• Title/Summary/Keyword: fixtures

Search Result 384, Processing Time 0.027 seconds

A Study on the Visual Phenomenon of Natural Light in Interior Space (실내공간에 있어 자연광에 의한 시지각적 현상에 관한 연구)

  • 김주연
    • Korean Institute of Interior Design Journal
    • /
    • no.13
    • /
    • pp.130-138
    • /
    • 1997
  • This study is to present the visual phenomenon of natural light in the interior space. The continuously changing natural light define the visual phenomenon of the architectural space. First, the objective of this study was finding the importance of the visual phenomena which were generated from correlating natural right with the interior space. And the second was to categorize the factors of the visual phenomenon which can be useful factors for modern interior design practice. As a result of this study, two visual phenomena were classified. First; territorial phenomenon: dividing, partitioning, and sectioning by natural light, Second; phenomena by the inflow methods of natural light; a) by direct inflow; transparency, expansion, and floating, b) by filtering fixtures; the architectural structure, color, and the transluscent material, c) by dramatic spacial present of natural light, d) by the sense of direction of naturel light; continuity, and transformatiov. Found and classified each factor is not presented by itself, rather compounded forms. Because of the limited analysis of modern buildings, these found visual factors can not represent all phenomena. But if we practice these finding factors to design present interior space, it is sure of being very valuable factors to re-introduce the overlooked natural light into interior space.

  • PDF

A study on applicability of mirror reflector system in tunnel using simulation (시뮬레이션 분석을 통한 반사거울 시스템의 터널 적용성 연구)

  • Lee, Beom-Seok;Lee, Kun-Il;Jeong, In-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.5
    • /
    • pp.371-383
    • /
    • 2011
  • It is important to secure illumination for the driver's safety because the tunnel is a space for changing brightness quickly, and lighting fixtures of the tunnel have consumed a lot of electric lighting energy for operating in both the daytime and at night. This study aims to evaluate daylighting performance of Mirror Reflector System for luminous environment improvement of tunnel space by using RADIANCE simulation program. The results of simulation show that illuminance of bar type is higher than illuminance of pole type at 20 m from the tunnel entrance.

A Study on the Actual Condition of Illumination Environment in Public Libraries in Daegu

  • Seo, Ji-Eun;Kim, Hyun-Ji;Kim, Sung-Hwa;An, Ok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.3
    • /
    • pp.1-9
    • /
    • 2009
  • This study investigated the actual condition focusing on the lighting environment which is a major element in aspect of indoor environment of a public library and assessed user satisfaction. Research results are as follows: Firstly, numbers of lighting fixtures per dimension of a reading room in a public library were inconsistent due to the lack of definite regulations, which was found to have negative effect on night time illuminance. Secondly, it was assessed that illuminance between the day time influenced by natural lighting and in the nighttime without natural lighting has more than 10-fold difference. Therefore, such a condition is judged to be inappropriate for lighting environment of a reading room where users spend a long time studying and thus, it is considered that an appropriate measures should be taken. Thirdly, as the survey result on users' satisfaction with lighting environment was revealed to be lesser than 3 points, lighting plan in consideration of its users should be progressed.

An Analysis of the Comparison for a Trend on the Interior Lighting Design of High-rise Office Buildings Between Overseas and Domestic (국내.외 초고층 오피스건축물의 조명설계 경향 비교 분식)

  • Jeong, Keun-Young;Hong, Seong-Kwon;Chol, An-Seop;Lee, Jeong-Ho;Mistrick, Richard
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.42-50
    • /
    • 2008
  • There are many plans of the high-rise buildings these days in domestic and will be constructed from now on. It is required to develop energy saving techniques immediately because the high-rise buildings consume a lot of energy. The most effective energy savings method is the application of the efficient lighting designs and fixtures. The purpose of this study is to analyze a trend of lighting design, fixture and control system between overseas and domestic. It can be used the guide line for the high-rise buildings in domestic application.

A Study on Interference Phenomenon of a Machine Tool when 5 Axises Working with Virtual Machine Tool (가상공작기계를 이용한 5축 가공 시 공작기계의 간섭현상에 관한 연구)

  • Kim, Hae-Ji;Jang, Jeong-Hwan;Kim, Nam-Kyung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.4 no.2
    • /
    • pp.16-23
    • /
    • 2005
  • This study is intended to find out the reason of interference phenomenon of a machine tool when it operates for 5-axises working. The researcher made a Virtual Machine which has same figures of the 5 axises machine tool and Virtual Manufacturing System which has both Software factors - controller and NC code data to manipulate the movement characteristics of the machine - and Hardware factors - fixtures, workpiece, tools, holders and so on. With these virtual tools, this study is designed to find out the relation between the movement and the interference or collision, and also intended to verify the simulation and work-processing. In this study, the researcher found out, in case of the vertical 5 axises type, that it has more chances to have interference between the fixture, the workpiece and the main spindle including the tool holder due to the tilting kinetics of the main spindle. In case of the horizontal 5 axises type, on the other hand, the researcher found out that it has more possibility to have the interference between the main spindle and the rotary shaft.

  • PDF

RADIOGRAGHIC STUDY OF MARGINAL BONE LOSS AROUND OSSEOINTEGRATED IMPLANTS AFTER FUNCTIONAL LOADING (보철물 장착후 골 유착성 임플란트 변연골 소실에 관한 방사선학적 연구)

  • Park, Ki-Hyun;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.6
    • /
    • pp.806-815
    • /
    • 1998
  • Regular radiographic examination has been considered as an essential diagnostic method for the osseointegrated dental implantation. This study investigated the marginal bone loss through the measurement on the periapical radiograph around 46 endosseous dental implants. Marginal bone loss have been observed for 5 years after delivery of prostheses. The results were as follows : 1. According to the experimental periods, average marginal bone loss in total implant was 1.821mm in the first year, 1.833mm in the second, 1.892mm at third, 1.910mm at forth and 1.957mm at fifth after delivery of prostheses(P<0.05). 2. The average bone loss was 1.832mm in the maxillae and 1.819mm in the mandible in three years but there was no significant difference between the upper and lower jaw(P>0.05). 3. The average bone loss was 1.824mm in males and 1.818mm in females in five years but there was no significant difference according to the sex(P>0.05). These results indicate that the most of the alveolar bone loss occur within the first year after delivery of dental prostheses resulting in the exposure of polished neck positions, and the bone level stabilizes at first thread portion of the implant fixtures.

  • PDF

Full Scale Airframe Static Test of 4 Seater Canard Airplane (4인승 선미익 경항공기 전기체 정적 구조시험)

  • Shin, Jeong-Woo;Kim, Sung-Chan;Kim, Sung-Jun;Chae, Dong-Chul;Lee, Sang-Wook;Kim, Tae-Uk;Shim, Jae-Yeul
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.15-23
    • /
    • 2006
  • In this paper, full-scale airframe static test of 4-seater canard airplane(the Firefly) was explained. From the results of the structural analysis, 5 design limit loads test conditions and 11 design ultimate loads test conditions were selected. Test loads analysis was performed and test fixtures and load control system(LCS) were prepared to realize the test loads. To protect the test article during the test, the overload protection system was prepared. Strain and deflection values were acquired through the data acquisition system(DAS) to verify the structural analysis results.

A Study on Developing a Teardrop LED Lighting Fixture and Economic Analysis at Industrial Clean Rooms (산업용 클린룸에서의 Teardrop LED 등기구 개발 및 경제성 분석에 관한 연구)

  • Lhee, Sang Choon;Choi, Yeo Jin;Choi, Young Joon
    • KIEAE Journal
    • /
    • v.13 no.4
    • /
    • pp.63-68
    • /
    • 2013
  • On the electricity consumption in Korea, the lighting sector takes about 17% of annual total electricity consumptions. In the midst of higher interests on energy conservation measures, design and choice of energy-saving lighting fixtures have been more important. With growth of technology-intensive industries like advanced material, semiconductor, and biotechnology from the 1980s, needs for clean room and thus illumination at clean rooms have been increased. In this paper, development, specification, and features of a Teardrop LED(hereinafter TD LED) lighting fixture as replacement of Teardrop florescent lighting one that has been popularly installed at clean rooms were presented. Also we performed the economic analysis of return on investment(ROI) about energy savings by the installation of the TD LED lighting fixture at a new-built clean room. The economic analysis showed that the new-developed TD LED lighting fixture would be able to withdraw the initial installation cost within 4 years. Lastly, improvement directions and development plans of the next TD LED lighting fixture for wider applications at clean rooms were described.

IN VITRO COMPARATIVE STUDY BETWEEN ISQ AND $PERIOTEST^{(R)}$ VALUES ON THE IMPLANT STABILITY MEASUREMENTS ACCORDING TO THE INCREASED EFFECTIVE IMPLANT LENGTH

  • Park Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.6
    • /
    • pp.625-632
    • /
    • 2001
  • Statement of Problem. Objective and quantitative measurement of implant stability is very important from implant installation to long-lasting maintenance period thereafter. Purpose of study. This study was to evaluate and compare two ISQ and PTVs on the implant stability measurements according to the increased effective implant length. Materials and methods. Twenty self-tapping fixtures were installed in the bovine scapula and in 10 of those for group I, ISQ and PTVs were obtained in the vertical/horizontal directions according to the increased effective implant length using $Osstell^{TM}$ and $Periotest^{(R)}$. After stability measurement, removal torques were measured between the after installation and after thread exposure group. Results. ISQ and PTVs showed decreased and increased values according to the increased abutment length. Apart from PTVs, ISQ values were shown higher in horizontal direction to the long axis of bone in both the after installation and the after thread exposure groups. Removal torque values were shown higher in after installation group. Conclusion. From the results of this study, implant stability measurement using resonance frequency analysis was more sensitive and discriminative than PTVs measurement.

  • PDF

Long-term results of new deproteinized bovine bone material in a maxillary sinus graft procedure

  • Shin, Seung-Yun;Hwang, You-Jeong;Kim, Jung-Hoon;Seol, Yang-Jo
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.5
    • /
    • pp.259-264
    • /
    • 2014
  • Purpose: The aim of this case report is to present the longitudinal results of sinus grafting using a new demineralized bovine bone material (DBBM) in human cases. Methods: A patient with a resorbed maxilla was treated by maxillary sinus grafting using a new deproteinized bovine bone material. After a healing period of 6.5 months, three implants were placed and restored. The patient was periodically recalled and followed up for 5 years after restoration. Results: Twelve partially edentulous patients (average age, 55.7 years) were followed up. All patients had insufficient residual height in their maxillary posterior area and underwent maxillary sinus graft surgery to increase the height of their maxilla. In all, 27 fixtures were placed in the augmented bone area. On average, 8.6 months later, implants were loaded using provisional or final restorations. The observation period ranged from 27 to 75 months (average, 43.3 months), and the patients did not show any severe resorption of the graft material or any infection during this time. Conclusions: Our results show that the new DBBM is useful for a maxillary sinus graft procedure. Good healing responses as well as reliable results were obtained for an average follow-up period of 43.3 months.