• 제목/요약/키워드: flocculation agent

검색결과 16건 처리시간 0.024초

A SINGLE FLOCCULANT/DUAL FLOCCULATION SYSTEM FOR DEWATERING USING A BRANCHED SELF INVERSING EMULSION FLOCCULANT

  • Bae, Young-Han;Lee, Sung-Sik
    • Environmental Engineering Research
    • /
    • 제11권4호
    • /
    • pp.208-216
    • /
    • 2006
  • In order to create a single flocculant/dual flocculation system, polyacrylamide-co-trimethyl ammonium ethyl acrylate chloride (TAEAC) polymers with varying molecular weights and structures were prepared for use of flocculants. The higher the cationic density of the polymer is higher, the higher was the conversion rate and the ratio of monomer. An acrylamide as nonionic monomer was less reactive than a TAEAC as cationic monomer. The branched polymer which was polymerized with a cross-linking agent, N, N-methylene bis-acrylamide had a higher stability and higher viscosity than a linear polymer but its dewatering efficiency was poor in a single flocculation system. In the case of single flocculant/dual flocculation, the branched polymer has better flocculation efficiency and the water content of the dewatered cakes was lower than the others, as the result of a re-flocculation effect. The optimum conditions for dual flocculation are a sequence in which the $1^{st}$ and $2^{nd}$ dosage are 75% and 25%/total dosage of a single flocculation system. The dewatering efficiency of a dual flocculation system is improved considerably from 10 to 25% under the experimental conditions used herein.

N-propyl-N,N-dimethylethanolamine의 Phantom에서 Laser Induced Fluorescence의 스펙트라에 관한 연구 (A Study on Spectra of Laser Induced Flourescence in Phantom of N-propyl-N,N-dimethylethanolamine)

  • 김기준;이주호;이주엽;성완모
    • 한국응용과학기술학회지
    • /
    • 제32권2호
    • /
    • pp.330-338
    • /
    • 2015
  • N-propyl-N,N-dimethylethanolamine의 산란혼탁매질에서 형광, 산란과 응집의 영향은 파장 과 산란된 형광세기로 나타내는데, laser induced fluorescence(LIF) 분광학에 의한 분자특성으로 나타난다. 산란매질에서 광학적 효과는 광학적 파라미터들(${\mu}_s$, ${\mu}_a$, ${\mu}_t$)에 의해 표현되고 응집은 고-액상 분리 공정에서 중요하게 활용되고 있다. 따라서 입자가 서로 접근될 때 콜로이드 입자들의 상호작용을 LIF와 응집효과로 분석하였다. Monte Carlo simuation과 실험으로 레이저 광원에서 검출기까지 거리의 함수에 의해 농도가 묽어짐에 따라 산란세기가 기하급수적으로 감소함을 알 수 있었다. 이는 유지화학, 생의학, 레이저 의학, 의공학 분야적용에 LIF와 입자이동 현상은 아주 적합한 모델 연구에 큰 도움이 될 것이다.

폐기물 매립지 차수층 누출시 전기영동 복원을 위한 침출수에서의 향상기법 (The Enhanced Electrophoresis Method in Leachate System for Repairing of Leaks in Waste Landfill Geomembrane Liner)

  • 김종윤;한상재;김수삼
    • 대한토목학회논문집
    • /
    • 제30권1C호
    • /
    • pp.7-15
    • /
    • 2010
  • 폐기물 매립지에서 손상된 지오멤브레인 라이너에 의해 지층으로 오염물질의 침투가 유발된 경우, 환경적인 피해를 최소화 하기 위해서는 전기영동기법에 의한 지오멤브레인 라이너의 즉각적인 복구가 필요하다. 하지만 실제 매립장 침출수내에서 전기영동기법 적용시 침출수내 다양한 화학종과 점토입자와의 상호작용으로 인해 점토 입자들의 응집이 촉진되고, 전기영동적 이동보다 중력에 의한 침강거동이 우세하게 나타나며, 결국 실제 매립지 현장에 대한 전기영동기법의 적용상 한계점이 유발되었다. 이에 따라 본 연구에서는 점토입자의 응집을 최대한 방지시켜 전기영동력에 의한 입자의 개별적 이동이 유발될 수 있도록 전기영동 향상기법에 대한 1차원 실내실험을 수행하였다. 그 결과, PAA를 사용할 경우, 점토 끝단에 흡착된 폴리머의 전기적 척력효과로 인해 점토 입자의 분산화 효과가 증대되었다.

세사 투입에 따라 형성된 플럭의 물리적 특성 (Effects of ballasting Agent (Microsand) on Physical Floc Characteristics)

  • 류재나;임윤대;오재일
    • 상하수도학회지
    • /
    • 제24권5호
    • /
    • pp.485-493
    • /
    • 2010
  • Chemical coagulation destabilizes colloidal particles so that particles grow to larger flocs. Solid particles are then removed by solid-liquid separation after typical precipitation. Rapid precipitation enhances the separation by reducing the precipitation time with larger and denser particles. Conventionally, polyelectolyte compounds (polymers) function as a flocculant aid by introducing a interparticle binding, which increases the particle size and density. And more recent ballasted flocculation adds a ballasting agent (microsand) to form denser particles with its high-density(sp gr=2.65). The current research was to evaluate the manner in which ballasted flocs are formed under different injection timings of microsand and to recognize the effects on floc formation. $FeCl_3$ as a coagulant, anionic polymer for a flocculation aid and microsand were used for the floc formation. Floc size (diameter) was widely ranged with the highest mean value when microsand was injected between $FeCl_3$ and polymer. Mean floc density was larger when the floc formed smaller. Settling velocity increased with larger floc size, whilst not significantly affected by the timing of microsand injection. The additional slow mixing on floc formation increased floc size to some extent.

고농도 펄프 슬러리 충전에서 PCC의 거동 (Behavior of PCC During Loading at High Consistency Pulp Slurry)

  • 조병욱;원종명
    • 펄프종이기술
    • /
    • 제43권5호
    • /
    • pp.43-48
    • /
    • 2011
  • Filler loading at thick stock was carried out in order to verify if the dual addition of filler can be used as a means to reduce the detrimental effects of filler on the strength properties of paper. PCC was added to 3.5% pulp slurry blended with HwBKP, BCTMP and SwBKP. Cationic starch was used as a fixing agent. The mixture of PCC and pulp was stirred for 5, 10 and 20min. at 1,000 rpm. The remaining PCC was washed out before handsheet making. PCC particles were flocculated and fixed on the pulp fiber and/or space between fibers. It is expected that the flocculation and inclusion of PCC can be helpful to improve the strength properties of paper due to the reduction of detrimental effect in fiber bonding. The distinct tendency in PCC flocculation and fixing on pulp fiber was not observed by the change of cationic starch dosage and treatment time.

Experimental study on treatment of waste slurry by vacuum preloading with different conditioning agents

  • Wu, Yajun;Jiang, Haibo;Lu, Yitian;Sun, Dean
    • Geomechanics and Engineering
    • /
    • 제17권6호
    • /
    • pp.543-551
    • /
    • 2019
  • In China, serious environmental problems are induced by the extremely soft construction waste slurries in many urban areas, and there is no appropriate method to treat it presently. In this paper, four model tests were conducted to investigate the efficiency of waste slurry treatment by combining three conditioning agents which can change characteristics of the slurries with a traditional vacuum preloading method. The tests of size analysis of particle aggregate were conducted to investigate the influence of different conditioning agents on the size distributions of particle aggregate. During the model test, the discharged water volumes were monitored. The pore-size distribution and void ratio of the waste slurries after the vacuum preloading were measured by mercury intrusion porosimetry (MIP). It is found that 1) During the natural precipitation, volume of water out of the organic agent is higher than that of the mixed agent, but it is smaller than that of the mixed agent in the vacuum preloading stage; 2) the mixed agent has a higher total volume of water out than the organic agent and the inorganic agent after test, while the organic agent and the inorganic agent have little difference with respect to the drainage effect. The results demonstrate that the combination of mixed conditioning agent and vacuum preloading for the solid-liquid separation in waste slurry has a satisfactory effect and can be applied in engineering practice.

Individual and combined effect of Portland cement and chemical agents on unconfined compressive strength for high plasticity clayey soils

  • Yilmaz, Yuksel;Eun, Jongwan;Goren, Aysegul
    • Geomechanics and Engineering
    • /
    • 제16권4호
    • /
    • pp.375-384
    • /
    • 2018
  • Unconfined compressive strength (UCS) of high plasticity clayey soil mixed with 5 and 10 % of Portland cement and four chemical agents such as sodium hexametaphosphate, aluminum sulfate, sodium carbonate, and sodium silicate with 0, 5, 10, and 20% concentrations was comparatively evaluated. The individual and combined effects of the cement and chemical agents on the UCS of the soil mixture were investigated. The strength of the soil-cement mixture generally increases with increasing the cement content. However, if the chemical agent is added to the mixture, the strength of the cement-chemical agent-soil mixture tends to vary depending on the type and the amount of the chemical agent. At low concentrations of 5% of aluminum sulfate and 5% and 10% of sodium carbonate, the average UCS of the cement-chemical agent-soil mixture slightly increased compared to pure clay due to increasing the flocculation of the clay in the mixture. However, at high concentrations (20%) of all chemical agents, the UCS significantly decreased compared to the pure clay and clay-cement mixtures. In the case of high cement content, the rate of UCS reduction is the highest among all cement-chemical agent-soil mixtures, which is more than three times higher in comparison to the soil-chemical agent mixtures without cement. Therefore, in the mixture with high cement (> 10%), the reduction of the USC is very sensitive when the chemical agent is added.

플렉소 인쇄 신문지와 OCC 배합에 따른 ONP 탈묵펄프의 백색도 변화 (Analysis of brightness decrease originated from mixing of flexo printed ONP and OCC in ONP recycling process)

  • 류정용;송봉근
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2011년도 추계학술발표회 논문집
    • /
    • pp.119-123
    • /
    • 2011
  • The application of flexo printed ONP and OCC leads to brightness decrease of deinked stock in ONP recycling system. The largest problems are due to accumulation of flexo ink & introduction of brown fibers. All these are emphasized by variations in the amount of flexo printed ONP and OCC in recovered ONP stock. Most of the brightness problems caused by flexo ink can be helped and solved by applying a proper polyelectrolytes as coagulation agent and flocculation agent. This requires exact evaluation of sedimentation or dissolved air flotation potentials of flexo ink and polyelectrolytes. Effect of bleaching chemical (H2O2) addition level on the increase of brightness of OCC included stock has been investigated by lab scale test.

  • PDF

Effects of Coupling and Dispersion Agents on the Properties of Styrene-Butadiene Rubber/Butadiene Rubber Compounds Reinforced with Different Silica Contents

  • Yang, Jae-Kyoung;Park, Wonhyeong;Ryu, Changseok;Kim, Sun Jung;Kim, Doil;Kim, Jong-Ho;Seo, Gon
    • Elastomers and Composites
    • /
    • 제53권3호
    • /
    • pp.109-123
    • /
    • 2018
  • The effect of the silica content on the state and properties of silica-filled styrene-butadiene rubber/butadiene rubber (SBR/BR) compounds containing coupling and dispersion agents was evaluated by varying the content of silica from 50 to 120 phr. Bis-[(triethoxysilyl)propyl] tetrasulfide (TESPT) and zinc 2-ethylhexanoate (ZEH) were used as the coupling and dispersion agents, respectively. The maximum silica content in the pristine material was 80 phr, which increased to 120 phr upon the addition of TESPT and ZEH. The incorporation of TESPT considerably improved most of the rubber properties due to its coupling action and the suppression of silica flocculation, while further addition of ZEH resulted in additional improvements. The properties of the rubber compounds with different silica contents can be fully explained either by an enhancement of the rubber-silica interactions or by their deterioration due to an excessive amount of silica aggregates.

Roles of Fucoidan, an Anionic Sulfated Polysaccharide on BSA-Stabilized Oil-in-Water Emulsion

  • Kim, Do-Yeong;Shin, Weon-Sun
    • Macromolecular Research
    • /
    • 제17권2호
    • /
    • pp.128-132
    • /
    • 2009
  • Fucoidan, a sulfated polysaccharide derived from brown seaweed, is an important material valued for its various biological functions, including anti-coagulation, anti-aging, and immune system support. In this study, we examined the potential of fucoidan as a novel emulsifying agent in BSA (bovine serum albumin)-stabilized emulsion at a neutral pH. We measured the dispersed oil-droplet size, surface zeta-potential and creaming formation of 0.5 wt% BSA emulsion (20 wt% oil traction) in the absence and presence of fucoidan. The average particle size and zeta-potential value were 625.4 nm and -30.91 mV in only BSA-stabilized emulsion and 745.2 nm and -44.2 mV in 1.0 wt% fucoidan-added BSA emulsion, respectively. This result suggested that some positive charges of the BSA molecules interacted with the negative charges of fucoidan to inhibit the flocculation among the oil droplets. The creaming rate calculated from the backscattering data measured by Turbiscan dramatically decreased in 1.0 wt% fucoidan-added BSA emulsion during storage. Accordingly, the repulsion forces induced among the oil particles coated with 1.0 wt% fucoidan in emulsion solution resulted in significantly increased emulsion stability. The turbidity of the BSA-stabilized emulsion at 500 nm decreased during five days of storage. However, the fucoidan-added BSA emulsion exhibited a higher value of turbidity than the BSA-stabilized emulsion did. In conclusion, an anionic sulfated fucoidan lowered the surface zeta-potential of BSA-coated oil droplets via the electrostatic interaction, and subsequently inhibited the flocculation among the oil droplets, thereby clearly minimizing the creaming and phase separation of the emulsion.