Digital Tomosynthesis using a Flat-panel Detector based Micro-CT

  • Mandai, Koushik Kanti;Choi, Jeong-Min;Cho, Min-Hyoung;Lee, Soo-Yeol
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권5호
    • /
    • pp.364-370
    • /
    • 2008
  • Recent development in large area flat-panel x-ray detector technology enables clinical application of digital tomosyntesis. Unlike conventional motion tomography using x-ray films, flat-panel x-ray detectors provide projection images in digital formats so that tomographic images can be synthesized in a more flexible way. For the digital tomosynthesis, precise movements of the x-ray source and the x-ray detector with respect to a fulcrum point are necessary. In this study, we apply the digital tomosynthesis technique to the flat-panel detector based micro-CT in which the flat-panel detector and the x-ray source rotate together on a circular arc. The experimental results suggest that flat-panel detector based 3D CTs can be used for digital tomosynthesis in the clinical environment.

비정질 평판형 측정기를 이용한 디지털 방사선 영상의 특징 (Imaging Characteristics of Digital Chest Radiography with an Amorphus Silicon Flat Panel Detectors)

  • 정회원;김정민;정만희;임은경
    • 대한디지털의료영상학회논문지
    • /
    • 제8권1호
    • /
    • pp.27-32
    • /
    • 2006
  • The rapid development in digital acquisition technology in radiography has not been accompanied by information regarding optimum radiolographic technique for use with an amorphus silicon flat panel detector. The purpose of our study was to compared imaging characteristics and image quality of an amorphus silicon flat panel detectors for digital chest radiography. All examinations were performed by using an amorphus silicon flat panel detector. Chest radiographs of an chest phantom were obtained with peak kilovoltage values of 60$\sim$150 kVp. Published data ell the effect of x-ray beam energy on imaging characteristics and image qualify when using an amorphus silicon flat panel detector. It is important that radiographers are aware of optimum kVp selection for an amorphus silicon flat panel detector system, particularly for the commonly performed chest examination.

  • PDF

배관 원둘레 이음 용접부의 디지털 방사선 투과 검사 적용을 위한 커브드 및 평면형 검출기의 영상 비교 (Image Comparison of Curved and Flat Panel Detectors for the Application of Digital Radiography Testing in Pipe Welds)

  • 양진욱;조갑호;남문호
    • 한국방사선학회논문지
    • /
    • 제16권5호
    • /
    • pp.585-594
    • /
    • 2022
  • 현재 주로 사용되고 있는 디지털 방사선 검사용 검출기는 평면형의 구조를 가진 검출기로 이루어져 있어 곡률을 가진 검사 대상물의 디지털 방사선 검사 시 완전한 밀착이 불가능 하였다. 본 연구는 산업현장에서 배관 용접부를 대상으로 한 디지털 방사선 투과 검사 시 디지털 영상의 상질 개선을 위하여 곡률에 밀착이 가능한 커브드 형태의 검출기를 제작하였고, 공칭 두께가 각기 다른 6" 배관을 대상으로 평면형 검출기와 커브드 검출기를 사용한 디지털 방사선 영상을 획득하였다. 실험 결과, 평면형 검출기는 배관과 완전한 밀착이 되지 않아 배관 외곽부와 검출기 사이의 틈이 생기게 되고, 이로 인해 불선명도 차이가 생기면서 디지털 영상의 확산이 발생하는 것을 확인하였다. 반면, 커브드형 검출기는 배관 외곽부와 검출기 사이의 틈을 최소화 하여 평면형 검출기에 비해 디지털 영상의 확산이 적은 것을 확인하였다. 영상의 확신이 클수록 상질의 저하 및 판독의 오류가 발생할 수 있기 때문에 검사 대상물과 밀착이 가능한 검출기의 사용시 기존 평면형 검출기 보다 양질의 영상을 획득 가능할 것으로 사료된다.

평판 디텍터 기반 마이크로 CT시스템을 위한 Ring Artifact 보정 방법 (A Ring Artifact Correction Method for a Flat-panel Detector Based Micro-CT System)

  • 김규원;이수열;조민형
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권6호
    • /
    • pp.476-481
    • /
    • 2009
  • The most troublesome artifacts in micro computed tomography (micro-CT) are ring artifacts. The ring artifacts are caused by non-uniform sensitivity and defective pixels of the x-ray detector. These ring artifacts seriously degrade the quality of CT images. In flat-panel detector based micro-CT systems, the ring artifacts are hardly removed by conventional correction methods of digital radiography, because very small difference of detector pixel signals may make severe ring artifacts. This paper presents a novel method to remove ring artifacts in flat-panel detector based micro-CT systems. First, the bad lines of a sinogram which are caused by defective pixels of the detector are identified, and then, they are corrected using a cubic spline interpolation technique. Finally, a ring artifacts free image is reconstructed from the corrected projections. We applied the method to various kinds of objects and found that the image qualities were much improved.

비정질 평판형 측정기를 이용한 디지털 흉부 방사선 영상에서의 효과적인 관전압 선택 (The Effect of X-ray Tube Potential on the Image Quality of Digital Chest Radiography with an Amorphus Silicon Flat Panel Detectors)

  • 김정민;임은경
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제28권4호
    • /
    • pp.273-277
    • /
    • 2005
  • 디지털 의료 영상의 빠른 발전은 새로운 기술-비정질 평판형 측정기-에 대한 최적의 기술이 동행되지 못했다. 이번 실험으로 비정질 평판형 측정기를 사용한 흉부 방사선 영상의 대한 환자선량과 영상의 화질에 대하여 비교하였다. 모든 실험은 비정질 평판형 측정기를 사용하였다. 흉부 팬텀을 사용한 흉부 방사선영상은 관전압 $60{\sim}150\;kVp$에서 획득하였다. 이번 실험을 통하여 획득된 비정질 평판형 측정기를 사용한 X-선 에너지에 대한 영상의 질과 환자선량에 관련된 정보들을 보고한다. 이 정보는 비정질 평판형 측정기를 사용한 시스템에서 최적의 관전압의 선정에 효과적인 정보를 제공하며, 특히 일반적인 흉부 검사에 적용될 수 있을 것이다.

  • PDF

대면적 X-ray 검출기를 위한 분할 구동 시스템 (Seperate Driving System For Large Area X-ray Detector In Radiology)

  • 이동길;박지군;김대환;남상희;안상호;박효덕
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.388-391
    • /
    • 2003
  • The properties of these detectors can be controlled by electronics and exposure conditions. Flat-panel detectors for digital diagnostic imaging convert incident x-ray images to charge images. Flat panel detectors gain more interest real time medical x-ray imaging. Active area of flat panel detector is $14{\times}17$ inch. Detector is based on a $2560{\times}3072$ away of photoconductor and TFT pixels. X-ray conversion layer is deposited upper TFT array flat panel with a 500m by thermal deposition technology. Thickness uniformity of this layer is made of thickness control technology(5%) of thermal deposition system. Each $139m{\times}139m$ pixel is made of thin film transistor technology, a storage capacitor and charge collection electrode having geometrical fill factor of 86%. Using the separate driving system of two dimensional mosaic modules for large area, that is able to 4.2 second per frame. Imaging performance is suited for digital radiography imaging substitute by conventional radiography film system..

  • PDF

CsI(TI) Indirect Flat Panel Detector의 선질에 따른 물리적 영상 평가 (Performance Characteristic of a CsI(Tl) Flat Panel Detector Radiography System)

  • 정회원;민정환;김정민;박민석;이광용
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권2호
    • /
    • pp.109-117
    • /
    • 2012
  • 간접형 CsI flat-panel detector (FPD)의 해상특성(modulation transfer function, MTF), 잡음특성(Wiener spectrum or noise power spectrum, NPS), 양자검출효율(detective quantum efficiency, DQE)을 측정하고 평가하기 위하여 본 실험을 실시하였다. IEC에서 권고한 실험방법을 따라 RQA3, RQA5, RQA7, RQA9의 방사선 선질을 사용하였다. MTF는 egde법을 사용하였다. Wiener spectrum은 조사 영역내에서 획득한 영상의 푸리에 변화를 통하여 구하였다. DQE는 MTF, WS(NPS), X선 입력 및 입력 광자량을 사용하여 평가하였다. 특성곡선은 RQA3와 RQA5, RQA7, RQA9과는 차이가 발생하였다. MTF는 X선 선질과는 상관없이 일정하였다. WS(NPS)은 X선 양이 증가 할수록 감소하였으며, RQA3, RQA5, RQA7, RQA9순으로 감소하였다. DQE는 1mR에서 가장 우수했으며, RQA3, RQA5, RQA7, RQA9순으로 감소하였다. FPD의 물리적 영상 특성을 입력 선질에 따라 다를 수 있다. 본 연구를 통하여 디지털 방사선 시스템의 바르게 사용하려면 FPD의 물리적 영상 특성을 아는 것이 중요함을 인식하게 되었다.

평판형 디지털 엑스레이 가스 검출기의 엑스선 특성 측정기술에 관한 연구 (X-ray properties measurement of Flat panel Digital X-ray gas detector)

  • 윤민석;조성호;오경민;정숙희;남상희;박지군
    • 한국방사선학회논문지
    • /
    • 제3권1호
    • /
    • pp.17-21
    • /
    • 2009
  • 최근 의료진단 분야와 다른 적용분야를 위해 대면적 매트릭스 구조의 엑스선 영상이 활발하게 연구되어 오고 있다. 본 연구에서는, 의료진단을 위한 새로운 평판형 디지털 엑스선 가스 검출기를 제안하고 그에 따른 특성을 검증하고자 한다. 대기압에 반해 가스를 주입하는 어려움 때문에 챔버 형태의 구조로 만들어 질 뿐, 평판형 디지털 엑스선 가스 검출기는 아직 어디에서도 연구된 바 없다. 이에 본 연구에서는 디스플레이 패널 제작 기술을 이용하여 샘플제작을 성공하였다. 실험적인 측정을 위해 만들어진 샘플은 상판에는 유리기판위에 전극, 절연층, 산화마그네슘 보호막을 형성하였으며, 하판에는 엑스선 형광층과 전극을 형성하였다. 누설전류와 엑스선 민감도를 측정하였으며, 전기장에 대한 민감도의 선형성 측정 등의 전기적 특성평가를 실시하였다. 이에 대한 결과로 안정된 누설전류와 엑스선 민감도를 얻었다. 그리고 조사 선량에 따라 좋은 선형성을 보이는 등 넓은 진단 동적영역을 확인할 수 있었다. 이러한 결과로 평판형 엑스선 가스 검출기의 디지털 엑스선 영상 검출기로의 적용 가능성을 확인 할 수 있었다.

  • PDF

Evaluation of the 256ch Flat Panel PS-PMT on Positioning Image Histogram for PET

  • Orita, Narimichi;Murayama, Hideo;Kawai, Hideyuki;Inadama, Naoko;Umehara, Takaya;Kasahara, Takehiro;Tsuda, Tomoaki
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.324-327
    • /
    • 2002
  • For a next generation PET that realizes high sensitivity and high resolution, we proposed a design of a depth of interaction detector. A unit of the detector is constructed of four stages rectangular blocks of 2 by 2 Gd$_2$SiO$\sub$5/: Ce (GSO) crystal array optically coupled to position sensitive photomultiplier tube (PS-PMT). The 256ch flat panel PS-PMT is under development by Hamamatsu Photonics K.K., JAPAN. It has large cathode area, 51.7 by 51.7 mm$^2$, and the ratio of the effective area to external size is about 90%. The feature will contribute high packing fraction, accordingly high sensitivity. The 256 anodes are arranged in 16 by 16 at intervals of 3.0 mm. So as to evaluate the detector capability for identifying crystal of interaction, we got positioning image histograms with coupling a 16 by 5 array of GSO crystals, 2.9 by 2.9 by 7.5 mm$^3$, to the PS-PMT by irradiating a gamma ray uniformly from a point source. Flat panel PS-PMT is a new promising device for PET. We need to evaluate it if its performance is sufficiency. The performance was compared to the one with a 16ch PS-PMT.

  • PDF

비정질 셀레늄의 누설전류 저감을 위한 다층구조 제작 및 특성 평가 (The Multi-layer Fabrication and Characteristic Performance for Dark Current Reduction of Amorphous Selenium)

  • 박지군;강상식;석대우;이형원;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.849-852
    • /
    • 2002
  • Recently, amorphous selenium is used as x-ray conversion material for flat-panel x-ray detector. In this paper, we investigated the effect of breakdown under high voltage and leakage current in PN-type multi-layer structure based on p-type a-Se and n-type conductive thin film. Experimental results show that the multi-layer based detector reduced leakage current because n-type CeO2 conductive layer prevent from hole injection into a-Se layer from collection electrode, Also, the breakdown voltage was improved by dielectric layer between a-Se and top electrode.

  • PDF