• 제목/요약/키워드: flow control device

검색결과 408건 처리시간 0.029초

Baxter $Infusor^{(R)}$를 이용한 부인과 수술후의 통증 자가 조절 (Patient-Controlled Analgesia(PCA) for Pain Management after Gynecological Surgery)

  • 이정구;김진모;정정길
    • The Korean Journal of Pain
    • /
    • 제6권1호
    • /
    • pp.49-54
    • /
    • 1993
  • The use of intravenous patient-controlled analgesia is an effective and increasingly used means of providing postoperative pain relief. Recently a non-electric, disposable and portable infusor, the Baxter $Infusor^{(R)}$, has developed. This delivers not only a continuous drug infusion but can also deliver extradoses of medication on demand. The present study examined the benefits of two kinds of analgesics for pain management in 28 patients undergoing gynecological surgery. One group, 14 patients, received i.v. meperidine 0.5 mg/kg as loading dose in the recovery room and PCA with meperidine 3 mg/kg/day for 3 days only(M group). In the other group, 14 patients, also received i.v. meperidine 0.5 mg/kg as loading dose in the recovery room and PCA meperidine 3 mg/kg/day for 3 days and droperidol 5 mg(MD group). The PCA device used was the Baxter $Infusor^{(R)}$. This unit was fitted with patient control module which had a flow rate 0.5 ml/hr and the lockout time was 15 min. Resulting from the study, the MD patients in the first and second days post-operatively, reported less pain compared with the M group. VAPS(Visual Analogue Pain Scales) values were $3.52{\pm}l.61$ vs. $2.22{\pm}0.69$, $2.38{\pm}1.12$ vs. $1.45{\pm}0.48$ and $1.93{\pm}1.65$ vs. $0.98{\pm}0.36$, respectively pertaining to M and MD groups. In conclusion, the MD group with meperidine and droperidol(mixed regimen) provided more effective postoperative analgesia than M group(meperidine only).

  • PDF

횡단압력파 발생을 위한 단일 펄스건의 압력파 성능시험 (Performance Test of a Single Pulse Gun for Transverse Pressure Wave Generation)

  • 이종권;송우석;구자예
    • 한국항공우주학회지
    • /
    • 제47권8호
    • /
    • pp.599-606
    • /
    • 2019
  • 펄스건 장치는 연소실 내, 다중 분사기 배열에 따른 연소 유동장으로의 횡단 압력파 전파/감쇠 메커니즘 규명을 목적으로 제작되었다. 제작된 펄스건은 성능시험을 통해 목표 연소압에서의 운용 가능 여부와 압력파 강도 제어 여부를 확인하였다. 기체질소를 사용하여 고압관에 가압을 하였으며 다이아프램에는 $100{\mu}m$ 두께의 OHP 필름을 사용하였다. 압력파의 속도와 강도를 확인하기 위해 압력 트랜스듀서를 이용하여 동압과 정압을 측정하였다. 제작된 펄스건은 공급압력에 따라 압력파의 강도 조절이 가능하며 횡방향성을 가지는 압력파를 생성할 수 있음을 성능시험을 통해 확인하였다.

신재생에너지 활용 및 저장기능을 이용한 교육용 모의 태양광발전 가로등 설계 (Design of Simulated Photovoltaic Power Streetlight for Education using Renewable Energy Utilization and Storage Function)

  • 윤용호
    • 한국인터넷방송통신학회논문지
    • /
    • 제21권2호
    • /
    • pp.137-142
    • /
    • 2021
  • 태양광발전 가로등은 태양광에너지를 사용하여 2차전지에 충전 후 램프를 통해 야간조명에 활용하는 시스템으로서 부하 단 LED 가로등을 설치하여 독립형 또는 계통연계형으로 구성할 수 있다. 태양전지모듈을 통해 발전된 에너지는 충방전 제어장치를 통해 2차전지에 충전 후 일사량 감시에 따른 발전전압과 충전전압의 비교, 또는 일몰, 일출 후 특정시간 설정으로 LED 가로등을 점등 소등을 할 수 있다. 따라서 이러한 내용을 기반으로 본 논문에서는 신재생에너지 활용 및 저장기능을 이용한 교육용 모의 태양광발전 가로등 설계 및 제작을 통해 대학의 학생들에게 1) 태양광을 포함한 신재생에너지를 이용하여 전기에너지로 활용하는 에너지 변화의 흐름 이해, 2) 신재생에너지 이해 및 관련 제품의 기초설계와 제작 응용력 함양, 3) 전력변환을 통한 신재생에너지 활용과 하드웨어 제작을 통한 실습과 분석력 강화를 심어줄 수 있다.

주변 온도보상이 필요 없는 열선식 풍속 센서 시스템 (Hot Wire Wind Speed Sensor System Without Ambient Temperature Compensation)

  • 성준규;이근우;정회경
    • 한국정보통신학회논문지
    • /
    • 제23권10호
    • /
    • pp.1188-1194
    • /
    • 2019
  • 유체의 흐름을 측정하는 여러 방법 중 열선 풍속 센서는 유체의 열전달에 의해 속도나 온도를 측정하는 장치로 비정상 속도 및 난류 속도 성분을 측정하는데 유용하다. 하지만 열선 풍속 센서는 외부의 환경 요인에 민감하며, 주변 온도, 습도, 신호 잡음 등에 의해 정확도가 떨어지는 단점이 있다. 이런 단점을 보완하는 방법으로 온도 보상 회로를 추가하는 기술이 나오고 있지만 가격 경쟁력을 갖출 수 없는 상황이다. 이를 해결하기 위해 본 논문에서는 온도 보상이 필요 없는 풍속 감지 센서에 대해 연구를 진행하였다. 열선식 풍속 센서는 외부 환경 요인 중에서도 주변 온도에 매우 취약하다. 주변 온도로는 전자 회로에 의한 발열의 영향이 가장 크게 미치고 있으며, 이를 개선하는 방법으로 발열체에 보조 발열체를 추가로 장착하여 보조발열체와 발열체의 일정한 온도차를 제어하는 것이다. 이와 같이 기존 기술에 비해 복잡하지 않은 방법으로 동등한 성능을 확보할 수 있다는 것을 확인할 수 있었다.

설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

공기조화, 냉동 분야의 최근 연구 동향: 2006년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006)

  • 한화택;신동신;최창호;이대영;김서영;권용일
    • 설비공학논문집
    • /
    • 제20권6호
    • /
    • pp.427-446
    • /
    • 2008
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006 has been accomplished. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro heat exchanger and siphon cooling device using nano-fluid. Traditional CFD and flow visualization methods were still popular and widely used in research and development. Studies about diffusers and compressors were performed in fluid machinery. Characteristics of flow and heat transfer and piping optimization were studied in piping systems. (2) The papers on heat transfer have been categorized into heat transfer characteristics, heat exchangers, heat pipes, and two-phase heat transfer. The topics on heat transfer characteristics in general include thermal transport in a cryo-chamber, a LCD panel, a dryer, and heat generating electronics. Heat exchangers investigated include pin-tube type, plate type, ventilation air-to-air type, and heat transfer enhancing tubes. The research on a reversible loop heat pipe, the influence of NCG charging mass on heat transport capacity, and the chilling start-up characteristics in a heat pipe were reported. In two-phase heat transfer area, the studies on frost growth, ice slurry formation and liquid spray cooling were presented. The studies on the boiling of R-290 and the application of carbon nanotubes to enhance boiling were noticeable in this research area. (3) Many studies on refrigeration and air conditioning systems were presented on the practical issues of the performance and reliability enhancement. The air conditioning system with multi indoor units caught attention in several research works. The issues on the refrigerant charge and the control algorithm were treated. The systems with alternative refrigerants were also studied. Carbon dioxide, hydrocarbons and their mixtures were considered and the heat transfer correlations were proposed. (4) Due to high oil prices, energy consumption have been attentioned in mechanical building systems. Research works have been reviewed in this field by grouping into the research on heat and cold sources, air conditioning and cleaning research, ventilation and fire research including tunnel ventilation, and piping system research. The papers involve the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies on indoor air quality took a great portion in the field of building environments. Various other subjects such as indoor thermal comfort were also investigated through computer simulation, case study, and field experiment. Studies on energy include not only optimization study and economic analysis of building equipments but also usability of renewable energy in geothermal and solar systems.

정치식 원적외선 건조기를 이용한 수수×수단그라스 교잡종의 건초 조제 기술 연구 (Hay Preparation Technology for Sorghum×Sudangrass Hybrid Using a Stationary Far-Infrared Dryer)

  • 김종근;김현래;이원진;유영상;이연분;왕리리
    • 한국초지조사료학회지
    • /
    • 제43권1호
    • /
    • pp.22-27
    • /
    • 2023
  • 본 시험은 원적외선을 이용한 수수×수단그라스 교잡종 인공건초의 조제 가능성을 확인하기 위해 수행되었다. 본 시험에 사용된 기계는 원적외선을 기본으로 하는 건조 장치로 온도, 송풍량, 원적외선 방사량 및 기류 속도를 조절할 수 있도록 설계되었다. 9월 하순에 수확한 수수×수단그라스 교잡종을 1일간 포장에서 예건을 하였고 이를 대상으로 실시 건조 시험을 수행하였다. 건조를 위한 조건은 전체 7개의 조건을 선택하여 수행하였으며 각각의 조건은 단일 조건(방사율 42%) 및 2단계(4처리) 및 3단계(2처리) 방사율 변화를 유도하였다. 기기내의 기류의 속도는 60m/s로 고정하였고 건조시간은 30, 60 및 90분으로 변화를 주었다. 평균 건물함량은 82.84%로 나타났으며 1번 및 3번 건조조건에서는 수분함량이 각각 59.94 및 76.91%로 나타나 건초에는 적합하지 않았다. 건조율에 있어서는 5번, 6번 및 7번 처리구에서 80% 이상으로 유의적으로 높게 나타났으며 전력 소비량은 평균 5.7kw/h로 다소 높게 나타났다. 각각의 건조 조건에 따른 사료가치는 조단백질 함량은 건조시간이 길어질수록 높게 나타났으며 ADF, NDF, IVDMD 및 TDN 함량에 있어서는 처리간에 유의적인 차이를 보이지 않았다. RFV에 있어서는 단일 조건인 1번 처리구가 복합조건보다 유의적으로 낮게 나타났다. 이상의 결과를 통하여 건조속도, 전력량, 품질 등을 고려할 때 4번 및 5번 건조조건이 가장 유리한 것으로 판단되었다.

멀티미디어단말기용 상하대칭 루프 안테나 (Top and Bottom Symmetrical Loop Antenna for Multi-media Devices)

  • 신천우
    • 한국멀티미디어학회논문지
    • /
    • 제14권3호
    • /
    • pp.414-422
    • /
    • 2011
  • 본 연구는 얇은 유전체기판 위에 프린트 패턴으로 구현하는 상/하 대칭 루프안테나에 관한 것으로서, 유전체기판 상/하에 대칭으로 루프안테나용 동박패턴을 제작하여 기판의 상/하에 프린트된 루프패턴 간에서 방사되는 전자계가 서로 충돌하지 않게 방사되는 위상제어형 상/하 대칭 루프안테나에 관한 것이다. 이 방법으로 상/하에 프린트된 각 루프코일이 서로 동위상으로 보완적으로 배치되어 전자계가 원만하게 방사되어, 방사 손실이 없고 방사 효율이 뛰어나게 된다. 앓은 유전체기판의 상/하에 프린트하여 안테나를 구현함으로 연해 경박/소형화가 가능해지며, 이로 인하여 크기 $40mm{\times}6mm$ 이하의 사이즈에, 두께 0.2mm 이하의 박막의 유전체가판에 제 3세대 휴대폰대역인 WCDMA 안테나를 구현하여 액티브 시험에서 평균게인 -3dBi 이상 방사효율 50~70% 정도의 안테나특성이 얻어졌으며, 상용되는 이동형 멀티미디어단말기에 부착하여 액티브 시험결과 평균게인 -4dBi, 송/수신 효율이 43% 얻어졌다.

유조선 선체 파공에 따른 원유 유출 유속의 CFD 연구 (A CFD Study of Oil Spill Velocity from Hole in the Hull of Oil Tanker)

  • 최두영;이정섭;백중철
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2018년도 학술발표회
    • /
    • pp.71-71
    • /
    • 2018
  • 해상 교통량 증가에 따라 선박 사고로 인한 대형 해양 오염사고가 많이 발생하고 있다. 유조선 충돌에 따른 선체 파공은 원유의 바다 유출을 야기하여 심각한 해양오염을 유발하므로 이러한 사고에 대해서 신속한 방재 대응력이 요구된다. 작은 파공은 목제 플러그를 인위적으로 삽입하여 봉쇄하는 것이 일반적이지만, 대형 파공의 경우 사람이 직접 봉쇄하기에는 어려워 기계적 봉쇄장치 개발이 요구된다. 파공봉쇄 장치 개발을 위해서는 유체의 유출유속을 정확하게 아는 것이 중요하다. 이 연구에서는 2007년 태안 기름유출 사고에서 관측된 초기수심 7.5 m, 직경 30 cm의 파공에 대해서 고해상도 CFD 모델링을 수행하여 수심별 기름 유출 유속의 분포를 계산하였다. 비중 0.85이며, 원유의 온도 $20^{\circ}C-100^{\circ}C$ 조건에 따른 점성계수 $4-12cP(mPa{\cdot}s)$ 조건에서 파공을 통한 원유 유출을 고해상도 모델링한다. 모델링 결과를 분석하여 원유유출에 대한 마찰손실계수와 유량계수의 범위를 레이놀즈수의 함수로 제시한다.

  • PDF

천식환자에서 Fluticasone propionate와 Beclomethasone dipropionate의 치료효과 비교 (Fluticasone Propionate and Beclomethasone Dipropionate in Asthmatic Patients)

  • 양동규;김영삼;안철민;고원기;장준;김성규;이원영
    • Tuberculosis and Respiratory Diseases
    • /
    • 제47권5호
    • /
    • pp.629-641
    • /
    • 1999
  • 연구배경: 스테로이드는 천식의 장기적인 치료에 사용하는 약물로 치료효과는 기도에 대한 항염증작용을 통해 이루어지는 것으로 알려져 있다. fluticasone propionate(FP)는 치료효과가 크고 주로 폐에 국소적으로 작용하는 약물로서 beclomethasone dipropionate(BDP)에 비해 2배 정도의 역가를 가지고 있다고 알려져 있다. 이 연구를 통해 FP와 BDP의 치료효과를 비교하고자 하였다. 방 법: 50명의 천식환자를 대상으로 하여 연구를 진행하였다. 환자에게 무작위적으로 FP 혹은 BDP를 4주 동안 투여하였다. 처음 2주간의 Run-in period에는 $\beta_2$-기관지확장제반을 투여하였고 그 후 무작위적으로 FP 또는 BDP를 투여하였다. FP는 diskhaler를 이용하여 하루 2 회 $250{\mu}g$씩 총 $500{\mu}g$을 투여하였고, BDP는 reservoir dry-power device-RPD 를 이용하여 하루 2회 $400{\mu}g$씩 총 $800{\mu}g$을 투여하였다. Run-in period 및 치료 기간 종에 매일 아침과 저녁의 최고호기유량과 주간과 야간의 천식증상점수, 주간과 야간의 응급 & 기관지확장제 사용횟수 등을 측정하였다. $FEV_{1.0}$과 FVC는 치료시작전과 치료 후 2주 간격으로 3 회 측정하였다. 결 과: FP를 투여한 환자 중 3 명과 BDP를 투여한 환자 중 7명이 탈락되어, 총 40명의 천식환자를 대상으로 결과를 분석하였다. FP 및 BDP 투여 후에 아침과 저녁의 최고호기유량이 유의하게 증가하고, 최고호기유량의 일중변이는 유의하게 감소하였다. 폐기능 검사 결과 $FEV_{1.0}$은 FP를 투여한 군에서 증가하고, FVC는 양 군에서 모두 증가하지 않았다. 주간 및 야간의 천식증상 점수가 호전되고, 응급 $\beta_2$-기관지확장제 사용횟수는 유의하게 감소하였다. 그러나 두 군 사이의 치료효과에는 유의한 차이가 없었다. 최고호기유량의 증가, 일중변이의 감소, 증상의 호전 및 응급 $\beta_2$-기관지확장제 사용횟수의 감소는 FP를 투여한 군에서 더 빨리 나타났다. 결 론: 천식환자에게 매일 FP $500{\mu}g$과 BDP $800{\mu}g$을 투여하였을 때, 두 군간의 치료효과는 유사하였다. 효과는 FP를 투여한 군에서 더 빨리 나타났고 부작용으로 치료를 중단한 경우는 없었다.

  • PDF