• Title/Summary/Keyword: floor

Search Result 6,097, Processing Time 0.031 seconds

Sex-related and racial variations in orbital floor anatomy

  • Moon, Seung Jin;Lee, Won Jai;Roh, Tai Suk;Baek, Wooyeol
    • Archives of Craniofacial Surgery
    • /
    • v.21 no.4
    • /
    • pp.219-224
    • /
    • 2020
  • Background: Repair of the orbital floor following trauma or tumor removal remains a challenge because of its complex three-dimensional shape. The purpose of the present study is to understand normal orbital floor anatomy by investigating its differences across four groups (Caucasian American and East Asian, males and females) via facial bone computed tomography (CT). Methods: A total of 48 orbits in 24 patients between 20 and 60 years of age were evaluated. Although most patients underwent CT scanning following trauma, the orbital walls were intact in all patients. Linear and angular measurements of the orbital floor were obtained from CT images. Results: Orbital floor width, length, angle between the orbital floor and medial wall, and distance from the inferior orbital rim to the lowest point of the orbital floor did not show a statistically significant difference between groups. Angles made by the infraorbital rim, the lowest point of the floor, and the anterior border of the infraorbital fissure were statistically significantly wider in East Asian females than in male groups. The floor depth in East Asian females was significantly smaller compared to all the other groups. Conclusion: East Asian female population had smaller curvature and depth of an orbital floor than the other groups, which means racial and sex-related differences should be considered in the orbital floor reconstruction.

An Enhanced Floor Field based Pedestrian Simulation Model (개선된 Floor Field 기반 보행 시뮬레이션 모델)

  • Jun, Chul-Min
    • Journal of Korea Spatial Information System Society
    • /
    • v.12 no.1
    • /
    • pp.76-84
    • /
    • 2010
  • Many pedestrian simulation models for micro-scale spaces as building indoor areas have been proposed for the last decade and two models - social force model and floor field model - are getting attention. Among these, CA-based floor field model is viewed more favourable for computer simulations than computationally complex social force model. However, Kirchner's floor field model has limitations in capturing the differences in dynamic values of different agents and this study proposes an enhanced algorithm. This study improved the floor field model in order for an agent to be able to exclude the influences of its own dynamic values by changing the data structure, and, also modified the initial dynamic value problem in order to fit more realistic environment. In the simulations, real 3D building data stored in a spatial DBMS were used considering future integration with indoor localization sensors and real time applications.

Comparative Evaluation of Electric Power and LNG Load according to Floor level of Tower-Type Apartments (탑상형 아파트의 층별 전기와 가스 부하량 비교평가)

  • Kim, Jun Hyun;Choi, Jin Ho;Um, Jung-Sup
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.4
    • /
    • pp.465-475
    • /
    • 2011
  • It is known that energy consumption in bottom floor of typical Korean-style apartment is the highest. Previous studies for energy consumption in accordance with floor level appear to be very limited due to the dependence on single energy variable such as electric power or LNG separately, based on past flat type of apartment. Acknowledging these constraints, an empirical study for a tower type emerged recently as new style of apartment in South Korea was conducted to demonstrate how a comprehensive evaluation for both electric power and LNG consumption can be used to assist in monitoring the total energy consumption in terms of floor specific settings. It was possible to identify that energy consumption in bottom floor is lesser than that of top floor, to the contrary, fact known from previous study. Also electric power consumption in top floor was identified as 15% higher than that of floor in the least. It is anticipated that this integrated utilization of electric power and LNG data would present more scientific and objective evidence for the energy load among floor level of tower type apartment by overcoming serious constraints suffered from the past single variable investigation. Ultimately, the result in this paper could be used as a valuable reference to providing priority for energy saving activities in top floor such as cool roof or green roof.

Vibration Analysis and Evaluation for the Slab of Housing (공동주택 바닥판의 진동해석 및 평가)

  • Park, Kang-Geun;Kim, Yong-Tae;Choi, Young-Wha;Kim, Han-Choul
    • Proceeding of KASS Symposium
    • /
    • 2006.05a
    • /
    • pp.246-255
    • /
    • 2006
  • In these days the floor vibration is beginning to make its appearance of the environmental dispute in apartment building. Standard floor system are suggested for the settlement of this issue by government. The sound of floor impact sound is needed to secure comfortable quality in housing. Also, it is required an accurate analysis and a proper evaluation for floor vibration. Refine model is necessary for the floor system of housing to analyze accurately the floor vibration. But this refine model is not efficient because it is required so much running time for vibration analysis and it is difficult of modeling of standard floor slab. In this paper, new modeling methods of standard floor slab are proposed for the accurate rigidity evaluation. By using the new modeling method, the accurate vibration response can be obtained and can accurately evaluate the rigidity of standard floor system with resilient materials. Therefore the proposed modeling method is of practical use for vibration analysis of floor system of apartment building.

  • PDF

Characteristics of the floor impact sound by water to binder ratio of mortar (마감모르타르 물결합재비에 따른 바닥충격음 특성 변화)

  • Lee, Won-Hak;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.6
    • /
    • pp.671-677
    • /
    • 2021
  • The present study aims to investigate the influence of the water to binder ratio of finishing mortar on the floor impact sound of apartments. For this, same resilient materials Expanded Polystyrene (EPS) with constant dynamic stiffness and different mortar layers with 52 %, 66 % and 72 % water to binder ratio respectively were used to build floating floor structures on which floor impact sounds were measured in standard testing facilities. As a result, it was found that light-weight floor impact sound was transmitted well when the water to binder ratio was 52% due to the high density. In case of heavy-weight floor impact sounds, since water to binder ratio of finishing mortar becomes higher as the weight of upper layer of resilient material lighter, it was shown that the natural frequency of floating floor structure moves to 63 Hz bandwidth which eventually cause a higher sound pressure level of floor impact sound. Thus, effect of water to binder ratio of mortar on the heavy-weight floor impact sounds was investigated.

Improvement of evaluation method for impact sound reduction performance of floor coverings (바닥 상부 마감재의 충격음 저감성능에 대한 평가방법 개선)

  • Jin-Yun Chung;Han-Sol Song;Guk-Gon Song;Yong-Jin Yoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.161-167
    • /
    • 2023
  • Recently, floor impact sound has become a serious social problem in Korea. There is an increasing need to improve floor impact sound performance using floor covering installed on the floor of apartment houses. KS F ISO 717-2 and KS F 2863 require measurement under conditions in which the resilient material is not installed. But most apartment houses in Korea install resilient materials to reduce floor imapct sound. The performance evaluation method of floor covering should provide reduced performance for use by residents of apartment houses with resilient materials. Therefore, this paper proposes a reduction performance evaluation under the conditions in which a resilient material is installed to verify the performance of floor covering.

A Study of the Relationship between Pelvic Floor Muscles and Lumbar Stabilization (골반저근과 요부안정화의 상관관계에 관한 고찰)

  • Moon, Ok-Kon;Lee, Sang-Bin
    • Journal of Korean Physical Therapy Science
    • /
    • v.15 no.1
    • /
    • pp.87-95
    • /
    • 2008
  • Pelvic floor muscles positively affect not only urinary incontinence but also lumbar stabilization by generating intra-abdominal pressure through interaction with muscles around the trunk. Especially, contracting pelvic floor muscles consistently and gently at low intensity is one of the most effective methods to separate and contract transverse abdominis which plays an important role in lumbar stabilization. The purpose of this study was to reexamine the importance of pelvic floor muscles which had not been used much in the treatment of lumbago and to introduce pelvic floor muscle exercises that can be utilized in the treatment of lumbago by examining literature on the relationship between pelvic floor muscles and lumbar stabilization. It is expected that this study will help apply lumbar stabilization exercise to patients with lumbago more variously and effectively.

  • PDF

Structural analysis for floor structure of Rolling Stock (철도차량 바닥 구조 해석)

  • Kim, Yong-Tae;Kim, Myeong-Soo;Park, Kyeong-Bong;Park, Jea-Hong
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.61-69
    • /
    • 2011
  • The noise and vibration which are occurred by equipment and rail under the train are directly delivered to passenger and effect on comfort. For this reason, Floating floor structure has been applied to Rolling Sotck for minimizing the noise and vibration. And in respect of Floating floor, the strength is an important design element. Because the train has many heavy equipments and accommodates lots of passenger. At the early design stage of Floating floor, different joint type and thickness of plywood, etc. were applied and some problem happened. To solve the problems and apply to the future projects, the standard model of Floating floor structure was required. To find optimum design and standard model for Floating floor structure of Rolling Stock, the applied Floating floor models were analysed by CAE (computer-aided engineering).

  • PDF

Investigation Research on the Residents Satisfaction Rating to the Floor Impact Sound in Apartment Buildings (공동주택 바닥충격음에 대한 거주자 만족도 조사 연구)

  • Kim, Kyoung-Woo;Choi, Hyun-Jung;Kim, Young-Su;Yang, Kwan-Seop
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.2
    • /
    • pp.179-184
    • /
    • 2010
  • In this study, the satisfaction rating to the floor impact sound was investigated for the residents in the apartment Building where the business scheme had been approved after 2005. The results are compared with existing research. The questionnaire survey was conducted to the 597 residents in 14 apartments complex which were applied with standard floor structure and approval floor structure. Most of respondents(71.1 %) answered that the performance of floor impact sound insulation, in case of standard floor structure, was improved compared to the apartments where they used to live. Comparing with the questionnaire survey result of existing research, the answered ratio of 'less annoyed' and 'less loud' is somewhat increased.

An Analysis of Apartments Floor Plans in Seoul (아파트 단위평면의 공간별 주요계획요소에 관한 연구)

  • Lee, Eun-Min;Lee, Yeun-Sook
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2004.11a
    • /
    • pp.75-80
    • /
    • 2004
  • This study was designed to examine characteristics of apartment floor plans that have been recently available. Content analysis was conducted, and 232 apartment floor plans were examined. This study indicated that the front width and the number of front bays also notably increased. Also, two bathrooms in a unit have been increasing, and three bedrooms were very popular. The conspicuous change of floor plan component is the appearance of entrance lobby. It was noted that dress room and powder room that appeared in a larger unit were adopted in small one. Housing suppliers have continuously attempted to have partial change in unit floor plan to accommodate consumers' diverse needs and lifestyle, Further analysis on our residential culture and continuous study on various development of floor plan types need to be made.

  • PDF