• 제목/요약/키워드: fire-resistant performance

검색결과 122건 처리시간 0.027초

Structural performance of unprotected concrete-filled steel hollow sections in fire: A review and meta-analysis of available test data

  • Rush, David;Bisby, Luke;Jowsey, Allan;Melandinos, Athan;Lane, Barbara
    • Steel and Composite Structures
    • /
    • 제12권4호
    • /
    • pp.325-350
    • /
    • 2012
  • Concrete filled steel hollow structural sections (CFSs) are an efficient, sustainable, and attractive option for both ambient temperature and fire resistance design of columns in multi-storey buildings and are becoming increasingly common in modern construction practice around the world. Whilst the design of these sections at ambient temperatures is reasonably well understood, and models to predict the strength and failure modes of these elements at ambient temperatures correlate well with observations from tests, this appears not to be true in the case of fire resistant design. This paper reviews available data from furnace tests on CFS columns and assesses the statistical confidence in available fire resistance design models/approaches used in North America and Europe. This is done using a meta-analysis comparing the available experimental data from large-scale standard fire tests performed around the world against fire resistance predictions from design codes. It is shown that available design approaches carry a very large uncertainty of prediction, suggesting that they fail to properly account for fundamental aspects of the underlying thermal response and/or structural mechanics during fire. Current North American fire resistance design approaches for CFS columns are shown to be considerably less conservative, on average, than those used in Europe.

옥내용 뿜칠내화피복재의 촉진내구성 조건 설정 연구 (Development of Acceleration Duability test condition for Fireproof Spray-Application.)

  • 김대회;이건철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.170-171
    • /
    • 2014
  • The buildings constructed with steel structure is coated with certified fire resistive material to resist from fire. Coating materials lose their initial performances as time passes, so they need some maintenance. This study is covers standardization of the methods for assessing the durability of SFRM. In Korea, more than 90 percent of SFRM are used indoors. So This study is to decide proper test method through investigation and examination of effect factor to performance of fire-resistant structure and applicable test method.

  • PDF

옥내용 뿜칠내화피복재의 촉진내구성 조건 설정 연구(II) (Development of Acceleration Duability test condition for Fireproof Spray-Application(II).)

  • 김대회;이건철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.109-110
    • /
    • 2014
  • The buildings constructed with steel structure is coated with certified fire resistive material to resist from fire. Coating materials lose their initial performances as time passes, so they need some maintenance. This study is covers standardization of the methods for assessing the durability of SFRM. In Korea, more than 90 percent of SFRM are used indoors. So This study is to decide proper test method through investigation and examination of effect factor to performance of fire-resistant structure and applicable test method.

  • PDF

The fire-risks of cost-optimized steel structures: Fire-resistant and hot-rolled carbon steel

  • Garcia, Harkaitz;Cuadrado, Jesus;Biezma, Maria V.;Calderon, Inigo
    • Structural Engineering and Mechanics
    • /
    • 제78권1호
    • /
    • pp.67-75
    • /
    • 2021
  • This work studies the behaviour of a steel portal frame selection under fire exposure, considering both span lengths and fire exposure times as variables. Such structures combine carbon steel (S275), fireproof micro-alloyed steel (FR), and coatings of intumescent paint with variable thicknesses, improving thereby the flame retardant behaviour of the steel structure. Thus, the main contribution of this study is the optimization of the portal frames by combining both steels, analysing the resulting costs influence on the final dimensions. Besides, the topological optimization of each steel component within the structure is also defined, in accordance with the following variables: weather conditions, span, paint thickness, and cost of steel. The results mainly confirmed that using both FR and S275 grades with intumescent painting is the Pareto optimum when considering performance, feasibility and costs of such portal frames widely used for industrial facilities.

실내건축관련 소방(消防)규정과 방염(防炎)에 관한 연구 (A Study on Data Research for Fire Regulations and Fire Retardant in Interior Architecture)

  • 조성오;김용성
    • 한국실내디자인학회논문집
    • /
    • 제19권3호
    • /
    • pp.95-102
    • /
    • 2010
  • Recently, a grow in size and features of Interior construction work over the complex and The Fire-related regulations have been strengthened for the prevention of fire damage. This study is purpose to propose interior design, construction and supervision for the efficient and reasonable way throughout the fire-related laws are investigated in interior architecture. First, the interior of the building work will be based on actual use Fire-related Laws and Regulations have be investigated. Second, based on analysis of material and facilities by Application can be used in production by the data were applied to the present. Third, the international Fire and Flame Retardant Standards for investigating and reviewing the relevant laws, differences and characteristics of each country were analyzed. Fourth, the various fire-related issues of regulation and the application of relevant provisions in the field works, the law's standards, and improvements were identified by analysis. Fire-Related Laws and Building codes that Safety Administration of the Fire Services are divided into design, it comes to approval from the municipal authorities with concerns about the fire that will fit on the Fire Department's administrative procedures and operations is necessary to integrate operations. In conclusion, Fire-related business are divided into Minister of Land, Transport and Maritime Affairs and Ministry of Public Administration and Security. So, Both institutions is need to be the cooperative work. It is necessary to the field supervision. Because, Flame-resistant performance standards in the field works applied are too complex. Last, Establishment of fire-related regulations will enact by private organizations and the experts to participate.

건식화 P0SCO E&C Fire Board 공법 개발에 관한 연구 (A Study on the Development of a Dry P0SCO E&C Fire Board Method with High Fire Resistance)

  • 김우재
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.721-724
    • /
    • 2008
  • 국내 초고층 프로젝트의 증가에 따라 필연적으로 고강도 콘크리트의 사용이 증가되고 있다. 콘크리트의 강도가 증가됨에 따라 화재시 단면결손을 유발하는 폭렬의 경향성이 커지고, 콘크리트부재 내부의 온도를 현저하게 증가시키며 심각한 구조적 손상을 유발할 수 있다는 문제점이 대두되었고, 정부에서도 2008년 7월부터 고강도 콘크리트의 내화성능 관리기준을 시행하고 있다. 이에 국내 각 건설사들은 50MPa 이상의 고강도 콘크리트에 대하여 폭렬방지 대책을 수립 중에 있다. 본 연구소에서는 신축공사 및 리모델링공사에도 적용이 가능한 고강도 콘크리트 폭렬방지 공법인 PFB (Posco E&C Fire Board) 공법을 개발하여 지속적인 공법 개선에 노력하고 있다. 본 연구는 고강도 콘크리트 폭렬방지 대책으로 개발한 PFB 공법을 기존의 습식공법에서 현장적용성 및 경제성이 우수한 건식화 공법개발을 위한 기초 연구로 PF보드의 기초물성 평가, 3시간 내화시험 및 현장 적용위한 실시 상세 설계를 실시하여 당사 초고층 현장에 적용하기 위한 기본 자료로 활용 하고자 하였다.

  • PDF

Decay Resistance of Fire-Retardant Treated Wood

  • Lee, Hyun-Mi;Yang, Jae-Kyung;Kim, Jong-Man
    • Journal of the Korean Wood Science and Technology
    • /
    • 제32권6호
    • /
    • pp.7-13
    • /
    • 2004
  • In this study, the Korean pine wood (Pinus densiflora Sieb. et Zucc) and Italian poplar wood (Populus euramericana Guinier) was treated with a mixture of monoammonium phosphate (MAP) and boric acid. Their usability as fire retardant and as decay-resistant construction and interior materials were evaluated by testing of chemicals, corrosion rate and absorption rate, weight loss and chemical contents. An experiment was performed to compare treated pine wood and Italian poplar wood. According to the results, Italian poplar wood had higher specific gravity and retention of chemicals than pine wood, and treated wood showed higher decay-resistance than untreated one. Weight loss was less in treated wood than untreated one because the degree of decay was lower in the former than the latter. Corrosion rate and absorption rate met the KS standard for wood preservative performance. The chemical contents analysis was carried out to determine the degree of decay and it was found that the preservative effect of chemical treatment was lower in Italian poplar wood than in pine wood.

Numerical study on fire resistance of cyclically-damaged steel-concrete composite beam-to-column joints

  • Ye, Zhongnan;Heidarpour, Amin;Jiang, Shouchao;Li, Yingchao;Li, Guoqiang
    • Steel and Composite Structures
    • /
    • 제43권5호
    • /
    • pp.673-688
    • /
    • 2022
  • Post-earthquake fire is a major threat since most structures are designed allowing some damage during strong earthquakes, which will expose a more vulnerable structure to post-earthquake fire compared to an intact structure. A series of experimental research on steel-concrete composite beam-to-column joints subjected to fire after cyclic loading has been carried out and a clear reduction of fire resistance due to the partial damage caused by cyclic loading was observed. In this paper, by using ABAQUS a robust finite element model is developed for exploring the performance of steel-concrete composite joints in post-earthquake fire scenarios. After validation of these models with the previously conducted experimental results, a comprehensive numerical analysis is performed, allowing influential parameters affecting the post-earthquake fire behavior of the steel-concrete composite joints to be identified. Specifically, the level of pre-damage induced by cyclic loading is regraded to deteriorate mechanical and thermal properties of concrete, material properties of steel, and thickness of the fire protection layer. It is found that the ultimate temperature of the joint is affected by the load ratio while fire-resistant duration is relevant to the heating rate, both of which change due to the damage induced by the cyclic loading.

굴 패각과 난각을 혼합한 모르타르의 강도 및 내화성능 평가 (Evaluation of Strength and Fire Resistance Performance of Mortar Mixed with Oyster Shell and Egg Shell)

  • 김해나;정의인;김봉주
    • 한국건설순환자원학회논문집
    • /
    • 제11권4호
    • /
    • pp.560-567
    • /
    • 2023
  • 본 연구에서는 달라지는 화재 성상에 대비하기 위한 내화재료 연구의 일환으로 천연 탄산칼슘 재료인 굴 패각과 난각을 각각 잔골재로 치환하여 치환율에 따른 강도 및 내화성능을 평가하여 내화 재료로 사용하기 위한 자료를 제공하고자 하였다. 굴 패각과 난각은 각각 잔골재 대비 10~50 %를 치환하였고, KS 시험방법에 준하여 강도측정 및 간이가열 실험을 진행하였다. OS를 치환한 경우는 ES를 치환한 경우보다 강도가 높게 측정되었지만 이면온도 또한 높게 측정되었다. 이를 통해 폭발성 화재같이 강도성능이 요구되는 곳은 OS를 혼합한 내화보드를 사용하고, 1000 ℃이상의 고온화재 같이 높은 내화성능이 요구되는 곳은 ES를 혼합한 내화보드를 사용하는 등 용도에 맞게 선택할 수 있을 것으로 사료된다.