• Title/Summary/Keyword: flat plate collector

Search Result 94, Processing Time 0.029 seconds

A Study on the liquid Type Solar Heating System (액체식 태양열난방계통에 관한 연구)

  • Nam, Pyong-Woo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.8 no.4
    • /
    • pp.221-236
    • /
    • 1979
  • The three years Performance of a liquid type solar heating system has been determined for a system which has been determined for a system which has been operating continuously since 1976 in Seoul with no serious maintenance. A flat plate collector is used to transform incident solar radiation into thermal energy. This energy is stored if the form of sensible energy and used as needed to supply the space heating loads. An electric auxiliary heaters are provided to supply energy for space heating load when the energy in the storage tank is depleted. The ratio of useful collected solar heat divided by the total solar radiation on the collector was obtained about 84 per cent. It is also obtained the relation between ratio of solar collector area to the heating area and the ratio of useful collected solar energy to the heating load for the useful design data. A comparison between the measured and simulated results with the solar space heating system is described. Hour by hour simulation is made on unsteady state basis using the system parameters and meteorological data at the experiment site. The result of comparison turned out satisfactory for the solar heating system, though the simulation was formed somewhat higher than by experimental.

  • PDF

Drying of Rough Rice by Solar Collectors (태양(太陽) 열(熱 )집열기(集熱機)를 이용(利用)한 벼의 건조(乾燥)에 관(關)한 연구(硏究))

  • Chang, Kyu-Seob;Kim, Man-Soo;Kim, Dong-Man
    • Korean Journal of Food Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.264-272
    • /
    • 1979
  • The flat-plate and tubular soar collectors were designed and constructed for drying the rough rice, and the performance of the collectors and drying effect were investigated when rough rice was packed in grain bin connected to collectors. Average-monthly radiation on a horizontal surface based on bright sunshine in Daejeon area during 1978 was the highest as $16,814\;KJ/m^2{\cdot}day$ in May and the lowest as $4,254\;KJ/m^2{\cdot}day$ in December, and significane was not recognized between the calculated and recorded values. The thermal effciency of collectors were increased as radiation increased during drying period and the average thermal effciency of flat-plate and tubular collectors in 11 to 12 o'clock a.m were 28.12 and 16.75%, respectively. The average inlet temperature of grain bin at 12 o'clock was shown as 20.02 at control 40.5 at grain bin connected to tubular collector and $55.1^{\circ}C$ at grain bin connected to flat-plate collector. In 25 cm rough rice depth in grain bin, tim taken for drying from initial moisture content at 27.4 to decrease upto 17.0% (14.5 % on wet basis) were 32 in control, 18 in grain bin connected to tubular collector and 11 hrs to flat-plate collector, and grain depth influenced drying rate remarkably. In the view point of drying characteristics, drying pattern showed initially falling-rate to constant-rate period finally.

  • PDF

Performance of Natural Circulation Hot Water System with Flat-Plate Solar Collectors (평만형 태양열 집열기 를 설치한 자연 순환식 급탕시스템 의 성능 에 관한 연구)

  • 윤석범;전문헌
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.5
    • /
    • pp.579-589
    • /
    • 1985
  • The storage tank of the natural-circulation-solar-hot-water system equipped with flat-plate solar collectors is located at higher elevation than the solar collectors. Therefore, the heat loss from the system due to a reversed flow during the night-time is an important factor as well as the day-time thermal performance of the system. The thermal performance of the natural-circulation-solar-hot-water system with flat-plate solar collectors during the day-time depends mainly on the heat collecting efficiency of the solar collectors, whereas its thermal performance during the night-time depends on the system configuration , such as the elevation of the water storage tank with respect to the solar collectors and the piping connections between the storage tank and the solar collectors, as well as thermo-physical properties of the circulating fluid. In the present work, a computer program has been developed to simulate a typical natural-circulation-solar-hot-water-system, and a series of simulation tests have been carried out with the computer program to examine the thermal performance of the system during the day-time as well as the hight-time. In addition , a series of experiment have been conducted under a real sun condition using a natural-circulation-solar-hot-water-system constructed and installed at the KAIST building to compare with the results obtained from computer simulations.

The Performance and Efficiency Analysis of PVT system : A Review (선행 연구된 태양광열 복합 시스템의 문헌 검토를 통한 성능 및 효율분석)

  • Euh, Seung-Hee;Kim, Dae-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.57-66
    • /
    • 2011
  • A Photovoltaic/Thermal(PVT) solar system consists of PV module and thermal absorber plate which convert the absorbed solar radiation into electricity and heat. Meaningful researches and development (R&D) on the PVT technologies have been performed since the 1970s. This paper presents a review of the previous works covering the various types of PVT and their performance analysis in terms of electrical and thermal efficiency. This review compares electrical and thermal efficiency of the different types of PVT collectors and analyzes the parameters affecting PVT performance. Based on the literature review, box channel type PVT with unglazed, or flat plate PVT with glazed have the highest efficiency among them. From the literature review, R&D should be carried out aiming at improving their overall electrical and thermal efficiency, cutting down the cost, and making them more competitive in the energy consumption market.

The Performance and Efficiency Analysis of PVT system : A Review (선행 연구된 태양광열 복합 시스템의 문헌 검토를 통한 성능 및 효율분석)

  • Euh, Seung-Hee;Kim, Dae-Hyun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.250-255
    • /
    • 2011
  • A Photovoltaic/Thermal(PVT) solar system consists of PV module and thermal absorber plate which convert the absorbed solar radiation into electricity and heat. Meaningful researches and development (R&D) on the PVT technologies have been performed since the 1970s. This paper presents a review of the previous works covering the various types of PVT and their performance analysis in terms of electrical and thermal efficiency. This review compares electrical and thermal efficiency of the different types of PVT collectors and analyzes the parameters affecting PVT performance. Based on the literature review, box charmel type PVT with unglazed, or flat plate PVT with glazed have the highest efficiency among them. From the literature review, R&D should be carried out aiming at improving their overall electrical and thermal efficiency and cutting down the cost, making them more competitive in the energy consumption market.

  • PDF

Analysis of Operating Characteristics of Large-scale Solar Thermal System Using Two Types of Collectors (두 종류 태양열 집열기를 이용하는 대규모 태양열 시스템의 동작특성 분석)

  • Lee, Dong-Won;Heo, Jae-Heok;Kim, Min-Hwi
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.2
    • /
    • pp.67-75
    • /
    • 2017
  • We have investigated the operating characteristics of $1,600m^2$ large-scale solar thermal system installed in an eco-friendly energy town in Chungbuk Innovation City. The operation criteria of the collecting pump and storage pump were different from the existing standard, and it was confirmed that each pump works well according to the changed criteria. Based on the data of the representative day, the daily collecting heat (efficiency) and the production (storing) heat (efficiency) were estimated. It was confirmed that the daily collecting heat (efficiency) of the flat plate type was higher than that of the evacuated tube type, but the useful heat production was more in evacuated tube type collector.

Distribution and Variation Characteristic of Solar Radiation Resources in Korea (국내 태양복사 분포 및 변화특성)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heak
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.200.1-200.1
    • /
    • 2010
  • Solar energy is one of the most promising energy resources in the future. For the application and dissemination of solar energy technologies in various fields, reliable data sets of solar irradiation are needed for engineers, researchers, businessmen, and policy makers. Global horizontal solar radiation is needed for the use of flat plate collector, solar domestic hot water system, photovoltaic devices and passive systems like green house. In many countries, solar radiation data accumulated for more then 40 or 50 years and typical weather data are published with average of more then 30 years. In Korea, those global total radiations are measured for about 30 years. With the connections of computer network, measured data could be transmitted to the central control system at key station through Ethernet lines. The data acquisition systems are connected to be automatically controlled by the monitoring network. Global horizontal solar radiation data 16 locations were measured and averaged from 1982 to 2008.

  • PDF

A Study on Design and Performance of a Heat pipe for the application to Solar collector (태양열 집열기용 열파이프의 구조와 작동 특성에 관한 연구)

  • 임광빈;김철주;박이동;황영규;강환국
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1993.05a
    • /
    • pp.70-78
    • /
    • 1993
  • Heat pipes, applied to flat plate solar collectors, have a long and slender configuration with relatively low heat flux on the evaporator. Such a heat pipe has a tendency to build-up a liquid pool at the lower half of evaporator zone, and at this pool occurs such complicated phenomena of evaporation and fluid dynamics as superheat, sudden generation of bubble, its likely explosive growth process and flooding etc. In the present study, we tried to solve those problems by means of adjusting the two principle design parameters, liquid fill charge and wick length, using 4 heat pipes and 3 thermosyphons, with different values of parameter respectively. The corresponding results can be summarized as followings, - The thermal conductance of heat pipes was largely improved by el eliminating wick from adiabatic and condenser zone. - But on evaporator zone wick is inevitable to reduce behavior of the build -up of liquid pool , where arise diverse internal complex phenomena. - The liquid fill charge should have to be increased by 10∼20% more than the quantity to saturate the wick.

  • PDF

Heat Transfer in a Horizontal Mantle Heat Exchanger for a Thermosyphon-driven Flat Plate Collector (자연대류형 태양열 온수기용 맨틀 축열조의 열전달 현상에 관한 연구)

  • Cho, H.J.;Seo, T.B.;Kang, Y.H.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.3
    • /
    • pp.43-50
    • /
    • 2001
  • A horizontal mantle heat exchanger for a thermosyphon-driven SDHW(solar domestic hot water) was numerically simulated and fluid flow and heat transfer in the annulus of the mantle heat exchanger were quantitatively investigated. The Reynolds number, the location of the inlet, and the gap of the annulus were selected as the important design variables. The effects of the design variables on the heat transfer characteristics were thoroughly studied. Based on the numerical results, a correlation for predicting the heat transfer coefficient was suggested as the conclusion of this study.

  • PDF

Development of f-chart for the Design of Solar Heating Systems (태양열난방장치 설계를 위한 f-chart 개발)

  • Song Dal-Sun;Yoo Seong-Yeon
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.15 no.3
    • /
    • pp.292-298
    • /
    • 1986
  • The new f-chart capable of estimating long-term thermal performance of solar space and water heating systems was developed. The system comprise a flat plate solar collector, heat exchanger, storage tank filled with water, auxiliary fuel fired heater, and a house structure. The information obtained from many simulations of solar heating systems has been used to develop this f-chart. Actual hourly meteorological data collected in Seoul, Daejeon, Kwangju and Daegu, Korea from 1979 to 1983 have been utilized in these simulations. The new f-equation is as follows: $$f=1.034Y_{-}0.0968X_{-}0.2235Y^2+0.0043X^2+0.0144Y^3$$. The system performance estimates obtained from the developed f-chart are in close agreement with the results of experiment.

  • PDF