• 제목/요약/키워드: floor slab

검색결과 311건 처리시간 0.022초

평판 부착형 제진시스템을 이용한 구조기인 소음 저감에 관한 연구 (Noise control of a slab using the laminated composite damping system)

  • 황재승;김광용;홍건호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.403-407
    • /
    • 2009
  • It is reported that the heavy weight floor impact noise of a slab system is very sensitive to the location of microphone and impact load. In addition, it is known that the aspect raio, thickness and boundary condition of a slab also have great effect on the noise induced by impact load. However, the effect has been mainly evaluated by experimental test and numerical analysis is nearly performed to verify the effect quantitatively. In this study, the effect of the aspect ratio, thickness and boundary condition on the heavy weight floor impact noise is examined through numerical analysis for simple rectangular slab system. The results show that the thickness and boundary condition have a strong correlation with the noise of the slab, on the contrary, the aspect ratio has little relation with the noise.

  • PDF

공동주택 모델링을 통한 중량충격음 예측에 관한 연구 (The numerical analysis. of heavy weight impact noise for an apartment house)

  • 황재승;문대호;윤영배;홍건호;박홍근;홍성걸
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.527-532
    • /
    • 2008
  • In this study, numerical analysis is performed to investigate the sound radiation characteristics of an apartment house according to the type of the slab system. In order to satisfy the boundary condition of the apartment house, the whole floor is modelled with FEM model for three different structural system: wall, RC, flat slab system. From the analytical results, it Is shown that heavy weight floor impact noise of wail type slab is larger than that of the other slab systems and the noise radiated from the wall have great effect on the sound pressure level. The results also show that the vibration energy of RC or flat slab system is widely distributed over the whole slab, which is main reason that the noise induced by the slab systems is reduced in comparison with wail slab system.

  • PDF

공동주택 모델링을 통한 중량충격음 예측에 관한 연구 (The Numerical Analysis of Heavy Weight Impact Noise for an Apartment House)

  • 황재승;문대호;박홍근;홍성걸;홍건호
    • 한국소음진동공학회논문집
    • /
    • 제19권2호
    • /
    • pp.162-168
    • /
    • 2009
  • In this study, numerical analysis is performed to investigate the sound radiation characteristics of an apartment house according to the type of the slab system. In order to satisfy the boundary condition of the apartment house, the whole floor is modelled with FEM model for three different structural system: wall, RC, flat slab system. From the analytical results, it is shown that heavy weight floor impact noise of wall type slab is larger than that of the other slab systems and the noise radiated from the wall have great effect on the sound pressure level. The results also show that the vibration energy of RC or flat slab system is widely distributed over the whole slab, which is main reason that the noise induced by the slab systems is reduced in comparison with wall slab system.

데크 바닥판 구조물의 실용적인 진동해석 (Practical Vibration Analysis of Deck Floor Slab)

  • 김기철
    • 한국전산구조공학회논문집
    • /
    • 제18권1호
    • /
    • pp.61-69
    • /
    • 2005
  • 장경간화되고 경량화된 데크 바닥판 구조물은 부재가 유연하기 때문에 거주자의 움직임에 의하여 진동이 크게 발생할 수 있으며, 이러한 바닥판 진동은 건축물의 안전성뿐만 아니라 건축물의 사용성에도 많은 영향을 끼치므로 건축물의 품질 평가기준으로 사용되고 있다. 데크 바닥판 구조물의 올바른 사용성 평가를 위해서는 정확한 진동해석과 응답평가가 수반되어야한다. 본 논문에서는 데크 바닥판 구조물의 직교이방성을 고려한 여러 가지 모형화 방법을 적용하여 진동해석을 수행하였으며 모형화 방법에 따른 진동응답을 비교 분석하였다. 본 논문에서 제시한 데크 골 방향 강성에 대한 등가두께 모형화방법은 간단한 방법으로 데크 바닥판 구조물의 직교이방성을 간단한 방법으로 고려할 수 있으며, 정확한 진동응답을 얻을 수 있으므로 실무에서 실용적으로 활용할 수 있다.

Vibration performance of composite steel-bar truss slab with steel girder

  • Liu, Jiepeng;Cao, Liang;Chen, Y. Frank
    • Steel and Composite Structures
    • /
    • 제30권6호
    • /
    • pp.577-589
    • /
    • 2019
  • In this study, on-site testing was carried out to investigate the vibration performance of a composite steel-bar truss slab with steel girder system. Ambient vibration was performed to capture the primary vibration parameters (natural frequencies, damping ratios, and mode shapes). The composite floor possesses low frequency (< 10 Hz) and damping (< 2%). Based on experimental, theoretical, and numerical analyses on natural frequencies and mode shapes, the boundary condition of SCSC (i.e., two opposite edges simply-supported and the other two edges clamped) is deemed more reasonable for the composite floor. Walking excitations by one person (single excitation), two persons (dual excitation), and three persons (triple excitation) were considered to evaluate the vibration serviceability of the composite floor. The measured acceleration results show a satisfactory vibration perceptibility. For design convenience and safety, a crest factor ${\beta}_{rp}$ describing the ratio of peak acceleration to root-mean-square acceleration induced from the walking excitations is proposed. The comparisons of the modal parameters determined by ambient vibration and walking tests reveal the interaction effect between the human excitation and the composite floor.

Behaviour of RC beam-column joint with varying location of construction joints in the column

  • Vanlalruata, Jonathan;Marthong, Comingstarful
    • Earthquakes and Structures
    • /
    • 제20권1호
    • /
    • pp.29-38
    • /
    • 2021
  • According to ACI 224.3R-95 (ACI, 2013), construction joints (cold joint) in the column are to be provided at the top of floor slab for column continuing to the next floor and underside of floor slab and beam. A recent study reveals that providing cold joint of the mentioned location significantly reduced the seismic performance of the frame structures. Since, the construction joints in multi-story frame structures normally provided at the top of the floor slabs and at soffit of the beam in the column. This study investigated the effect of construction joint at various location in the column of beam-column joint such as at the top of floor slab, soffit level of the beam, half the depth of beam below the soffit of the beam and at a full depth of the beam below the soffit of the beam. The study revealed that there is an improvement in seismic capacity of the specimens as the location of cold joint is placed away from the soffit of the beam for lower story column.

매입형 합성보의 휨 성능 평가 -속 빈 프리캐스트 콘크리트 슬래브와 비대칭 H형강 철골보- (Flexural Capacity of Encased Composite Beam with Hollow Core PC Slabs)

  • 허병욱;배규웅;문태섭
    • 한국강구조학회 논문집
    • /
    • 제16권5호통권72호
    • /
    • pp.587-598
    • /
    • 2004
  • 본 연구에서는 합성보의 전체 춤을 절감할 수 있도록 속 빈 프리캐스트 콘크리트 슬래브를 철골보의 춤내에 삽입하여 일체화함으로써 철골조 고층건물에서 층고를 최소화 할 수 있는 이른바 "슬림플로어"공법에 대한 연구를 수행하였다. 본 연구는 콘크리트에 매입된 비대칭 철골보를 가지는 불완전 합성 슬림플로어 시스템의 휨 거동에 관한 것이다. 총 10개의 실대형 실험체를 철골보 춤, 속빈 프리캐스트 콘크리트 슬래브 춤, 슬래브 유효폭, 및 콘크리트 슬래브의 지지방식 별로 제작하여 실험을 수행하였다. 실험결과, 매입형 합성보의 경우, 별도의 전단연결재를 설치하지 않아도 자체가 가지고 있는 기계적 화학적 부착응력으로 인해 완전합성보에 비해서 0.48~0.98의 전단합성비를 나타내었다.

파이프 재질 및 형태에 따른 에너지 슬래브의 현장 열교환 성능 평가 (Evaluation on in-situ Heat Exchange Efficiency of Energy Slab According to Pipe Materials and Configurations)

  • 이석재;오광근;한신인;박상우;최항석
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권4호
    • /
    • pp.1-7
    • /
    • 2017
  • The energy slab is a ground coupled heat exchanger equipped in building slab structures, which represents a layout similar to the horizontal ground heat exchanger (GHEX). The energy slab is installed as one component of the floor slab layers in order to utilize the underground structure as a hybrid energy structure. However, as the energy slab is horizontally arranged, its thermal performance is inevitably less than the conventional vertical GHEXs. Therefore, stainless steel (STS) pipes are alternatively considered as a heat exchanger instead of high density polyethylene (HDPE) pipes in order to enhance thermal performance of GHEXs. Moreover, not only a floor slab but also a wall slab can be utilized as a heat-exchangeable energy slab in order to maximize the use of underground space effectively. In this paper, four field-scale energy slabs were constructed in a test bed, which consist of the STS and HDPE pipe, and a series of thermal response tests (TRTs) was conducted to evaluate relative heat exchange efficiency per unit pipe length according to the pipe material and the configuration of energy slabs. The energy slab equipped with the STS pipe shows higher thermal performance than the energy slab with the HDPE pipe. In addition, thermal performance of the wall-type energy slab is almost equivalent to the floor-type energy slab.

2방향 중공슬래브의 효율적인 해석 (Efficient Analysis of Biaxial Hollow Slab)

  • 박현재;김현수;박용구;황현식;이기장;이동근
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2008년도 정기 학술대회
    • /
    • pp.362-367
    • /
    • 2008
  • Recently, the use of biaxial hollow slab is increased to reduce noise and vibration of the floor slab. Therefore, an efficient method for the vibration analysis of biaxial hollow slab is required to describe dynamic behavior of biaxial hollow slab. A finite element analysis is one of the method to analyze the biaxial hollow slab. It is necessary to use a refined finite element model for an accurate analysis of a floor slab with an effects of the hollow shape. But it would take a significant amount of computational time and memory if the entire building structure were subdivided into a finer mesh. Thus the proposed method uses equivalent plate model in this study. Dynamic analyses of an example structure subjected to walking loads were performed to verify the efficiency and accuracy of the proposed method.

  • PDF

Limit states of RC structures with first floor irregularities

  • Favvata, Maria J.;Naoum, Maria C.;Karayannis, Chris G.
    • Structural Engineering and Mechanics
    • /
    • 제47권6호
    • /
    • pp.791-818
    • /
    • 2013
  • The seismic performance of reinforced concrete (RC) frame structures with irregularities leading to soft first floor is studied using capacity assessment procedures. The soft first story effect is investigated for the cases: (i) slab-column connections without beams at the first floor, (ii) tall first story height and (iii) pilotis type building (open ground story). The effects of the first floor irregularity on the RC frame structure performance stages at global and local level (limit states) are investigated. Assessment based on the Capacity Spectrum Method (ATC-40) and on the Coefficient Method (FEMA 356) is also examined. Results in terms of failure modes, capacity curves, interstory drifts, ductility requirements and infills behaviour are presented. From the results it can be deduced that the global capacity of the structures is decreased due to the considered first floor morphology irregularities in comparison to the capacities of the regular structure. An increase of the demands for interstory drift is observed at the first floor level due to the considered irregularities while the open ground floor structure (pilotis type) led to even higher values of interstory drift demands at the first story. In the cases of tall first story and slab-column connections without beams soft-story mechanisms have also been observed at the first floor. Rotational criteria (EC8-part3) showed that the structure with slab-column connections without beams exhibited the most critical response.