• Title/Summary/Keyword: flow loss

Search Result 2,458, Processing Time 0.026 seconds

Application with Winglet-Type Vortex Generators in an In-line Tube Arrangement (정렬형 관 배열에서의 와류발생기 응용)

  • Kwak, Kyung-Min
    • Journal of Energy Engineering
    • /
    • v.14 no.4 s.44
    • /
    • pp.241-247
    • /
    • 2005
  • Heat transfer enhancement and pressure loss penalty caused by three-row winglets built in three-row tube-bundles in an in-line arrangement, are compared between 'common flow up' and 'common flow down' winglet configurations. The 'common flow down' winglet-pairs recommended by the previous researchers bring about $10\%$ to $25\%$ increase in heat transfer enhancement and $20\%$ to $35\%$ increase in pressure loss penalty, in comparison with fin-tube bundles without winglets. For the 'common flow up' winglet-pairs, the spanwise distance between the trailing edges (${\Delta}y$) of winglet pairs was changed and investigated. Two types ot winglet are applied for triangular and rectangular shapes. In the triangular winglets with ${\Delta}y$=5 mm in in-line tube bundles, the heat transfer increased up to $10\%$, and simultaneously the pressure loss decreased by $8\%$ to $15\%$ for the Reynolds number (based on two times channel height) ranging from 300 to 2700, when the 'common flow up' winglets were built in. The performance of fin-tube bundles with triangular winglets is much superior to the rectangular one, because of the smaller pressure-loss penalty.

Impact of monthly arteriovenous fistula flow surveillance on hemodialysis access thrombosis and loss

  • Ara Ko;Miyeon Kim;Hwa Young Lee;Hyunwoo Kim
    • Journal of Medicine and Life Science
    • /
    • v.20 no.3
    • /
    • pp.115-125
    • /
    • 2023
  • Arteriovenous fistula flow dysfunction is the leading cause of vascular access thrombosis and loss in patients undergoing hemodialysis. However, data regarding the influence of access flow rate measurements on the long-term outcomes of access are limited. This study aims to identify accesses at a high risk of thrombosis and loss among patients undergoing hemodialysis by measuring the access flow rate and exploring an optimal threshold value for predicting future access thrombosis. We enrolled 220 patients with arteriovenous fistula undergoing hemodialysis. The primary outcome was the occurrence of access thrombosis. Access flow rates were measured monthly using the ultrasound dilution method and were averaged using all measurements from patients with patent access. In patients experienced access thrombosis, those immediately before the thrombosis were selected. Using these data, we calculated the access flow rate threshold for thrombosis occurrence by analyzing the receiver operating characteristic curve, and the patients were divided into two groups according to whether access flow rates were higher or lower than 400 mL/min. During a median follow-up period of 3.1 years, 4,510 access flows were measured (median measurements per patient, 33 times; interquartile range, 11-54). A total of 65 access thromboses and 19 abandonments were observed. Access thrombosis and loss were higher in the lowflow group than in the high-flow group. This study revealed that low access flow rates are strongly associated with access thrombosis occurrence and subsequent loss of arteriovenous fistulas in patients undergoing hemodialysis.

An Interal Flow Analysis of Turbo Pump Inducer (터보펌프 인듀서의 내부 유동 해석)

  • Shim, Chang-Yeul;Kang, Shin-Hyoung
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.631-636
    • /
    • 2001
  • The internal flow in the rocket pump inducer of LE-7 engine for H-II rocket was predicted at design and off-design flow rates using CFD code, CFX- Tascflow. In this numerical study, the performance curve of inducer coressponding to flow rates variation and the internal flow in the front of blade leading edge show good agreement between the calculations and the measurements. Backflow is appeared at suction side of leadinge edge tip, and this region is extended to upstream as flowrate decrease. Because of backflow, pressure loss coressponding to meridinal coordinate occupy 50% from inlet domain to leading edge. By this phenomena, pressure loss in front of blade leading edge take a great effect to inducer performance.

  • PDF

Two-Phase Flow Characteristics in an Adiabatic Horizontal Tube (단열 수평관내 이상류의 유동특성)

  • Choi, B.H.
    • Journal of Power System Engineering
    • /
    • v.8 no.1
    • /
    • pp.36-40
    • /
    • 2004
  • Two-phase loop systems using the latent heat capacity of their working fluids can meet the increasing power requirements and are well suited to thermal management systems of future large applications, due to its abilities to handle large heat loads and to provide them at uniform temperatures regardless of the changes in the heat loads. Therefore some experiments on the effect of the gas and liquid superficial velocities, $j_G,\;j_L$ on flow pattern transition, void fraction and frictional pressure loss were performed on a co-current air-water flow in an adiabatic horizontal tube. The flow patterns were depended on the superficial velocity of each phase. It snowed that the increasing $j_L$, resulted in a significant increase in the frictional pressure loss for all flow patterns, at a constant $j_G$. The experimental results were also evaluated with some of existing models and correlations.

  • PDF

A Study on the Estimation of River Management Flow in Urban Basin (도시유역의 하천유지용수 산정에 관한 연구)

  • 이영화
    • Journal of Environmental Science International
    • /
    • v.5 no.3
    • /
    • pp.377-385
    • /
    • 1996
  • This study aims at the estimation of a river management flow in urban basin analyzing Sinchun basin to be the tributary of Kumho river basin. The river management flow has to satisfy a low flow as natural flow and an environmental preservation flow estimated by a dilution flow to satisfy a target water quality in drought flow. Therefore for the estimation of a river management flow in Sinchun in this study, first Tank model as a basin runoff model estimates a low flow, a drought flow from a flow duration curve in Sinchun, second QUAL2E model as water quality model simulates water quality in Sinchun and estimates environmental preservation flow to satisfy a target water qua%its, BOD 8 mg/l by a dilution flow derived from Kumho river, Nakdong river and around water. And the river management flow is estimated by addition of a use flow and a loss flow to more flow between a low-flow and an environmental preservation flow.

  • PDF

Numerical Analysis on the Blade Tip Clearance Flow in the Axial Rotor (III) - Evaluation of Tip Leakage Loss and Reduction of Efficiency near Blade Tip Clearance Region of a Rotor - (축류 회전차 익말단 틈새유동에 대한 수치해석 (III) - 회전차 익말단의 누설손실과 효율저하에 대한 평가 -)

  • Ro, Soo-Hyuk;Cho, Kang-Rae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.9
    • /
    • pp.1113-1120
    • /
    • 1999
  • Leakage vortices fonned near the blade tip cause an increase of total pressure loss near the casing endwall region and as a result, the efficiency of rotor decreases. The reduction of rotor efficiency is related to the size of tip clearance. In this study, the three-dimensional flow fields in an axial flow rotor were calculated with varying tip clearance under various flow rates, and the numerical results were compared with experimental ones. The effects of tip clearance and the of attack on the leakage vortex and overall performance, and the los9 distributions were investigated through numerical calculations. In this study, tip leakage flow rate and total pressure loss due to the tip clearance were evaluated using numerical results and approximate equations were presented to evaluate the reduction of rotor efficiency due to the tip leakage flow.

Numerical Study on Tip Clearance Effect on Performance of a Centrifugal Compressor (익단간극이 원심압축기 성능에 미치는 영향에 관한 수치해석적 연구)

  • Eum, Hark-Jin;Kang, Shin-Hyoung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.3
    • /
    • pp.389-397
    • /
    • 2003
  • Effect of tip leakage flow on through flow and performance of a centrifugal compressor impeller was numerically studied using CFX-TASC flow. Seven different tip clearances were used to consider the influence of tip clearance on performance. Secondary flow and loss factor were evaluated to understand the loss mechanism inside the impeller due to tip leakage flow. The calculated results were circumferentially averaged along the passage and at the impeller exit for quantitative discussion. Tip clearance effect on Performance could be decomposed into inviscid and viscous components using one dimensional equation. The inviscid component is related with the specific work reduction and the viscous component is related with the additional entropy generation. Two components affected Performance equally. while efficiency drop was mainly influenced by viscous loss. Performance and efficiency drop due to tip clearance were proportional to the ratio of tip clearance to exit blade height. A simple model suggested in the present study predict performance and efficiency drop quite successfully.

Flow Distribution and Pressure Loss in Subchannels of a Wire-Wrapped 37-pin Rod Bundle for a Sodium-Cooled Fast Reactor

  • Chang, Seok-Kyu;Euh, Dong-Jin;Choi, Hae Seob;Kim, Hyungmo;Choi, Sun Rock;Lee, Hyeong-Yeon
    • Nuclear Engineering and Technology
    • /
    • v.48 no.2
    • /
    • pp.376-385
    • /
    • 2016
  • A hexagonally arrayed 37-pin wire-wrapped rod bundle has been chosen to provide the experimental data of the pressure loss and flow rate in subchannels for validating subchannel analysis codes for the sodium-cooled fast reactor core thermal/hydraulic design. The iso-kinetic sampling method has been adopted to measure the flow rate at subchannels, and newly designed sampling probes which preserve the flow area of subchannels have been devised. Experimental tests have been performed at 20-115% of the nominal flow rate and $60^{\circ}C$ (equivalent to Re ~ 37,100) at the inlet of the test rig. The pressure loss data in three measured subchannels were almost identical regardless of the subchannel locations. The flow rate at each type of subchannel was identified and the flow split factors were evaluated from the measured data. The predicted correlations and the computational fluid dynamics results agreed reasonably with the experimental data.

Comparison of Loss Coefficient using 1-inch Ball and Glove Valve Opening Ratio (1인치 볼 밸브 및 글로브 밸브에 대한 개도율에 따른 손실계수(k) 비교에 관한 연구)

  • Kang, Chang-Won;Yi, Chung-Seob;Lee, Chi-Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.9
    • /
    • pp.63-69
    • /
    • 2021
  • This study aims to determine the flow characteristics of a one-inch small ball valve and glove valve used in industrial plants. The flow was changed through an experimental equipment, and the internal flow characteristics of the valves were compared. Considering the pressure drop, the decrease in the slope of the ball valve based on the degree of the valve opening was relatively greater than that of the glove valve; further, the slope of the glove valve was gentle while the pressure drop was high. The flow velocity of the ball valve remains consistent after the valve was opened by 70%, whereas the flow velocity of the glove valve constantly increased. The valve loss factor of the ball valve was relatively low compared with that of the glove valve. When the valve was opened by 20%, which is the beginning stage of the valve opening, the valve loss factor of the ball valve was high and gradually became low. This is a structural problem of the ball valve, and the loss factor is significant because the flow path installed at the ball valve has a considerably small area. However, the overall loss factor of glove valve is high because it has a complicated structure of flow path.

Numerical Study of Channel Area Effects on the Performance Characteristics of Regenerative Type Fuel Pump (재생형 연료펌프의 채널 면적 변화가 성능 특성에 미치는 영향에 대한 수치해석적 연구)

  • Lee, Kyoung-Yong;Choi, Young-Seok;Son, Kwang-Eun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.5
    • /
    • pp.41-45
    • /
    • 2007
  • The effects of channel area on the performance of regenerative type fuel pump were numerically studied by commercial CFD code (ANSYS CFX-10). To examine the effects of channel area, the shapes of the side channel and blade were simplified. The channel area affected the flow characteristics of the internal recirculation flow between the side channel and the blade groove and also made a difference in the overall performance. These loss mechanism with circulation flow were adopted as a loss coefficient in the performance prediction program. The loss coefficient was newly derived from the results of calculations with different channel area, and compared with the experimental results in the reference paper and used to modify the performance prediction program. The circulation flow characteristics with different channel area, which is related with loss mechanism, were also discussed with the results of 3-dimensional flow calculations.