• 제목/요약/키워드: fixed-width

검색결과 457건 처리시간 0.024초

Voltage dependent pulse shape analysis of Geiger-Müller counter

  • Almutairi, B.;Akyurek, T.;Usman, S.
    • Nuclear Engineering and Technology
    • /
    • 제51권4호
    • /
    • pp.1081-1090
    • /
    • 2019
  • Detailed pulse shape analysis of a Geiger-$M{\ddot{u}}ller$ counter is performed to understand the pulse shape dependence on operating voltage. New data is presented to demonstrate that not all pulses generated in a GM counter are identical. In fact, there is a strong correlation between the operating voltage and the pulse shape. Similar to detector deadtime, pulse shapes fall in three distinct regions. For low voltage region, where deadtime was reported to reduce with increasing voltage, pulse generated in this region was observed to have a fixed pulse width with a variable tail. The pulse width and fall time of the tail was observed to be a function of applied voltage; exponentially reducing with increasing voltage with an exponent of negative 6E-04 and 2E-03 respectively. The second region showed a pulse without any significant tail. During this time the detector deadtime was earlier reported to be at its minimum. The highest voltage region demonstrated a different deadtime mechanism where the second pulse was reduced in width. During this time the deadtime seemed to be increasing with increasing voltage. This data allows us to gain some unique insight into the phenomenon of GM detector deadtime not reported thus far.

일반화 서포트벡터 분위수회귀에 대한 연구 (Generalized Support Vector Quantile Regression)

  • 이동주;최수진
    • 산업경영시스템학회지
    • /
    • 제43권4호
    • /
    • pp.107-115
    • /
    • 2020
  • Support vector regression (SVR) is devised to solve the regression problem by utilizing the excellent predictive power of Support Vector Machine. In particular, the ⲉ-insensitive loss function, which is a loss function often used in SVR, is a function thatdoes not generate penalties if the difference between the actual value and the estimated regression curve is within ⲉ. In most studies, the ⲉ-insensitive loss function is used symmetrically, and it is of interest to determine the value of ⲉ. In SVQR (Support Vector Quantile Regression), the asymmetry of the width of ⲉ and the slope of the penalty was controlled using the parameter p. However, the slope of the penalty is fixed according to the p value that determines the asymmetry of ⲉ. In this study, a new ε-insensitive loss function with p1 and p2 parameters was proposed. A new asymmetric SVR called GSVQR (Generalized Support Vector Quantile Regression) based on the new ε-insensitive loss function can control the asymmetry of the width of ⲉ and the slope of the penalty using the parameters p1 and p2, respectively. Moreover, the figures show that the asymmetry of the width of ⲉ and the slope of the penalty is controlled. Finally, through an experiment on a function, the accuracy of the existing symmetric Soft Margin, asymmetric SVQR, and asymmetric GSVQR was examined, and the characteristics of each were shown through figures.

FEM해석 기반 스퍼기어 펌프의 실험적 검증에 대한 연구 (Experimental Verification of Spur Gear Pump based on FEM Analysis)

  • 이찬우;김상유;이서한;김재열;임진혁
    • 한국기계가공학회지
    • /
    • 제21권6호
    • /
    • pp.1-7
    • /
    • 2022
  • This work investigated the performance improvement of a medium-pressure fixed-displacement-type SPUR gear pump, which is mainly used in the machine tool industry. The 3D CFX analysis and IS technique were applied using ANSYS (commercial FEM code) and compared with experimental results to ensure the reliability of the analysis. In addition, the performance improvement of the pump was obtained using the theoretical volumetric displacement equation, and the gear tooth width was changed. The pressure flow performance curves were compared, and the results were analyzed according to the width of the gear teeth. This is a factor that can cause irregular flow, vibration, and noise inside the gear pump owing to friction between the housing and gear pump.

Orthodontic treatment in a patient with Moebius syndrome: A case report

  • Lee, Sanghee;Moon, Cheol-Hyun
    • 대한치과교정학회지
    • /
    • 제52권6호
    • /
    • pp.451-460
    • /
    • 2022
  • Moebius syndrome (MBS) is a congenital neurologic disorder that causes cranio-facial abnormalities. It involves paralysis of the VI and VII cranial nerves and causes bilateral or unilateral facial paralysis, eye movement disorder, and deformation of the upper and lower limbs. The orofacial dysfunctions include microstomia, micrognathia, hypotonic mimetic and lip muscles, dental enamel hypoplasia, tongue deformity, open bite or deep overbite, maxillary hypoplasia, high arched palate, mandibular hyperplasia or features indicating mandibular hypoplasia. This case report presents a 7-year-old male patient who was diagnosed with MBS at the age 2 years. The patient displayed typical clinical symptoms and was diagnosed with Class II malocclusion with a large overjet/overbite, tongue deformity and motion limitation, and lip closure incompetency. Treatment was initiated using a removable appliance for left scissor bite correction. After permanent tooth eruption, fixed appliance treatment was performed for correction of the arch width discrepancy and deep overbite. A self-ligation system and wide-width arch form wire were used during the treatment to expand the arch width. After 30 months of phase II treatment, the alignment of the dental arch and stable molar occlusion was achieved. Function and occlusion remained stable with a Class I canine and molar relationship, and a normal overjet/overbite was maintained after 9.4 years of retainer use. In MBS patients, it is important to achieve an accurate early diagnosis, and implement a multidisciplinary treatment approach and long-term retention and follow-up.

슬롯출구 상류면의 상승과 하강에 따른 막냉각 특성 (Film Cooling Characteristics with Sunk or Lifted Upstream Wall)

  • 노석만;손창호;이근식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.377-381
    • /
    • 2001
  • Film cooling characteristics has been investigated numerically with the aid of FLUENT software for the sunk or the lifted upstream wall from the slot injection exit. In this study, with the fixed blowing ratio of 1 and the fixed coolant injection angle of $30^{\circ}$, the downstream flow field and the downstream temperature field were examined in terms of velocity vector, turbulent kinetic energy, temperature contours, and downstream wall temperature. Upstream wall was sunk or lifted from 1d to 5d(d=slot width). The result shows that the up-Id upstream wall has the best film cooling performance. This is due to the fact that the up-1d upstream wall configuration reduces velocity gradient just enough to minimize the turbulent mixing between the mainstream and the coolant just off the slot exit.

  • PDF

ROLL CENTER ANALYSIS OF A HALF-CAR MODEL USING POLE FOR SMALL DISPLACEMENT

  • Lee, J.K.;Shim, J.K.
    • International Journal of Automotive Technology
    • /
    • 제7권7호
    • /
    • pp.833-839
    • /
    • 2006
  • In this paper, roll behavior of three planar half car models are compared. The first model is a simple model whose contact point between a wheel and the ground is assumed to be fixed with a revolute joint. The second model is a modified model of the fIrst model, whose wheel tread width can vary. In this model, the instant center of a wheel with respect to the ground, which is crucial to find the roll center, is assumed to be at the contact point of a wheel and the ground. The last model uses the pole of a wheel with respect to the ground for small displacement as the instant center of a wheel with respect to the ground. Loci of the center of gravity point, the fixed and the moving centrodes which are traces of roll center position in the ground and the body frame respectively, wheel contact points, and instant centers of a wheel with respect to the ground are calculated.

고정성보철물 장착환자 및 치주질환 이환자를 위한 잇솔의 식모에 관한 연구 (A STUDY ON THE CONFIGURATION OF THE BRISTLE FOR THE PROSTHETIC AND PERIODONTALLY INVOLVED PATIENT)

  • 이재봉
    • 대한치과보철학회지
    • /
    • 제36권6호
    • /
    • pp.867-877
    • /
    • 1998
  • The purpose of this study was to investigate the ideal locations and dimensions of bristles for the patients who were installed with fixed prostheses and severely involved periodontitis. The models of 16 pts were analysed and the resullts were as follows: 1. There were no tooth brushes in the market, which were proper for the patients who were installed with fixed prostheses and had severely periodontally involved teeth. 2. The neck portion of the tooth brush should be narrow as possblly. 3. The size of tooth brush should be analyzed by the size of arch. 4. The width of tooth brush should be analyzed by the degree of bone recession. 5. The custom made tooth brush may be ideal, if possible.

  • PDF

Polymeric Waveguides with Bragg Gratings in the Middle of the Core Layer

  • Jeong, In-Soek;Park, Hae-Ryeong;Lee, Sang-Won;Lee, Myung-Hyun
    • Journal of the Optical Society of Korea
    • /
    • 제13권2호
    • /
    • pp.294-298
    • /
    • 2009
  • In this paper we proposed a new Bragg grating waveguide in order to improve reflectivity and to achieve compactness. Bragg gratings with various thicknesses were engraved in the middle of the core layer with a length of 3 mm. For the sake of cost-effectiveness, the $3^{rd}$ order Bragg grating waveguides were fabricated via conventional photolithography. The maximum reflectivities for the fixed width waveguide of $6{\mu}m$ with the 0.1 and $0.3{\mu}m$-thick Bragg gratings were, -13.14 and -6.25 dB, respectively, and the Bragg wavelengths were 1562.28, 1564.10 nm, respectively. A slight increase in the Bragg grating thickness can result in a remarkable reduction in the length of the Bragg grating waveguide with a fixed reflectivity.

Size-Independent Caption Extraction for Korean Captions with Edge Connected Components

  • Jung, Je-Hee;Kim, Jaekwang;Lee, Jee-Hyong
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제12권4호
    • /
    • pp.308-318
    • /
    • 2012
  • Captions include information which relates to the images. In order to obtain the information in the captions, text extraction methods from images have been developed. However, most existing methods can be applied to captions with a fixed height or stroke width using fixed pixel-size or block-size operators which are derived from morphological supposition. We propose an edge connected components based method that can extract Korean captions that are composed of various sizes and fonts. We analyze the properties of edge connected components embedding captions and build a decision tree which discriminates edge connected components which include captions from ones which do not. The images for the experiment are collected from broadcast programs such as documentaries and news programs which include captions with various heights and fonts. We evaluate our proposed method by comparing the performance of the latent caption area extraction. The experiment shows that the proposed method can efficiently extract various sizes of Korean captions.

초파리 복안(複眼)의 전자(電子) 현미경적(顯微鏡的) 연구(硏究) (An Electron Microscopy of the Compound eye in Drosophila melanogaster)

  • 백경기
    • Applied Microscopy
    • /
    • 제1권1호
    • /
    • pp.27-34
    • /
    • 1969
  • The compound eyes of the adult Drosophila melanogaster were. fixed in 1.25 per cent glutaraldehyde and 1 per cent osmium tetroxide buffered with sodium cacodylate at pH 7.2. Double fixed specimens were dehydrated using the alcohol series and embedded in Epon 812. They were sectioned with porter blum and JUM 5B ultra-microtome and then stained with lead hydrooxide and uranyl acetate. All thin sections were examined with Hitachi HS-7 or HU-11 electron microscope. The rhabdomere of the compound eye is composed of numerous microvilli packed, arranged, and projected from inner edge of each retinal cell. Each microvillus consisted of a centrum, about $82{\AA}$ in diameter, surrounded by the substances, about $105{\AA}$ in width, which were bounded with double membrane about $44{\AA}$ in thickness. In each inner edge of the microvilli, there was a cylinder, about $175{\AA}$ in diameter, in parallel with retinal cells, which contained a cylindrical axis about $583{\AA}$ in diameter. The surface of the outer edges .of .the microvilli was bounded with reticullar substances about $500{\AA}$ in thickness.

  • PDF