• Title/Summary/Keyword: fixtures

Search Result 384, Processing Time 0.025 seconds

Digital intraoral impression for immediate provisional restoration of maxillary single implant: A case report (구강 내 디지털 인상채득을 통한 상악 전치부 임플란트 즉시 임시 보철 수복 증례)

  • Chang, Yun-Jeong;Kim, Hong-Jun;Song, Mi-Kyoung;Moon, Ji-Eun;Lee, Hal-La;Park, Chan-Ik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.234-243
    • /
    • 2015
  • Developing of digital technique, it is possible to fabricate implant prostheses for edentulous area using intraoral 3-dimentional information throughout implant diagnosis and treatment process. It is being changed that from the method using CAD/CAM, producing prostheses by model scanning after conventional impression and model processing, to the method of fabricating implant provisional restorations and customized abutments by digital impression after connecting digital impression copings (scanbody) and implant fixtures without models. But, this digital method has not been actively used for implant prostheses not yet. Specially, it is short of intraoral digital impression cases for immediate provisional restorations of the maxillary anterior implants. The gingival contour impression of maxillary anterior area is very important for esthetic restorations. Accordingly, in this case report, the using a digital impression coping (scanbody) and digital impression by CEREC Omnicam (Sirona, Bensheim, Germany) or Trios (3shape, Copenhagen, Denmark) were introduced for immediate provisional restorations in 3 cases needed a single implant restoration in maxillary anterior area. The clinical results were satisfactory on the convenience and accuracy of digital impression technique and the good esthetics of final restorations.

Rehabilitation of maxillary partial edentulous patients using implant assisted removable partial denture (상악 소수치 잔존 환자에서 임플란트를 이용한 가철성 부분틀니 수복 증례)

  • Lee, Bo-Ra;Kim, Jee-Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.2
    • /
    • pp.128-135
    • /
    • 2014
  • Treatment options for partially edentulous patients are fixed partial denture, removable partial denture and implant supported fixed partial denture. In case of a patient with a few remaining teeth, removable partial denture and implant supported fixed prosthesis are available. For implant fixed prothesis, enough implant fixtures are required and the patient's general condition, local factors and economic status must be considered. When the condition of the abutments and the residual ridge is favorable and the prosthesis is well designed, removable partial denture can be an option. In removable partial denture, the bilateral support is important. If the teeth remain unilateral, harmful stress is put on the abutments by the fulcrum line. In this situation, strategic implantation and implant-retained or assisted removable partial denture is beneficial to the retention and support of the denture. And this can be cost-effective, functional and esthetic choice of treatment. This article describes the prosthodontic rehabilitation of Maxillary Kennedy class I partially edentulous patients. In these two cases, the patients had a small number of teeth and they were restored by the combination of a removable partial denture and dental implants.

Fit analysis of CAD-CAM custom abutment using micro-CT (Micro-CT를 이용한 맞춤형 CAD-CAM 지대주의 적합성 분석)

  • Min, Gwang-Seok;Chung, Chae-Heon;Kim, Hee-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.370-378
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate screw joint stability and sagittal fit between internal connection implant fixtures of two different manufacturers and customized abutments. Materials and methods: Internal connection implant systems from two different manufacturers (Biomet 3i system, Astra Tech system) were selected for this study (n=24 for each implant system, total n=48). For 3i implant system, half of the implants were connected with Ti ready-made abutments and the other half implants were connected with Ti CAD-CAM custom ones of domestic-make (Myplant, Raphabio Co., Seoul, Korea) and were classified into Group 1 and Group 2 respectively. Astra implants were divided into Group 3 and Group 4 in the same way. Micro-CT sagittal imaging was performed for fit analysis of interfaces and preloading reverse torque values (RTV) were measured. Results: In the contact length of fixture-abutment interface, there were no significant differences not only between Group 1 and Group 2 but also between Group 3 and Group 4 (Mann-Whitney test, P>.05). However, Group 2 and Group 4 showed higher contact length significantly than Group 1 and Group 3 in abutment-screw interface as well as fixture-screw one (Mann-Whitney test, P<.05). In addition, RTV was lower in CAD-CAM custom abutments compared to ready-made ones (Student t-test, P<.05). Conclusion: It is considered that domestically manufactured CAD-CAM custom abutments have similar fit at the fixture abutment interface and it could be used clinically. However, RTV of CAD-CAM custom abutments should be improved for the increase of clinical application.

Effect of morphology and diameter of implant fixture-abutment connection on mechanical failure of implants (임플랜트 고정체-지대주 연결부의 형태와 직경이 임플랜트의 기계적 실패에 미치는 영향)

  • Yun, Bo-Hyeok;Shin, Hyon-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Jeong, Chang-Mo;Kang, Eun-Sook
    • The Journal of the Korean dental association
    • /
    • v.53 no.9
    • /
    • pp.644-655
    • /
    • 2015
  • Purpose: This study was conducted to evaluate the effect of the fixture abutment connection type and diameter on the screw joint stability in external butt joint for 2nd surgery and internal cone connected type implant system for 1st and 2nd surgery using ultimate fracture strength. Materials and Methods: USII system, SSII system and GSII system of Osstem Implant were used. Each system used the fixture with two different diameters and cement-retained abutments, and tungsten carbide / carbon coated abutment screws were used. Disc shaped stainless steel metal tube was attached using resin-based temporary cement. The experimental group was divided into seven subgroups, including the platform switching shaped specimen that uses a regular abutment in the fixture with a wide diameter in USII system. A static load was increased to the metal tube at 5mm deviated point from the implant central axis until it reached the compression bending strength at a rate of 1mm/min. Then the deformations and patterns of fracture in threaded connection were compared. Results and Conclusion: 1. In the comparison between the Regular diameter, compression bending strength of SSII system was higher than USII system and GSII system. There was no significant difference between USII system and GSII system. 2. In the comparison between wide diameter, compression bending strength was increased in the order of GSII system, USII system, and SSII system. 3. In comparison between the implant diameter, compression bending strength of the wide diameter was greater than the regular diameter in any system(P<0.05). 4. There was no significant difference between the platform switching (III group) and the regular diameter (I group) in USII system. 5. In USII system, fracture of abutment screw and deformation of both fixture and abutment were observed in I, II and III subgroups. 6. Failure pattern of SSII system, which was the fracture of abutment screw and deformation of the abutment and fixture, was observed in both IV and V subgroups. Fracture of some fixtures was observed in subgroup V. 7. Failure pattern of GSII system, which was the fracture of the abutment screw and deformation of the fixture and the abutment, was observed in both VI and VII subgroups. Apart from other subgroups, subgroup VII demonstrated no bending neither the fracture at the top of the fixture. The compressive deformation of internal slope in the fixture was the only thing observed in subgroup VII.

Retrospective Study of GS II Implant(Osstem) with an Internal Connection with Microthreads (Micro thread를 포함한 GSII RBM임플란트(Osstem)의 후향적 임상연구)

  • Chee, Young-Deok;Lee, Jae-Hwan;Oh, Sang-Chun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.417-429
    • /
    • 2009
  • Since the introduction of the concept of osseointegration in dental implants, high long-term success rates have been achieved and accepted as viable option for the treatment of fully and partially edentulous patients. Although the use of domestic implants have increased dramatically, there are few studies on domestic implants with clinical and objective long-term data. 96 endosseous implants placed in 31 patients at Wonkwang University Sanbon Dental Hospital were examined to determine the effect of various factors on implant survival rate and marginal bone loss, through clinical and radiographic results. The design of endosseous implant used to this study is straight with the microthread.(GS II RBM Fixture) 1. 3 fixtures were lost, resulting in 96.9% cumulative survival rate. 2. Survival rate in fifties was significantly lower (93.6%) and no significant difference in marginal bone loss was found according to gender. 3. Survival rates were 95.6% in the maxillary molar area and 97.3% in the mandible molar area. 4. No significant difference in survival rate was found according to presence of bone grafts, type of prostheses, implant position, and length and diameter of implant. 5. A factor influencing marginal bone loss was presence of type of prostheses, while facters such a length, diameter of fixture and bone grafts had no statistically significant effect on crestal bone loss. This study indicates the amount of marginal bone loss around implant has maintained a relative stable during follow-up periods.

Effect on bone formation of the autogenous tooth graft in the treatment of peri-implant vertical bone defects in the minipigs

  • Kim, Seok Kon;Kim, Sae Woong;Kim, Kyung Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.37
    • /
    • pp.2.1-2.9
    • /
    • 2015
  • Background: The aim of this study was to evaluate the effect of autogenous tooth bone as a graft material for regeneration of bone in vertical bony defects of the minipigs. Material and Methods: Six minipigs were used in this study. Four molars were extracted in the right mandibular dentition and sent to the Korea Tooth Bank for fabrication of autogenous tooth bone. Ten days later, each extraction site was implanted with MS Implant Narrow Ridge $3.0{\times}10mm$ fixture (Osstem, Seoul, Korea) after standardized 2mm-sized artificial vertical bony defect formation. Pineappleshaped Root-On type autogenous tooth bones were applied to the vertical defects around the neck area of the posterior three fixtures and the fore-most one was not applied with autogenous bone as a control group. Each minipig was sacrificed at 4, 8, 12 weeks after fixture installation and examined radiologically and histologically. Histological evaluation was done under light microscope with Villanueva osteochrome bone staining with semi-quantitative histomorphometric study. Percentage of new bone over total area (NBF) and bone to implant contact (BIC) ratio were evaluated using digital software for area calculation. Result: NBF were $48.15{\pm}18.02%$, $45.50{\pm}28.37%$, and $77.13{\pm}15.30%$ in 4, 8, and 12 weeks, respectively for experimental groups. The control group showed $37.00{\pm}11.53%$, $32.25{\pm}26.99%$, and $1.33{\pm}2.31%$ in 4,8,12 weeks, respectively. BIC ratio were $53.08{\pm}19.82%$, $45.00{\pm}28.37%$, and $75.13{\pm}16.55%$ in 4,8,12 weeks, respectively. Those for the control groups were $38.33{\pm}6.43%$, $33.50{\pm}29.51%$, and $1.33{\pm}2.31%$ in 4, 8, 12 weeks, respectively. Conclusion: Autogenous tooth bone showed higher score than control group in NBF and BIC in all the data encompassing 4,8,12 weeks specimens, but statistically significant only 12 weeks data in both NBF and BIC.

A BIOLOGIC STUDY ON TOOTHASH - PLASTER OF PARIS MIXTURE WITH ABSORBABLE COLLAGEN MEMBRANE IN THE TREATMENT OF PERI-IMPLANT DEFECTS (임플란트 주위염 치료시 치아회분말과 치과용 연석고의 혼합 매식의 골재생 효과)

  • Choi, Hee-Yeon;Kim, Hak-Kyun;Kim, Su-Gwan;Moon, Seong-Yong;Kim, Sang-Yeol;Park, Kwang-Bum;Kim, Young-Min;Lim, Seong-Chul;Kim, Eun-Seok;Lee, Jeong-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.2
    • /
    • pp.142-149
    • /
    • 2008
  • The purpose of this study was to evaluate histomorphometrically a toothash - plaster of Paris mixture associated with collagen membrane ($Bio-Gide^{(R)}$), regarding new bone formation in the peri-implantitis defects in dogs. Three mandibular molars were removed from 1-year-old mongrel dogs. After 2 months of healing, 2 titanium implants with sandblasted with large grit and acid etched (SLA) surface were installed in each side of the mandible. Experimental peri-implantitis was induced with ligatures after successful osseointegration. Ligatures were removed after identification of bone defect beneath the level of 5th thread of fixture on radiographic image. The mucoperiosteal flaps were elevated and the contaminated fixtures were treated with chlorhexidine and saline. The bone defects were assigned to one of the following treatments: no guided bone regeneration (GBR) procedure (group 1), GBR with Bio-$Oss^{(R)}$ and Bio-$Gide^{(R)}$ (group 2), or GBR with toothash - plaster of Paris mixture (TPM) and Bio-$Gide^{(R)}$ (group 3). The dogs were sacrificed after 8 or 16 months. The mean percentages of new bone formation within the limits of the 5 most coronal threads were $17.83{\pm}10.69$ (8 weeks) and $20.13{\pm}13.65$ (16 weeks) in group 1, $34.25{\pm}13.32$ (8 weeks) and $36.33{\pm}14.21$ (16 weeks) in group 2, and $46.33{\pm}18.39$ (8 weeks) and $48.00{\pm}17.78$ (16 weeks) in group 3, respectively. The present study confirmed statistically considerable new bone formation within the threads in group 3 compared with group 1 at 8 and 16 weeks (P<0.05). Although, data analysis did not reveal significant differences between group 2 and 3, the latter showed better results during the period of 8 or 16 weeks. Our findings support the effectiveness of TPM as a GBR material in the treatment of peri-implantitis bone defect.

Marginal Bone Resorption Analysis of Dental Implant Patients by Applying Pattern Recognition Algorithm (패턴인식 알고리즘을 적용한 임플란트 주변골 흡수 분석)

  • Jung, Min Gi;Kim, Soung Min;Kim, Myung Joo;Lee, Jong Ho;Myoung, Hoon;Kim, Myung Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.3
    • /
    • pp.167-173
    • /
    • 2013
  • Purpose: The aim of this study is to analyze the series of panoramic radiograph of implant patients using the system to measure peri-implant crestal bone loss according to the elapsed time from fixture installation time to more than three years. Methods: Choose 10 patients having 45 implant fixtures installed, which have series of panoramic radiograph in the period to be analyzed by the system. Then, calculated the crestal bone depth and statistics and selected the implant in concerned by clicking the implant of image shown on the monitor by the implemented pattern recognition system. Then, the system recognized the x, y coordination of the implant and peri-implant alveolar crest, and calculated the distance between the approximated line of implant fixture and alveolar crest. By applying pattern recognition to periodic panoramic radiographs, we attained the results and made a comparison with the results of preceded articles concerning peri-implant marginal bone loss. Analyzing peri-implant crestal bone loss in a regression analysis periodic filmed panoramic radiograph, logarithmic approximation had highest $R^2$ value, and the equation is as shown below. $y=0.245Logx{\pm}0.42$, $R^2=0.53$, unit: month (x), mm (y) Results: Panoramic radiograph is a more wide-scoped view compared with the periapical radiograph in the same resolution. Therefore, there was not enough information in the radiograph in local area. Anterior portion of many radiographs was out of the focal trough and blurred precluding the accurate recognition by the system, and many implants were overlapped with the adjacent structures, in which the alveolar crest was impossible to find. Conclusion: Considering the earlier objective and error, we expect better results from an analysis of periapical radiograph than panoramic radiograph. Implementing additional function, we expect high extensibility of pattern recognition system as a diagnostic tool to evaluate implant-bone integration, calculate length from fixture to inferior alveolar nerve, and from fixture to base of the maxillary sinus.

THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE BONE ANCHORED FIXED PROSTHESIS ACCORDING TO THE LOAD CONDITION (골유착 고정성 보철물 하에서 하중조건에 따른 삼차원 유한요소법적 분석)

  • Yang, Soon-Ik;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.4
    • /
    • pp.780-806
    • /
    • 1995
  • The purpose of this study was to describe the application of 3D finite element analysis to determine resultant stresses on the bone anchored fixed prosthesis, implants and supporting bone of the mandible according to fixture numbers and load conditions. 4 or 6 fixtures and the bone anchored fixed prosthesis were placed in 3D finite element mandibular arch model which represents an actual mandibular skull. A $45^{\circ}$ diagonal load of 10㎏ was labiolingually applied in the center of the prosthesis(P1). A $45^{\circ}$ diagonal load of 20㎏ was buccolingually applied at the location of the 10mm or 20mm cantilever posterior to the most distal implant(P2 or P3). The vertical distribution loads were applied to the superior surfaces of both the right and the left 20mm cantilevers(P4). In order that the boundary conditions of the structure were located to the mandibular ramus and angle, the distal bone plane was to totally fixed to prevent rigid body motion of the entire model. 3D finite element analysis was perfomed for stress distribution and deflection on implants and supporting bone using commercial software(ABAQUS program. for Sun-SPARC Workstation. The results were as follows : 1. In all conditions of load, the hightest tensile stresses were observed at the metal lates of prostheses. 2. The higher tensile stresses were observed at the diagonal loads rather than the vertical loads 3. 6-implants cases were more stable than 4-implants cases for decreasing bending and torque under diagonal load on the anterior of prosthesis. 4. From a biomechanical perspective, high stress developed at the metal plate of cantilever-to-the most distal implant junctions as a consequence of loads applied to the cantilever extension. 5. Under diagonal load on cantilever extension, the 6-implants cases had a tendency to reduce displacement and to increase the reaction force of supporting point due to increasing the bendign stiffness of the prosthesis than 4-implants cases. 6. Under diagonal load on cantilever extension, the case of 10mm long cantilever was more stable than that of 20mm long cnatilever in respect of stress distribution and displacement. 7. When the ends of 10mm or 20mm long cantilever were loaded, the higher tensile stress was observed at the second most distal implant rather than the first most distal implant. 8. The 6-implants cases were more favorable about prevention of screw loosening under repeated loadings because 6-implants cases had smaller deformation and 4-implants cases had larger deformation.

  • PDF

CHANGES OF ABUTMENT SCREW AFTER REPEATED CLOSING AND OPENING

  • Kim Hee-Jung;Chung Chae-Heon;Oh Sang-Ho;Choi Han-Cheol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.6
    • /
    • pp.628-640
    • /
    • 2004
  • Statement of problem. Wear as a result of repeated closing/opening cycles may decrease the friction coefficient of screw head, threads, and other mating components and, consequently, resistance to opening gradually decreases. It may cause screw loosening, which is one of the most common failures in implant prosthesis. Purpose. The purpose of this study is to evaluate the changes on the head and thread surface of the abutment screws after repeated closing and opening through the examination of tested screws in SEM(scanning electron microscope). Materials and methods. Five species of abutments were selected (3i-three, Avana-two) respectively by two pieces. The implant fixtures were perpendicularly mounted in liquid unsaturated polyesther(Epovia, Cray Valley Inc.) with dental surveyor. Each abutment was secured to the implant fixture by each abutment screw with recommended torque value using a digital torque controller. The abutment screws were repeatedly tightened and removed 20 times with a digital controller. FESEM (field emission scanning electron microscope, Netherland, Phillips co., model:XL 30 SFEG) was used to observe changes of each part caused by repeatedly closing/opening expeiment. First, the Photomicrographs of pre-test screws provided by each manufacturer were taken. The changes of each screw were investigated after every fifth closing and opening experiment with FESEM. Scaning electron microscope photomicrographs of each screw were taken four times. Results. As the number of closing and opening was increased, the wear or distortion of hexed or squared slot that contacted with the driver tip was more severely progressed. Wear or distortion of hexed slot was more severe than that of squared slot and it was more remarkable in the titanium screw than in the gold screw. All the tested screws showed that the width in the crest of their screw thread decreased gradually as the test was proceeded. Conclusions. Conclusively, we recommend the clinical use of gold screw, a periodic exchanges of abutment screws and avoiding repeated closing/opening unnecessarily. We also suggest a more careful manipulation of the abutment screw and screw-driver and using of abutment screw with an acute-angled slot design rather than an obtuse-angled one. Finally, it is suggested that the new slot design and the surface treatment for enduring wear or distortion should be devised.