• Title/Summary/Keyword: flow duration

Search Result 701, Processing Time 0.035 seconds

Assessing Impact of Reduction of Non-Point Source Pollution by BASINS/HSPF (HSPF를 이용한 비점오염원 삭감에 따른 효과 분석)

  • Bae, Dae-Hye;Ha, Sung-Ryong
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.1
    • /
    • pp.71-78
    • /
    • 2011
  • This paper aims to assessing impact of reduction of non-point source pollution in the Bokha Stream watershed. The BASINS/HSPF model was calibrated and verified for water flow and water qualities using Total Maximum Daily Load 8days data from 2006 to 2007. Accuracy of the BASINS/HSPF models in simulating hydrology and water quality was compared and there were somewhat differences of statistical results, but water flow and water quality were simulated in good conditions over the study period. The applicability of models was tested to evaluate non-point source control scenarios to response hydrology and water quality in the Bokha stream using various measures which include BMPs approach and change of landuse. The evaluation of reduction of non-point source pollution was developed using load-duration curve. Despite strong reduction of non-point source, there are not satiated target quality at low flow season.

A sintering Behavior of Glass/Ceramic Composite used as substrate in High Frequency Range (고주파대역에서 기판으로 쓰이는 Glass/Ceramics Composite의 소결거동)

  • 이찬주;김형준;최성철
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.4
    • /
    • pp.302-307
    • /
    • 2000
  • The objective of this study was to investigate the sintering behavior, crystallization characteristic of glass-ceramic and optimal sintering condition on the glass/ceramic composite for fabricating substrate of LTCC. Glass/ceramic composite was made from alumina powder and glass frit, which was composed of SiO2-TiO2-RO-PbO/(R: Ba, Sr, Ca), and was sintered for 0, 30, 60minutes in the temperature range from 700$^{\circ}C$ to 1000$^{\circ}C$. Properties of frit and glass/ceramic compsoite were analyzed by DTA, XRD, SEM and Network Analyzer and so on. Main sintering mechanism was densification occurred above 730$^{\circ}C$ by viscous flow and crystallization starting about 780$^{\circ}C$ affected sintering also. So viscous flow was affected by sintering temperature, duration time, and creation of crystallization phase etc. From this study, it was possible to fabricate glass/ceramic composite by changing sintering temperature and duration time.

  • PDF

PREDICTION OF COMBINED SEWER OVERFLOWS CHARACTERIZED BY RUNOFF

  • Seo, Jeong-Mi;Cho, Yong-Kyun;Yu, Myong-Jin;Ahn, Seoung-Koo;Kim, Hyun-Ook
    • Environmental Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.62-70
    • /
    • 2005
  • Pollution loading of Combined Sewer Overflows (CSOs) is frequently over the capacity of a wastewater treatment plant (WWTP) receiving the water. The objectives of this study are to investigate water quality of CSOs in Anmyun-ueup, Tean province and to apply Storm Water Management Model to predict flow rate and water quality of the CSOs. The capacity of a local WWTP was also estimated according to rainfall duration and intensity. Eleven water quality parameters were analyzed to characterize overflows. SWMM model was applied to predict the flow rate and pollutant load of CSOs during rain event. Overall, profile of the flow and pollutant load predicted by the model well followed the observed data. Based on model prediction and observed data, CSOs frequently occurs in the study area, even with light precipitation or short rainfall duration. Model analysis also indicated that the local WWTP’s capacity was short to cover the CSOs.

Size Determination Method of Bio-Retention Cells for Mimicking Natural Flow Duration Curves (자연상태 유황곡선 보전을 위한 생태저류지 용량결정방법)

  • Lee, Okjeong;Jang, Suhyung;Kim, Hongtae;Kim, Sangdan
    • Journal of Wetlands Research
    • /
    • v.18 no.4
    • /
    • pp.424-431
    • /
    • 2016
  • LID facilities like bio-retention cells is applied to manage stormwater. LID concept becomes an important part in stormwater management, and the clear understanding of hydrologic performance and hydrologic impact on the corresponding catchment has been needed. In this study, the application of flow duration curves as design strategy is investigated. Bio-retention cells like many LID facilities are installed to reproduce natural hydrologic processes. In this study, the attempt to determine the size of a bio-retention cell is carried out to satisfy the flow duration criteria. From the results, it is shown that "5 mm * the area of a target catchment" which is the current facility design capacity is valid for the drainage area with 20-30% impervious rate. In the 100% impervious catchment where LID facilities are typically installed, the design capacity to intercept stormwater of approximately 47 mm depth is required to reproduce natural flow duration curves. This means that about 11% of the target catchment area should be allocated as a bio-retention cell. However, the criteria of the design capacity and facility surface area should be set at the possible implementation conditions in reality, and site-specific hydrologic characteristics of a target catchment should be considered.

Study of the Lower Duration Curve Characteristic by Reservoir and Weir Couple-operating System in Geum River Basin (금강수계 댐과 보의 운영에 의한 하류 유황특성 연구)

  • Ahn, Jung-Min;Cha, Kee-Uk;Ryoo, Kyong-Sik;Lyu, Si-Wan
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.4
    • /
    • pp.285-293
    • /
    • 2011
  • This study presents effects of downstream control point by coupled operation of dams and multi function weirs in the Geum River. Geum river basin that study area did authoritativeness high quality data to acquisition possibility. We applied the flow duration curve, flow regime coefficient, impounded flow index analysis to investigate the quantitative changes in natural flow regimes. In sphere that water supply is possible, this study applied believability that satisfy 95% at estimation year. Impounded flow index was calculated 0.292 by dam coupled operation and 0.297 by dam-weir coupled operation. The results indicate that the storage amount is increased by 29.7% as being added. Duration flow of downstream control point was improved because became coupled operation by regulation of dam and weir in the geum river.

Gas flow pattern through a long round tube of a gas fueling system (I) (기체연료주입계의 긴 원형도관에서 기체 흐름의 유형)

  • IN, S.R.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.5
    • /
    • pp.465-474
    • /
    • 2006
  • A gas fueling system composed of a gas reservoir, an on-off valve, and a gas transferring tube, which is the simplest construction for the pre-programmed gas puffing, was simulated by numerically solving the time-dependent one-dimensional gas flow equation. The purpose of the simulation is to establish the relationship between the gas flow pattern (the elapsed time to the maximum flow, the maximum flow rate, the gas pulse duration) and the system parameters (the filling pressure and the volume of the gas reservoir, and the length and the diameter of the gas transferring tube).

Applicability of Load Duration Curve to Nakdong River Wateished Management (낙동강 유역관리를 위한 부하량 유황곡선의 적용 가능성)

  • Han, Suhee;Shin, Hyun Suk;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.620-627
    • /
    • 2007
  • In this study a general analysis method for watersheds with the entire runoff conditions and corresponding water quality is proposed and its applicability based on the currently available information is investigated. Using the 8-day-interval data set of runoff and water quality observed by Nakdong River Environment Research Center, the flow duration curve and discharge-load relation curve for each unit watershed are established, then the load duration curve is finally constructed. This paper discusses how the load duration curve can be used in the assessment of TMDL. The entire Nakdong river watershed is also divided into prior managing areas of point sources or non-point sources in a way of general management. It is thought that LDC can be a great tool for visualizing overall probabilities of current water quality and thus for the TMDL management.

Development of Regional Regression Model for Estimating Flow Duration Curves in Ungauged Basins (미계측 유역의 유황곡선 산정을 위한 지역회귀모형의 개발)

  • Lee, Tae Hee;Lee, Min Ho;Yi, Jaeeung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.3
    • /
    • pp.427-437
    • /
    • 2016
  • The objective of this study is to develop the regional regression models based on the physiographical and climatological characteristics for estimating flow duration curve (FDC) in ungauged bsisns. To this end, the lower sections with duration from 185 to 355 days of FDCs were constructed from the 16 gauged streamflow data, which were fitted to the two-parameter logarithmic type regression equation. Then, the parameters of the equation were regionalized using the basin characteristics such as basin area, basin slope, drainage density, mean annual precipitation, mean annual streamflow, runoff curve number in order that the proposed regression model can be used for ungauged basin. From the comparison of the estimated by the regional regression model with the observed ones, the model with the combination of basin area, runoff curve number, mean annual precipitation showed the best performance.

Estimating BOD, CDO and TOC Hydrologic Flux in Nakdong River Basin (낙동강 유역 BOD, COD 및 TOC의 수문학적 플럭스 추정)

  • Lee, A-Yeon;Park, Moo-Jong;Jo, Deok-Jun;Kim, Sang-Dan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.9
    • /
    • pp.830-839
    • /
    • 2010
  • This study presents a constituent load estimating procedure that can be operated with the present Korean TMDL monitoring system. The modified TANK model is used as a daily river flow simulation model whose parameters are estimated from 8-day intervals flow data. Constituent loads are estimated with the 7-parameter log linear model whose parameters are estimated by the minimum variance unbiased estimator. Results from Nakdong river basin reveals that the proposed procedure provides satisfactory TOC and BOD load estimates. As an application, a representative load duration curve is derived for working out a way to represent the overall hydrologic flux of BOD, COD and TOC at Nakdong river basin. The present water quality can be checked stochastically by Load Duration Curve through this study and presented visually.

A Comparison Study on Fire Water Supply Duration and Capacity of Water Based Fire Suppression System of the United States, Japan, China and Korea (우리나라, 중국, 일본, 미국 수계소화설비 소화수 공급시간 및 소화수원에 대한 비교 연구)

  • Min, Se-Hong;Nam, Yu-Hyun
    • Fire Science and Engineering
    • /
    • v.27 no.4
    • /
    • pp.13-20
    • /
    • 2013
  • Buildings in Korea have been getting higher recently and been being changed environmentally since the Korean fire standard was released in 1968. It should be established to make a appropriate correspondence of fire fighting against the those environmental changes. Most of all, fire water capacity which is basis of fire fighting service is a very significant factor. In this paper, the Korean fire water capacity and fire water duration were compared with China, Japan and the United states. Furthermore, fire water capacity, fire water duration, flow rate were compared by hazard classification, occupant use, number of floor and area with water based fire suppression system. This study has been surveyed to show what are difference, similarity, advantage and disadvantage on fire water capacity in the Korean standard comparing with neighboring countries like China, Japan as well as the United states. This study could be found what level the Korean fire water capacity is. So it suggests about more developed standard on fire water capacity with the result of analysis and comparison.