• 제목/요약/키워드: fixed-effect

검색결과 2,885건 처리시간 0.027초

Immediate fixed partial denture after tooth extraction in patients with systemic diseases: A clinical report

  • Kang, Hyun Sun;Lee, Su Young
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권6호
    • /
    • pp.511-514
    • /
    • 2016
  • For patients with systemic diseases who face difficulties visiting dental clinics, wearing fixed partial denture in the anterior region on the same day of tooth extraction can reduce the total period of treatment and the number of visits, as well as post-treatment psychological effect on the patient.

An analysis of the effect of the inequality of income to the inequality of health: Using Panel Analysis of the OECD Health data from 1980 to 2013

  • Lee, Hun-Hee;Lee, Jung-Seo
    • 한국컴퓨터정보학회논문지
    • /
    • 제22권10호
    • /
    • pp.145-150
    • /
    • 2017
  • This study aims to analyze panel data using OECD Health data of 34 years to examine how significant the inequality of income is to the inequality of health. The data was from OECD's pooled Health data of 32 countries from 1980 to 2013. The process of determining analysis model was as follows; First, through the descriptive statistics, we examined averages and standard deviation of variables. Second, Lagrange multiplier test has done. Third, through the F-test, we compared Least squares method and Fixed effect model. Lastly, by Hausman test, we determined proper model and examined effective factor using the model. As a result, rather than Pooled OLS Model, Fixed Effect Model was shown as effective in order to consider the characteristics of individual in the panel. The results are as follows: First, as relative poverty rate(${\beta}=-19.264$, p<.01) grows, people's life expectancy decreases. Second, as the rate of smoking(${\beta}=-.125$, p<.05) and the rate of unemployment (${\beta}=-.081$, p<.01) grows, people's life expectancy decreases. Third, as health expenditure(${\beta}=.414$, p<.01) shares more amount of GDP and as the number of hospital beds(${\beta}=-.190$, p<.05) grows, people's life expectancy increases.

고정 부하 수축시 기록한 표면근전도 신호에 대한 노화의 영향 (Influence of Aging on Surface EMG Signals Generated Under Sustained Fixed Load Contraction)

  • 이진;김성환
    • 전기학회논문지
    • /
    • 제59권8호
    • /
    • pp.1497-1505
    • /
    • 2010
  • The present study was performed to investigate the effect of aging on muscular activity of older subjects under the condition of fixed load muscle contraction. SEMG signals were recorded from old (46 women) and young (45 women) groups performing sustained isometric elbow flexion contraction with a fixed load during 30 seconds. Linear regression and mean square error (MSE) analysis with four characteristic variables (ARV, RMS, MDF, MNF) were used to compare the age-related difference (of local muscle fatigue and fluctuation of the amplitude and frequency) in the SEMG signal. The main results can be summarized as follows: During sustained muscle contraction with a fixed load: i) the MSE values of amplitude (ARV, RMS) and frequency (MDF, MNF) variables were more than 30% higher for the young than for the old adults; ii) the measures of local muscle fatigue (slope of the MDF and MNF) indicated greater fatigue in the old; and iii) the rate of increase of the SEMG amplitude was higher for the young than the old.

고정압이 중공축 내경의 가공정밀도에 미치는 영향 (Influence of fixed pressure on the machining accuracy of inner diameter of hollow shaft)

  • 전영석;장성민;강신길
    • 한국생산제조학회지
    • /
    • 제19권3호
    • /
    • pp.381-387
    • /
    • 2010
  • This paper presents a study of the influence of fixed pressure in turning. The effect of roundness error and diameter deformation were studied with respect to the fixed pressure applied inside the cylindrical work piece made by boring tool in CNC lathe. The boring tool used in this study is a tungsten carbide coated. The material of workpiece is SM45C and the machining method is dry cutting. Cutting conditions as cutting speed, feed rate and depth of cut are constant. Finally, the change of fixed pressure had influence on the roundness error and diameter deformation.

EU 내 단일통화(Euro) 사용이 회원국들 간 수출.입에 미치는 효과 분석 (An Export and Import Effect Analysis among the Eurozone Members of Using the Euro)

  • 강보경;최영두
    • 통상정보연구
    • /
    • 제14권3호
    • /
    • pp.31-47
    • /
    • 2012
  • 1999년 유로존(Eurozone)은 단일통화 출현을 목표로 출범하였다. 유로화(Euro)의 사용은 회원국들에게 있어 GDP의 약 1%에 이르는 환전비용과 환위험 관리비용을 제거하였다. 또한 안정적인 역내 물가수준을 유지할 수 있었고 저금리 기조를 유지하며 투자와 고용의 촉진이 이루어졌다. 유로화의 국제적 위상에서도 세계 외환보유고 비중이 2010년 기준 26.9%로 제2위의 기축통화국으로 자리매김하였다. 역내 회원국들 간에도 환율 고정에 따른 환율 위험을 떨어드려 투자와 경제성장을 유도하였다. 특히나 금융시장에서는 거래비용의 감소로 유로화의 수요가 증가하였고 교역에서도 대금지급수단으로 유로화가 사용됨으로써 교역증가로 인한 단일시장 효과를 유발하고 있다. 본 연구에서는 EU내 단일통화 사용이 회원국들 간의 수출과 수입에 미치는 파급효과에 대해 임의효과모형(random effect estimation)과 고정효과모형(fixed effect estimation)으로 분석해 보았다.

  • PDF

변량계수모형의 식이요법 실험자료에 관한 사례연구 (A case study on the random coefficient model for diet experimental data)

  • 조진남;백재욱
    • Journal of the Korean Data and Information Science Society
    • /
    • 제20권5호
    • /
    • pp.787-796
    • /
    • 2009
  • 이 논문에서는 반복측정치에 대한 분석모형 중, 혼합모형의 일종인 변량계수모형에 대하여 이론적으로 고찰한다. 특히 혼합모형의 설정, 모수 추정에 대하여 통계적으로 고찰하고 변량계수모형에 대한 가능한 모형을 열거하며, 그에 따르는 추정과 검정을 논의한다. 사례연구로 식이요법자료를 대상으로 가능한 변량계수모형을 적용하여 추정 및 검정을 실시한 결과, 고정인자인 사전값, 처리, 키 및 시간들의 인자는 체중감소에 대단히 유의함을 보여주었지만, 나이와 혈압은 유의하지 않았다. 처리효과에 있어서는 식이요법과 운동을 병행했을 때의 처리가 식이요법만 실시했을 때의 처리보다 체중이 더 감소했음을 알 수 있으며, 시간에 따른 체중감소의 효과는 삼차함수의 관계가 성립된다. 변량인자로는 개체효과는 유의하며 개체별 시간에 대한 교호작용의 효과는 차수가 높아질수록 급속도로 감소하여 3차 함수 관계가 적절한 모형으로 최종 선택되었다.

  • PDF

EFFECT OF NUMBER OF IMPLANTS AND CANTILEVER DESIGN ON STRESS DISTRIBUTION IN THREE-UNIT FIXED PARTIAL DENTURES: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS

  • Park, Ji-Hyun;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • 대한치과보철학회지
    • /
    • 제46권3호
    • /
    • pp.290-297
    • /
    • 2008
  • STATEMENT OF PROBLEM: Implant-supported fixed cantilever prostheses are influenced by various biomechanical factors. The information that shows the effect of implant number and position of cantilever on stress in the supporting bone is limited. PURPOSE: The purpose of this study was to investigate the effect of implant number variation and the effect of 2 different cantilever types on stress distribution in the supporting bone, using 3-dimensional finite element analysis. MATERIAL AND METHODS: A 3-D FE model of a mandibular section of bone with a missing second premolar, first molar, and second molar was developed. $4.1{\times}10$ mm screw-type dental implant was selected. 4.0 mm height solid abutments were fixed over all implant fixtures. Type III gold alloy was selected for implant-supported fixed prostheses. For mesial cantilever test, model 1-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 1-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 1-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with mesial cantilever were simulated. And then, 155N oblique force was applied to the buccal cusp of second premolar. For distal cantilever test, model 2-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 2-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 2-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with distal cantilever were simulated. And then, 206N oblique force was applied to the buccal cusp of second premolar. The implant and superstructure were simulated in finite element software(Pro/Engineer wildfire 2.0). The stress values were observed with the maximum von Mises stresses. RESULTS: Among the models without a cantilever, model 1-1 and 2-1 which had three implants, showed lower stress than model 1-2 and 2-2 which had two implants. Although model 2-1 was applied with 206N, it showed lower stress than model 1-2 which was applied with 155N. In models that implant positions of models were same, the amount of applied occlusal load largely influenced the maximum von Mises stress. Model 1-1, 1-2 and 1-3, which were loaded with 155N, showed less stress than corresponding model 2-1, 2-2 and 2- 3 which were loaded with 206N. For the same number of implants, the existence of a cantilever induced the obvious increase of maximum stress. Model 1-3 and 2-3 which had a cantilever, showed much higher stress than the others which had no cantilever. In all models, the von Mises stresses were concentrated at the cortical bone around the cervical region of the implants. Meanwhile, in model 1-1, 1-2 and 1-3, which were loaded on second premolar position, the first premolar participated in stress distribution. First premolars of model 2-1, 2-2 and 2-3 did not participate in stress distribution. CONCLUSION: 1. The more implants supported, the less stress was induced, regardless of applied occlusal loads. 2. The maximum von Mises stress in the bone of the implant-supported three unit fixed dental prosthesis with a mesial cantilever was 1.38 times that with a central pontic. The maximum von Mises stress in the bone of the implant-supported three-unit fixed dental prosthesis with a distal cantilever was 1.59 times that with a central pontic. 3. A distal cantilever induced larger stress in the bone than a mesial cantilever. 4. A adjacent tooth which contacts implant-supported fixed prosthesis participated in the stress distribution.

고정식 교정 장치물 장착후 타액내 미생물과 면역 글로블린 A의 변화 (A Longitudinal Study on Salivary Microorgnisms and Immunoglobulin A after Delivery of Fixed Orthodontic Appliances)

  • 이현경;이광호;이승우
    • Journal of Oral Medicine and Pain
    • /
    • 제23권2호
    • /
    • pp.109-117
    • /
    • 1998
  • Fixed orthodontic appliances for the treatment of malocclusion has iatrogenic side effect such as demineralization of enamel, gingivitix and gingival hyperplasia. The purpose of this study is to longitudinally investigate the salivary microorganisms and immunoglobulin A after delivery of fixed orthodontic appliances for 10 months. Eight orthodontic patients were included in this study and the author has investigated the numbers of general bacteria, Streptococcus mutans Staphylococcus aureus and concentration of immunoglobulin A from unstimulated whole saliva. The author examined these parameters at prebracketing, 1 month after, 4 months after, 7 months after and 10 months after delivery of fixed orthodontic appliances. The obtained results were as follows : There were significant increases in the number of salivary general bacteria, Streptococcus mutans and Staphylococcus aureus after delivery of fixed orthodontic appliances The numbers of general bacteria were significantly increased at 1 month after (p<005), 4 months after (p<0.05), 7 months after (p<0.01), compared with prebracketing. However it showed no difference at 10 month after compared with 7 months after bracketing. The Numbers of Staphylococcus aureus were significantly increased at 1 month after (p<0.05), 4 months after(p<0.01), 7 month(p<0.01), compared with prebracketing. However it showed decreasing pattern at 10 months after compared with 7 months after bracketing. There was no significant difference in the concentration of immunoglobulin A after delivery of fixed orthodontic appliances.

  • PDF

패널자료를 이용한 노동조합의 임금효과 분석 (A Longitudinal Analysis of the Union Effect on the Wages)

  • 조동훈
    • 노동경제논집
    • /
    • 제31권2호
    • /
    • pp.103-128
    • /
    • 2008
  • 본 연구는 "한국노동패널조사" 자료를 사용하여 노동조합이 임금에 미치는 효과를 패널 분석하였다. 횡단면 분석을 통하여 구한 노동조합이 임금상승에 미치는 효과는 약 4.6%로 추정되었다. 고정효과 모델을 통하여 추정된 노조의 임금상승효과는 약 2.1%로 상당히 그 효과가 감소하였음을 알 수 있다. 따라서 보이지 않는 근로자의 특성과 노조가 있는 기업에 종사하며 노동조합에 가입하는 의사결정과 양(+)의 상관관계가 존재함을 유추해 볼 수 있으며 기존의 횡단면 분석의 연구 결과가 상당 부분 상향 편의되었음을 유추해 볼 수 있다.

  • PDF