• Title/Summary/Keyword: flexural failure

Search Result 859, Processing Time 0.021 seconds

An Experimental Study on the Flexural Behavior of RC Beams Strengthened with High-Strength Bars(1) (고장력 인장봉으로 보강된 RC보의 휨거동에 관한 실험적 연구(1))

  • Shin, Kyung-Jae;Kwak, Myong-Keun;Heo, Byung-Wook;Na, Jung-Min;Oh, Young-Suk
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.4 s.94
    • /
    • pp.527-534
    • /
    • 2006
  • This paper outlines a new strengthening technique for concrete beams using externally unbended high-strength bars. The advantages of proposed method lie in speed and simplicity of construction compared to the alternative strengthening method. Externally unbended reinforcement retains many of the advantages over external unbended prestressed tendons. It eliminates time consuming stressing operations. Clearance requirements around anchorages are reduced as access is not required for prestressing jacks. Test results of eight specimens on reinforced concrete beams using different reinforcement materials such as carbon fiber sheet, steel plate and high-tension bar are reported. The beam strengthened by carbon fiber sheet showed a brittle failure mode due to the separation of fiber. As a result of draped profile of external bar, the maximum strength of the beam were increased by up to 212 percent and the deflections were reduced by up to 65 percent. Test results show that the beams reinforced with high-tension bar are superior to reference specimens, especially for the strength and deformation capacity.

Cyclic Behavior of Moment Link Beams (모멘트 링크보의 이력 거동)

  • Kim, Tai-Young;Kim, Sang-Seup;Kim, Young-Ho;Cheong, Hoe-Yong;Kim, Kyu-Suk
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.3
    • /
    • pp.261-269
    • /
    • 2003
  • The length of the links in an eccentrically braced frame will dictate the behavior of the frame. Link length controls the yielding mechanism and the ultimate failure mode. For short links, the links' shear forces reach the plastic shear capacity before the end moments reach the plastic moment capacity, and the links yields in the shear, forming a shear hinges. These links are termed "shear links." For long links, the end moments reach the plastic moment capacity before the links' shear forces reach the plastic shear capacity, forming moment hinges. These links are termed moment links." In long links, flexural yielding dominates the response, and very high bending strains are required at the link ends to produce large link deformations. In a shear links, the shear force is constant along the length of the links, and the inelastic shear strain are is uniformly distributed over the length of the links. This permits the development of large inelastic link deformations without the development of excessively high local strains. However, The use of eccentrically braced steel frames for the purpose of architectural cionsiderations such as openings and doors, areis dictating the use of longer links, though. Little data areis available on the behavior of long links under cyclic loading conditions. In This paper documents the results of an experimental program is that was conducted to assess the response of moment links in eccentrically braced frames. Sixteen specimens awere tested using a cyclic load.

Evaluating Seismic Performance of Steel Welded Moment Connections Fabricated with SN Steel (SN 강재가 사용된 강구조 용접모멘트접합부의 내진성능 평가)

  • Oh, Sang-Hoon;Choi, Young-Jae;Yoon, Sung-Kee;Lee, Dong-Gue
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.3
    • /
    • pp.271-280
    • /
    • 2010
  • This study was programmed to fabricate a beam-to-column connection that is limited to a steel-welded moment connection with full-scale members, using SN steel. A cyclic seismic test was conducted of the nine specimens that were fabricated by choosing the test variable for the weld access hole geometry, connection design method, and RBS. From the test results, failure modes, the moment-drift behavior, and the strain distribution were provided. From the specimen material properties, the beam's nominal plastic flexural capacity and classified qualified connection as a special moment flame were calculated. By analyzing the skeleton part and the baushinger part, a range of strength-raising effects, and deformation ratios were provided, with which the seismic performance of the specimens were evaluated. The test results showed that the specimens eliminated their weld access holes that demonstrated higher seismic performance than the specimens' existing weld access holes, and that the WUF-W connection that was reinforced by the supplemental fillet weld around the shear tap that was fastened by five bolts demonstrated superior seismic performance.

Engineering Properties of Semi-rigid Pavement Material Produced with Sulfur Polymer Emulsion and Reinforcing Fibers (Sulfur Polymer Emulsion 및 보강용 섬유를 활용한 반강성 포장재의 공학적 특성)

  • Lee, Byung-Jae;Seo, Ji-Seok;Noh, Jae-Ho;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.1
    • /
    • pp.119-127
    • /
    • 2014
  • The application of sulfur polymer emulsion (SPE) as an acrylate substitute for semi-rigid pavement grout was evaluated, and the performance improvement by employing PVA fibers were also evaluated. The result indicated that the filling ratio of semi-rigid pavement material decreased as the fiber content increased, but it was measured to be 92~94% in every mixing condition, which satisfies the target performance, 90%. The maximum Marshall stability value of semi-rigid pavement material was measured to be 25.4 kN, which is about 4.7 times higher than the Korean Standard required for semi-rigid pavement material, 5.0 kN. The dynamic stability evaluation of semi-rigid pavement material indicated that the resistance to deformation from the wheel tracking test was improved by an SPE substitution, and in every mixing condition, the deformation converged to a constant value after 45 minutes with the same dynamic stability of 31,500 times/mm. The strain at the flexural failure was about 0.53%, which shows superior rigidity to asphalt pavements. The examination of abrasion resistance and impact resistance showed that the loss ratio was 9.8~6.0% in every mixing condition, which indicates a good abrasion resistance. Also, when fiber content ratio was 0.3%, the impact resistance was 2.82 times higher compared to plain (i.e., when fibers were not added). In the limited range of this study, an SPE substitution ratio of 30% was found to be an optimal level considering the mechanical and durability performance. In addition, it is thought that semi-rigid pavement material with superior performance could be manufactured if fiber content ratio up to 0.3% is applied depending on the purpose of use.

Effects of Transverse Reinforcement on Headed Bars with Large Diameter at Cut-off Points (컷오프 구간에 정착된 대구경 확대머리철근에 대한 횡보강근의 효과)

  • Jung, Hyung-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.82-90
    • /
    • 2018
  • The nuclear structures are composed of large diameter bars over No.36. If the hooked bars are used for anchorage of large diameter bars, too long length of the tail extension of the hook plus bend create congestion and make an element difficult to construct. To address those problems, headed bars were developed. Provisions of ACI 318-08 specify the development length of headed bars and ignore the effect of transverse reinforcement based on the background researches. However, if headed bars are used at the cut-off or lap splice, longitudinal reinforcements, which are deformed in flexural members, induce tensile stress in cover concrete and increase the tensile force in the transverse reinforcement. The object of this research is to evaluate the effects of transverse reinforcement on the anchorage capacity of headed bar so anchorage test with variable of transverse rebar spacing was conducted. Specimens, which can consider the behavior at the cut-off, were tested. Test results show that failure of specimen without transverse reinforcement was sudden and brittle with concrete cover lifted and developed stress of headed bars was less than half of yield strength of headed bars. On the other hand, in the specimen with transverse reinforcement, transverse rebar directly resist the load of free-end so capacity of specimens highly increased.

Analytical Study on Structural Behavior of Surface Damaged Concrete Member by Calcium Leaching Degradation (칼슘 용출 열화에 의해 표면이 손상된 콘크리트 부재의 구조적 거동에 관한 해석적 연구)

  • Choi, Yoon-Suk;Jang, Yong-Hwan;Choi, So-Yeong;Kim, Il-Sun;Yang, Eun-Ik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.22-32
    • /
    • 2014
  • Durability is one of the most important and attractive subjects in concrete research field because not only durability of concrete is reduced by various degradation factors but also its reduction adversely influences the structural performance and service life of concrete structure. For this reason, a considerable amount of papers associated with concrete durability have been published and those researches were mainly focused on the changes of intrinsic properties of concrete due to chemicophysical degradations. However, the relationship between durability of concrete and structural behavior of concrete member has not been well established yet. In this study, calcium leaching degradation, a cause of concrete strength reduction, was dealt with. The experiments of compressive and flexural behavior of degraded concrete member were performed to evaluate the characteristics of structural behavior according to degradation level. Finally, the results from the experiments were compared with those obtained from nonlinear FEM analysis. The results from this study clearly showed that leaching degradation leads to decrease in compressive strength and compressive behavior evolves from brittle to ductile failure pattern during the degradation process. Load capacity and flexible rigidity of the degraded RC member decreased when the degradation level increased, in compressive zone. Additionally, it was found that the values from nonlinear FEM analysis, CDP model in ABAQUS, coincided well with the experimental results.

Structural Performance of RC Slab-Wall Joints Reinforced by Welded Deformed Steel Bar Mats (철근격자망을 사용한 슬래브-벽체 접합부의 구조성능)

  • Park, Seong-Sik;Yoon, Young-Ho;Lee, Bum-Sik
    • Land and Housing Review
    • /
    • v.2 no.1
    • /
    • pp.61-68
    • /
    • 2011
  • In order to clarify the structural performances of Welded Deformed Steel Bar Mats (WDSBM), the research stated includes the tests for standard hook of top bars of slab in concrete slab-wall joints, the tests for embedment length of top bar of slab, and the development strength tests for standard hook. The test results are as follows; (1) For slab-wall joints using WDSBM as reinforcement in slab, if the top bars of WDSBM are spliced by ordinary bars with sufficient development length and size, it is enough for the strength and crack control. (2) When WDSBM of slab is spliced in joint, the strength is increased with the embedment of bars of this WDSBM into wall. Beyond peak strength, however, ductility is diminished to that as no splice due to pull-out failure. (3) For slab-wall system, ultimate strain of concrete for flexural compression zone in lower surface of slab seems much greater than that of normal concrete beam. The reason is that normal concrete beam has the joint with $180^{\circ}$, however slab-wall joint has the $90^{\circ}$ of which concrete can be confined.

Ductility of High-Strength Concrete Columns with High-Strength Lateral Ties (고강도 띠철근으로 구속된 고강도 콘크리트 기둥의 연성)

  • 문호권;이영호;양근혁;정헌수
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.3
    • /
    • pp.261-267
    • /
    • 2001
  • The objective of this experimental study is to find the allowable level of axial load to give the proper flexural ductility according to the yield strength of lateral ties, and the distribution and amount of longitudinal bars used in confined high-strength concrete columns. Twelve concrete columns with a 20 cm square section and 80 cm high were tested under hi-axial loads. It was observed that the ductility tends to be improved at the axial loads not less than 0.4f$\_$ck/A$\_$g/. The utilization of high-strength ties in accordance with the ACI 318-99 can cause the brittle failure due to the wide tie spacing. Under the high level of axial loads not less than 0.4f$\_$ck/A$\_$g/. it is necessary for the buckling prevention of the longitudinal bars and the proper ductility improvement to use the high-strength ties with the consideration of the volumetric ratio and confinement type of the lateral ties, and the distribution of the longitudinal bars.

Behavior of Reinforced Concrete Inclined Column-Beam Joints (철근콘크리트 경사기둥-보 접합부의 거동)

  • Kwon, Goo-Jung;Park, Jong-Wook;Yoon, Seok-Gwang;Kim, Tae-Jin;Lee, Jung-Yoon
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.2
    • /
    • pp.147-156
    • /
    • 2012
  • In recent years, many high-rise buildings have been constructed in irregular structural system with inclined columns, which may have effect on the structural behavior of beam-column joints. Since the external load leads to shear and flexural forces on the inclined columns in different way from those on the conventional vertical columns, failure mode, resistant strength, and ductility capacity of the inclined column-beam joints may be different than those of the perpendicular beam-column joints. In this study, six RC inclined beam-column joint specimens were tested. The main parameter of the specimens was the angle between axes of the column and beam (90, 67.5, and 45 degree). Test results indicated that the structural behavior of conventional perpendicular beam-column joint was different to that of the inclined beam-column joints, due to different loading conditions between inclined and perpendicular beam-column joints. Both upper and lower columns of perpendicular beam-column joints were subjected to compressive force, while the upper and lower columns of the inclined beam-column joints were subjected to tensile and compressive forces, respectively.

New Suggestion of Effective Moment of Inertia for Beams Reinforced with the Deformed GFRP Rebar (이형 GFRP Rebar로 보강된 보의 유효단면이차모멘트 산정식 제안)

  • Sim, Jong-Sung;Oh, Hong-Seob;Ju, Min-Kwan;Lim, Jun-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.2
    • /
    • pp.185-191
    • /
    • 2008
  • To fundamentally solve the problem of deterioration of concrete structures, it has been researched that the high durable concrete structure reinforced with the FRP rebar can be one of major solution to the newly-developed concrete structure. FRP rebar has lots of advantages such as non-corrosive, high performance and light weight against the conventional steel rebar. Among these kinds of FRP rebars, GFRP rebar has usually been considered as the best reinforcement because of its economic point of view. Even though the material capacity of the GFRP rebar was already investigated, there are some problems such as low modulus of elastic that will be cause for degrade of the serviceability of flexural concrete member reinforced with the GFRP rebar. Thus, the deflection characteristics of the GFRP rebar reinforced concrete structure should be considered then investigated. In this study, ACI 440 guideline (2003), ISIS Canada Design Manual (2001) and Toutanji et al. (2000) was considered for predicting the moment of inertia of the concrete beam reinforced with the GFRP rebar. And it was also evaluated that load-deflection relationship had a good accordance with the test and analysis result. In the result of this study, it could be estimated that the load-deflection relationship using the suggested equation of moment of inertia in this study indicated better accordance with the test result than that of the others until failure.