied. Using a Doppler blood flow meter, the radial arterial blood flow velocities and the pulse raters were determined for two-way analysis of variance for repeated measures on time and group. There were no significant difference between the two groups with respect to the changes in arterial blood flow velocity and pulse rate over the four measurement times. Interferential current stimulation did not change in mean blood flow velocity and pulse rate. We conclude that interferential current stimulation on the thoracic sympathetic ganglia, as used in this study, did not dilate peripheral artery. This results suggests that interferential current stimulation dose not alter the activtiy of sympathetic nerve.

  • PDF

Experimental and Numerical Analysis of Heat Transfer Phenomena in a Sensor Tube of a Mass Flow Controller (질량 유량계 센서관에서의 열전달 현상에 대한 수치적 해석 및 실험적 연구)

  • Jang, Seok-Pil;Kim, Sung-Jin;Choi, Do-Hyung
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.154-161
    • /
    • 2000
  • As a mass flow controller is widely used in many manufacturing processes for controlling a mass flow rate of gas with accuracy of 1%, several investigators have tried to describe the heat transfer phenomena in a sensor tube of an MFC. They suggested a few analytic solutions and numerical models based on simple assumptions, which are physically unrealistic. In the present work, the heat transfer phenomena in the sensor tube of the MFC are studied by using both experimental and numerical methods. The numerical model is introduced to estimate the temperature profile in the sensor tube as well as in the gas stream. In the numerical model, the conjugate heat transfer problem comprising the tube wall and the gas stream is analyzed to fully understand the heat transfer interaction between the sensor tube and the fluid stream using a single domain approach. This numerical model is further verified by experimental investigation. In order to describe the transport of heat energy in both the flow region and the sensor tube, the Nusselt number at the interface between the tube wall and the gas stream as well as heatlines is presented from the numerical solution.

  • PDF