• 제목/요약/키워드: flow characteristics

검색결과 13,479건 처리시간 0.031초

OMACON형 LM-MHD 시스템에서의 에너지전환특성 시뮬레이션 (Simulation of Energy Conversion Characteristics of OMACON LM-MHD Systems)

  • 김창녕
    • 한국시뮬레이션학회논문지
    • /
    • 제6권2호
    • /
    • pp.1-14
    • /
    • 1997
  • The characteristics of the flow and energy conversion in OMACON liquid-metal MHD system are investigated. Numerical simulation of two-phase flow in the OMACON system without magnetic field was carried out by the Phoenics code and the energy conversion characteristics are studied in association with the fact that the mechanical energy loss at the nozzle of the OMACON system are to be converted into electrical energy. In this system, working fluid (gas) is injected through the mixer located at the bottom of the riser, and is mixed with hot liquid metal. Therefore in the riser two-phase flow is developed under the influence of the gravity. In this study, the interaction between the gas and liquid is considered by the use of IPSA(InterPhase Slip Algorithm) where standard drag coefficient has been used. It has been assumed that in the flow regime the liquid is continuous and the gas is dispersed. For the liquid and gas, the continuity equations, momentum equations and energy equations are solved respectively in association with void fraction in the flow field. In order to calculate the energy conversion efficiency, firstly the ratio of the mechanical energy loss of liquid metal flow at the nozzle to the input thermal energy is considered. Secondly flow pattern of liquid metal in the generator has been analyzed, and the characteristics of the conversion of the mechanical energy into the electrical energy has been investigated. For an representative case where Hartmann number is 540 and magnetic field is 0.35 T, the present analysis shows that the energy conversion efficiency is 0.653. This result is considered to be reasonable in comparison with published experimental results.

  • PDF

LDV에 의한 곡관 후류에 연결된 직관에서 난류맥동유동의 유동특성 (Flow Characteristics of a Turbulent Pulsating Flow in a Straight Duct Connected to a Curved Duct by using an LDV)

  • 손현철;이행남;박길문
    • 설비공학논문집
    • /
    • 제15권3호
    • /
    • pp.177-186
    • /
    • 2003
  • In the present study, the flow characteristics of developing turbulent flows are investigated at the exit region of a square cross-sectional 180" curved duct with dimensions of 40mm$\times$40mm$\times$4000mm (height $\times$ width $\times$length). Smoke particles produced from mosquito coils were used as seed particles for the LDV measurement. Experiments were carried out to measure axial velocity profiles, shear stress distributions and entrance lengths by using an LDV system and Rotating Machinery Resolver RMR with PHASE software. Experimental results clearly show that the time-averaged Reynolds number does not affect oscillatory flow characteristics because the turbulent components tend to balance the oscillatory components in the fully developed flow region. Also, the velocity profiles are in good agreement with 1/7power law such as the results of steady turbulent flows. The turbulent intensity linearly increases along the walls and is slightly higher, especially in the period of deceleration. On the other hand, the LDV measurements show that shear stress values in slightly higher in the period of deceleration due to the flow characteristics in the exit region. The entrance length where flows become stable appears at the point that is 40 times the length of hydraulic diameter.eter.

다중 필터 시스템의 유동특성 해석 (Analysis of Flow Characteristics of Multiple Filter System)

  • 손인수;서미영;김준호;유진석
    • 한국산업융합학회 논문집
    • /
    • 제26권4_2호
    • /
    • pp.615-621
    • /
    • 2023
  • In this study, flow analysis of single, double, and triple filter systems of cylindrical structures was performed to analyze the flow characteristics of each filter. As a result of the flow analysis of the filter system, the number of filters and the pressure drop rate tend to be proportional to each other. It was found that the area passing through the inside of the filter had almost the same pressure. The maximum pressure drop rate of the triple filter system was about 14.9% for the forward-flow and about 12.4% for the reverse-flow. It was determined that the performance of the filter was stable within 20% of the allowable pressure drop rate of the filter system, which is the standard presented to the Korea Water Technology Certification Institute(KWTCI). In the future, a study on the decompression characteristics of the filter system according to the effect of the arrangement interval and filter density of the triple filter will be conducted.

초음속 유동장 내 이중 수직분사의 특성에 관한 연구 I-혼합특성 (Characteristics of Dual Transverse Injection in Supersonic Flow Fields I-Mixing Characteristics)

  • 신훈범;이상현
    • 한국항공우주학회지
    • /
    • 제30권6호
    • /
    • pp.53-60
    • /
    • 2002
  • 단일 분사 노즐을 갖는 연소기 내부의 혼합과정에 대한 이해를 바탕으로 연료 분사 노즐을 이중으로 갖는 연소기의 혼합과정에 대한 수치연구를 수행하였다. 수치연구를 위하여 3차원 Navier-Stokes 방정식과 k-$\omega$ SST난류 모델을 이용하여 연료 이중 분사 유동을 모사하였다. 이중 분사구 사이의 거리 변화에 따른 혼합특성의 변화를 살펴보기 위하여 파라메터 연구를 수행하였다. 연료 이중 수직분사에서 두 분사기의 유동 및 혼합특성은 서로 상당히 다른 경향을 보이며, 후방 분사기의 유동 및 혼합특성은 전방 분사류의 영향을 받아 더 크게 팽창하고 침투거리가 증가하는 것으로 나타났다. 어떤 특정 거리가 되기 전까지 분사기 사이의 거리가 증가할수록 전체적인 혼합률과 침투거리가 증가하는 등 혼합특성이 개선되지만, 특정 거리보다 크게되면 오히려 혼합특성이 악화되는 것으로 나타났다. 이는 이중분사기에서 최적인 혼합특성을 위한 두 분사기 사이의 거리가 존재함을 의미하는 것으로 판단된다.

벼 상온통풍건조시설의 송풍특성 (Airflow Characteristics of Natural Air Drying for Rough Rice)

  • 이효재;김훈;한재웅
    • 한국지역사회생활과학회지
    • /
    • 제24권3호
    • /
    • pp.391-397
    • /
    • 2013
  • This study was conducted to define the characteristics of the fan according to the bed depth of rough rice for the silo used in South Korea. In this study, the characteristics like air flow resistance and air flow rate of the fan were investigated for an independent blowing system with 1 fan and the serial blowing system with 2 fans. In the experiment, the depth of rough rice was determined by 0, 1, 2, 3.2 and 4.5 m for an independent blowing system and the depth of rough rice was 4.5 m for the serial blowing system. The air flow resistances of the blowing fan and the suction fan in an independent blowing system were 55 mmAq and 88 mmAq respectively. In addition, the air flow resistance of the serial blowing system was 61% lower than the blowing fan and 28% lower than the suction fan of the independent blowing system. The air flow rates of the blowing fan and the suction fan in the serial blowing system were 516 $m^3/min$, 570 $m^3/min$, respectively. The former was 22% higher than the blowing fan while the latter was 29% higher than the suction fan in the independence blowing system. In other words, the serial blowing system was superior to the independent blowing system in blowing characteristics because the air flow rate was lower and air flow resistance was higher than the independent blowing system. However, the fan power consumption of the serial blowing system was more than 100% comparing with the independent blowing system.

사행하천에서의 흐름특성 비교에 관한 연구 (A Study of Flow Characteristics in Meandering River)

  • 손아롱;류종현;한건연
    • 한국방재학회 논문집
    • /
    • 제11권3호
    • /
    • pp.191-200
    • /
    • 2011
  • 제방의 붕괴로 인하여 인명 및 재산상의 막대한 피해가 발생한다. 제방의 붕괴는 월류 및 침식에 의한 붕괴가 대부분을 차지하고 있으나 이에 대한 분석이 제대로 이루어지지 않고 있다. 사행하천에서의 흐름특성은 하천제방과 관련하여 실용적인 관점에서 연구하여야 하는 하천 수리학에서는 중요한 주제이다. 사행하천에서는 회전방향이 교호적으로 바뀌는 나선형의 흐름(2차류)이 3차원적으로 발생하는 것으로 알려져 있다.. 이에 본 연구에서는 2차원 CCHE2D모형과 3차원 FLOW3D모형을 이용하여 하천 만곡부에서의 흐름특성을 분석하고자 하였다. 가상 하도에 대하여 수리모형 실험의 실측치와 비교하여 모형의 정확성과 안정성을 검증하였다. 그리고 모형의 적용성 검토를 위해 남강댐 하류에 대하여 만곡부의 흐름특성(유속분포 및 최대유속경로, 수위분포, 2차류 거동, 편수위, 전단응력 분포 등)을 분석하였다. 그 결과 하천 만곡부에서의 수리적 특성을 보다 정확하게 제시할 수 있었으며 하천의 제방 안정성 평가시 사행하천에 관한 수리적 특성을 효율적으로 활용하고자 한다.

협착부가 존재하는 혈관의 유동 특성에 관한 수치 해석적 연구 (A Numerical Analysis on the Hemodynamic Characteristics in the blood vessel with Stenosis)

  • 정훈;박찬국
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1987-1992
    • /
    • 2004
  • Hemodynamics behavior of the blood flow is influenced by the presence of the arterial stenosis. If stenosis is present in an artery, normal blood flow is disturbed. In the present study, characteristics of steady and pulsatile flow of non-Newtonian fluid, the effects of stenosised geometry are analyzed by numerical simulation. One interesting point is that non-symmetric solutions were obtained at severity stenosis, although the stenosis and the boundary condition were all axisymmetric.

  • PDF

모서리 형상에 따른 수직벽 후류특성에 관한 연구 (A Study on Wake Flow Characteristics of vertical Plate with Various Coner Shape)

  • 이철재;조대환
    • 한국기계기술학회지
    • /
    • 제13권2호
    • /
    • pp.101-106
    • /
    • 2011
  • In this study, the velocity distribution according to upper side coner shape of underwater construction with rectangular cylinder was measured with PIV method and the wake flow characteristics was considered. According to the coner shape, the flow pattern of wake flow was also differed greatly and the step-shaped coner of cut-off ratio B/H=0.06 was similar in the slope shape in result.

교환기실의 급배기방식에 따른 통신 시스템의 냉각 특성 (Cooling characteristics of the telecommunication system in a switching room for various air supply and return flow system)

  • 노홍구;이재헌;고철균
    • 설비공학논문집
    • /
    • 제11권5호
    • /
    • pp.669-683
    • /
    • 1999
  • Heat dissipation in the domestic switching room has been gradually increased. Therefore, numerical study on the cooling characteristics of the telecommunication system in a switching room for three kinds of the air supply and return flow system was investigated to develop effective flow system. As a result, the cooling performance of the under floor air supply and overhead return flow system was the best.

  • PDF

Supersonic Moist Air Flow with Condensation in a Wavy Wall Channel

  • Ahn, Hyung-Joon;Kwon, Soon-Bum
    • Journal of Mechanical Science and Technology
    • /
    • 제15권4호
    • /
    • pp.492-499
    • /
    • 2001
  • The characteristics of Prand시-Meyer expansion of supersonic flow with condensation along a wavy wall in a channel are investigated by means of experiments and numerical analyses. Experiments are carried out for the case of moist air flow in an intermittent indraft supersonic wind tunnel. The flow fields are visualized by a Schlieren system and the distributions of static pressure along the upper wavy wall are measured by a scanning valve system with pressure transducers. In numerical analyses, the distributions of streamlines, Mach lines, iso-pressure lines, and iso-mass fractions of liquid are obtained by the two-dimensional direct marching method of characteristics. The effects of stagnation temperature, absolute humidity, and attack angle of the upper wavy wall on the generation and the locations of generation and reflection of an oblique shock wave are clarified. Futhermore, it is confirmed that the wavy wall plays an important role in the generation of an oblique shock wave and that the effect of condensation on the flow fields is apparent.

  • PDF