• Title/Summary/Keyword: fixtures

Search Result 384, Processing Time 0.028 seconds

Analysis of Propagation Characteristics according to the Change of Transmitter-Receiver Location in Indoor Environment (실내 환경에서 송수신기 위치 변화에 따른 전파 전달 특성 분석)

  • Lee, Seong-Hun;Cho, Byung-Lok;Lee, Hwa-Choon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.2
    • /
    • pp.211-218
    • /
    • 2020
  • The radio wave propagation characteristics of the transmitter and receiver position change in the indoor environment were predicted through simulation, then the results obtained through the transmission loss measurement were compared and analyzed with the simulation results. The conference room was chosen as the environment for measuring transmission loss, and the radio transmission characteristics of the two environments were compared by selecting the exhibition hall without interior decorations and fixtures. In each indoor environment, the position of the transmitter chose two cases. One located in the center of the front wall and the other in the center of the side wall, and the position of the receiver moved along the centerline of the conference room and the side wall, measuring the receiving power. For each change in transmitter-receiver position, received power of 3GHz and 6GHz band were measured and compared with the simulation forecast results. The changes in received power at each receiving point were analyzed according to the location of the transmitter and the frequency band variation.

A STUDY ON THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE STRESSES ACCORDING TO THE CURVATURE OF ARCH AND PLACEMENT OF IMPLANTS (악궁의 만곡도 및 임플랜트 위치에 따른 삼차원적 유한요소 응력분석)

  • Lee, Don-Oh;Chung, Chae-Heon;Cho, Kyu-Zong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.1
    • /
    • pp.98-129
    • /
    • 1995
  • The purpose of this study was to evaluate how mandibular implant-supported fixed complete prosthesis, implant and mandible responded mechanically, according to curvature of arch, number and location of fixture, and amounts of load. The shape of mandibular arch was tapered or square form and, 4 or 6 fixtures were implanted in each arch model. A vertical load of 10kg was applied at the center of prosthesis and a vertical load of 20kg was applied at the location of the 10mm or 20mm cantilever posterior to the most distal implant. Three-dimensional finite element analysis was performed for stress distribution and deflection using commercial software(ABAQUS program) for Sun-SPARC Workstation. The results were as follows : 1. The case square arch form was more stable to compare with that of tapered arch form in respect of stress distribution and displacement under vertical load on the center of prosthesis. 2. 6-implants cases were more stable than 4-implants cases for decreasing bending torque under vertical load on the center of prosthesis. 3. Under vertical load on cantilever extension, the case of 10mm long cantilever was more stable than that of 20mm long cantilever in respect of stress distribution and displacement. 4. Under vertical load on cantilever extension, 6-implants cases had a tendency to reduce displacement and to increase the reaction force of supporting point due to increasing of the bending stiffness of the prosthesis than 4-implant case. 5. When the ends of 10mm or 20mm long cantilever were loaded, the most distal implant was under compressive stress but the second most distal implant was under the highest tensile stress and the remaining implants were under varying tensile stress. 6. Because 6-implants cases had smaller displacement than 4-implants cases, 6-implants cases were more favorable in respect of prevention of screw loosening under repeated loadings.

  • PDF

Sinking and fit of abutment of locking taper implant system

  • Moon, Seung-Jin;Kim, Hee-Jung;Son, Mee-Kyoung;Chung, Chae-Heon
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.2
    • /
    • pp.97-101
    • /
    • 2009
  • STATEMENT OF PROBLEM. Unlike screw-retention type, fixture-abutment retention in Locking taper connection depends on frictional force so it has possibility of abutment to sink. PURPOSE. In this study, Bicon$^{(R)}$ Implant System, one of the conical internal connection implant system, was used with applying loading force to the abutments connected to the fixture. Then the amount of sinking was measured. MATERIAL AND METHODS. 10 Bicon$^{(R)}$ implant fixtures were used. First, the abutment was connected to the fixture with finger force. Then it was tapped with a mallet for 3 times and loads of 20 kg corresponding to masticatory force using loading application instrument were applied successively. The abutment state, slightly connected to the fixture without pressure was considered as a reference length, and every new abutment length was measured after each load's step was added. The amount of abutment sinking (mm) was gained by subtracting the length of abutment-fixture under each loading condition from reference length. RESULTS. It was evident, that the amount of abutment sinking in Bicon$^{(R)}$ Implant System increased as loads were added. When loads of 20 kg were applied more than 5 - 7 times, sinking stopped at $0.45{\pm}0.09\;mm$. CONCLUSION. Even though locking taper connection type implant shows good adaption to occlusal force, it has potential for abutment sinking as loads are given. When locking taper connection type implant is used, satisfactory loads are recommended for precise abutment location.

ACCURACY OF THE IMPRESSION TECHNIQUE USING THERMOFORMING POLYMETHYL METHACRYLATE TRAY

  • Miyashita, Yuko;Suzuki, Hiroki;Kishi, Masataka;Ko, Sok-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.389-400
    • /
    • 2007
  • Statement of problem. Use of the conventional dental impression procedure is problematic in patients who have difficulty opening their mouth, difficulty breathing through their nose or tendency to gag. Purpose. It is necessary to make individual trays more comfortable for patients during impression taking procedure. It was reported at the KAP Annual Meeting 2001 Seoul that an improved impression technique was suitable for this purpose. In this study, the accuracy of the improved dental impression method for implant was compared with the conventional dental impression method. Material and methods. An oral simulator was made from clear acrylic resin block which had similar form of edentulous ridge. For setting up the standard, five fixtures were installed on it. Study casts were made using two kinds of impression techniques. One was the conventional method that was taken using silicone impression material and an individual resin tray under connection of inter-fixture relation. The other was the improved method in which was the connection of the impression coping and the thermoformed polymethyl methacrylate tray. In addition, two different study casts were made from the improved impression body. The coordinates of the fixture on the study model were measured by three-dimensional coordinate measuring equipment. Then the distances between each fixture were calculated and compared with that of oral simulator. Accuracy of the each impression method was also assessed. Results. The differences of inter-fixture dimension between study casts and simulator in the improved impression technique showed $0.014{\pm}0.016mm$ and $0.017{\pm}0.022mm$, respectively and that of the conventional method was $0.017{\pm}0.014mm$. There was no significant difference between the improved impression technique and conventional method. Conclusion. The improved impression technique is useful for multiple support implants.

COMPARISON BETWEEN $TIUNITE^{TM}$ AND ANOTHER OXIDIZED IMPLANT USING THE RABBIT TIBIA MODEL

  • Yeo, In-Sung;Lee, Jai-Bong;Han, Jung-Suk;Kim, Sung-Hun;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.339-344
    • /
    • 2007
  • Statement of problem. Various anodic oxidation techniques can be applied to dental implant surfaces. But the condition for optimal anodized surfaces has not been described yet. Purpose. The purpose of this investigation was to compare an implant that was oxidized by another method with $TiUnite^{TM}$ through resonance frequency analysis and histomorphometry. Material and methods. Turned (control), $TiUnite^{TM}$ and another oxidized fixtures, which used $Ca^{2+}$ solution for anodic oxidation, were placed in the tibiae of 5 New Zealand White rabbits. The bone responses were evaluated and compared by consecutive resonance frequency analysis once a week for 6 weeks and histomorphometry after a healing period of 6 weeks. Results. At the first week, both oxidized implants showed significantly higher implant stability quotient (ISQ) values than the control. No significant differences in resonance frequency analysis were found between the two oxidized groups for 6 weeks. The means and standard deviations of bone-to-implant contact (BIC) ratios were $71.0{\pm}4.2$ for $TiUnite^{TM}$, $67.5{\pm}10.3$ for the $Ca^{2+}$-based oxidation fixture, $22.8{\pm}6.5$ for the control. Both oxidized implants were significantly superior in osseointegration to the turned one. There was, however, no statistically significant difference between the two oxidized implants. Conclusion. $TiUnite^{TM}$ and the $Ca^{2+}$-based oxidation fixture showed superior early bone response than the control with respect to resonance frequency analysis and histomorphometry. No significant differences between the oxidized groups, however, were found in this investigation using the rabbit tibia model.

Streetscape Design of Arroyo Parkway, Pasadena, California (아로요 파크웨이 조경설계)

  • Jeong Wook-Ju
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.32 no.4
    • /
    • pp.105-117
    • /
    • 2004
  • The Pasadena Freeway follows the Arroyo Seco through foothills and scenic passes to link Downtown Los Angeles with Pasadena. The approximately 10 mile road was the first freeway built in the West during the 1930's and is today designated as a Historic Parkway. As it approaches Pasadena, it terminates at a traffic light intersection at Glenarm Street, and then becomes a commercial road the Arroyo Parkway. This one and a quarter mile long, north south road moves significant volumes of traffic both into and out of Pasadena. The Arroyo Parkway is thus a major 'gateway' and an important axis of orientation and movement, terminating in the City's core civic, commercial and retail district. Planting, lighting, signage, paving, furnishing and fixtures ought to all be properly designed and coordinated to create a distinctive 'gateway' experience arriving to Pasadena and driving along the Arroyo Parkway. Alternate design studies, developed in discussion with City officials and others involved in the redevelopment of the area, would need to be done to properly decide on the best direction. Issues of heritage and traditional streetscape will likely have to be reconciled with both the reality of the vehicular character of the road and more contemporary themes. Obviously with such large parcels of property available in the Arroyo Fair Oaks corridor, there is a huge potential for redevelopment and building. This potential would only be strengthened by the Light Rail Line and its stations, the improvements to the Arroyo Parkway, and the redevelopment of the Arts Center College of Design. Guides and controls to the development process, including programming and physical design studies, would need to be developed in order to ensure that the maximum potential for the corridor be realized. This concept proposal suggests that the whole strip might be developed as a Arts and Technology corridor, with special emphases on education, public culture, media and lifestyle. The full programming possibilities need to be further developed. Additionally, appropriate urban design guidelines to ensure high quality development also need to be incorporated into an overall development plan.

Performance of Detection Probability based on Energy Sensing Schemes for VLC Systems (가시광 통신 시스템을 위한 에너지 센싱 기법을 이용한 신호 검출 확률의 성능)

  • Park, In-Hwan;Kim, Yoon-Hyun;Kim, Jin-Young
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.10B
    • /
    • pp.1233-1239
    • /
    • 2011
  • The visible light convergence communication technology is suitable for indoor wireless communication and digital lighting fixtures, it could be used as lighting devices as well as a communication device. However, because that VLC is the technology of came to world a few years ago, there are many problems which had to solve. The signal sensing of VLC transmitter is one of the most challenging issue in VLC systems. Therefore in this paper, we analysis the performance of various sensing scheme for efficient detection of VLC systems. The signal of user is OFDM signal and the wirelss channel between a user and VLC system is modeled as indoor VLC channel. From the simulation results, it is confirmed that the proposed scheme is very effective to signal sensing for VLC systems.

A Case Study of the Design of Robot Welding Station in an Excavator Factory Using 3D Simulation (굴삭기공장의 로봇용접 작업장 설계에 대한 3D 시뮬레이선 사례 연구)

  • Moon, Dug-Hee;Cho, Hyun-Il;Baek, Seung-Geun
    • Journal of the Korea Society for Simulation
    • /
    • v.15 no.1
    • /
    • pp.51-58
    • /
    • 2006
  • Virtual Manufacturing is a powerful methodology for developing a new product, new equipment and new production system. It enables the checking errors in design before production. This paper is a case study of virtual manufacturing in an excavator factory. The final welding operations of the boom and the rotating table of upper body are selected for application. 3D models of parts and fixtures are developed with $CATIA^{(R)}$ and 3D simulation models are developed with $IGRIP^{(R)}$. These models are used for verifying the design of fixture and for the motion design of robot. As a result, the manual welding systems are replaced by automatic systems and many design errors are corrected in the design phase, which reduces the developing cost and time.

  • PDF

Effect of Measuring Method on the Evaluation of Piezoelectric and Dielectric Properties of PMN-PT Single Crystal (PMN-PT 단결정의 압전 및 유전 특성 평가에 미치는 측정 방법의 영향)

  • Kim, Yong Soo;Park, Jae Hwan;Lee, Jeongho;Lee, Sang Goo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.4
    • /
    • pp.69-74
    • /
    • 2019
  • The influence of measuring fixtures on the measurement of dielectric and piezoelectric properties of PMN-PT single crystal specimens was investigated. As the pressure of the jig pin which applied the AC electrical signal to the sample decreased, the lower resonance resistance was measured and the higher mechanical quality factor was calculated. The mechanical quality factor was 418 when the spring tension of the jig pin was 20grf, and the value of the quality factor was reduced by half when the spring tension was 200grf. The 4-probe fixture method is unsuitable for measuring piezoelectric properties, but it was suitable for the measurement of dielectric loss. In order to accurately evaluate the piezoelectric properties of PMN-PT, it is necessary to lower the spring tension of the jig pin as much as possible.

The effect of osteotome technique on primary implant stability according to implant fixture diameter (임플란트 일차 안정성에 있어서 고정체 지름에 따른 osteotome 술식의 효과)

  • Kim, Su-Hyun;Lee, Jae-Kwan;Park, Chan-Jin
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.3
    • /
    • pp.789-798
    • /
    • 2005
  • Primary stability is a fundamental criteria of implant success. There has been various trials to increase initial stability and bone to implant contact. The objective of osteotome technique is to preserve all the existing bone by minimizing or even eliminating the drilling sequence of the surgical protocol. The bone layer adjacent to the osteotomy site is progressively compacted with various bone condensers(osteotomes) this will result in a denser bone to implant contact. This improved bone density helps to optimize primary implant stability in low density bone. The use of wide implant is one of methods to increse primary stability. They can be used in special situations in which they can increase the surface area available for implant anchorage and improve their primary stability The aim of this study was to evaluate the influence of the osteotome technique and implant width on primary stability. Osteotome technique was compared with conventional drilling method by resonance frequency measurments according to the implant fixtures diameter. The results were as follows: 1. The average of ISQ value was sightly higher in osteotome technique, but there was not statistically significant in regular and narrow implant(p <0.05). 2. Either osteotome technique or conventional technique. ISQ value was significantly higer as increasing of implant diameter(p <0.05). 3. ISQ value of drilling technique was higer than those of osteotome technique in wide implant. It was assumed to be caused by difference in final preparation diameter.