• Title/Summary/Keyword: floor heating

Search Result 398, Processing Time 0.028 seconds

A Study of the Living Culture of Transnational Married Women and of Children's Outdoor Plays in their Hometown : Jilin Province - Jian in China (이주여성 출신 지역 생활문화와 아동놀이에 관한 연구 : 중국 길림성 집안시를 중심으로)

  • Song, Soon
    • Journal of Families and Better Life
    • /
    • v.28 no.1
    • /
    • pp.131-143
    • /
    • 2010
  • The purpose of this study is to understand the living culture of transnational married women and to analyze the out door play of children in their hometown. The data was collected through observation from 27th June to 7th July 2008 in Jian, Jilin Province China. The children's play and lifestyles were observed, and data pertaining to the culture of the people were collected by a teacher and staff. We also visited the residents for housing information. The results are given below. 1. They dressed in Korean clothes on festive days and the boys put on a hood. They had eating habits which included cooking for themselves or buying semi-manufactured goods but did not use, instant food. The housing habits involved a combination of cooking and heating by Korean floor heating system(Ondol). They utilized outdoor space to grow vegetables. Those with a fulltime job(teacher) preferred to live in an apartment but an apartment was too expensive. Public utility charges and traffic expenses were cheap. 2. The main festive days are the lunar New Year's Day and Chuseok. The children returned home and enjoyed the festive day with their parents. The language used are Korean language and Chinese. Some Korean words and phrases in Jian Joseonjok have different meanings as compared to how they are used in Korea. A capping ceremony did not to celebrate becoming an adult from an adolescent. Couples performed a wedding ceremony at a wedding hall attended by their parents and invited relatives from both families. The relatives gave the couple a wedding gift. They did not go on a wedding trip as it was not affordable but instead spent their wedding night at a hotel in this culture. When someone dies, they bury the body after cremation. They perform a memorial service for three years on the birthday of the departed. They have a banquet on the 60th birthdays with their relatives and neighbours and are typically presented with a carp for longevity. 3. They understand capitalism and therefore send their children to school to improve their social position. The Korean and Chinese languages are required subjects in school. The students choose a second language(English or Russian). They prefer English class but at the time of this study an English class was not offered at the school in Jian Joseonjok. Therefore the children entered a Chinese school. 4. The children play outdoor games such as Y$\acute{a}$o J$\grave{i}\bar{a}$(要家), X$\grave{i}$ang g$\grave{i}$(象棋), T$\grave{i}\grave{a}$o p$\acute{i}$ j$\grave{i}$n(r)(跳皮節), D$\grave{o}$uch ing g$\grave{u}$n 凍冷根, B$\bar{e}$i B$\bar{e}$i 背背, and soccer. They play games according to the season.

Energy Performance Evaluation of Low Energy Houses using Metering Data (실측데이터를 이용한 저에너지주택의 에너지성능평가)

  • Baek, Namchoon;Kim, Sungbum;Oh, Byungchil;Yoon, Jongho;Shin, Ucheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.369-374
    • /
    • 2015
  • This study analyzed analyzes the energy performance of six houses in Daejeon completed which were built in 2011. Observed The observed houses, which were all designed and constructed inof the same size and structure, are were highly insulated with triple Low-E coating windows; the insulation level of the walls is was $0.13W/m^2K$ and that of the roof is was $0.10W/m^2K$. As electric houses, all of the energy supplied to the houses, including for cooking, is was supplied by electricity. A and 3~4 kWp of photovoltaic system and a 3~5 kW of ground source heat pump (GSHP) were installed in each house tofor providing provide space heating/and cooling and hot water are installed. We constructed a Web-based remote monitoring system in order to understand energy consumption and the dynamic behavior of the energy system. T, and the results of our metering data analysis of 2013 are as follows. First, the annual residential energy consumption is was 4,400 kWh (${\sigma}=1,209$) and GSHP energy consumption is was 5,182 kWh (${\sigma}=1,164$). Second, residential energy consumption ranked highest in average energy usage, with at 45% of the total, followed by heating with at 30%, hot water supply with at 17% and cooling with at 6%. Third, the average energy independence rate is was 51.8%, the GFA (Gross gross floor area) criteria average energy consumption unit is was $48.7kWh/m^2yr$ (${\sigma}=10.1$), and the net energy consumption unit (except the energy yield of the PV systems) is was $24.7kWh/m^2yr$ (${\sigma}=8.8$).

Emission Characteristics of Volatile Organic Compounds from Building Flooring Materials (건축용 바닥재로부터의 휘발성유기화합물 방출특성)

  • Yun, Joong-Seop;Lee, Myong-Hwa;Eom, Seok-Won;Kim, Min-Young;Kim, Jong-Ho;Kim, Shin-Do
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.10
    • /
    • pp.973-978
    • /
    • 2010
  • The emission of volatile organic compounds (VOCs) from building materials is one of great concerns due to maintain airtight condition of a building to reduce energy consumption, and it causes the deterioration of indoor air quality. Therefore, the emission characterization of VOCs from building materials is necessary to improve indoor air quality. Emission characteristics of VOCs from a plywood flooring that is one of the most commonly used materials in an under-heating system, and from an adhesive that is generally used to stick a plywood flooring to a concrete floor were investigated using an emission chamber test in this study. It was found that the VOCs emission factor was dependent upon and proportional to indoor temperature, and the emission characteristics were closely related to the existing places and conditions of VOCs sources inside the building materials. Maximum emission factors of hexane and toluene from building materials were generally observed at the beginning, however, only that of toluene from a plywood flooring was shown after 6 hours from the beginning. It could be considered that the existing place and condition of toluene source inside a plywood flooring could influence on the VOCs emission. From this study, bake-out time more than 72 hours could be recommended before moving in to avoid the exposure to high concentration of VOCs emitted from an under-heating system.

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF

A study on hospice care awareness and user satisfaction with intensive care unit facilities -Centering on capital district- (호스피스 케어인식도와 시설이용 만족도에 관한 연구 -수도권 중심으로-)

  • Kim, Moon-Dol;Cho, Sung-Je
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.157-164
    • /
    • 2014
  • This study aims to investigate hospice care awareness, user satisfaction with intensive care unit facilities and the difference in hospice care awareness level. A survey of 160 people including the intensive care patients in capital district areas and their family members was conducted from March $10^{th}$ until $July31^{st}$ of 2013. As an analytical method, the SPSSWIN18.0 program was used and the sample size followed Cohen's sample extracting formula of G*Power 3.1, an analytical program for test power. The mean, standard deviation and regression analysis have been statistically carried out. The results indicate that the care awareness of hospices have meaningful relations with age, religion and marital status. As for the satisfaction level with hospices, the facilities in the countryside are preferred to those in the cities, and the hospice rooms with Korean floor heating system is preferred to rooms with bed. The implication of this study is expected to become a basic reference to the improvement of the hospice system, seen from the result of survey with highly favorable response for care units in hospices.

A Study on the Types and Changes of the Urban Houses in the Korean Inland during the Period 1910-1945 (한국(韓國) 근대기(近代期) 내륙지방(內陸地方) 도시주택(都市住宅)의 유형(類型)과 변천(變遷)에 관한 연구(硏究))

  • Kim, Tai-Young
    • Journal of architectural history
    • /
    • v.7 no.3 s.16
    • /
    • pp.53-66
    • /
    • 1998
  • In the meantime, the study of traditional and contemporary house had been produced so many achievements in korea, but modern house is yet to be solved, Accordingly, It is necessary to develop and present the basic research data in order to build up an objective study for urban house in the modern age(1910-1945), Following to a study on the foreigner's house in grid-type settlement of Open Ports, in this research is to investigate and analyze modern houses of urban areas in korean inland, and then clarify types and changes of them. In the first year($1995{\sim}96$), the modern houses of Central Inland Districts(arrounding river Kumgang)-Kunsan kanggyong Puyo Kongju Pugang Chongju were investigated by the layout of room, the construction and materials, the design and style, etc. In the second year($1996{\sim}97$), the modern houses of Open Market(開市場)-Seoul Taegu Kwangju Taejon Chonju were conducted to investigate as above. The traditional house transformed by differentiation and addition of room(kan), the various types were respectively adopted for the korean reforming and western cultural house. In the layout of room, the types of plan were gradually concentrated from the single wings of korean traditional house. The korean traditional house was later improved through the introduction of entrance, corridor, and internal toilet/bathroom. But the korean under-floor heating system(andal) and a series of three rooms had been entirely maintained, composed of master bedroom/living room(daechung)/room. And the traditional town house with shop and storage, being built closely to each other and walled up both sides, it had taken gradually the extensive characteristics in itself. By the displacement of shop/dwelling/ storage. the various types were respectively adopted for the separated, multi-storied, and complex type. The type of them was gradually changed to the narrow and linear form. And so with the stockpile of fundamental datas about modern houses in korean urban areas, we expect these results contribute to the knowledge of the spatial characteristics of urban house at present which are required to the understanding of transition as well as types.

  • PDF

Progressive collapse of steel-framed gravity buildings under parametric fires

  • Jiang, Jian;Cai, Wenyu;Li, Guo-Qiang;Chen, Wei;Ye, Jihong
    • Steel and Composite Structures
    • /
    • v.36 no.4
    • /
    • pp.383-398
    • /
    • 2020
  • This paper investigates the progressive collapse behavior of 3D steel-framed gravity buildings under fires with a cooling phase. The effect of fire protections and bracing systems on whether, how, and when a gravity building collapses is studied. It is found that whether a building collapses or not depends on the duration of the heating phase, and it may withstand a "short-hot" fire, but collapses under a mild fire or a "long-cool" fire. The collapse time can be conservatively determined by the time when the temperature of steel columns reaches a critical temperature of 550 ℃. It is also found that the application of a higher level of fire protection may prevent the collapse of a building, but may also lead to its collapse in the cooling phase due to the delayed temperature increment in the heated members. The tensile membrane action in a heated slab can be resisted by a tensile ring around its perimeter or by tensile yielding lines extended to the edge of the frame. It is recommended for practical design that hat bracing systems should be arranged on the whole top floor, and a combination of perimeter and internal vertical bracing systems be used to mitigate the fire-induced collapse of gravity buildings. It is also suggested that beam-to-column connections should be designed to resist high tensile forces (up to yielding force) during the cooling phase of a fire.

여성들의 찜질방 이용 현상에 관한 일상 생활 기술적 연구

  • 전정자;유은광
    • Journal of Korean Academy of Nursing
    • /
    • v.27 no.4
    • /
    • pp.961-974
    • /
    • 1997
  • The ZZimzilbang is a room where many women eagerly go due to the special meaning women give to it related to their health. It is a different type of sauna room which maintains low degree of temperature, consisting of an Ondol room(Korean under-floor heating system, hypocaust) built with mineral stone radiating ultrared rays. Even though many women mention that they utilize it for health, there is no precise evidence of the effects on their health. This ethnographic study sought to define the phenomenon from the perspective of the women who experienced the ZZimzilbang. A convenience sample of 27 women was interviewed during a 15 month period from December 1995 to July 1997 in 12 ZZimzilbangs located in Seoul, Korea. The mean ages of the women 57.3 years ; seventeen women were housekeeper and only eight women had job : twenty women were married and three women among them were widows. The main reasons women patronize the place are : for mitigation and healing of physical signs and symptoms : composure ; safe lodging and boarding : control of outward appearance : control of health ; meeting and fellowship with friends : and custom. The outcomes of the utilization of the place were : mitigation of physical signs and symptoms : psychological tranquility : cosmetic and diet ; good use of spare time : and utilization of services provided there. Most women who visited ZZimzilbang for relief of physical signs and symptoms strongly mentioned a correlation to inadequate Sanhujori, the traditional postpartal and postabortal care for woman. Some of specific kinds of services provided in that place were alternative therapy such as acupuncture, negative cupping, finger-pressure, mugwort steam and various kinds of massage including massage of blood vessels that are influenced by Oriental medicine ; health education of breathing such as abdominal breathing or Danjeon(단전호흡) : and selling of many things including health foods, drugs for osteoporosis, and eutrophics. This study suggests that professional caregivers should further study this phenomenon for the development of adequate care of women with a resulting important in their quality of life.

  • PDF

An Analysis of Housing and Domestic Living of Vietnamese Immigrant Workers Who were Living in the Metropolitan Area in Korea (재한(在韓) 베트남인 이주 노동자의 주거 및 주생활 : 우리나라 수도권 지역을 중심으로)

  • Lee, Young-Shim;Choi, Jung-Shin
    • Journal of the Korean Home Economics Association
    • /
    • v.47 no.2
    • /
    • pp.39-53
    • /
    • 2009
  • The purpose of this study was to analyze the state of Vietnamese housing in Korea. Using ethnographic methodologies, it was examined that 22 Vietnamese households in Korea in relation to their usage of housing space. The following conclusion were established; 1). Most of households had kitchen+1 or 2 bedrooms and the majority households preferred separated kitchen and living room areas. 2). Most households had a washing machine in bathroom and they regarded bathtub as not very necessary. They all preferred the bathroom with enough space for using washing machine and hand washing both. 3). Their preferred seating style was using chairs on sleeping as like in Vietnam but they preferred eating without chairs and treated large family and guest without chairs specially. 4). All of them were took their shoes off usually and preferred designated shoes space at the entrance to the house which was not used in Vietnam. 5). A Floor material of all households was vinyl on living room and bedrooms and most of them who had been using tile only in Vietnam preferred vinyl here. 6). All of households had a modified Ondol and most of them who had never been used this before preferred and they regarded as a desirable heating system. 7). They considered the kitchen as the most important housing space and the direction of housing was the one to consider when they built or buy the house.

Manufacturing and Properties of Bi-Sn Impregnated Wood Composites of Juglans nigra (북미산 흑호두나무 Bi-Sn 용융합금 복합체의 제조와 특성)

  • Kang, Seog-Goo;Park, Kye-Shin;Lee, Ho;Seo, In-Soo;Lee, Jong-Shin;Lee, Hwa-Hyoung
    • Journal of the Korea Furniture Society
    • /
    • v.22 no.1
    • /
    • pp.54-62
    • /
    • 2011
  • The metalized wood composites with natural grain of imported Juglans nigra, which was impregnated with low melting alloy were manufactured and evaluated in this study. And the proper manufacturing conditions was also investigated in this study. The low melting alloy with bismuth (Bi) and tin (Sn) which are harmless to humans, was applied to this new composites. The composites showed not only no defects of discoloration, delamination, swelling, and cracking, because of high dimensional stability and low thickness swelling, but also much improved performance such as high bending strength, high hardness, abrasion resistance, high thermal conductivity as floor materials. This study also suggested the proper impregnating condition, such as 10 minutes of the preliminary vacuum time, $186^{\circ}C$ of the heating temperature and 10 minutes of the maintaining pressure time at the pressure of $30kgf/cm^2$. This metalized wood composites showed 7 times higher density than control, great increase in bending strength from $131.8N/mm^2$ to $192.3N/mm^2$, and great increase in hardness from $18.2N/mm^2$ to $90.4N/mm^2$. The composites demonstrated not only high emissivity of 91%, high shilding effectiveness of 92.59∼99.99%, high fire resistance but also great decrease in abrasion depth, water absorption and thickness swelling.

  • PDF