• Title/Summary/Keyword: flattening

Search Result 305, Processing Time 0.029 seconds

Optimization of the Tube Bending Process of Taguchi's Orthogonal Matrix (다구찌 직교배열을 이용한 트레일링 암 튜브 벤딩 공정 변수 최적화)

  • Yin, Z.H.;Chae, M.S.;Moon, K.J.;Kim, Y.S.
    • Transactions of Materials Processing
    • /
    • v.18 no.1
    • /
    • pp.67-72
    • /
    • 2009
  • This paper covers finite element simulations to evaluate tube bending process of auto chassis component i.e. trailing-arm product. The rear of the auto chassis structure is primarily composed of CTBA and trailing-arm. When a car rolls into a corner, the trailing arm reacts to roll in the same degree as the car body. During the bending process of trailing arm the tube undergoes significant deformation. Thus forming defects such as excessive thinning and flattening of the tube will be formed in the outside of the tube. In this paper, we analyzed the effect of process parameters in rotary draw bending process and searched the optimized combination of process parameters using orthogonal arrays method to minimize the forming defects. In this process we analyzed several parameters which are displacement of pressure die, boosting force, initial position of mandrel bar, dimensions of mandrel in regarding to the thinning and flattening of the tube.

Plate Flattening Analysis in Line Heating Process using Bending Strains (굽힘 변형도를 이용한 선상가열 과정의 곡 펴짐 현상에 관한 연구)

  • Park, Jung-Seo;Kim, Jung;Shin, Jong-Gye;Hyun, Chung-Min;Doh, Young-Chil;Ko, Kwang-Hee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.45 no.4
    • /
    • pp.417-425
    • /
    • 2008
  • In the line heating process, only angular distortion whose direction is perpendicular to that of a heating path is expected. However, it is observed that a deformation is induced in the direction of the heating line. Because of this, during forming a saddle type plate we experience unfavorable deformations in the unintended direction. In this paper we discuss the unwanted distortion in the manufacturing process by analyzing intermediate plates of saddle type during fabrication. For this analysis we consider the longitudinal and transversal directions separately and use the bending strain for the analysis.

Condylar bony changes in patients with temporomandibular disorders: a CBCT study

  • Nah, Kyung-Soo
    • Imaging Science in Dentistry
    • /
    • v.42 no.4
    • /
    • pp.249-253
    • /
    • 2012
  • Purpose: Diagnosis of osteoarthritis most commonly depends on clinical and radiographic findings. The present study attempted to observe the bony changes in temporomandibular joint (TMJ) patients from all age groups. Materials and Methods: The first-visit clinical records and cone beam computed tomography (CBCT) data of 440 TMJs from 220 consecutive TMJ patients were reviewed retrospectively. Results: The most frequent condylar bony change observed was sclerosis (133 joints, 30.2%) followed by surface erosion (129 joints, 29.3%), flattening of the articular surface (112 joints, 25.5%), and deviation in form (58 joints, 13.2%), which included 33 TMJs in a cane-shape, 16 with a lateral or medial pole depression, 6 with posterior condylar surface flattening, and 3 with a bifid-shaped condyle. Fifty-three joints (12.0%) showed hypoplastic condyles but only 1 joint showed hyperplasia. Osteophyte was found in 35 joints (8.0%) and subcortical cyst in 24 joints (5.5%), 5 of which had surface erosion as well. One hundred nineteen joints (27.0%) had only one kind of condylar bony change, 66 joints (15.0%) had two, 52 joints (11.8%) had three, 12 joints (5.0%) had four, and 6 joints (1.4%) had five kinds of condylar bony changes at the same time. Eighty-five (65.9%) of 129 joints with surface erosion had pain recorded at the chief complaint. Conclusion: With more widespread use of CBCT, more specific or detailed guidelines for osteoarthritis are needed.

A Study on the Determination of a Practical Ship Hull Form by the Streamline Tracing Method (유선추적(流線追跡)에 의(依)한 실용선형(實用船型) 결정법(決定法)에 관(關)한 연구(硏究))

  • Kyu-Jong,Cho
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.8 no.1
    • /
    • pp.1-16
    • /
    • 1971
  • Ship hulls obtained by the streamline tracing method usually have characteristically drooped keel lines at the bottom, and a flattening of these bottoms would contribute considerably in utilizing these analytically obtainable hull forms in practical usage. In this dissertation, the author deals with a study on the determination of a practical hull form by the streamline tracing method with a particular emphasis on the bottom flattening problem. Investigations are centered around the form and the terms of bottom doublet distribution. Several examples are computed by varying bottom doublet sheet systematically while the main side source distribution is kept the same. The following conclusions are obtained based on those computed results: after the strength of a bottom doublet sheet can be determined more easily and efficiently by employing the concept of a control plane. If the distance from the distributed plane of the bottom doublet sheet to the control plane is defined as the control distance, the strength of the bottom doublet sheet, the flatness of traced lines, and the increment of the beam length ratio by adding the bottom doublet sheet are all related to the control distance by linear equations near the design bottom. It is observed that a better result can be obtained by using a "line-sampling method" for ${\zeta}_K>2T/L$, and a "plane-sampling method" for ${\zeta}_K{\leq}2T/L$, provided that the check points are sampled in the range ${\xi}{\leq}0.7$.

  • PDF

Design and Fabrication of Gain Equalization Filer in Optical WDM Systems Using Fiber Lattice Tapered Methods (WDM용 광섬유 증폭기를 위한 전광섬유형 이득등화 필터 제작)

  • Chang, Jin-Hyeon;Jeon, Byung-Goo;Kim, Jin-Sik
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.8 no.2
    • /
    • pp.90-95
    • /
    • 2009
  • All-optical fiber-type gain flattening filer (GFF) for an EDFA (Erbium doped fiber amplifier) were fabricated by using a FBT (fiber biconical tapered) process and the performance of the GFF was tested and athermal package was proposed. Historically, the chief contributor to gain unevenness has been the EDFA. Due to the inherent gain response of the EDFA's operation, there is always a modest imbalance in the gain applied as a function of wavelength. FBT methods have been used to make fiber type couplers and WDM filter since 1980. Attractivity of this methods was simple, cost effective and thermal stability. Simulation program tool is made to design target GFF profile for this paper. Fiber coupler manufacturing machine is modified for the GFF process. The final GFF is obtained by cascading 4 unit filter that has 6 taper stage. Test result shows 1 dB of wavelength flatness in the C band. Polarization dependent loss is under 0.15dB. The center wavelength variation is below ${\pm}$0.35nm at the temperature range of $20^{\circ}C$ to $70^{\circ}C$.

  • PDF

Design of Brassiere Pattern for Big Size Breast Women -Based on 3D Breast Scanning Data- (유방이 큰 여성을 위한 브래지어 패턴 설계 -3차원 유방 형상 자료를 중심으로-)

  • Han, Chohee;Yi, Kyong-Hwa
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.43 no.2
    • /
    • pp.204-214
    • /
    • 2019
  • A CAD program has recently been introduced that can be directly developed into a three-dimensional human body shape and made into a pattern. It is possible to fabricate a bra that reflects the volume and surface area of the breast; however, it still needs to be verified. This study investigates the average size and shape of 20 big-breasted women and designs a brassiere pattern for women with large breasts using a 3D Flattening function of OptiTex PDS v15.6. In addition, the study verifies the reliability of the proposed method compared to a conventional brassiere pattern. The study results are as follows. First, the three dimensional measurement values were smaller than the direct measurement dimensions when the three dimension measurement dimensions of the subjects were compared with the direct measurement dimensions, the replica measurement dimensions and the three dimensional measurement dimensions. Second, the 3D flattening pattern reflects the actual shape, length, and area of the actual breast when comparing a brassiere pattern using a 3D shape and pattern reflecting the direct measurement.

Positional correction of a 3D position-sensitive virtual Frisch-grid CZT detector for gamma spectroscopy and imaging based on a theoretical assumption

  • Younghak Kim ;Kichang Shin ;Aleksey Bolotnikov;Wonho Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1718-1733
    • /
    • 2023
  • The virtual Frisch-grid method for room-temperature radiation detectors has been widely used because of its simplicity and high performance. Recently, side electrodes were separately attached to each surface of the detectors instead of covering the entire detector surface with a single electrode. The side-electrode structure enables the measurement of the three-dimensional (3D) gamma-ray interaction in the detector. The positional information of the interaction can then be utilized to precisely calibrate the response of the detector for gamma-ray spectroscopy and imaging. In this study, we developed a 3D position-sensitive 5 × 5 × 12 mm3 cadmium-zinc-telluride (CZT) detector and applied a flattening method to correct detector responses. Collimated gamma-rays incident on the surface of the detector were scanned to evaluate the positional accuracy of the detection system. Positional distributions of the radiation interactions with the detector were imaged for quantitative and qualitative evaluation. The energy spectra of various radioisotopes were measured and improved by the detector response calibration according to the calculated positional information. The energy spectra ranged from 59.5 keV (emitted by 241Am) to 1332 keV (emitted by 60Co). The best energy resolution was 1.06% at 662 keV when the CZT detector was voxelized to 20 × 20 × 10.

A Study of volumetric modulated arc therapy for stereotactic body radiation therapy in case of multi-target liver cancer using flattening filter free beam (다중표적 간암의 정위적체부방사선치료에서 무편평화여과기선질 용적변조회전치료의 유용성 평가)

  • Yeom, Misuk;Yoon, Inha;Hong, Donggi;Back, Geummun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.31-43
    • /
    • 2015
  • Purpose : Stereotactic body radiation therapy (SBRT) has proved its efficacy in several patient populations with primary and metastatic limited tumors. Because SBRT prescription is high dose level than Conventional radiation therapy. SBRT plan is necessary for effective Organ at risk (OAR) protection and sufficient Planning target volume (PTV) dose coverage. In particular, multi-target cases may result excessive doses to OAR and hot spot due to dose overlap. This study evaluate usefulness of Volumetric modulated arc therapy (VMAT) in dosimetric and technical considerations using Flattening filter free (FFF) beam. Materials and Methods : The treatment plans for five patients, being treated on TrueBeam STx(Varian$^{TM}$, USA) with VMAT using 10MV FFF beam and Standard conformal radiotherapy (CRT) using 15MV Flattening filter (FF) beam. PTV, liver, duodenum, bowel, spinal cord, esophagus, stomach dose were evaluated using the dose volume histogram(DVH). Conformity index(CI), homogeneity index(HI), Paddick's index(PCI) for the PTV was assessed. Total Monitor unit (MU) and beam on time was assessed. Results : Average value of CI, HI and PCI for PTV was $1.381{\pm}0.028$, $1.096{\pm}0.016$, $0.944{\pm}0.473$ in VMAT and $1.381{\pm}0.042$, $1.136{\pm}0.042$, $1.534{\pm}0.465$ in CRT respectively. OAR dose in CRT plans evaluated 1.8 times higher than VMAT. Total MU in VMAT evaluated 1.3 times increase than CRT. Average beam on time was 6.8 minute in VMAT and 21.3 minute in CRT. Conclusion : VMAT for SBRT in multi-target liver cancer using FFF beam is effective treatment techniqe in dosimetric and technical considerations. VMAT decrease intra-fraction error due to treatment time shortening using high dose rate of FFF beam.

  • PDF

The Correlation between Ultrasonographic Findings of Median Nerve and Clinical Scale and Electrodiagnotic Data in Carpal Tunnel Syndrome (수근관 증후군에서 임상양상척도 및 신경전기진단 결과와 정중신경 초음파 소견의 상관관계)

  • Lee, Gyu-Ho;Kim, Sei-Joo;Yoon, Joon-Shik;Park, Byung-Kyu;Cho, Jung-Mo;Jung, Jin-Seok
    • Annals of Clinical Neurophysiology
    • /
    • v.12 no.2
    • /
    • pp.55-60
    • /
    • 2010
  • Background: The aim of this study is to identify the correlation between ultrasonographic findings of median nerve and clinical scale and electrophysiologic data in carpal tunnel syndrome. Methods: Forty three patients (79 hands) with electrophysiologically confirmed carpal tunnel syndrome were evaluated. Clinical symptoms were examined by Historical-Objective (Hi-Ob) scale. Electrophysiologic data and Padua scale were used for severity of electrophysiology. In ultrasonographic study, cross sectional area and flattening ratio of median nerve were measured at distal wrist crease level (DWC), 1cm proximal to distal wrist crease level, and 1cm distal to distal wrist crease level. The correlation between Hi-Ob scale, electrophysiologic data and ultrasonography was measured with Spearman rank test. Results: The mean Hi-Ob scale was 2.4. Mean Padua scale was 4.0. In ultrasnonographic study, cross sectional area and flattening ratio were $0.112\;cm^2{\pm}0.025$ and $3.0{\pm}0.6$ at 1cm proximal to DWC level, $0.118{\pm}0.026\;cm^2$ and $2.9{\pm}0.4$ at DWC level, and $0.107{\pm}0.032\;cm^2$ and $3.0{\pm}0.4$ at 1 cm distal to DWC level. Hi-Ob scale was not correlated with cross sectional area and flattening ratio of median nerve. Hi-Ob scale was correlated with Padua scale positively (r=0.44) and correlated with amplitudes of CMAP and SNAP, negatively (r=-0.33; r=-0.30). Cross sectional area of median nerve was significantly correlated with Padua scale, amplitudes and latencies of CMAP and amplitudes of SNAP. Conclusions: Ultrasonographic findings of median nerve and electrodiagnostic data had statistically significant correlation. Consequently, ultrasonography could be an adjunctive method in diagnosis of carpal tunnel syndrome.

MR Imaging of Carpal Tunnel Syndrome : The Usefulness of MRI in Treatment Decisions (수근관 증후군의 자기공명 영상 : 치료 결정의 유용성)

  • Lee, Kyu-Yong;Lee, Young Joo;Kim, Seung Hyun;Song, Hyoung Gon;Kim, Juhan
    • Annals of Clinical Neurophysiology
    • /
    • v.4 no.2
    • /
    • pp.114-118
    • /
    • 2002
  • Backgrounds : Carpal tunnel syndrome (CTS) is a common condition that is usually diagnosed by electrophysiologic studies. However, CTS provide limited information to determine the causes of CTS and to choose the treatment method. We evaluated diagnostic sensitivity of MR imaging and treatment decisions by MR imaging in electrodiagnosed CTS. Methods : 14 patients (26 wrists) with electrodiagnosed CTS were studied using MR imaging. In 26 wrists for which axial T1 & T2 weighted images were obtained at 1.5T with a decided wrist coil. Previously described MR imaging of CTS such as increased median nerve signal, flattening of median nerve, reticular bowing, tenosynovitis and space occupying lesions were retrospectively evaluated. Degree of improvement was evaluated by global symptom score (GSS). The GSS rated symptoms from 0 (no symptoms) to 10 (severe) in each of five categories: pain, numbness, paresthesia, weakness/clumsiness, and nocturnal awakening. Subjects' GSS was recorded at baseline, 2 weeks, 1 month, 6 months after treatment. We decided to medical treatment that showed mainly inflammatory sign such as increased median nerve signal, tenosinovitis and to surgical treatment such as space occupying lesion, high canal pressure sign. Results : MR imaging showed that increased median nerve signal were in 20 wrists (77%), flattening of median nerve were in 6 wrists (23%), reticular bowing were in 3 wrists (12%), tenosynovitis were in 8 wrists (32%), decreased canal size in 2 wrists (7.6%), space occupying lesion were in 1 wrist (4%). A good outcome was revealed in 21 wrists by medical treatment that showed mainly increased median nerve signal, tenosynovitis. The mean GSS were 27.7 at baseline, 11.2 at 2 weeks, 11.0 at 6 months in medical treatment group. Another 5 wrist had surgical treatment shown by ganglion and high canal pressure sign such as median nerve flattening, reticular bowing, decreased canal size: 3 wrists had good prognosis, but 2 wrists (one patient) had no significant improvement due to small carpal tunnel size. Conclusions : Our results are in agreement with most previously described MR imaging signs of CTS. MR imaging plays an important role in several cases and especially in the assessment of failure of surgical treatment. Knowledge of MR findings may permit more rational choice of treatment.

  • PDF