• 제목/요약/키워드: flow blockage

검색결과 194건 처리시간 0.024초

비틀림 유도파를 이용한 배관 내부 슬러지검출 (Sludge Detection Inside Pipes Using Torsional Guided Waves)

  • 박경조;김정엽
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.757-762
    • /
    • 2013
  • A technique is presented that uses a new guided wave technique for sludge and blockages detection in long-range pipelines. Existing techniques have the limitations that the sludge position needs to be known a priori and the area to be inspected needs to be accessible. Two guided wave techniques have been developed which allow the sludge or blockages to be detected remotely without the need to access the specific location where the pipe is blocked, nor to open the pipe. The first technique measures the reflection of guided waves by sludge which can be used to accurately locate the blocked region; the second technique detects sludge by revealing the changes to the transmitted guided waves propagating in the blocked region or after it. The two techniques complement each other and their combination leads to a reliable sludge or blockage detection. Various types of realistic sludge have been considered in the study and the practical capabilities of the two techniques have been demonstrated.

  • PDF

Changes of Blood Flow Characteristics due to Catheter Obstruction during the Coronary Angioplasty

  • Suh, Sang-Ho;Roh, Hyung-Woon;Kwon, Hyuck-Moon;Lee, Byoung-Kwon
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제2권1호
    • /
    • pp.25-30
    • /
    • 2004
  • Catheters are used to measure translesional pressure gradients in the stenosed coronary arteries. Uses of catheters during coronary angioplasty cause flow obstructions. A narrowed flow cross section with catheter effectively introduced a tighter stenosis than the enlarged residual stenoses after balloon angiplasty. Catheters in blood vessels cause pressure gradient rise and blood flow drop during the measurements. In this study, three dimensional computer simulations are conducted to investigate the flow blockage effects due to the catheter obstructions during the coronary angioplasty. The computer simulation models are generated by the data, which are measured by coronary angiogram, and the blood is treated as non-Newtonian fluid. The velocity, pressure, and wall shear stress variations are observed for the estimate of damages of blood vessel. This study is also extended to investigate the effects of stenotic vessel size, and shape and catheter size and location.

  • PDF

Numerical investigation on the hydraulic loss correlation of ring-type spacer grids

  • Ryu, Kyung Ha;Shin, Yong-Hoon;Cho, Jaehyun;Hur, Jungho;Lee, Tae Hyun;Park, Jong-Won;Park, Jaeyeong;Kang, Bosik
    • Nuclear Engineering and Technology
    • /
    • 제54권3호
    • /
    • pp.860-866
    • /
    • 2022
  • An accurate prediction of the pressure drop along the flow paths is crucial in the design of advanced passive systems cooled by heavy liquid metal coolants. To date, a generic pressure drop correlation over spacer grids by Rehme has been applied extensively, which was obtained from substantial experimental data with multiple types of components. However, a few experimental studies have reported that the correlation may give large discrepancies. To provide a more reliable correlation for ring-type spacer grids, the current numerical study aims at figuring out the most critical factor among four hypothetical parameters, namely the flow area blockage ratio, number of fuel rods, type of fluid, and thickness of the spacer grid in the flow direction. Through a set of computational fluid dynamics simulations, we observed that the flow area blockage ratio dominantly influences the pressure loss characteristics, and thus its dependence should be more emphasized, whereas the other parameters have little impact. Hence, we suggest a new correlation for the drag coefficient as CB = Cν,m2.7, where Cν,m is formulated by a nonlinear fit of simulation data such that Cν,m = -11.33 ln(0.02 ln(Reb)).

편심협착부가 있는 관상동맥내 카테터삽입에 따른 혈액유동특성 (Blood Flow Characteristics due to Catheter Insertion in the Eccentric Stenosed Coronary Artery)

  • 노형운;서상호;권혁문;이병권
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.707-708
    • /
    • 2002
  • Catheters are used to measure translesional pressure gradients in the stenosed coronary arteries. Catheter insertions during coronary angioplasty cause flow obstructions. A narrowed flow cross section with catheter present effectively introduced a tighter stenosis than the enlarged residual stenoses after balloon angiplasty. In general, the form of stenoses are no uniform. Sometimes, these are occurred the irregularly eccentricity If the analyses are conducted for uniform stenosed artery, the results will be underestimated. Thus, in this study, three dimensional computer simulations are conducted to investigate the flow blockage effects due to the catheter insertion during the coronary angioplasty. The results for the eccentric stenosed artery are compared with those of the concentric stenosed artery.

  • PDF

원심압축기 채널디퓨저 내부의 압력분포에 관한 연구 (A Study on Pressure Distributions in a Centrifugal Compressor Channel Diffuser)

  • 강정식;강신형
    • 대한기계학회논문집B
    • /
    • 제25권4호
    • /
    • pp.507-513
    • /
    • 2001
  • Time averaged pressure distributions in a high-speed centrifugal compressor channel diffuser at design and off-design flow rates are investigated. Pressure distributions from the impeller exit to the channel diffuser exit are measured for various flow rates from choke to near surge condition, and the effects of operating condition are discussed. The strong non-uniformity in the pressure distribution is obtained over the vaneless space and semi-vaneless space caused by the impeller-diffuser interaction. As the flow rate increases, flow separation near the throat, due to large incidence angle at the vane leading edge, increases aerodynamic blockage and reduces the aerodynamic flow area downstream. Thus the minimum pressure location occurs downstream of the geometric throat, and it is named as the aerodynamic throat. And at choke condition, normal shock occurs downstream of this aerodynamic throat. The variation in the location of the aerodynamic throat is discussed.

설계 및 탈설계점에서의 원심압축기 채널디퓨저 내부의 압력분포에 관한 연구 (A Study on the Pressure Distribution in the Centrifugal Compressor Channel Diffuser at Design and Off-Design Conditions)

  • 강정식;강신형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.548-554
    • /
    • 2000
  • The aim of this paper is to understand the time averaged pressure distributions in a high-speed centrifugal compressor channel diffuser at design and off-design flow rates. Pressure distributions from the impeller exit to the channel diffuser exit are measured and discussed far various flow rates from choke to near surge condition, and the effect of operating condition is discussed. The strong non-uniformity in the pressure distribution is obtained over the vaneless space and semi-vaneless space caused by the impeller-diffuser interaction. As the flow rate increases, flow separation near the throat, due to large incidence angle at the vane leading edge, increases aerodynamic blockage and reduces the aerodynamic flow area downstream. Thus the minimum pressure location occurs downstream of the geometric throat, and it is named as the aerodynamic throat. And at choke condition, normal shock occurs downstream of this aerodynamic throat. The variation in the location of the aerodynamic throat is discussed.

  • PDF

대와류를 이용한 채널 내 열전달 증진 (Effective Heat Transfer Using Large Scale Vortices)

  • 윤동혁;최춘범;이경준;양경수
    • 대한기계학회논문집B
    • /
    • 제32권3호
    • /
    • pp.198-206
    • /
    • 2008
  • A numerical study has been carried out to investigate heat transfer enhancement in channel flow using large-scale vortices. A square cylinder, inclined with respect to the main flow direction, is located at the center of the channel flow, generating a separation region and Karman vortices. Two cases are considered; one with a fixed blockage ratio and the other one with a fixed cylinder size. In both cases, the flow characteristics downstream of the cylinder significantly change depending on the inclination angle. As a result, heat transfer from channel wall is significantly enhanced due to increased vertical-velocity fluctuations induced by the large-scale vortices shed from the cylinder. Quantitative results as well as qualitative physical explanation are presented to justify the effectiveness of the inclined square cylinder as a vortex generator to enhance heat transfer from channel wall.

유량에 따른 축류홴의 익단누설와류 및 후류 특성 (Flow Characteristics of Wake Flow with Relation to a Tip Leakage Vortex at Different Flow Rates in an Axial Flow Fan)

  • 김광용;장춘만
    • 대한기계학회논문집B
    • /
    • 제29권3호
    • /
    • pp.322-329
    • /
    • 2005
  • The flow characteristics in the blade passage and in the wake region of a low speed axial flow fan have been investigated by experimental analysis using a rotating hot-wire sensor for design and off-design operating conditions. The results show that the tip leakage vortex is moved upstream when flow rate is decreased, thus disturbing the formation of wake flow near the rotor tip. The tip leakage vortex interfaces with blade pressure surface, and results in high velocity fluctuation near the pressure surface. From axial velocity distributions downstream of the fan rotor, large axial velocity decay near the rotor tip is observed at near stall condition, which results in large blockage compared to that at the design condition. Although the wake flow downstream of the rotor blade is clearly measured at all operating conditions, the trough of the high velocity fluctuation due to Karmann vortex street in the wake flow is mainly observed at a higher flow condition than the design flow rate.

디퓨저 베인각의 변화에 따른 압축기 성능 특성 (Compressor Performance with Variation of Diffuser Vane Angle)

  • 신유환;김광호;배명형;김진형
    • 한국유체기계학회 논문집
    • /
    • 제3권2호
    • /
    • pp.36-43
    • /
    • 2000
  • This study presents the centrifugal compressor performance for three different vane stagger angles and wall pressure distribution within vaned diffuser channels, and is also discussed about the stability with respect to the compressor components. As the vane stagger angle decreases, the flow rate for the stall onset decreases, and higher pressure can be obtained at the low flow rate region, however, the effective operation range of the compressor decreases because of the blockage effect of the diffuser vane. Low pressure pocket within the vaned diffuser channel moves from the pressure side of leading edge to the suction side as the flow rate decreases. The compressor system stability mainly depends on that of the diffuser.

  • PDF

Numerical Study of Important Factors for a Vortex Shedder using Automated Design Cycle

  • Nyein, Su Myat;Xu, He
    • International Journal of Fluid Machinery and Systems
    • /
    • 제8권3호
    • /
    • pp.124-131
    • /
    • 2015
  • The good performance of a vortex shedder is defined by strong and stable vortex generated under the condition of most linearity in Strouhal number and low power loss. In this paper, the flow past a bluff body of circular cylinder with a slit normal to the flow has been analyzed focusing on drag coefficient, linearity of Strouhal number and flow resistance (K-factor). The ANSYS/FLUENT package is used for flow simulation and the integration method of computational code to iSIGHT platform is employed for automated design cycle. This study results the design with (0.20~0.267) blockage ratio and 0.10 slit ratio as the best shedder for vortex flowmeter and this results are in well agreement with the experiment. As the combination of GAMBIT, FLUENT, and iSIGHT substitutes the design parameters automatically according to the input data, this method designs effectively the vortex shedder with less design cycle time and low manufacturing cost eliminating the human intervention bottleneck.