• 제목/요약/키워드: floors and floor covering

검색결과 7건 처리시간 0.023초

Floor Slipperiness Effect on the Biomechanical Study of Slips and Falls

  • Myung, Ro-Hae;Smith, James L.;Lee, Soon-Yo
    • 대한산업공학회지
    • /
    • 제22권3호
    • /
    • pp.337-349
    • /
    • 1996
  • A study was conducted to find the possible relationship between slip distance and dynamic coefficient of friction (DCOF) through the biomechanical study of slips and falls using a broader variety of floors and levels of slipperiness than those used before. Four different floor surfaces covering the full range of floor slipperiness (with and without on oil contaminant) were prepared for ten subjects with each walking at a fixed velocity. The results showed that slip distance and heel velocity had a decreasing trend while stride length had a increasing trend as DCOF increased. The contaminant effect overpowered floor slipperiness effect because a higher DCOF surface with oil contaminant created longer slip distance than the lower DCOF with dry floor. Normal gait pattern and suggested heel velocity (10 to 20 cm/sec) were seen on dry floors but abnormally longer stride length and 5 to 10 times faster heel velocity were found an oily floors. In other words, faster heel velocity (greater than 10 to 20 cm/sec) is recommended to measure DCOF on oily floors because the assumption of normal gait was no longer valid.

  • PDF

SL 무기질 바닥재의 경제성 분석에 관한 연구 (A study on the economic analysis of the SL(Self Leveling) Inorganic Floor covering)

  • 박호근;홍성욱;양재영;김상원;신찬호;최민권
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 2부
    • /
    • pp.105-109
    • /
    • 2011
  • This study is concerned with the development of the SL inorganic floor covering. First, volatile organic compounds, inorganic test profile on the SL through the flooring is environment-friendly inorganic noncombustible floor finishes the event of fire toxic gases (such as volatile organic compounds) emissions have been identified as not at all. Second, SL-breathable material, the concrete floor to prevent aging, long life, which are three levels of noise, shock-absorbing function was decreased. Third, SL economic analysis of mineral flooring terrazzo tile floors compared with the normal material. On a terrazzo tile cost 13,500 won ~ 24,500 won, but It have found that, in terms of labor SL 36,899 won ~ 38,899 won flooring mineral balance. Occurs in the total amount when compared with terrazzo tile floors and 25,399 won 3T, 5T and economical analysis concludes that the original 12,399 won.

  • PDF

Stress-transfer in concrete encased and filled tube square columns employed in top-down construction

  • Kim, Sun-Hee;Yom, Kyong-Soo;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • 제22권1호
    • /
    • pp.63-77
    • /
    • 2016
  • Top-down construction is a construction technique in which pit excavation and structure construction are conducted simultaneously. Reducing construction time and minimizing noise and vibration which affect neighboring structures, the technique is widely employed in constructing downtown structures. While H-steel columns have been commonly used as core columns, concrete filled steel tube (CFT) columns are at the center of attention because the latter have less axial directionality and greater cross-sectional efficiency than the former. When compared with circular CFT columns, square CFT columns are more easily connected to the floor structure and the area of percussion rotary drilling (PRD) is smaller. For this reason, square CFT columns are used as core columns of concrete encased and filled square (CET) columns in underground floors. However, studies on the structural behavior and concrete stress transfer of CET columns have not been conducted. Since concrete is cast according to construction sequence, checking the stress of concrete inside the core columns and the stress of covering concrete is essential. This paper presents the results of structural tests and analyses conducted to evaluate the usability and safety of CET columns in top-down construction where CFT columns are used as core columns. Parameters in the tests are loading condition, concrete strength and covering depth. The compressive load capacity and failure behavior of specimens are evaluated. In addition, 2 cases of field application of CET columns in underground floors are analyzed.

4종류의 구급장비 및 마루(Floor) 위에서 시행한 가슴압박 에너지(kg)측정 실험에 관한 연구 (Chest Compression Energy(kg) Measurement of 4 Types of Rescue Device on the Floor)

  • 신동민;한용택;김승용;박시은
    • 한국안전학회지
    • /
    • 제29권6호
    • /
    • pp.125-131
    • /
    • 2014
  • The purpose of this study is to investigate the effect of high quality CPR using the 4 types of rescue device equipment and chest compressions energy measurement in pre-hospital settings. So, we used the mode to insert load cell in ALS Skill master Manikin to develop CFMM(Compression Force Measurement Manikin) on main stretcher, CPR board, long spine board, scoop stretcher and floor. And, our research team could know that the main stretcher needed average force of 32.55 (${\pm}1.01$) kg, CPR board of 27.23 (${\pm}1.08$) kg, long spine board of 27.13 (${\pm}1.18$) kg, Scoop Stretcher of 27.38 (${\pm}1.05$) kg and Floor of 27.24 (${\pm}0.93$) kg. CPR board must be necessary in the case of CPR on main stretcher in a moving ambulance. But if the condition of patient's back surface is the removable stretcher and the long spine plate, the patient doesn't have to be spent time to use a CPR board. Furthermore, this research suggests to consider that how to take advantage of the education to students for the equipment to check in real time the energy(kg) requirement of chest compressions.

동절기 온실의 열 손실에 관한 실태조사 - 경남지역을 중심으로 - (Current on the Heat Loss in Greenhouses during Winter Season - Case Study Based on Gyeongnam Area -)

  • 임재운;윤성욱;김현태;윤용철
    • 생물환경조절학회지
    • /
    • 제22권1호
    • /
    • pp.73-79
    • /
    • 2013
  • 본 연구에서는 온실의 열손실을 최소화할 방안을 모색하기 위하여 경남지역에 있는 시설 농가를 대상으로 열화상 카메라를 이용하여 열손실 사례에 대한 실태조사를 실시하였다. 그 결과를 요약하면 다음과 같다. 치마처리 전 후의 두 실험구간의 온도차는 각각 $2.0{\sim}3.0^{\circ}C$$1.0{\sim}2.0^{\circ}C$ 정도인 것을 알 수 있다. 열화상 기기에 의해 계측된 온도와 온도 센서에 의해 계측된 온도와는 상관 관계가 큰 것으로 나타났다. 실태조사 지역 간에 큰 차이는 없었지만 보온용 부직포가 1층인 경우와 2층인 경우를 보면, 1층이 2층에 비해 상대적으로 열손실 크게 나타났다. 그리고 전체적으로 온실의 형태와 무관하게 측장부분과 수평보온커튼의 틈새, 측면과 전 후면 보온용 부직포의 이음부분이 완전히 밀폐되지 않아 열손실이 상대적으로 큰 것으로 나타났다. 특히, 파손된 피복재나 출입문, 환기구, 박공, 바닥부근 등에서 틈새가 생겨서 많은 양의 열이 손실되고 있었다.

태풍 재해에 대한 건물 취약성의 피해손실 데이터 기반 분석 (Analysis of Building Vulnerabilities to Typhoon Disaster Based on Damage Loss Data)

  • 안성진;김태희;손기영;김지명
    • 한국건축시공학회지
    • /
    • 제19권6호
    • /
    • pp.529-538
    • /
    • 2019
  • 태풍은 전 세계적으로 상당한 재정적 피해를 입힌다. 정부, 지방자치단체, 보험회사는 태풍 위험 평가 모델을 개발하여 자연 재해에 따른 재정 위험을 정량화하고 완화하고자 한다. 이에 태풍 위험 평가 모델의 중요성이 증가하고 있으며, 정교한 평가를 위한 국지적 취약성을 반영하는 것이 중요하다. 자연 재해와 관련된 경제적 손실에 대한 실질적인 기존 연구들이 필수적인 위험 지표를 확인했지만 취약성과 경제적 손실 사이의 상관관계를 다루는 종합적인 연구가 여전히 필요하다. 본 연구의 목적은 태풍 매미로 인한 손실 데이터를 바탕으로 태풍 피해 예측 함수에 대한 평가지표를 개발하기 위함이다. 본 연구에서는 취약성 함수를 만들기 위해 풍속과 해안가로부터의 거리, 그리고 건물가치, 건물 유형, 층수 및 지하층 수의 정보를 사용하였으며 국내 보험사가 제공하는 태풍 매미의 실제 손실 기록을 분석하고 취약성 함수를 개발하여 최대 손실 발생의 예방에 기여하고자 하였다. 본 연구의 결과와 지표는 건물의 실제 재정 손실과 지역 취약성을 반영하는 정부 기관 및 보험 회사의 취약성 함수 개발을 위한 실질적인 지침으로 활용될 수 있다.

경찰화재조사의 개선방안에 관한 연구 (A Study on the Improvement Plans of Police Fire Investigation)

  • 서문수철
    • 한국화재조사학회지
    • /
    • 제9권1호
    • /
    • pp.103-121
    • /
    • 2006
  • 우리나라에서 발생한 화재 원인조사 대부분은 소방관서에서 초기조사, 경찰관서에서 수사가 진행되고 있으며, 보다 난해하거나 이해관계가 복잡한 경우인 일부만이 경찰에서 심도 있게 조사하고 경찰조사 시 감정이 필요한 경우 감정기관에 감정의뢰 후 경찰관서 자체조사만으로 끝나며, 점차 전문기관에 의뢰되고 있는 건수가 증가하고 있는 실정이나 많은 문제점을 안고 있어 이에 대안을 제시한다. 국내 화재사고 발생 건수는 소방방재청 통계 연간 약 30만 건으로 추산되나, 전국 경찰화재감식 전문 요원(국립과학수사연구소 전문화 교육 이수자)은 80여명에 지나지 않으며, 국립과학수사연구소 화재감정 관련 연구원은 전국에 15명인 것에 비추어 사건화 된 화재에 대한 감식 감정 인력은 턱없이 모자라 과중한 업무를 수행하고 있는 실정이다. 가연성 액체에 의한 방 실화 시 바닥재의 연소형태를 비교 연구함으로써 연소에 사용된 연소촉매제에 대하여 추론 할 수 있는 연구를 실시하여 모델을 제시하였다. 화재사건 관련 감식 감정 업무를 담당하고 있는 경찰 및 국립과학수사연구소의 과중한 업무의 부담인 의뢰 건수의 폭주로, 경찰 화재 감식의 대상 중 범죄혐의(방화, 실화 등)가 있는 사건은 전체 조사 건수의 20% 미만이고, 나머지 80%에 달하는 사건이 범죄혐의 없는 제조물 관련 또는 이재 관계의 민사 소송 사건에 지나지 않는 것이 현실이다. 본 연구는 경찰화재조사 및 소방화재조사에 대한 검토와 문제점 대안 등을 제시하여 화재사건과 관련하여 경찰 소방 양 기관에서 합동으로 사건을 처리하는 것이 과오를 범하지 않는 효율적이고 과학적인 수사가 될 수 있다는 제도개선이 필요함이 요구된다.

  • PDF