• 제목/요약/키워드: flame arrestor

검색결과 7건 처리시간 0.024초

폭연방지기 스프링의 구조해석에 관한 연구 (A study of Flame Arrestor's Spring Structural Analysis)

  • 팜민억;김부기;김준호;최민선;양창조
    • 해양환경안전학회:학술대회논문집
    • /
    • 해양환경안전학회 2017년도 추계학술발표회
    • /
    • pp.69-69
    • /
    • 2017
  • Flame arrestor as end of line flame arrester for endurance burning prevents a light-back at deflagration and stabilized burning (during and after endurance burning) of potentially explosive vapor-air and gas-air mixtures at the end of vent pipes. In a flame arrestor, spring is an important part. The spring load as well as the spring's elasticity determine when the hood is opened. In addition, the spring have to work in high temperature condition due to gas burning. Therefore, it is necessary to analyze mechanical load and elasticity of spring when gas is burned. Based on the dynamic calculation on working process of a specific flame arrestor, analysis of spring is taken. A three dimensional model for spring burned in flame arrestor by using CFD simulation. Results of the CFD analysis are input in FEM simulation to analyze structure of the spring. The simulation results can predict and estimate the spring's load and elasticity at variation of the spring's deflection. Moreover, the obtained result can provide makers with references to optimize design of spring as well as flame arrestor.

  • PDF

수소 안전밸브용 역화방지기의 성능 평가에 대한 수치해석 연구 (A Numerical Study on the Flame Arrestor for Safety Valve of Hydrogen)

  • 오승준;윤정환;김시범;최정주
    • 한국수소및신에너지학회논문집
    • /
    • 제33권4호
    • /
    • pp.391-399
    • /
    • 2022
  • Hydrogen is one of the energy carriers and has high energy efficiency relative to mass. It is an eco-friendly fuel that makes only water (H2O) as a by-product after use. In order to use hydrogen conveniently and safely, development of production, storage and transfer technologies is required and attempts are being made to apply hydrogen as an energy source in various fields through the development of the technology. For transporting and storing hydrogen include high-pressure hydrogen gas storage, a type of storage technologies consist of cryogenic hydrogen liquid storage, hydrogen storage alloy, chemical storage by adsorbents and high-pressure hydrogen storage containers have been developed in a total of four stages. The biggest issue in charging high-pressure hydrogen gas which is a combustible gas is safety and the backfire prevention device is that prevents external flames from entering the tank and prevents explosion and is essential to use hydrogen safely. This study conducted a numerical analysis to analyze the performance of suppressing flame propagation of 2, 3 inch flame arrestor. As a result, it is determined that, where the flame arrestor is attached, the temperature would be lowered below the temperature of spontaneous combustion of hydrogen to suppress flame propagation.

내부 부상형저장탱크(IFRT) 화재·폭발 예방대책에 관한 연구 (Study of Fire and Explosion Prevention of an Internal Floating Roof Tank)

  • 구채칠;최재욱
    • 한국화재소방학회논문지
    • /
    • 제33권1호
    • /
    • pp.45-49
    • /
    • 2019
  • 본 연구는 옥외저장탱크에서 발생한 화재의 근본적인 원인분석을 통해 저장탱크의 안전을 유지할 목적으로 수행되었다. 옥외저장탱크는 위험물을 장기간 저장하기 위한 고정장치로 탱크본체 및 부속장치로 구성되며, 부속장치는 벤트 시스템, 브레더 밸브, 화염방지기 등으로 구성된다. 화염방지기는 옥외저장탱크의 화재 폭발을 방지하기 위해 필요한 안전장치이다. 하지만 최근 발생한 옥외저장탱크 화재를 계기로 기존에 설치되어 운용중인 옥외저장탱크에 안전성 확보 차원에서 화염방지기를 의무적으로 설치해야 하는지 국내 외 기준을 비교 분석하여 화염방지기 설치가 필요함을 제시하였고, 화염방지기의 성능을 검증할 수 있는 국내기준이 부족하므로 외국 기준을 참고하여 보완할 필요성이 있다.

사고사례 정밀분석을 통한 상압저장탱크의 안전에 관한 연구 (A Study on Safety of Atmospheric Storage Tank through Detailed Analysis of Accident Case)

  • 임지표;박수율
    • 한국안전학회지
    • /
    • 제34권4호
    • /
    • pp.41-48
    • /
    • 2019
  • In October 2018, a large fire occurred after an explosion in an internal floating roof tank (IFRT) that stores gasoline by wind lantern in Goyang city, Gyeonggi-do. Although there was no casualty damage, the fire inside the tank lasted for 17 hours, and caused a great wave socially, and it was a chance to review the safety of the atmospheric storage tank. In this study, the necessity of installing a flame arrester at peripheral vents was examined through the calculation of the size of ventilation pipe and ventilation rate of internal floating roof tanks in terms of the function of the peripheral vent. Next, the necessity of the emergency shut-off valve linked with the high-level alarm to prevent the overflow of the atmospheric storage tank was confirmed by LOPA. Finally, safety measures to prevent overpressure, flame propagation and overflow which cause major accidents in atmospheric storage tank are suggested.

2단 다공성 매체버너에서 열교환기를 모사한 수관 유무에 따른 연소 특성 비교 (Comparison of Combustion Characteristics With and Without Water Tube Simulating Heat Exchanger in Two Sections Porous Media Burner)

  • 이희도;김재현;이기만
    • 한국가스학회지
    • /
    • 제23권5호
    • /
    • pp.24-34
    • /
    • 2019
  • 본 연구에서는 수관식 보일러의 열교환기를 모사하기 위하여 수관의 존재 유무에 따른 화염의 안정화와 연소 특성을 당량비와 유속에 따라 비교하였다. 버너는 화염이 존재하는 SiC foam과 역화 방지를 위한 세라믹 보드, 균일한 유동장을 형성하는 알루미나 볼로 구성되며, 반경 반향의 열 손실을 최소화하기 위하여 단열재로 밀폐되어 있다. 결과적으로 수관이 존재하는 경우 낮은 당량비 구간에서 역화 및 날림 현상의 경계가 넓어지는 것을 안정화 영역에서 확인할 수 있었다. 또한, 수관이 존재하는 경우 NOx 배출량이 수관이 없는 경우보다 증가하는 것을 확인하였다. 이는 수관이 존재함으로써 열 손실을 억제하여 화염의 온도가 증가하는 것으로 판단하였으며, O2 배출량과 화염의 온도를 예측하여 입증하였다.

RF Sputtering으로 제작한 $SiO_2 $$SiO_2/TiN$ 박막의 R-V 특성 (The R-V Characteristics of $SiO_2 $ & $SiO_2/TiN$ Thin Film Fabricated by RF Sputtering)

  • 김창석;하충기;김병인
    • 한국전기전자재료학회논문지
    • /
    • 제11권10호
    • /
    • pp.826-832
    • /
    • 1998
  • In this study the thin films with the structure of Si+SiO$_2$+TiN are made by RF supttering method. TiN, which has small diffusion coefficient and low resistivity, is evaporated between SiO$_2$ and Al layers. It investigates the V-R characteristics depending on the thickness of SiO$_2$ which is used as insulation layer and researches its effects on voltage stability of thin film and varistor. These films show very small resistance valus in negative(-) voltage and large and large value in positive voltage band, and with the increase of voltage, resistance value is rapidly reduced and the satisfactory characteristic of varistor is shown at +1[V]. It is found that resistance value of TiN thin film is small and also TiN thin film has more current than the thin film which is not evaporated by TiN thin film. When Al electrode is evaporated of SiO$_2$ thin film, spiking occurs, but the spiking can be prevented with evaporation of TiN between SiO$_2$ and Al layers and this thin films in made easily because of its good attachment. With the increase of voltage, the resistance is changed into non-linear pattern and the bidirectional varistor characteristic is shown and then its theory can be verified by this experiment. Accordingly, when TiN is evaporated of Si Wafer(n-100), it obtains better voltage-resistance than thin film which is not evaporated and also when varistor character is used electrically to automatic control element such as elimination of flame, power distribution arrestor and constant voltage compensation, satisfactory reproducibilities are expected.

  • PDF