• 제목/요약/키워드: flame detection rate

검색결과 36건 처리시간 0.038초

Design and Implementation of Fire Detection System Using New Model Mixing

  • Gao, Gao;Lee, SangHyun
    • International Journal of Advanced Culture Technology
    • /
    • 제9권4호
    • /
    • pp.260-267
    • /
    • 2021
  • In this paper, we intend to use a new mixed model of YoloV5 and DeepSort. For fire detection, we want to increase the accuracy by automatically extracting the characteristics of the flame in the image from the training data and using it. In addition, the high false alarm rate, which is a problem of fire detection, is to be solved by using this new mixed model. To confirm the results of this paper, we tested indoors and outdoors, respectively. Looking at the indoor test results, the accuracy of YoloV5 was 75% at 253Frame and 77% at 527Frame, and the YoloV5+DeepSort model showed the same accuracy at 75% at 253 frames and 77% at 527 frames. However, it was confirmed that the smoke and fire detection errors that appeared in YoloV5 disappeared. In addition, as a result of outdoor testing, the YoloV5 model had an accuracy of 75% in detecting fire, but an error in detecting a human face as smoke appeared. However, as a result of applying the YoloV5+DeepSort model, it appeared the same as YoloV5 with an accuracy of 75%, but it was confirmed that the false positive phenomenon disappeared.

Determination of Cadmium(II) and Copper(II) by Flame Atomic Absorption Spectrometry after Preconcentration on Column with Pulverized Amberlite XAD-4 with Bismuthiol I

  • Park, Dong-Seok;Choi, Hee-Seon
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권8호
    • /
    • pp.1375-1382
    • /
    • 2007
  • A column preconcentration method with pulverized Amberlite XAD-4 loaded with bismuthiol I (BI) has been developed for the determination of trace Cd(II) and Cu(II) in various real samples by flame atomic absorption spectrophotometry. Various experimental conditions, such as the size of XAD-4, adsorption flow rate, amount of bismuthiol I, stirring time for adsorbing bismuthiol I on XAD-4, pH of sample solution, amount of XAD-4- BI, desorption solvent, and desorption flow rate, were optimized. Also, the adsorption capacity and the adsorption rate of Cd(II) and Cu(II) on XAD-4-BI were investigated. The interfering effects of various concomitant ions were investigated, Bi(III), Sn(II) and Fe(III) were found to affect the determination. But the interference by these ions was completely eliminated by adjusting the amount of XAD-4-BI resin to 0.70 g, although the adsorption flow rate was slower. For Cd(II) our proposed technique obtained a dynamic range of 0.5-40 ng mL-1, a correlation coefficient (R2) of 0.9913, and a detection limit of 0.3 ng mL-1. For Cu(II), the corresponding values were 2.0-120 ng mL-1, 0.9921 and 1.02 ng mL-1. To validate this proposed technique, the aqueous samples (stream water, reservoir water, tap water and wastewater), the diluted brass sample and the plastic sample, as real samples, were used. Recovery yields of 91-103% were obtained. These measured data were not different from ICP-MS data at 95% confidence level. Our proposed method was also validated using rice flour CRM (normal, fortified) samples. From the results of our experiment, we found that the technique we present here can be applied to the determination of Cd(II) and Cu(II) in various real samples.

Preconcentration and Determination of Fe(III) from Water and Food Samples by Newly Synthesized Chelating Reagent Impregnated Amberlite XAD-16 Resin

  • Tokahoglu, Serife;Ergun, Hasan;Cukurovah, Alaaddin
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권7호
    • /
    • pp.1976-1980
    • /
    • 2010
  • A simple and reliable method has been developed to selectively separate and concentrate trace amounts of Fe(III) ions from water and food samples by using flame atomic absorption spectrometry. A new reagent, 5-hydroxy-4-ethyl-5,6-di-pyridin-2-yl-4,5-dihydro-2H-[1,2,4] triazine-3-thione, was synthesized and characterized by using FT-IR spectroscopy and elemental analysis. Effects of pH, concentration and volume of elution solution, sample flow rate, sample volume and interfering ions on the recovery of Fe(III) were investigated. The optimum pH was found to be 5. Eluent for quantitative elution was 10 mL of 2 M HCl. The preconcentration factor of the method, detection limit (3s/b, ${\mu}gL^{-1}$) and relative standard deviation values were found to be 25, 4.59 and 1%, respectively. In order to verify the accuracy of the method, two certified reference materials (TMDA 54.4 lake water and SRM 1568a rice flour) were analyzed. The results obtained were in good agreement with the certified values. The method was successfully applied to the determination of Fe(III) ions in water and food samples.

딥런닝 기반의 프레임 유사성을 이용한 화재 오탐 검출 개선 연구 (Fase Positive Fire Detection Improvement Research using the Frame Similarity Principal based on Deep Learning)

  • 이영학;심재창
    • 전기전자학회논문지
    • /
    • 제23권1호
    • /
    • pp.242-248
    • /
    • 2019
  • 화염 및 연기 감지 알고리즘 연구는 다양한 모양, 빠른 확산 및 색상으로 인해 컴퓨터 비전에서 어려운 과제이다. 일반적인 센서 기반 화재 감지 시스템의 성능은 환경 요인(실내 및 화재발생 위치)에 따라 크게 제한된다. 이러한 문제를 해결하기위해 딥러닝 방법을 적용하였으며, 이것은 물체의 형상을 특징으로 추출하므로 비슷한 형상이 프레임내에 존재하면 오탐으로 검출 될 수 있다. 본 연구는 화재 오탐 검출 개선을 위해 딥런닝 사용 전과 후에 프레임 유사성을 이용하여 오탐을 줄이는 새로운 알고리즘을 제안한다. 실험결과 제안된 방법을 적용하여 화재 검출 성능은 유지를 하면서 오탐 부분이 최소 30% 까지 감소하는 결과를 얻을 수 있었다. 제안된 방법의 오탐 검출 성능이 뛰어나다는 것을 확인하였다.

레이저 가열 측정법을 이용한 화염 내 매연 농도 측정 (Measurement of soot concentration in flames using laser-induced incandescence method)

  • 정종수
    • 한국연소학회지
    • /
    • 제1권1호
    • /
    • pp.75-82
    • /
    • 1996
  • Laser induced incandescence, LII, recently developed technique for measuring soot concentration in flames, can overcome most of limitations of conventional laser extinction measurement. In this study, experiments were performed to investigate the effect of laser intensity, detection wavelength, and also laser beam quality on both LII signal at a particular position and peak-to-centerline LII signal ratio. The results of LII signal with increasing laser intensity shows its near-independence of laser intensity once threshold level of laser intensity has been reached. However, this near-independence depends on laser beam quality and the incident optical setup. The peak-to-centerline LII signal ratio slowly but continuously increases with laser power. This fact is due to the dependence of LII signal on particle mean diameter. LII signal is attenuated during it passes through the flame containing soot particles. The attenuation rate is inversely proportional to detection wavelength. In this study, LII signal at 680 nm band is 10% greater than the signal at 400 nm band.

  • PDF

GC/FPD에 의한 천연가스 중 황 함유 부취제의 정량 (Determination of Sulfur-Containing Odorants in Natural Gas by Gas Chromatography/Flame Photometric Detection)

  • 최용욱;김종훈;최건형;신성식
    • 분석과학
    • /
    • 제7권3호
    • /
    • pp.349-359
    • /
    • 1994
  • 천연가스 중의 부취제 농도를 분석하기 위한 기체 크로마토그래피 방법에 대하여 연구하였다. TBM(tertiarybutylmercaptan) 및 THT(tetrahydrothiophene)를 포함한 8종의 부취제를 OV-101 컬럼상에서 거의 완전히 분리하였다. 수소 유속, 공기 유속 및 검출기 온도와 같이 FPD의 응답에 영향을 미치는 몇 가지 상호 관련된 파라미터들의 최적 조건을 구하였다. TBM과 THT의 검정곡선을 투과한 장치를 이용하여 작성하였다. 이러한 분석방법을 천연가스 공급관 내의 혼합 부취제인 TBM과 THT를 정량하는 데 적용하였다. 부취수준과 부취제 농도와의 상관관계를 구하기 위한 냄새 측정기의 유용성에 대하여 알아보았다.

  • PDF

차동식 열감지기 설치기준 비교분석에 관한 연구 (Differential temperature fire detector analysis of comparative study based on sensor installation)

  • 황동환;양광모;강경식
    • 대한안전경영과학회지
    • /
    • 제16권4호
    • /
    • pp.379-389
    • /
    • 2014
  • Fire detectors are designed to minimize loss of life from a fire alarm system as an alarm to help evacuate more quickly until the completion of the evacuation alarm should be continued. the purpose of such alarms in order to achieve the characteristic fire heat release rate reaches a certain level, or when a certain time has elapsed, when the heat detector is to be alarms to answer. Requires a quick response, it is desirable to install the sensor as much as possible, but taking into account the cost of installation problems by engineering approach to minimize the quantity and rapidity of detection capability should be increased. In order to increase the rapidity of fire detectors in a room according to the height of the sensing period is to be maintained the optimum distance of the fire detector detects characteristics should be considered. Differential spot-type heat detectors installed domestic basis, depending on the type of sensor that can detect one sensor area is limited and less than 4m ceiling height regulations and simply double the number in excess of 4m and intended to be installed.

Application of Polyurethane Foam Loaded with a Schiff Base Ligand for Determination of Trace Amounts of Copper in Water Samples by Flame Atomic Absorption Spectroscopy

  • Moftakhar, Mahdieh Koorehpazan;Yaftian, Mohammad Reza;Nahaei, Samaneh;Zamani, Abbas Ali
    • 대한화학회지
    • /
    • 제58권3호
    • /
    • pp.283-288
    • /
    • 2014
  • A column solid phase extraction procedure based on modified polyurethane foam (PUF) by a newly synthesized Schiff base ionophore, named 2,2'-{iminobis[propane-3,1-diylnitrilo(1E)prop-1-yl-1-ylidene]}diphenol, was developed for preconcentration step of trace amounts determination of copper ions in water samples by atomic absorption flame spectroscopy. The influence of parameters on the adsorption process such as sample pH, amount of modified PUF packed in the column, type and volume of stripping reagent and its flow rate were investigated and optimized. Under optimum experimental conditions, the calibration graph was linear in a relatively wide range ($0.005-210{\mu}g/ml$) with a limit of detection $0.002{\mu}g/ml$ of copper. The proposed method allows achieving to a concentration factor of >133. The capacity of a column (1.6 cm i.d.) packed by 6 g of PUF modified by 12 mg of the Schiff base was found to be $247.7({\pm}2.1){\mu}g$ of copper. It was found that the adsorption process was highly selective towards copper ions with respect to some associated metal ions. The presented procedure was successfully applied for determination of copper in some water samples.

A Study on the Distribution Characteristics of Sulfur Compounds in Ambient air using Continuous Monitoring Method in Incheon Area

  • Seo, Seok-Jun;Lim, Yong-Jae;Hong, You-deok;Park, Geon-Young
    • 통합자연과학논문집
    • /
    • 제8권2호
    • /
    • pp.128-134
    • /
    • 2015
  • This paper focuses on the applicability of a continuous monitoring method on trace sulfur compounds in the ambient air by TD and GC/PFPD. The target compounds for monitoring include H2S(hydrogen sulfide), Methyl mercaptan, Dimethyl Sulfide, and Dimethyl disulfide. The result of QA/QC on monitoring instruments satisfies all the standards of Odor Measurement and Analysis Method, showing that the reproductivity of the compounds by concentration is within 10%, linearity is above 0.98 of a correlation efficient, method detection limit is 0.16 ppb by MM standard, and recovery rate is over 70%. Monitoring was conducted for two years from March 2006 to February 2008. As a result of the monitoring, the average concentration of H2S was 0.08 ppb, with the maximum concentration at 16.15 ppb. The result indicates that it is reasonable to do continuous monitoring as there appears a spontaneous event of high concentration by the condition of the site during monitoring odor-causing substances. Therefore, it is suggested that the continuous monitoring method used in this paper is appropriate to identify the characteristics of sudden occurrence and concentration variations of sulfur compounds.

헬륨 가스 플로우와 가스 펄스 젯에서 할로겐족 원소들의 레이저유도 플라즈마 방출 스펙트럼 (Laser-induced plasma emission spectra of halogens in the helium gas flow and pulsed jet)

  • 이용훈;최대웅;공용득;남상호;나창운
    • 분석과학
    • /
    • 제26권4호
    • /
    • pp.235-244
    • /
    • 2013
  • 할로겐족 원소들의 강한 원자 방출선들은 진공자외선 영역에 존재하여, 공기 중에서 레이저 펄스를 시료에 집속하여 플라즈마 방출 스펙트럼을 얻어 원소 분석을 수행하기 매우 어렵다. 또한 근적외선 영역에 할로겐족 원소들의 들뜬 전자 상태들 사이의 전이에 의한 원자 방출선들이 존재하는데, 이들은 스타크 효과에 의한 선폭 넓어짐 현상이 매우 커서, 공기 중에서 원소 분석에 충분한 신호 대 잡음비를 얻기 어렵다. 헬륨 가스 플로우를 이용하여 근적외선 영역의 할로겐족 원소들의 원자 방출선들은 레이저유도 플라즈마로부터 관측하였다. 특히, 804.374 nm와 905.833 nm의 아이오딘 원자 방출선들은 레이저유도 플라즈마에서 처음으로 관찰된 것이다. 헬륨 분위기에서 스타크 효과에 의한 선폭 넓어짐 현상과 연속 배경복사의 세기는 현저히 억제되었다. 헬륨 가스 플로우의 유량에 따른 원자 방출선의 세기, 플라즈마 온도, 전자 밀도의 변화를 조사하였다. 이 방법을 이용하여 고무의 난연제 성분에 포함된 염소와 불소를 레이저유도 플라즈마 분광법을 이용하여 검출하였다. 마지막으로 레이저유도 플라즈마 분광법을 이용하여 할로젠 원소들을 검출하는데 헬륨 가스 소모량을 줄일 수 있는 가스 펄스 젯 장치를 제안한다.