• Title/Summary/Keyword: fireproof sealant

Search Result 2, Processing Time 0.015 seconds

Reforming of Expanded Graphite for Improving Fire Resistance of Fireproof Sealant (방화용 실란트의 내화성 향상을 위한 첨가제로서 팽창흑연의 개질)

  • Hong, In Kwon;Lee, Won Jae;Lim, Hyun Seok;Lee, Seung Bum
    • Applied Chemistry for Engineering
    • /
    • v.28 no.4
    • /
    • pp.437-441
    • /
    • 2017
  • This study was carried out to investigate the volumetric expansion ratio and hardness of expanded graphite after coating with various resins which were used as an additive of fireproof sealant. The coating thickness of the resin, which represents the coating rate, was dependent of the drying speed of the resin and the viscosity of the resin. Therefore the coating thickness was shown as follows: polyvinyl acetate > acrylic resin > urethane resin > water soluble latex. Furthermore, the volumetric expansion ratio was as follows: urethane resin > water soluble latex > acrylic resin > polyinyl acetate and the hardness was as follows: polyvinyl acetate resin > acrylic resin > water soluble latex > urethane resin. This showed that the volume of expansion was reduced by expansion, which was not covered by coating, but significantly increased by increasing hardness and allowed it to be used as a refractory addition. According to the response surface methodology, the optimized addition amount and stirring speed of acrylic resin were 37.6 wt% and 441.4 rpm, respectively.

A study for the test method of fire resistance construction sealant (방화용 실런트 성능 평가 방법 연구)

  • Ahn, Myung-Su;Jung, Jin-Young;Bae, Ki-Sun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.179-182
    • /
    • 2013
  • Many kinds of fire-stop sealants have been used for joint sealing, cable penetration part sealing and fireproof structure finishing etc in building sectors which need water-proofing and fire-stop properties. But, fire-stop sealant itself has no specific industry standards in Korea even though there are so many required properties for the application. So, in this study, for the evaluation, we adopted and applied UL standard 94(UL 94) which is commonly used for the fire retardant testing in inflammable materials like plastics and rubbers in electronics industry. In this study, we demonstrated fire resistance properties of each fire-stop sealants which varied with different formulation, thickness and origins available in Korea. Overall, fire stop sealant had better fire resistance performance than normal construction sealant. And the thicker the material, the better the fire resistance performance was. Because there is no national or industry guideline for fire stop sealant itself, each sealant products showed different level of performances under UL94 desigation. Even certain product had very poor fire proof propeties although it claims it can be used for the application.

  • PDF