• Title/Summary/Keyword: floor post

Search Result 128, Processing Time 0.031 seconds

Case study on frequency bands contributing the single number quantity for heavy-weight impact sound based on assessment method changes (중량충격음 평가방법 변화에 따른 단일수치평가량 기여 주파수 대역 사례 분석)

  • Hye-kyung Shin;Sang Hee Park;Kyoung-woo Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.6
    • /
    • pp.565-571
    • /
    • 2023
  • With the introduction of the post-verification system, the measurement of floor impact noise performance on-site has become mandatory, and the evaluation method has changed. To track the performance changes since the policy implementation, research is needed on how the characteristics of heavyweight impact sound change according to the varied evaluation method. In this study, we analyzed the contribution rate of the frequency band-specific sound pressure level on the single-number quantity for a multi-family housing unit with the same floor plan and floor structure, comprising 59 households, based on the changed impact sources and evaluation indicators. It is difficult to compare simply because the method of calculating contributions by frequency band according to the single-day evaluation is different, but the average contribution rate of 63 Hz was 80.8 % in the evaluation method before the introduction of the post-confirmation system (Tire measurement and evaluated as L'i,Fmax,AW), and the average contribution rate of 125 Hz was 19.2 %. The current evaluation method (rubber ball measurement and evaluation as L'iA,Fmax) shows that the contribution rate has decreased to 33.1 % on average at 50 Hz ~ 80 Hz, 58.7 % on average at 100 Hz ~ 160 Hz, 6.9 % on average at 200 Hz ~ 315 Hz, and 1.3 % on average at 400 Hz ~ 630 Hz. This result is a case analysis for the target apartment house, and it is necessary to analyze measurement data for more diverse apartment houses.

Post-earthquake building safety evaluation using consumer-grade surveillance cameras

  • Hsu, Ting Y.;Pham, Quang V.;Chao, Wei C.;Yang, Yuan S.
    • Smart Structures and Systems
    • /
    • v.25 no.5
    • /
    • pp.531-541
    • /
    • 2020
  • This paper demonstrates the possibility of evaluating the safety of a building right after an earthquake using consumer-grade surveillance cameras installed in the building. Two cameras are used in each story to extract the time history of interstory drift during the earthquake based on camera calibration, stereo triangulation, and image template matching techniques. The interstory drift of several markers on the rigid floor are used to estimate the motion of the geometric center using the least square approach, then the horizontal interstory drift of any location on the floor can be estimated. A shaking table collapse test of a steel building was conducted to verify the proposed approach. The results indicate that the accuracy of the interstory drift measured by the cameras is high enough to estimate the damage state of the building based on the fragility curve of the interstory drift ratio. On the other hand, the interstory drift measured by an accelerometer tends to underestimate the damage state when residual interstory drift occurs because the low frequency content of the displacement signal is eliminated when high-pass filtering is employed for baseline correction.

A Study on the Rent Characteristics of Small Shopping Malls

  • KIM, Sun-Ju
    • Journal of Distribution Science
    • /
    • v.20 no.12
    • /
    • pp.109-116
    • /
    • 2022
  • Purpose: The purpose of this study is to analyze the rental determinants of a small shopping mall located in Seoul, Korea, and the characteristics of four commercial districts (CBD, GBD, YSD, etc.). Research design, data, and methodology: For the characteristics of the data, descriptive statistics and frequency analysis were used. Artificial Neural Networks (ANNs) have been used as rental determinants for small shopping malls. The characteristics of 4 commercial districts were analyzed using Analysis of variance (ANOVA) and post-hoc analysis. Results: 1) CBD 14.8%, GBD 16.7%, YSD 13.0%, others 55.6%. 2) The order of important variables affecting rent: CBD=1> GBD=1> vacancy rate> rental index> number of buildings> YBD=1> average gross floor area> conversion rate> average floor. 3) Characteristics of commercial district: Rents in CBD and GBD are high. The conversion rate is high in the GBD commercial area. The number of buildings is high in the CBD. The average area of GBD is larger than that of other commercial districts. Conclusions: 1) Several factors should be considered when investing in or renting a small shopping mall. 2) Depending on the investment and business purpose, factors such as rent, conversion rate, building, and area average should be considered.

Dynamic Characteristic of Composite Beam using the Sandwich Plate System (샌드위치 플레이트 시스템을 이용한 합성보의 동적 특성)

  • Ryu, Jae-Ho;Ju, Young-Kyu;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.14 no.4
    • /
    • pp.65-72
    • /
    • 2014
  • To improve the noise and vibration problems of the existing public parking systems, new floor system was proposed. This system consists of the Sandwich Plate System(SPS), steel beam and post-tensioned steel tendons. To verify the dynamic characteristics such as the natural frequency and damping ratio of the system, the free vibration test was performed. Test results showed that the natural frequency of the SPS composite beam was 23.8Hz and it was increased by 3.8% by installing the post-tensioned tendons. The damping ratio of the specimen with tendons was about 1.64%.

Post-earthquake fire performance-based behavior of reinforced concrete structures

  • Behnama, Behrouz;Ronagh, Hamid R.
    • Earthquakes and Structures
    • /
    • v.5 no.4
    • /
    • pp.379-394
    • /
    • 2013
  • Post-earthquake fire (PEF) can lead to a rapid collapse of buildings damaged partially as a result of prior earthquake. Almost all standards and codes for the design of structures against earthquake ignore the risk of PEF, and thus buildings designed using those codes could be too weak when subjected to a fire after an earthquake. An investigation based on sequential analysis inspired by FEMA356 is performed here on the Immediate Occupancy, Life Safety and Collapse Prevention performance levels of structures, designed to the ACI 318-08 code, after they are subjected to an earthquake level with PGA of 0.35g. This investigation is followed by a fire analysis of the damaged structures, examining the time taken for the damaged structures to collapse. As a point of reference, a fire analysis is also performed for undamaged structures and before the occurrence of earthquake. The results indicate that the vulnerability of structures increases dramatically when a previously damaged structure is exposed to PEF. The results also show that the damaging effects of post-earthquake fire are exacerbated when initiated from the second and third floor. Whilst the investigation is made for a certain class of structures (conventional buildings, intermediate reinforced structure, 3 stories), the results confirm the need for the incorporation of post-earthquake fire into the process of analysis and design, and provides some quantitative measures on the level of associated effects.

Methodology for investigating the behavior of reinforced concrete structures subjected to post earthquake fire

  • Behnam, Behrouz;Ronagh, Hamid R.;Baji, Hassan
    • Advances in concrete construction
    • /
    • v.1 no.1
    • /
    • pp.29-44
    • /
    • 2013
  • Post earthquake fire (PEF) can lead to the collapse of buildings that are partially damaged in a prior ground-motion that occurred immediately before the fire. The majority of standards and codes for the design of structures against earthquake ignore the possibility of PEF and thus buildings designed with those codes could be too weak when subjected to a fire after an earthquake. An investigation based on sequential analysis inspired by FEMA356 is performed here on the Life-Safety performance level of structures designed to the ACI 318-08 code after they are subjected to two different earthquake levels with PGA of 0.35 g and 0.25 g. This is followed by a four-hour fire analysis of the weakened structure, from which the time it takes for the weakened structure to collapse is calculated. As a benchmark, the fire analysis is also performed for undamaged structure and before occurrence of earthquake. The results show that the vulnerability of structures increases dramatically when a previously damaged structure is exposed to PEF. The results also show the damaging effects of post earthquake fire are exacerbated when initiated from second and third floor. Whilst the investigation is for a certain class of structures (regular building, intermediate reinforced structure, 3 stories), the results confirm the need for the incorporation of post earthquake fire in the process of analysis and design and provides some quantitative measures on the level of associated effects.

Case Study On The Seismic Design Strategy For Post-Quake Functional Buildings In China

  • Peng Liu;Xue Li;Yu Cheng;Xiaoyu Gao;Jinai Zhang;Yongbin Liu
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.3
    • /
    • pp.251-262
    • /
    • 2023
  • In response to China's "Regulations on the Management of Earthquake Resistance of Building Constructions" on the provision of eight types of important buildings to maintain functional after fortified earthquakes occur, "Guidelines for Seismic Design of post-quake functional buildings (Draft for Review)" distinguishes Class I and Class II buildings, and gives the performance objectives and seismic verification requirements for design earthquakes and severe earthquakes respectively. In this paper, a hospital and a school building are selected as examples to design according to the requirements of fortification of Intensity 8 and 7 respectively. Two design strategies, the seismic isolation scheme and energy dissipation scheme, are considered which are evaluated through elastic-plastic dynamic time-history analysis to meet the requirement of post-quake functional buildings. The results show that the seismic isolation design can meet the requirements in the above cases, and the energy dissipation scheme is difficult to meet the requirements of the "Guidelines" on floor acceleration in some cases, for which the scheme shall be made valid through the seismic resilience assessment. The research in this paper can provide a reference for designers to choose schemes for post-quake functional buildings.

Post Occupancy Evaluation for Office Building with An Underfloor Air Distribution System (바닥공조 시스템이 적용된 사무공간의 거주후 성능평가)

  • Yoon, Seong-Hoon;Jang, Hyang-In;Jung, Hae-Kwon;Choi, Sun-Kyu;Yu, Ki-Hyung
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.78-85
    • /
    • 2011
  • In this study, an underfloor air distribution(UFAD) system installed on the S. office building was evaluated for its indoor environmental quality performance. Field measurement and survey were conducted for the overall POE(Post Occupied Evaluation). PMV(including temperature, humidity, air velocity and globe temperature) and several environmental components were measured while thermal comfort, thermal sensation, acoustical environment and others. were investigated through survey. Except for the direct upper part of the air supply diffuser on the floor, the indoor velocity was less than 0.25m/s, which has been suggested by ASHRAES tandard 55 as the limit for thermal comfort. MRT of the perimeter zone of the room showed a higher value than that in the interior because of the introduced solar radiation through the building envelope. PMV was generally maintained in the range of thermal comfort (from -0.5 to +0.5), though it weighted to the warm side. It was reported to have 61% positive response on thermal comfort and 55% on neutral thermal sensation. The results of each survey item showed some gender-based differences. Specifically, female respondents had higher degree of dissatisfaction with indoor air cleanness and acoustical privacy. The working surface showed more than 400 lux and the equivalent noise level showed less than 50 dB(A). In conclusion, the results of the measurement and survey showed good agreement. Indoor environmental quality of the subject office room where the UFAD system was installed showed an overall excellent performance.

The Effect of Therapeutic Ultrasound and Static Stretching of the Hamstring Muscle on Flexibility and Static Balance Ability (초음파 치료와 정적 스트레칭이 뒤넙다리근의 유연성과 정적균형에 미치는 영향)

  • Cho, Seung-bong;Park, Mi-young;Won, Ji-sun;Kim, Ye-lin;Hong, Joon-taek;Kim, Seong-ho
    • Journal of Korean Physical Therapy Science
    • /
    • v.26 no.1
    • /
    • pp.45-53
    • /
    • 2019
  • Background: The purpose of present study was to examine the effect of ultrasound therapy and static stretching on hamstring length and balance. Design: Randomized Controlled Trial. Methods: A total of 30 adults in S college, Seongnam city, Gyeonggi-do, between the ages of 20-30 were randomly assigned to two groups. Group 1 (n=15) had ultrasound therapy, called US group. Group 2 (n=15) had static stretching, called SS group. Measurements were taken prior to starting the program and after completing the experiment using Finger to floor test and Active knee extension test to get the results of hamstring flexibility and the ability of static balance. Paired t-test was used to compare each group pre-test values to post-test values and to compare US post-test values to SS post-test values on PASW 18.0. Results: 1) Both hamstring SS group and US group had significant increase (p<.05) in Finger to floor test and Active knee extension test. 2) Dominant leg standing had significant change (p<.05) only in US group. 3) There was no significant difference between US group and SS group. Conclusion: Results showed that US group and SS group had an effect on changes in hamstring length (p<.05). However, they did not show a significant increase in static balance. Further effective studies on hamstring SS group and US group were needed based on this examination.

A Comparative Study on the Effects on Urinary Incontinence between Pelvic Floor Muscle Exercise and Magnetic Stimulation Therapy (지역사회 요실금 여성의 골반저근운동과 자기장자극 효과비교)

  • Cho, Myung-Sook;Kang, Hae-Young
    • Research in Community and Public Health Nursing
    • /
    • v.19 no.4
    • /
    • pp.696-703
    • /
    • 2008
  • Purpose: To Perform a randomized comparative study investigating the effects of Pelvic Floor Muscle Exercise(PME) and Magnetic Stimulation Therapy(MST) and to identified the problems in each of PME & MST Method: Forty-nine patients with mild stress incontinence were randomly assigned to either of two treatment groups (24 patients in the PME group and 25 in the MST group). The PME group had a video exercising program for 40 times every day during 6 weeks. The MST group was treated with BioCon-2000TM, 2times/ week for six weeks. Pre-test and post-test were performed by Prineometer, 1-hour pad test. and Jackson's BFLUTS questionnaire of Jackson. Collected data were analysed using SAS 9.1 by frequency, Kolmogorov-Smirnov Z. Chi Square-test, t-test, Fisher Exact probability test, Paired t-test, and Wilcoxon's rank sum test. Results: In comparison between before and after PME and MST, statistically significant difference was observed in maximal vaginal pressure, duration of vaginal contraction, amount of urine, and symptom of urination. In the comparison of the effectiveness between PME & MST, only the maximal of vaginal pressure (Z=2.58, p= .010) was significantly different. Conclusion: The factor more effective in the MST group than in the PME group was high compliance.

  • PDF