• Title/Summary/Keyword: flame base

검색결과 88건 처리시간 0.026초

화염의 상호작용에 의한 부분 예혼합화염의 화염날림 유속 확대 (Nozzle Configurations for Partially Premixed Interacting Jet Flame to Enhance Blowout Limits)

  • 김진현;이병준
    • 대한기계학회논문집B
    • /
    • 제29권1호
    • /
    • pp.71-79
    • /
    • 2005
  • For the non-premixed interacting jet flames, it has been reported that if eight small nozzles are arranged along the circle of $40{\sim}72$ times the diameter of single jet, the flames are not extinguished even in 200m/s. In this research, experiments were extended to the partially premixed cases to reduce both flame temperature and NOx emission. Nine nozzles were used- eight was evenly located along the perimeter of the imaginary circle and one at the geometric centre. The space between nozzles, S, the equivalence ratio, ${\phi}$, the exit velocity and the role of the jet from the centre nozzle were considered. Normally, flame was lifted and flame base was located inside the imaginary circle made by the nozzle. As nozzles went away from each other, blowout velocity increased and then decreased. The maximum blowout velocity diminished with the addition of air to the fuel stream. When the fuel and/or oxidizer were not fed through the centre nozzle, the maximum blowout velocity obtained by varying S and ${\phi}$ was around 160m/s. Optimum nozzle separation distance at which peak blowout velocity obtained also decreased with ${\phi}$ decrease. Flame base became leaner as approaching to the blowout. It seemed that lots of air was supplied to the flame stabilizing region by the entrainment and partially premixing. To approve this idea and to enhance the blowout velocity, fuel was supplied to the centre region. With the small amount of fuel through the centre nozzle, partially premixed flame could be sustained till sonic velocities. It seemed that the stabilizing mechanism in partially premixed interacting flame was different from that of non-premixed case because one was stabilized by the fuel supply through the centre nozzle but the other destabilized.

음향 가진된 프로판 비예혼합 제트 화염의 부상 거동에 대한 실험적 연구 (An Experimental Study on the Lift-off Behavior of Tone-Excited Propane Non-premixed Jet Flames)

  • 김승곤;김강태;박정
    • 대한기계학회논문집B
    • /
    • 제28권5호
    • /
    • pp.569-579
    • /
    • 2004
  • The lift-off characteristics of lifted laminar propane jet flames highly diluted with nitrogen are investigated introducing acoustic forcing with a fuel tube resonance frequency. A flame stability curve is obtained according to forcing strength and the nozzle exit velocity for N2 diluted flames. Flame lift-off behavior is globally classified into three regimes; 1) a weakly varying partially premixed behavior caused by a collapsible mixing for large forcing strength, 2) a coexistent behavior of the edge flame and a weakly varying partially premixed behavior for moderate forcing strength, and 3) edge flame or triple flame behavior for small forcing. It is shown that the laminar lifted flame with forcing affects flame lift-off behavior considerably, and is also clarified that the flame characteristic of flame base is well described with the penetration depth of the degree of mixing, ${\gamma}$$\_$$\delta$/. It is also confirmed that the weakly varying partially premixed flame caused by a collapsible mixing fur large forcing strength behaves as that just near flame blow-out in turbulent lift-off flame.

층류 비예혼합 분류화염에서 음향가진에 의한 유동특성 연구 (A Study of Flow Characteristics by Acoustic Excitation on the Laminar Non-premixed Jet Flame)

  • 오광철;이기만
    • 한국항공우주학회지
    • /
    • 제38권2호
    • /
    • pp.160-168
    • /
    • 2010
  • 공명 주파수의 음파로 가진된 비예혼합 분류화염에서 가진 강도에 대한 영향을 실험적으로 조사하였다. 이를 위해 Mie 산란광 단면법, PLIF, PIV 등 광학적 가시화 방법이 사용되었다. 가진된 분류화염의 부상경로는 연료유량 및 가진 강도에 따라 크게 세 가지 영역으로 구분되는데, 비교적 큰 가진 강도에서 부상될 때 화염기저가 마치 난류화염처럼 부상되는 영역I과 작은 가진 강도에서 쉽게 부상되는 영역II 그리고 이 두 영역들 사이에서 부상된 화염기저가 부분 예혼합의 분젠화염과 같은 형태로 과도기적 영역이 존재함을 알았다. 본 연구에서는 영역I과 II로 구분되는 부상경로 차이에 대한 이해를 높이고자 가진 위상에 따른 노즐과 화염기저간의 유동 혼합과 속도 분포 특성을 아세톤 PLIF와 PIV 시스템을 사용하여 조사하였다.

나노클레이 첨가에 따른 할로겐프리 난연컴파운드의 수직난연 특성 향상에 관한 연구 (A Study on Perpendicular Flame Retardant Characteristic Improvement of Halogen-free Flame Retardant Compounds by Nanoclay Addition)

  • 황찬연;양종석;성백용;김지연;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제28권1호
    • /
    • pp.51-56
    • /
    • 2015
  • The object of this study is to obtain the optimum mix proportion of halogen free compound with flame resistance and, for the purpose, thermal/electrical characteristics test are conducted using compatibilizing agents, flame resistance agents, hydroxide aluminum, sunscreen, antioxidant and silicon oil on the base resin of linear low density polyethylene (LLDPE), Ethylene vinyl acetate copolymer (EVA). Existing compound method accompanies many requirements to be satisfied including a lot of addition of flame resistance agents, prohibition of impact on mixing capability with base and property and etc. In this study, different from the existing method, the optimum mix proportion is determined and experimented by adding nano clay. Oxygen index test shows no difference between specimens while T-6, T-9 shows oxygen index of 29[%] and 26[%], respectively. This is concluded that hydroxide aluminum, which is a flame resistance agent, leads low oxygen index. From UL94-V vertical flame resistance test, the combustion behavior is determined as V-0, Fail based on UL94-V decision criteria. Viscometry shows low measurements in specimens with separate addition of compatibilizing agents or nano clay. Volume resistivity test shows low measurement mainly in specimens without compatibilizing agents. Therefore, with the flame resistance compound shows better performance for thermal/electrical property and the optimum mix proportion are achieved among many existing materials.

다수 난류 비예혼합 화염의 상호작용에 관한 연구 (The Stability of Turbulent Interacting Flames)

  • 김진선;이병준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.453-458
    • /
    • 2001
  • The stability of turbulent nonpremixed interacting flames is investigated in terms of nozzle configuration shapes which depend on the existence of the center nozzles. Six nozzle arrangements which are cross 4, 5, 8, 9, square 8 and circular 8 nozzles are used for the experiment. Those are arranged to see the effect of the center nozzle out of multi-nozzle. There are many parameters that affect flame stability in multi-nozzle flame such as nozzle separation distance, fuel flowrates and nozzle configuration, but the most important factor is the existence of nozzles in the center area from the nozzle arrangement. As the number of nozzle in the area is reduced, more air can be entrained into the center of flame base and then tag flame is formed. In the case of circular 8 nozzles, blowout flowrates are above 5.4 times compared with that of single equivalent area nozzle.

  • PDF

Pool fire의 기본적 특성에 관하여 (On Basic Characteristics of A Pool Fire)

  • 김명배
    • 한국화재소방학회논문지
    • /
    • 제11권1호
    • /
    • pp.55-64
    • /
    • 1997
  • Pool fire는 본격적인 화재연구의 시작과 더불어 그 구조 및 특성에 대한 연구가 지속적으로 수행되어 왔다. Pool fire는 복잡하고 취급하기 어려운 화재의 제문제들을 비교적 간단하게 다룰수 있게 하면서도 현실과 괴리되지 않는 형태를 가지는 가장 기본적인 형태의 화재로, 학문적 측면뿐 아니라 응용측면에서도 매우 유용한 결과 및 단서를 제공하여 왔다. 따라서, 본고에서는 pool fire의 특성을 화염기저(flame base)부근과 플륨(plume)부근으로 나누어 그 동안 발표되었던 연구결과를 정리하고, 화재 시뮬레이션을 위한 zone 모델기법의 가장 중요한 부분의 하나인 연기량 산정과 플륨해석이 어떤 형태로 연결되는 지를 설명하고자 한다.

  • PDF

자열증발된 액체연료를 적용한 원통형 예혼합 연소기의 연소특성 (Combustion Characteristics of Cylindrical Premixed Combustor using Liquid Fuel by Self Evaporation)

  • 이필형;송기종;황상순
    • 한국연소학회지
    • /
    • 제21권3호
    • /
    • pp.7-15
    • /
    • 2016
  • The fuel in conventional liquid fuel combustor is atomized by spray method for high efficiency and low emissions. To improve the overall fuel efficiency and lower pollutant emissions in liquid fuel combustion systems, the effective spatial and temporal separation of droplet evaporation from normal spray process is needed. In this paper, the recuperation of high temperature burnt gas for fuel evaporation was proposed to develop a cylindrical premixed combustor. The recuperation process using U shaped tube is effective to evaporate the liquid fuel. The results show that the flame mode is changed into red radiation flame, blue flame and lift off flame with decreasing equivalence ratio as gas fuel combustion mode. In particular, the blue flame is found to be very stable at heating load 9.2 kW and equivalence ratio 0.731. NOx was measured blow 105 ppm ($O_2$ zero base) from equivalence ratio 0.705 to 0.835. CO which is a very important emission index in liquid fuel combustor was observed below 5 ppm ($O_2$ zero base) under the same equivalence region.

부상된 수소 난류확산화염의 화염구조 (Flame Structure of a Liftoff Non-Premixed Turbulent Hydrogen Jet with Coaxial Air)

  • 오정석;윤영빈
    • 대한기계학회논문집B
    • /
    • 제33권9호
    • /
    • pp.699-708
    • /
    • 2009
  • To understand hydrogen jet liftoff height, the stabilization mechanism of turbulent lifted jet flames under non-premixed conditions was studied. The objectives were to determine flame stability mechanisms, to analyze coexistence of two different flame structure, and to characterize the lifted jet at the flame stabilization point. Hydrogen flow velocity varied from 100 to 300 m/s. Coaxial air velocity was changed from 12 to 20 m/s. Simultaneous velocity field and reaction zone measurements used, PIV/OH PLIF techniques with Nd:YAG lasers and CCD/ICCD cameras. Liftoff height decreased with the increase of fuel velocity. The flame stabilized in a lower velocity region next to the faster fuel jet due to the mixing effects of the coaxial air flow. The flame stabilization was related to turbulent intensity and strain rate assuming that combustion occurs where local flow velocity and turbulent flame propagation velocity are balanced. At the flame base, two different flame structures were found that was the partial premixed flames and premixed flame.

비예혼합 제트화염에서 고주파수의 노즐 구멍음에 의한 부상화염 혼합성능에 관한 연구 (A Study on the Mixing Capacity of Lifted Flame by the Nozzle Hole-tone of High Frequency in Non-premixed Jet Flames)

  • 조준익;이기만
    • 한국가시화정보학회지
    • /
    • 제9권4호
    • /
    • pp.35-40
    • /
    • 2011
  • An experimental investigation of the characteristic of non-premixed lifted flames with nozzle hole-tone of high-frequency has been performed. Before the fuel was supplied to nozzle, the fuel was supplied through a burner cavity which was located under the nozzle. The fuel passed through the excitation cavity under the influence of the high-frequency affects the lifted flame characteristics. The measurements were performed in flow range that occurs lifted flame and blow out. When the high-frequency is generated from burner cavity, the lifted length became shorter, and noise reduced comparing to unexcitation case. Additionally, operating flow range was increased and diameter of flame base became smaller with high-frequency effect. Through this experiments, it's ascertained that the high-frequency excitation can be adopted with effective method for flame stability and noise reduction.

질소 희석이 수소 난류확산화염의 화염안정성에 미치는 영향 (The Effect of N2 Dilution on the Flame Stabilization in a Non-Premixed Turbulent H2 Jet with Coaxial Air)

  • 오정석;윤영빈
    • 대한기계학회논문집B
    • /
    • 제33권7호
    • /
    • pp.477-485
    • /
    • 2009
  • The study of nitrogen dilution effect on the flame stability was experimentally investigated in a non-premixed turbulent lifted hydrogen jet with coaxial air. Hydrogen gas was used as a fuel and coaxial air was used to make flame liftoff. Each of hydrogen and air were injected through axisymetric inner and outer nozzles ($d_F=3.65\;mm$ and $d_A=14.1\;mm$). And both fuel jet and coaxial air velocity were fixed as $u_F=200\;m/s$ and $u_A=16\;m/s$, while the mole fraction of nitrogen diluents gas was varied from 0.0 to 0.2 with 0.1 step. For the analysis of flame structure and the flame stabilization mechanism, the simultaneous measurement of PIV/OH PLIF laser diagnostics had been performed. The stabilization point was selected in the most upstream region of the flame base and defined as the point where the turbulent flame propagation velocity was equal to the axial component of local flow velocity. We found that the turbulent flame propagation velocity increased with the decrease of nitrogen mole fraction. We concluded that the turbulent flame propagation velocity was expressed as a function of turbulent intensity and axial strain rate, even though nitrogen diluents mole fraction was changed.