• Title/Summary/Keyword: fixed prosthesis

Search Result 343, Processing Time 0.02 seconds

Three-dimensional finite element analysis of stress distribution for different implant thread slope and implant angulation (임플란트 나사선 경사각과 식립 각도에 따른 3차원 유한요소 응력분석)

  • Seo, Young-Hun;Lim, Hyun-Pil;Yun, Kwi-Dug;Yoon, Suk-Ja;Vang, Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • Purpose: The purpose of this study was to find an inclination slope of the screw thread that is favorable in distributing the stresses to alveolar bone by using three dimensional finite element analysis. Materials and methods: Three types modelling changed implant thread with fixed pitch of 0.8 mm is the single thread implant with $3.8^{\circ}$ inclination, double thread implant with $7.7^{\circ}$ inclination and the triple thread implant with $11.5^{\circ}$ inclination. And three types implant angulation is the $0^{\circ}$, $10^{\circ}$ and $15^{\circ}$ on alveolar bone. The 9 modelling fabricated for three dimensional finite element analysis that restored prosthesis crown. The crown center applied on 200 N vertical load and $15^{\circ}$ tilting load. Results: 1. The more tilting of implant angulation, the more Von-Mises stress and Max principal stress is increasing. 2. Von-Mises stress and Max principal stress is increasing when applied $15^{\circ}$ tilting load than vertical load on the bone. 3. When the number of thread increased, the amount of Von-Mises stress, Max principal stress was reduced since the generated stress was effectively distributed. 4. Since the maximum principal stress affects on the alveolar bone can influence deeply on the longevity of the implants. When comparing the magnitude of the maximum principal stress, the triple thread implant had a least amount of stress. This shows that the triple thread implant gave a best result. Conclusion: A triple thread implant to increase in the thread slope inclination and number of thread is more effective on the distribution of stress than the single and double thread implants especially, implant angulation is more tilting than $10^{\circ}$ on alveolar bone. Thus, effective combination of thread number and thread slope inclination can help prolonging the longevity of implant.

Long-Term Survival Analysis of Unicompartmental Knee Arthroplasty (슬관절 부분 치환술의 장기 생존 분석)

  • Park, Cheol Hee;Lee, Ho Jin;Son, Hyuck Sung;Bae, Dae Kyung;Song, Sang Jun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.5
    • /
    • pp.427-434
    • /
    • 2019
  • Purpose: This study evaluated the long term clinical and radiographic results and the survival rates of unicompartmental knee arthroplasty (UKA). In addition, the factors affecting the survival of the procedure were analyzed and the survival curve was compared according to the affecting factors. Materials and Methods: Ninety-nine cases of UKA performed between December 1982 and January 1996 were involved: 10 cases with Modular II, 44 cases with Microloc, and 45 cases with Allegretto prostheses. The mean follow-up period was 16.5 years. Clinically, the hospital for special surgery (HSS) scoring system and the range of motion (ROM) were evaluated. Radiographically, the femorotibial angle (FTA) was measured. The survival rate was analyzed using the Kaplan-Meier method. Cox regression analysis was used to identify the factors affecting the survival according to age, sex, body mass index, preoperative diagnosis, and type of implant. The Kaplan-Meier survival curves were compared according to the factors affecting the survival of UKA. Results: The overall average HSS score and ROM was 57.7 and 134.3° preoperatively, 92.7 and 138.4° at 1 year postoperatively, and 79.1 and 138.4° at the last follow-up (p<0.001, respectively). The overall average FTA was varus 0.8° preoperatively, valgus 4.1° at postoperative 2 weeks, and valgus 3.0° at the last follow-up. The overall 5-, 10-, 15- and 20-year survival rates were 91.8%, 82.9%, 71.0%, and 67.0%, respectively. The factors affecting the survival were the age and type of implant. The risk of the failure decreased with age (hazard ratio=0.933). The Microloc group was more hazardous than the other prostheses (hazard ratio=0.202, 0.430, respectively). The survival curve in the patients below 60 years of age was significantly lower than those of the patients over 60 years of age (p=0.003); the survival curve of the Microloc group was lower compared to the Modular II and Allegretto groups (p=0.025). Conclusion: The long-term clinical and radiographic results and survival of UKA using old fixed bearing prostheses were satisfactory. The selection of appropriate patient and prosthesis will be important for the long term survival of the UKA procedure.

A three-dimensional finite-element analysis of influence of splinting in mandibular posterior implants (스프린팅이 하악 구치부 임플랜트 보철물의 응력분산에 미치는 영향에 관한 삼차원 유한요소분석 연구)

  • Baik, Sang-Hyun;Jang, Ik-Tae;Kim, Sung-Kyun;Koak, Jai-Young;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.157-168
    • /
    • 2008
  • Statement of problem: Over the past two decades, implant supported fixed prosthesis have been widely used. However, there are few studies conducted systematically and intensively on the splinting effect of implant systems in mandible. Purpose: The purpose of this study was to investigate the changes in stress distributions in the mandibular implants with splinting or non-splinting crowns by performing finite element analysis. Materials and methods: Cortical and cancellous bone were modeled as homogeneous, transversely isotropic, linearly elastic. Perfect bonding was assumed at all interfaces. Implant models were classified as follows. Group 1: $Br{{\aa}}nemark$ length 8.5mm 13mm splinting type Group 2: $Br{{\aa}}nemark$ length 8.5mm 13mm Non-splinting type Group 3: ITI length 8.5mm 13mm splinting type Group 4: ITI length 8.5mm 13mm Non-splinting type An load of 100N was applied vertically and horizontally. Stress levels were calculated using von Mises stresses values. Results: 1. The stress distribution and maximum von Mises stress of two-length implants (8.5mm, 13mm) was similar. 2. The stress of vertical load concentrated on mesial side of implant while the stress of horizontal load was distributed on both side of implant. 3. Stress of internal connection type was spreading through abutment screw but the stress of external connection type was concentrated on cortical bone level. 4. Degree of stress reduction was higher in the external connection type than in the internal connection type.