• 제목/요약/키워드: fixation order

검색결과 213건 처리시간 0.023초

Surgical Management of a Mandible Subcondylar Fracture

  • Kang, Dong Hee
    • Archives of Plastic Surgery
    • /
    • 제39권4호
    • /
    • pp.284-290
    • /
    • 2012
  • Open reduction and anatomic reduction can create better function for the temporomandibular joint, compared with closed treatment in mandible fracture surgery. Therefore, the double miniplate fixation technique via mini-retromandibular incision was used in order to make the most stable fixation when performing subcondylar fracture surgery. Those approaches provide good visualization of the subcondyle from the posterior edge of the ramus, allow the surgeon to work perpendicularly to the fracture, and enable direct fracture management. Understanding the biomechanical load in the fixation of subcondylar fractures is also necessary in order to optimize fixation methods. Therefore, we measured the biomechanical loads of four different plate fixation techniques in the experimental model regarding mandibular subcondylar fractures. It was found that the loads measured in the two-plate fixation group with one dynamic compression plate (DCP) and one adaption plate showed the highest deformation and failure loads among the four fixation groups. The loads measured in the one DCP plate fixation group showed higher deformation and failure loads than the loads measured in the two adaption plate fixation group. Therefore, we conclude that the selection of the high profile plate (DCP) is also important in order to create a stable load in the subcondylar fracture.

STUDY ON THE VISUAL COGNITIVE CHARACTERISTICS BY THE FIXATION POINT ANALYSIS USING THE EYE MARK RECORDER

  • Yamanoto, Satoshi;Yamaoka, Toshiki;Matsunobe, Takuo
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2001년도 춘계학술대회 논문집
    • /
    • pp.20-25
    • /
    • 2001
  • In recent years, the concern about a user center design in increasing, and it's needed to task a user's visual cognitive characteristics for information presentation. Then this study aims to grasp user's cognitive characteristics about the information presentation by analyzing the fixation points. In the experiment, actually subject operated a copy machine. Recorded the fixation point movement of the operation panel by the eye mark recorder. Analysis examined the screen interface of the operation panel from the field of a fixation point trace. The top down type fixation oder by experience or the context became clear as a result. Furthermore, the difference of the fixation order by skill level was also examined. In this study, it was assumed that to grasp the visual cognitive characteristics becomes the key of efficient information.

  • PDF

레이온 직물의 Wet-Fixation에 의한 DP가공에 관한 연구(II) -처리온도 및 시간의 영향- (A study on the Durable Press finish by Wet-Fixation Process for Rayon Fabrics (II) - Effect of Treatment Temperature and Time -)

  • 허윤숙;김은애
    • 한국의류학회지
    • /
    • 제13권4호
    • /
    • pp.357-369
    • /
    • 1989
  • The purpose of this study was to investigate the effects of treatment temperature and time on the, of easy-care and strength properties of the wet fixation processed rayon fabrics. Viscose rayon fabrics were treated with mixed resins of melamine formaldehyde (MF) and DMDHEU by one bath and two bath wet fixation processes. The MF/DMDHEU mixed resin concentrations were 50/100, 50/150, 100/100 and 100/150(g/1). Magnasium chloride was used as a catalyst. The wet fixation conditions were 24hrs at room temperature,20 mins at $75^{\circ}C$ and 5 mins at $105^{\circ}C$ Wet fixation processed fabrics did not show the difference in the resin add-one, DP ratings and wrinkle recovery angles by the different treatment temperatures and times. DP ratings were in the order of $105^{\circ}C>75^{\circ}C>room$ temp, in one bath and two bath wet fixation. Breaking and tearing strength of one bath processed fabrics showed in the order of $75^{\circ}C>room\;temp>105^{\circ}C$ The breaking strength of two bath processed fabrics showed in the order of $105^{\circ}C>75^{\circ}C>room$ temp. Tearing strength showed in the order of $75^{\circ}c>105^{\circ}C>room$ temp. Abrasion resistances were in the order of $75^{\circ}C>105^{\circ}C>room$ temp. in one bath and two bath processes.

  • PDF

새로운 수용성(水溶性) 방부방충제(防腐防蟲劑)의 재중(材中) 정착성(定着性)에 관한 계면전기화학적(界面電氣化學的) 특성(特性) (Surface Electrochemical Study on the Fixation Properties of New Water-borne Preservatives in Red Pine)

  • 김영숙
    • Journal of the Korean Wood Science and Technology
    • /
    • 제24권4호
    • /
    • pp.93-99
    • /
    • 1996
  • In order to investigate the extent of fixation of new water-borne preservatives in blocks of pinus densiflora sapwoods the streaming potential through the column with preservative treated wood was measured at various conditions. The rates of leachability of ingredients in the treated wood were estimated by the measurement of electric conductivity of the solution with the leached components. The solution was also analyzed by Atomic absorption spectrophotometer (AA). As a results, the experimental data indicated that the fixation of CCB, CCFZ and ACQ in wood were relatively unstable. The fixation rates of CCB, CCFZ were improved by increasing heat and drying time. The amounts of the leached ingredients were apparently higher in CCB and CCFZ than in CCA, while the rate of leaching of ACQ was not changed at various drying temperature.

  • PDF

멜라민과 포르말린 혼합액의 첨 가제들이 실크 생사의 세리신 정착에 미치는 영향 (The Influence of Additives Added to the Melamine and Formalin Mixtures on Sericin Fixation of Raw Silk Fibers)

  • 박건용
    • 한국산학기술학회논문지
    • /
    • 제10권2호
    • /
    • pp.412-417
    • /
    • 2009
  • 실크 생사의 세리신 정착을 보다 효과적으로 하기위해 멜라민과 포르말린의 혼합액에 각종 첨가제를 첨가했을 때 첨가제가 세리신 정착에 미치는 영향을 살펴보았다. 멜라민과 포르말린의 혼합액으로 세리신을 정착할 때 수분침투 기능이 있는 계면활성제로 전처리라고 수세하지 않은 경우 견고한 정착이 이루어졌고, 정착액에 과산화수소를 첨가한 경우 정착 효과가 크게 떨어지면서 단사 간에 접착하는 문제가 발생했고, 하이드로를 첨가하여 $60^{\circ}C$에서 정착하는 경우에는 표백과 동시에 세리신 정착이 가능함을 확인했다. 낮은 농도의 수산화나트륨을 첨가한 알칼리 조건에서 멜라민을 추가함으로써 매우 견고한 세리신 정착 결과를 얻었으나 염산과 메탄을 추가는 정착에 그다지 효과적이지 못했고, 염화마그네슘 추가는 오히려 세리신 정착 견고성을 크게 저하시켰다.

성인 쇄골 간부 골절의 수술적 치료-골수강내 다발성 Steinmann핀 고정술과 재구성 금속판 고정술과의 비교- (Operative Treatment of the Clavicular Midshaft Fractures in Adult - A Comparison between Intramedullary Multiple Steinmann Pins Fixation and Reconstruction Plate Fixation -)

  • 이영국;구혜서
    • Clinics in Shoulder and Elbow
    • /
    • 제2권1호
    • /
    • pp.14-20
    • /
    • 1999
  • Purpose: Despite of the popular use of the reconstruction plate for the fixation of clavicular shaft fractures, some disadventages have been raised such as long period of immobilization, long skin incision, loosening of plate and screws, and increased chance of nonunion due to severe periosteal injury. Thus, the authors have performed intramedullary multiple Steinmann pins fixation that could reduce the disadvantages of plate fixation in order to compare the treatment results between the two groups. Materials & Methods: From 1994. Jan. to 1997. Dec. the department of orthopaedic surgery of the Kwak's hospital treated operatively for 56 cases of the clavicular shaft fractures in adult. 39 cases of them were treated with the plate fixation and 17 cases with the intramedullary multiple Steinmann pins fixation(SP group). Reconstruction plates(Plate group) were used for 26 out of 39 patients treated with plate fixation. Among the Plate group and SP group, each 15 cases were selected by age and sex and compared each other according to the bone union time, union rate, complication, and functional results. The follow-up period was 12 months at the shortest and 48 months at the longest and the average was 16 months. Results: The Plate group showed that the bone union time was 7 weeks and the bone union rate was 93%. The SP group showed 6.5 weeks and 100% respectively. In complication, the Plate group had 1 case of loosening of plate and screws and delayed union; SP group had 1 case of pin migration. The functional results according to Kang's criteria, 87% of the Plate group and 93% of the SP group showed good or excellent. Conclusion : The SP group showed very comparable results in terms of the bone union time, bone union rate, complication, and functional results comparing to the Plate group. The intramedullary multiple Steinmann pins fixation showed several advantages over the reconstruction plate fixation, which were simple operative technique, easy removal of pins, being able to perform immediate postoperative full range of motion exercise. Therefore, the intramedullary multiple Steinmann pins fixation is thought to be one of the useful operative techniques in treatment of the clavicular shaft fractures in adult.

  • PDF

Analysis of Sternal Fixation Results According to Plate Type in Sternal Fracture

  • Byun, Chun Sung;Park, Il Hwan;Hwang, Wan Jin;Lee, Yeiwon;Cho, Hyun Min
    • Journal of Chest Surgery
    • /
    • 제49권5호
    • /
    • pp.361-365
    • /
    • 2016
  • Background: Sternal fractures are relatively rare, and caused mainly by blunt anterior chest wall trauma. In most cases, sternal fractures are treated conservatively. However, if the patient exhibits problematic symptoms such as intractable chest wall pain or bony crepitus due to sternal instability, surgical correction is indicated. But no consensus exists regarding the most appropriate surgical method. We analyzed the results of surgical fixation in cases of sternal fracture in order to identify which surgical method led to the best outcomes. Methods: We retrospectively reviewed the medical records of patients with sternal fractures from December 2008 to December 2011, and found 19 patients who underwent open reduction and internal fixation of the sternum with a longitudinal plate (L-group) or a T-shaped plate (T-group). We investigated patients' characteristics, clinical details regarding each case of chest trauma, the presence of other associated injuries, the type of open reduction and fixation, whether a combined operation was performed, and postoperative complications. Results: Of the 19 patients, 10 patients (52.6%) were male, and their average age was 56.8 years (range, 32 to 82 years). Seven patients (36.8%) had isolated sternal fractures, while 12 (63.2%) had other associated injuries. Seven patients (36.8%) were in the L-group and 12 patients (63.2%) were in the T-group. Three patients in the L-group (42.9%) showed a loosening of the fixation. In all patients in the T-group, the fracture exhibited stable alignment. Conclusion: Open reduction and internal fixation with a T-shaped plate in sternal fractures is a safer and more efficient treatment method than treatment with a longitudinal plate, especially in patients with a severely displaced sternum or anterior flail chest, than a longitudinal plate.

반연속식 운전에서 Chlorella sp. HA-1의 이산화탄소 고정화 특성 (The Characteristics of Carbon Dioxide Fixation by Chlorella sp. HA-1 in Semi-continuous Operation)

  • 이재영;강현아;양지원
    • KSBB Journal
    • /
    • 제14권6호
    • /
    • pp.742-746
    • /
    • 1999
  • 새로운 형태의 내부조사형 광생물반응기에서 Chlorella sp. HA-1의 이산화탄소 고정화 특성을 살펴보았다. 높은 이산화탄소 농도에서 균체를 적응시켜 10%와 20%(v/v) 이산화탄소 농도 모두에서 내성을 가지도록 하였다. 그리고 조도, 초기균체농도, pH 등을 조절하여 이산화탄소 고정화양, 372 $gCO_2/m^2{\cdot}day$을 얻었다. 또한 장시간 동안 지속적으로 배출되는 이산화탄소를 제거하기 위한 운전 방법으로 반연속식 배양방법을 사용하여 희석비를 0.1씩 증가시켰을 때 각 단계마다 균체성장속도를 일정하게 유지하는 결과를 얻었다.

  • PDF

Review of Advances in Biological $CO_2$Mitigation Technology

  • Lee, Jin-Suk;Lee, Joon-Pyo
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제8권6호
    • /
    • pp.354-359
    • /
    • 2003
  • $CO_2$fixation by microalgae has emerged as a promising option for $CO_2$mitigation. In-tensive research work has been carried out to develop a feasible system for removing $CO_2$from industrial exhaust gases. However, there are still several challenging points to overcome in order to make the process more practical. In this paper, recent research activities on three key technologies of biological $CO_2$fixation, an identification of a suitable algal strain, development of high efficient photobioreactor and utilization of algal cells produced, are described. Finally the barriers, progress, and prospects of commercially developing a biological $CO_2$fixation process are summarized.

Analysis of Mechanical Fixation Made of Aluminum Alloy in an Axial Flux Permanent Magnet Machine

  • Lee, Jiyoung;Park, Byounggung;Koo, Daehyun
    • Journal of Magnetics
    • /
    • 제19권3호
    • /
    • pp.309-313
    • /
    • 2014
  • This paper presents an eddy current loss analysis of a Mechanical Fixation (MF) made of 6061 aluminum alloy, which is used for an NS type double-rotor single-stator axial flux permanent magnet machine. The prototype MF made of aluminum alloy shows good mechanical performance, but poor electro-magnetic performance, since the machine's efficiency can decrease because of eddy current loss in the MF. In order to prevent efficiency decrease, a modification of the MF structure is also introduced. Three-dimensional finite element analysis (FEA) is used for magnetic field analysis, and eddy current losses are computed. The analysis results are compared to, and verified by the test results.