• Title/Summary/Keyword: flashing

검색결과 108건 처리시간 0.025초

An Empirical Correlation for Critical Flow Rates of Subcooled Water Through Short Pipes with Small Diameters

  • Park, Choon-Kyung;Park, Jee-Won;Chung, Moon-Ki;Chun, Moon-Hyun
    • Nuclear Engineering and Technology
    • /
    • 제29권1호
    • /
    • pp.35-44
    • /
    • 1997
  • Critical too-Phase flow rates of subcooled water through Short Pipes (L 140039n) with small diameters (D$\leq$7.15 min) have been experimentally investigated for wide ranges of subcooling (0~199$^{\circ}C$) and pressure (0.5~2.0 MPa). To examine the effects of various parameters (i.e., the location of flashing inception, the degree of subcooling, the stagnation temperature and pressure, and the pipe size) on the critical two-phase flow rates of subcooled water through short pipes with small diameters, a total of 135 runs were made for various combinations of test parameters using four different L/D test sections. Experimental results that show effect of various parameters on subcooled critical two phase flow rates are presented in the form of graphs such as the dimensionless mass flux ( $G^{*}$) versus the dimensionless subcooling ( $T_{sub}$$^{*}$) curve. An empirical correlation expressed in terms of a dimensionless subcooling is also obtained for subcooled two-phase flow rates through present test sections. Comparisons between the mass fluxes calculated by present correlation and a total of 755 selected experimental data points of 9 different investigators show that the agreement is fairly good except for very low subcooling data obtained from small L/D (less than 10) orifices.s.s.s.

  • PDF

CHECWORKS와 ToSPACE 프로그램의 배관감육 해석결과 비교 (Comparison of Wall Thinning Analysis Results between CHECWORKS and ToSPACE)

  • 황경모;윤훈;서혁기
    • Corrosion Science and Technology
    • /
    • 제17권6호
    • /
    • pp.317-323
    • /
    • 2018
  • Assumptions have always been that wall thinning on the secondary side piping in nuclear power plants is mostly caused by Flow-Accelerated Corrosion (FAC). Recent studies have showed that wall thinning on the secondary side piping is caused by Liquid Droplet Impingement Erosion (LDIE), Solid Particle Erosion (SPE), cavitation, and flashing. To manage those aging mechanisms, several software such as CHECWORKS, COMSY, and BRT-CICERO have been used in nuclear power plants. Korean nuclear power plants have been using the CHECWORKS program since 1996 to date. However, many site engineers have experienced a lot of inconveniences and problems in using the CHECWORKS program. In order to work through the inconveniences and to remedy problems, KEPCO-E&C has developed a "3D-based pipe wall thinning management program (ToSPACE)" based on the experience of over 30 years in relation to the pipe wall thinning management. This study compares the results of FAC and LDIE analysis using both the CHECWORKS and ToSPACE programs with respect to validation of the wall thinning analysis results.

오리피스를 이용한 고차압 제어 버터플라이 밸브의 캐비테이션 저감에 관한 연구 (A Study on Reduction of Cavitation with Orifice on High Differential Pressure Control Butterfly Valve)

  • 이상범
    • 한국산업융합학회 논문집
    • /
    • 제25권1호
    • /
    • pp.131-139
    • /
    • 2022
  • The exchange of goods over the sea is a situation in which the amount of trade between countries is gradually increasing. In order to maintain the optimal operating condition, the ship maintains stability and optimal operating conditions by inserting or withdrawing ballast water from the ballast tank according to the loading condition of cargo capacity is also increasing. Control valves play an important role in controlling fluid flow in these pipes. When the flow rate is controlled using a control valve, problems such as cavitation, flashing, and suffocating flow may occur due to high differential pressure, and in particular, damage to valves and pipes due to cavitation is a major problem. Therefore, in this study, the cavitation phenomenon is reduced by installing orifices at the front and rear ends of the high differential pressure control butterfly valve to reduce the sudden pressure drop at the limiting part of the butterfly valve step by step. The flow coefficient according to the shape of the orifice, the degree of cavitation occurrence, and the correlation were analyzed using a CFD(Cumputational Fluid Dynamics), and an optimal orifice design for reducing cavitation is derived.

Experiment investigation on flow characteristics of open natural circulation system

  • Qi, Xiangjie;Zhao, Zichen;Ai, Peng;Chen, Peng;Sun, Zhongning;Meng, Zhaoming
    • Nuclear Engineering and Technology
    • /
    • 제54권5호
    • /
    • pp.1851-1859
    • /
    • 2022
  • Experimental research on flow characteristics of open natural circulation system was performed, to figure out the mechanism of the open natural circulation behaviors. The influence factors, such as the heating power, the inlet subcooled and the level of cooling tank on the flow characteristics of the system were examined. It was shown that within the scope of the experimental conditions, there are five flow types: single-phase stable flow, flash and geyser coexisting unstable flow, flash stable flow, flash unstable flow, and flash and boiling coexisting unstable flow. The geyser flow in flash and geyser coexisting unstable flow is different from classic geysers flow. The flow oscillation period and amplitude of the former are more regular, is a newly discovered flow pattern. By drawing the flow instability boundary diagram and sorting out the flow types, it is found that the two-phase unstable flow is mainly characterized by boiling and flash, which determine the behavior of open natural circulation respectively or jointly. Moreover, compared with full liquid level system, non-full liquid level system is more prone to boiling phenomenon, and the range of heat flux density and undercooling degree corresponding to unstable flow is larger.

Experimental investigation of two-phase natural circulation loop as passive containment cooling system

  • Lim, Sun Taek;Kim, Koung Moon;Kim, Haeseong;Jerng, Dong-Wook;Ahn, Ho Seon
    • Nuclear Engineering and Technology
    • /
    • 제53권12호
    • /
    • pp.3918-3929
    • /
    • 2021
  • In this study, we experimentally investigate of a two-phase natural circulation loop that functions as a passive containment cooling system (PCCS). The experimental apparatus comprises two loops: a hot loop, for simulating containment under severe accidents, and a natural circulation loop, for simulating the PCCS. The experiment is conducted by controlling the pressure and inlet temperature of the hot loop in the range of 0.59-0.69 MPa (abs) and 119.6-158.8 ℃, respectively. The heat balance of the hot loop is established and compared with a natural circulation loop to assess the thermal reliability of the experimental apparatus, and an additional system is installed to measure the vapor mass flow rate. Furthermore, the thermal-hydraulic characteristics are considered in terms of a temperature, mass flow rate, heat transfer coefficient (HTC), etc. The flow rate of the natural circulation loop is induced primarily by flashing, and a distortion is observed in the local HTC because of the fully develop as well as subcooled boiling. As a result, we present the amount of heat capacity that the PCCS can passively remove according to the experimental conditions and compared the heat transfer performance using Chen's and Dittus-Boelter correlation.

감육예측 및 수치해석 기법을 활용한 소구경 탄소강배관 감육영향 분석에 관한 연구 (Technology Based on Wall-Thinning Prediction and Numerical Analysis Techniques for Wall-Thinning Analysis of Small-Bore Carbon Steel Piping)

  • 이대영;황경모;진태은;박원;오동훈
    • 대한기계학회논문집B
    • /
    • 제34권4호
    • /
    • pp.429-435
    • /
    • 2010
  • 국내를 포함한 전 세계 50여개 원전의 발전사업자는 유동가속부식에 의한 탄소강 배관 감육을 관리하기 위하여 CHECWORKS 프로그램을 이용하고 있다. CHECWORKS 프로그램은 대구경 배관에만 적용 가능한 것으로 알려져 있기 때문에 소구경 배관에 대해서는 현장 배관감육 관리 담당자의 경험과 판단에 따라 배관을 관리하고 있다. 이에 따라 본 논문에서는 국내 원전 소구경 배관 4개 라인그룹에 대하여 CHECWORKS 프로그램과 FLUENT 코드를 이용하여 유동가속부식과 유동 특성을 분석하였다. 그 결과 현장 배관감육 관리 담당자의 기술력에 따라 CHEC- WORKS 프로그램도 소구경 배관 감육 관리에 이용할 수 있는 것으로 나타났다.

SR-ARQ를 적용한 VLC 시스템의 성능 분석 (Performance Analysis of the VLC System applying SR-ARQ)

  • 최병곤;이민정;김경석
    • 한국인터넷방송통신학회논문지
    • /
    • 제15권4호
    • /
    • pp.127-134
    • /
    • 2015
  • 가시광 무선통신(Visible Light Communication)은 발광다이오드(LED)가 방출하는 가시광 파장을 이용해 데이터를 주고 받는 기술로써 짧은 시간에 전기에서 빛으로 바꾸는 LED의 깜박임(ON/OFF)을 이용하여 통신을 수행한다. 최근 LED 기술이 발전함에 따라 가시광 무선통신 또한 많은 주목을 받고 있으며 이에 대한 연구가 활발히 진행중이다. 특히 벽을 통과하지 못하는 가시광 특성을 고려한 실내 통신 시스템에 대한 관심이 증가하고 있다. 본 논문에서는 실내 환경의 SISO 가시광 무선통신 시스템에 오류제어 기법인 SR-ARQ를 적용하여 통신 환경을 구축하였고, 4가지의 수신지점 및 NRZ-OOK와 VPPM 변조 방식을 이용하여 수신지점 및 변조 방식에 따른 BER, 전송횟수, Throughput을 통해 통신 성능을 비교 및 분석하였다.

교통운영체계선진화의 탄소감축 효과 연구 (Carbon Reduction Effect of Traffic Operational Methods Itemized in National Project for Advanced Traffic Operation and Management)

  • 김원철;김진태
    • 대한토목학회논문집
    • /
    • 제32권1D호
    • /
    • pp.1-11
    • /
    • 2012
  • 대통령자문 국가경쟁력강화위원회와 경찰은 교통운영체계선진화방안을 통하여 신호교차로에서의 효율적인 운영을 도모하고 있다. 신호교차로의 효율적인 운영으로 정체상황이 개선되는 경우 배기가스 및 탄소배출 감소가 기대되나 지금까지 온실가스 저감효과에 대한 관심이 도로교통 운영부문에서 소외되어 교통운영체계선진화로 인한 탄소배출량 감소 효과가 공학적으로 검토된 바 없다. 본 연구는 교통운영체계선진화방안으로 추진되는 전체 19개 사업수행 항목 중 경찰이 주관하여 추진하는 운영항목으로부터 기대되는 탄소배출량 분석방법 및 연(年) 단위 전국 탄소배출량 저감효과를 제시한다. 분석결과 2010년을 기준으로 우리나라 전체 도로교통 부문에서 탄소배출량을 기준으로 보행자작동신호운영 도입으로 12.31% 감축, 점멸신호운영 도입으로 3.27% 감축, 신호연동 도입으로 2.44% 감축, 직진우선 도입으로 0.97% 감축, 비보호좌회전 도입으로 0.81% 감축, 좌회전감응 도입으로 0.72% 감축 효과가 있는 것으로 분석되었다.

Highly AC Voltage Fluctuation-Resistant LED Driver with Sinusoid-Like Reference

  • Ning, Ning;Tong, Zhenxiao;Yu, Dejun;Wu, Shuangyi;Chen, Wenbin;Feng, Chunyi
    • Journal of Power Electronics
    • /
    • 제14권2호
    • /
    • pp.257-264
    • /
    • 2014
  • A novel converter-free AC LED driver that is highly resistant to the fluctuation of AC voltage is proposed in this study. By removing large passive components, such as the bulky capacitor and the large-value inductor, the integration of the driver circuit is enhanced while the driving current remains stable. The proposed circuit provides LED lamps with a driving current that can follow the sinusoid waveform to obtain a very high power factor (PF) and low total harmonic distortion (THD). The LED input current produced by this driving current is insensitive to fluctuations in the AC voltage. Users will thus not feel that LED lamps are flashing during the fluctuation. Experiment results indicate that the proposed system can obtain PF of 0.999 and THD as low as 3.3% for a five-string 6 W LED load under 220 V at 50 Hz.

공동주택단지 난방시스템들에 대한 경제성 평가 (Economic evaluation on heating systems of apartment complex)

  • 조금남;윤승호;김원배
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.773-783
    • /
    • 1998
  • The heating system for apartment complex may be classified as old systems including central system with steam boiler(S1), gas engine driven heat pump system(S2), system using waste heat(S3) and new systems including mechanical vapor re-compression system with flashing heat exchangers(S4), system using methanol(S5), system using metal hydride (S6). The purpose of the present study is to suggest optimal heating system by technically, economically and environmentally evaluating old and new heating systems of apartment complex from 500 to 3,000 households. Economic evaluation based on the technical evaluation results which estimated heat transfer area of heat exchangers and capacity of equipments was estimated initial investment cost, annual operating cost and relative payback period by considering annual increasing rates of energy cost and interest. Environmental evaluation provided annual generation rate of carbon dioxide. Initial investment cost was cheap in the order of S6, S5, S3, S2, S4, S1, annual operating cost was cheap in the order of S1, S2, S4, S5 and relative payback period was short in the order of S6, S5, S2, S3 and S4. Relative payback period was within 8 years for all scenarios of 3,000 households, and was increased as annual increasing rates of energy cost and interest were increased. As transportation pipe length was increased twice, payback period was increased by 1.4~2.6 time. The effect of temperatures of waste gas and waste water on the relative payback period was small within 0.8 years. The annual generation rate of carbon dioxide was big in the order of S4, S2 and S1. S4 was the most economic system among whole scenarios when S1 was replaced with other scenarios.

  • PDF