• 제목/요약/키워드: flexural strength ratio

검색결과 887건 처리시간 0.029초

점토 광물 조성이 점토기반 분리막의 곡강도에 미치는 영향 (Effect of Clay-Mineral Composition on Flexural Strength of Clay-based Membranes)

  • 이영일;엄정혜;김영욱;송인혁
    • 한국세라믹학회지
    • /
    • 제51권5호
    • /
    • pp.380-385
    • /
    • 2014
  • Clay-based membranes with submicron pore size were successfully prepared by a simple pressing process using low-cost starting materials(e.g., kaolin (K), bentonite (B), talc (T), and sodium borate). The green bodies were sintered at $1000^{\circ}C$ for 2 h in air. The effect of clay-mineral composition on the flexural strength of clay-based membranes was investigated. The porosity of the clay-based membranes could be controlled within the range of 34 - 42% by adjusting the starting composition. The flexural strength of the low-cost membranes depended on both the porosity and the ${\alpha}$-quartz content. In turn, the porosity and ${\alpha}$-quartz content were affected by the (B+T) /(K+B+T) ratio. The plot of strength relative to this ratio, showed a maximum when the ratio was 0.4. The typical flexural strength of these clay-based membranes (with ratio 0.4) was 28 MPa at 34% porosity.

강섬유 특성이 숏크리트 품질에 미치는 영향 (Quality Evaluation of shotcrete due to Properties of Steel Fiber)

  • 류종현;김동원;전현규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.673-676
    • /
    • 2006
  • Steel FibreReinforced Shotcrete(SFRS) is one of the main tunnel support along with the rock bolt during the excavation and after the completion of the tunnel. In the standard qualification of the SFRS defined by Korea Highway Corporation, 28 day core specimen has to meet the compressive strength of 19.6 MPa and over 90 % fibre contents. Furthermore, for the 28 days brick shaped specimen made by shooting, flexural strength should be over 4.4 MPa and flexural toughness ratio which can be calculated from flexural toughness factor has to meet more than 68% of flexural strength. In shotcrete, accelerating agent is added for the rapid strength development. Silicate and aluminate type agents are known to develop shotcrete strength rapidly, however, has such problem to degrade the middle and long term strength. Hence, using poly carboxylic super plasticizer, it was aimed to enhance the quality of the shotcrete with the lower water-cement ratio and the same level of workability. The present paper shows the part of the field test result and its analysis.

  • PDF

Assessment of flexural and splitting strength of steel fiber reinforced concrete using automated neural network search

  • Zhang, Zhenhao;Paul, Suvash C.;Panda, Biranchi;Huang, Yuhao;Garg, Ankit;Zhang, Yi;Garg, Akhil;Zhang, Wengang
    • Advances in concrete construction
    • /
    • 제10권1호
    • /
    • pp.81-92
    • /
    • 2020
  • Flexural and splitting strength behavior of conventional concrete can significantly be improved by incorporating the fibers in it. A significant number of research studies have been conducted on various types of fibers and their influence on the tensile capacity of concrete. However, as an important property, tensile capacity of fiber reinforced concrete (FRC) is not modelled properly. Therefore, this paper intends to formulate a model based on experiments that show the relationship between the fiber properties such as the aspect ratio (length/diameter), fiber content, compressive strength, flexural strength and splitting strength of FRC. For the purpose of modeling, various FRC mixes only with steel fiber are adopted from the existing research papers. Automated neural network search (ANS) is then developed and used to investigate the effect of input parameters such as fiber content, aspect ratio and compressive strength to the output parameters of flexural and splitting strength of FRC. It is found that the ANS model can be used to predict the flexural and splitting strength of FRC in a sensible precision.

갈고리형 강섬유를 혼입한 보통 및 고강도 콘크리트의 휨강도 평가 (Evaluation of Flexural Strength for Normal and High Strength Concrete with Hooked Steel Fibers)

  • 오영훈
    • 콘크리트학회논문집
    • /
    • 제20권4호
    • /
    • pp.531-539
    • /
    • 2008
  • 본 연구에서는 강섬유보강 고강도콘크리트의 휨강도와 휨인성을 평가하기 위하여 실험을 수행하였으며, 이러한 실험 결과와 기존 연구자들의 실험 결과를 추가하여 강섬유보강 고강도콘크리트의 휨거동 특성을 분석하였다. 고강도 강섬유 콘크리트의 휨거동 특성은 강도와 인성으로 평가할 수 있으며, 이러한 특성은 콘크리트의 압축강도, 강섬유 혼입률 및 형상비, 강섬유계수와 같은 요소에 의해 영향을 받는 것으로 파악되었다. 아울러 기존 연구자에 의해 제안된 휨강도 산정식의 유효성을 평가하였으며, 강섬유 콘크리트의 휨강도는 콘크리트의 압축강도, 강섬유 혼입률 및 형상비, 강섬유계수와 같은 구조변수의 영향을 모두 고려하여 평가하는 것이 합리적이라고 판단되었다. 최종적으로 본 연구에서는 강섬유 혼입에 따른 휨강도의 상승분과 주요 구조변수간의 상관관계를 분석함으로써 보다 합리적인 휨강도 산정식을 제시하였다.

고강도 철근 콘크리트 보의 휨 설계 및 연성능력 (Flexural Design and Ductile Capacity of Reinforced High Strength Concrete Beams)

  • 신성우;유석형;안종문;이광수
    • 콘크리트학회지
    • /
    • 제8권6호
    • /
    • pp.141-149
    • /
    • 1996
  • 동일한 인장철근배근상태($\rho$/$\rho_b$=constant)에서 휨을 받는 고강도 철근 콘크리트 보는 보통강도의 철근 콘크리트보에 비해 더욱 취성적인 거동을 하게 된다. 본 실험결과 연성적인 파괴를 유도하기 위하여 콘크리트의 강도가 830kg/$cm^2$이상일 경우 철근비를 $0.6\rho_b$이하로 배근하여야 할 것으로 나타났다. 또한 콘크리트 강도가 830kg/$cm^2$ 이상일 경우 사각형응력 블록을 사용한 ACI 휨강도식의 안전율이 감소하였으며, 삼각형에 가까운 압축응력 분포를 나타내었다. 이는 콘크리트 강도가 증가할수록 응력-변형률 곡선이 거의 선형적으로 증가하는 재료적 성질에 기인하는 것으로 사료된다.

Post-peak behavior and flexural ductility of doubly reinforced normal- and high-strength concrete beams

  • Pam, H.J.;Kwan, A.K.H.;Ho, J.C.M.
    • Structural Engineering and Mechanics
    • /
    • 제12권5호
    • /
    • pp.459-474
    • /
    • 2001
  • The complete moment-curvature curves of doubly reinforced concrete beams made of normal- or high-strength concrete have been evaluated using a newly developed analytical method that takes into account the stress-path dependence of the constitutive properties of the materials. From the moment-curvature curves and the strain distribution results obtained, the post-peak behavior and flexural ductility of doubly reinforced normal- and high-strength concrete beam sections are studied. It is found that the major factors affecting the flexural ductility of reinforced concrete beam sections are the tension steel ratio, compression steel ratio and concrete grade. Generally, the flexural ductility decreases as the amount of tension reinforcement increases, but increases as the amount of compression reinforcement increases. However, the effect of the concrete grade on flexural ductility is fairly complicated, as will be explained in the paper. Quantitative analysis of such effects has been carried out and a formula for direct evaluation of the flexural ductility of doubly reinforced concrete sections developed. The formula should be useful for the ductility design of doubly reinforced normal- and high-strength concrete beams.

On the Ductility of High-Strength Concrete Beams

  • Jang, Il-Young;Park, Hoon-Gyu;Kim, Sung-Soo;Kim, Jong-Hoe;Kim, Yong-Gon
    • International Journal of Concrete Structures and Materials
    • /
    • 제2권2호
    • /
    • pp.115-122
    • /
    • 2008
  • Ductility is important in the design of reinforced concrete structures. In seismic design of reinforced concrete members, it is necessary to allow for relatively large ductility so that the seismic energy is absorbed to avoid shear failure or significant degradation of strength even after yielding of reinforcing steels in the concrete member occurs. Therefore, prediction of the ductility should be as accurate as possible. The principal aim of this paper is to present the basic data for the ductility evaluation of reinforced high-strength concrete beams. Accordingly, 23 flexural tests were conducted on full-scale structural concrete beam specimens having concrete compressive strength of 40, 60, and 70MPa. The test results were then reviewed in terms of flexural capacity and ductility. The effect of concrete compressive strength, web reinforcement ratio, tension steel ratio, and shear span to beam depth ratio on ductility were investigated experimentally.

Effects of strain hardening of steel reinforcement on flexural strength and ductility of concrete beams

  • Ho, J.C.M.;Au, F.T.K.;Kwan, A.K.H.
    • Structural Engineering and Mechanics
    • /
    • 제19권2호
    • /
    • pp.185-198
    • /
    • 2005
  • In the design of reinforced concrete beams, it is a standard practice to use the yield stress of the steel reinforcement for the evaluation of the flexural strength. However, because of strain hardening, the tensile strength of the steel reinforcement is often substantially higher than the yield stress. Thus, it is a common belief that the actual flexural strength should be higher than the theoretical flexural strength evaluated with strain hardening ignored. The possible increase in flexural strength due to strain hardening is a two-edge sword. In some cases, it may be treated as strength reserve contributing to extra safety. In other cases, it could lead to greater shear demand causing brittle shear failure of the beam or unexpected greater capacity of the beam causing violation of the strong column-weak beam design philosophy. Strain hardening may also have certain effect on the flexural ductility. In this paper, the effects of strain hardening on the post-peak flexural behaviour, particularly the flexural strength and ductility, of reinforced normal- and high-strength concrete beams are studied. The results reveal that the effects of strain hardening could be quite significant when the tension steel ratio is relatively small.

주철근비에 따른 고강도 콘크리트 보의 휨거동 (The Effect of Longitudinal Steel Ratio on Flexural Behavior of Reinforced High Strength Concrete Beams)

  • 김진근;박찬규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 봄 학술발표회 논문집
    • /
    • pp.71-76
    • /
    • 1994
  • Eight singly reinforced high strength concrete beams were tested to investigate their flexural behavior. The variable is tensile steel raio. The test results are presented in terms of load-deformation behavior, ductility indexes, and cracking patterns. The flexural strengths obtained experimentally are compapred to the analytical results, and good agreements are obtained. The flexural design provisions of the ACI Building Code are found to be adequate to predict the strength of reinforced high-strength concrete beams.

  • PDF

An Experimental Study on the Flexural Strength of Fiber Reinforced Concrete Structures

  • Chai, Won-Kyu
    • International Journal of Safety
    • /
    • 제11권2호
    • /
    • pp.26-28
    • /
    • 2012
  • In this thesis, fracture tests were carried out in order to investigate the flexural strength behavior of FRC(fiber reinforced concrete) structures. FRC beams were used in the tests, the initial crack load and the ultimate load of the beams were observed under the static loading. According to the results, the ultimate loads increase with the fiber content, and these tendency is clear in the specimens with large fiber aspect ratio. From the results of the regression analysis, practical formulae for predicting the flexural strength of FRC were suggested.