• Title/Summary/Keyword: floor slab

Search Result 311, Processing Time 0.024 seconds

Noise control of a slab using the laminated composite damping system (평판 부착형 제진시스템을 이용한 구조기인 소음 저감에 관한 연구)

  • Hwang, Jae-Seung;Kim, Gwang-Young;Hong, Geon-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.403-407
    • /
    • 2009
  • It is reported that the heavy weight floor impact noise of a slab system is very sensitive to the location of microphone and impact load. In addition, it is known that the aspect raio, thickness and boundary condition of a slab also have great effect on the noise induced by impact load. However, the effect has been mainly evaluated by experimental test and numerical analysis is nearly performed to verify the effect quantitatively. In this study, the effect of the aspect ratio, thickness and boundary condition on the heavy weight floor impact noise is examined through numerical analysis for simple rectangular slab system. The results show that the thickness and boundary condition have a strong correlation with the noise of the slab, on the contrary, the aspect ratio has little relation with the noise.

  • PDF

The numerical analysis. of heavy weight impact noise for an apartment house (공동주택 모델링을 통한 중량충격음 예측에 관한 연구)

  • Hwang, Jae-Seung;Moon, Dae-Ho;Yoon, Young-Bae;Hong, Geon-Ho;Park, Hong-Gun;Hong, Sung-Gul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.527-532
    • /
    • 2008
  • In this study, numerical analysis is performed to investigate the sound radiation characteristics of an apartment house according to the type of the slab system. In order to satisfy the boundary condition of the apartment house, the whole floor is modelled with FEM model for three different structural system: wall, RC, flat slab system. From the analytical results, it Is shown that heavy weight floor impact noise of wail type slab is larger than that of the other slab systems and the noise radiated from the wall have great effect on the sound pressure level. The results also show that the vibration energy of RC or flat slab system is widely distributed over the whole slab, which is main reason that the noise induced by the slab systems is reduced in comparison with wail slab system.

  • PDF

The Numerical Analysis of Heavy Weight Impact Noise for an Apartment House (공동주택 모델링을 통한 중량충격음 예측에 관한 연구)

  • Hwang, Jae-Seung;Moon, Dae-Ho;Park, Hong-Gun;Hong, Sung-Gul;Hong, Geon-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.2
    • /
    • pp.162-168
    • /
    • 2009
  • In this study, numerical analysis is performed to investigate the sound radiation characteristics of an apartment house according to the type of the slab system. In order to satisfy the boundary condition of the apartment house, the whole floor is modelled with FEM model for three different structural system: wall, RC, flat slab system. From the analytical results, it is shown that heavy weight floor impact noise of wall type slab is larger than that of the other slab systems and the noise radiated from the wall have great effect on the sound pressure level. The results also show that the vibration energy of RC or flat slab system is widely distributed over the whole slab, which is main reason that the noise induced by the slab systems is reduced in comparison with wall slab system.

Practical Vibration Analysis of Deck Floor Slab (데크 바닥판 구조물의 실용적인 진동해석)

  • Kim, Gee-Cheol
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.18 no.1
    • /
    • pp.61-69
    • /
    • 2005
  • As long-span and light-weight deck floor slab are flexible and have low inherent damping, the significant floor vibration could be induced by residents' activities. These floor vibrations affect to safety and serviceability of building structures. So the vibration criteria are applied to the quality assessment of building structure. Therefore, the accurate vibration analysis should be performed for the correct assessment of deck floor slab. In this paper, practical analysis method with considering orthotropic rigidity of deck floor is proposed tot the accurate vibration analysis of dock floor slabs with form deck plates.

Vibration performance of composite steel-bar truss slab with steel girder

  • Liu, Jiepeng;Cao, Liang;Chen, Y. Frank
    • Steel and Composite Structures
    • /
    • v.30 no.6
    • /
    • pp.577-589
    • /
    • 2019
  • In this study, on-site testing was carried out to investigate the vibration performance of a composite steel-bar truss slab with steel girder system. Ambient vibration was performed to capture the primary vibration parameters (natural frequencies, damping ratios, and mode shapes). The composite floor possesses low frequency (< 10 Hz) and damping (< 2%). Based on experimental, theoretical, and numerical analyses on natural frequencies and mode shapes, the boundary condition of SCSC (i.e., two opposite edges simply-supported and the other two edges clamped) is deemed more reasonable for the composite floor. Walking excitations by one person (single excitation), two persons (dual excitation), and three persons (triple excitation) were considered to evaluate the vibration serviceability of the composite floor. The measured acceleration results show a satisfactory vibration perceptibility. For design convenience and safety, a crest factor ${\beta}_{rp}$ describing the ratio of peak acceleration to root-mean-square acceleration induced from the walking excitations is proposed. The comparisons of the modal parameters determined by ambient vibration and walking tests reveal the interaction effect between the human excitation and the composite floor.

Behaviour of RC beam-column joint with varying location of construction joints in the column

  • Vanlalruata, Jonathan;Marthong, Comingstarful
    • Earthquakes and Structures
    • /
    • v.20 no.1
    • /
    • pp.29-38
    • /
    • 2021
  • According to ACI 224.3R-95 (ACI, 2013), construction joints (cold joint) in the column are to be provided at the top of floor slab for column continuing to the next floor and underside of floor slab and beam. A recent study reveals that providing cold joint of the mentioned location significantly reduced the seismic performance of the frame structures. Since, the construction joints in multi-story frame structures normally provided at the top of the floor slabs and at soffit of the beam in the column. This study investigated the effect of construction joint at various location in the column of beam-column joint such as at the top of floor slab, soffit level of the beam, half the depth of beam below the soffit of the beam and at a full depth of the beam below the soffit of the beam. The study revealed that there is an improvement in seismic capacity of the specimens as the location of cold joint is placed away from the soffit of the beam for lower story column.

Flexural Capacity of Encased Composite Beam with Hollow Core PC Slabs (매입형 합성보의 휨 성능 평가 -속 빈 프리캐스트 콘크리트 슬래브와 비대칭 H형강 철골보-)

  • Heo, Byung Wook;Bae, Kyu Woong;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.5 s.72
    • /
    • pp.587-598
    • /
    • 2004
  • In this study, an experiment was conducted on the Slim Floor system, using a hollow core PC slab, which could reduce the over-all depth of a composite beam. The Slim Floor system is a method used in steel frame multi-story building construction, in which the structural depth of each floor is minimized after incorporating the steel floor beams within the depth of the concrete floor slab. This experimental study focused on the flexural behavior of the partially connected Slim Floor system with asymmetric steel beams encased in hollow core PC slabs. Ten full-scale specimens were constructed and tested in this study, with different steel beam heights, hollow core PC slabs, slab widths, and PC slab bearings. Observations made in line with the experiments indicated that the degree of shear connection without additional shear connection was 0.48-0.98 times more than that of the full shear connection, due to inherent mechanical and chemical bond stress.

Evaluation on in-situ Heat Exchange Efficiency of Energy Slab According to Pipe Materials and Configurations (파이프 재질 및 형태에 따른 에너지 슬래브의 현장 열교환 성능 평가)

  • Lee, Seokjae;Oh, Kwanggeun;Han, Shin-in;Park, Sangwoo;Choi, Hangseok
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.13 no.4
    • /
    • pp.1-7
    • /
    • 2017
  • The energy slab is a ground coupled heat exchanger equipped in building slab structures, which represents a layout similar to the horizontal ground heat exchanger (GHEX). The energy slab is installed as one component of the floor slab layers in order to utilize the underground structure as a hybrid energy structure. However, as the energy slab is horizontally arranged, its thermal performance is inevitably less than the conventional vertical GHEXs. Therefore, stainless steel (STS) pipes are alternatively considered as a heat exchanger instead of high density polyethylene (HDPE) pipes in order to enhance thermal performance of GHEXs. Moreover, not only a floor slab but also a wall slab can be utilized as a heat-exchangeable energy slab in order to maximize the use of underground space effectively. In this paper, four field-scale energy slabs were constructed in a test bed, which consist of the STS and HDPE pipe, and a series of thermal response tests (TRTs) was conducted to evaluate relative heat exchange efficiency per unit pipe length according to the pipe material and the configuration of energy slabs. The energy slab equipped with the STS pipe shows higher thermal performance than the energy slab with the HDPE pipe. In addition, thermal performance of the wall-type energy slab is almost equivalent to the floor-type energy slab.

Efficient Analysis of Biaxial Hollow Slab (2방향 중공슬래브의 효율적인 해석)

  • Park, Hyun-Jae;Kim, Hyun-Su;Park, Yong-Koo;Hwang, Hyun-Sik;Lee, Ki-Jang;Lee, Dong-Guen
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.362-367
    • /
    • 2008
  • Recently, the use of biaxial hollow slab is increased to reduce noise and vibration of the floor slab. Therefore, an efficient method for the vibration analysis of biaxial hollow slab is required to describe dynamic behavior of biaxial hollow slab. A finite element analysis is one of the method to analyze the biaxial hollow slab. It is necessary to use a refined finite element model for an accurate analysis of a floor slab with an effects of the hollow shape. But it would take a significant amount of computational time and memory if the entire building structure were subdivided into a finer mesh. Thus the proposed method uses equivalent plate model in this study. Dynamic analyses of an example structure subjected to walking loads were performed to verify the efficiency and accuracy of the proposed method.

  • PDF

Limit states of RC structures with first floor irregularities

  • Favvata, Maria J.;Naoum, Maria C.;Karayannis, Chris G.
    • Structural Engineering and Mechanics
    • /
    • v.47 no.6
    • /
    • pp.791-818
    • /
    • 2013
  • The seismic performance of reinforced concrete (RC) frame structures with irregularities leading to soft first floor is studied using capacity assessment procedures. The soft first story effect is investigated for the cases: (i) slab-column connections without beams at the first floor, (ii) tall first story height and (iii) pilotis type building (open ground story). The effects of the first floor irregularity on the RC frame structure performance stages at global and local level (limit states) are investigated. Assessment based on the Capacity Spectrum Method (ATC-40) and on the Coefficient Method (FEMA 356) is also examined. Results in terms of failure modes, capacity curves, interstory drifts, ductility requirements and infills behaviour are presented. From the results it can be deduced that the global capacity of the structures is decreased due to the considered first floor morphology irregularities in comparison to the capacities of the regular structure. An increase of the demands for interstory drift is observed at the first floor level due to the considered irregularities while the open ground floor structure (pilotis type) led to even higher values of interstory drift demands at the first story. In the cases of tall first story and slab-column connections without beams soft-story mechanisms have also been observed at the first floor. Rotational criteria (EC8-part3) showed that the structure with slab-column connections without beams exhibited the most critical response.