• Title/Summary/Keyword: fire simulation

Search Result 1,021, Processing Time 0.023 seconds

Examination on Numerical Simulation Using Reduced-scale Model of Theater Fire: Influences of Fire Curtain and Stage Natural Vent (공연장 화재 축소모형을 이용한 전산시뮬레이션 검토: 방화막 및 무대부 자연배출구 영향)

  • Yang, Ji Hyun;Baek, Seon A;Lee, Chi Young;Kim, Duncan
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.37-47
    • /
    • 2019
  • In the present study, the influences of the fire curtain and natural vent in a theater fire were investigated through the numerical simulation of a reduced-scale model of a theater fire using the Fire Dynamics Simulator (FDS). Based on a previous experimental study using the reduced-scale model, the 1/14 reduced-scale model and its conditions were constructed according to the law of similarity with a real-scale theater. Through a series of numerical simulations, the smoke movements were visualized, and the temperatures in the stage and auditorium, mass flow rate of the outflow through natural vent, and time at which smoke started moving toward the auditorium were measured and analyzed. The general trends on the effects of the fire curtain and natural vent during the theater fire predicted by the present numerical simulation were similar to the previous experimental results. For quantitative comparison of the present numerical simulation and previous experimental results, the mean percentage errors of temperatures in the stage and auditorium, and the mass flow rate of outflow through the natural vent were calculated. The present numerical simulation results showed good agreement with previous experimental results with reasonable accuracy.

A study on the improvement plan of fire simulation training for the improvement of fire response ability : Focusing on the fire simulation training of business facility (화재대응능력 향상을 위한 화재모의훈련의 개선방안에 관한 연구 : 업무시설의 화재모의훈련 중심으로)

  • Kim, Bongjun;Ryu, Guhwan
    • Journal of Digital Convergence
    • /
    • v.18 no.9
    • /
    • pp.191-198
    • /
    • 2020
  • In this study, in order to propose an improvement plan for fire simulation training to improve fire response capability, fire simulation training is conducted for three business facilities, and changes according to whether training materials are used and whether the response time for each response stage is reflected in the training evaluation. The response posture and response ability of the training participants were observed and analyzed. As a result of the analysis, it was analyzed that most of the training participants improved their participation in training, response posture, and response ability when the use of training textbooks and response time for each response stage were reflected in the training evaluation. In the event of a fire simulation training, a number of training materials that can similarly implement the fire situation are used to improve and maintain the fire response capabilities (fire notification and fire report, initial extinguishing, and evacuation) of the training participants, and the target time for each response step. The result was that it can be used as a useful index for improving fire response capability and improving fire simulation training in the future and feedback only when quantitative training evaluation is conducted based on this setting.

Simulation of Pool Fire with Two Rooms Using FDS Model (화재분석모델을 이용한 이중격실화재 검증분석)

  • Kim, Bong-Hyun;Bae, Yong-Bum;Ryu, Su-Hyun;Lee, Gong-Hee;Kim, Yun-Il;Moon, Chan-Ki;Park, Jong-Seok
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1332-1337
    • /
    • 2008
  • Fire model shall be verified and validated to reliably predict the consequences of fires within its limitations. This study aims to predict pool fire with two rooms using FDS and to coompare FDS simulation results with PRISME experimental data which can be applicable to the fire of nuclear power plant facility. Four different sizes of grid (0.08m, 0.1m, 0.125m, 0.2m) are used in the simulation and the simulated results of specific quantities such as temperature, chemical composition, heat flux and heat release rate are compared to the experimental data. From this study, the FDS simulation results with the finer grid resolution show better similarity and trend with pool fire experimental data. The sensitivity analysis and the selection of the proper size grid are essential to predict the consequences of pool fire with two rooms reliably.

  • PDF

A Study on Fire Risk Assessment of a EPS room using Fire Simulation (시뮬레이션 분석을 통한 EPS실 화재위험성 평가에 관한 연구)

  • Ham, Eungu;Kim, Dongcheol;Lee, Changwoo
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.4
    • /
    • pp.581-588
    • /
    • 2015
  • This study was conducted by utilizing simulation (FDS6) the fire characteristics of the flammable substances such as cable compartment of a small space in the EPS room type. In the partitioned space of a room EPS supply of oxygen does not facilitate the combustion of the upward-sloping curve, as in a standard fire curve is not observed. Simulation results in a situation where ventilation is limited to the heat release rate and smoke emission characteristics of the fire showed a complex and unstable form a repeating rise and fall. Fire time was longer than the fire load. Change in the smoke emission than the heat release rate is slow, but changes of the overall surface was found to exhibit affinity.

Development of Post-Processor for Fire Simulation (화재 시뮬레이션을 위한 후처리장치 개발)

  • Hur S.;Chang J.;Hur N.
    • Journal of computational fluids engineering
    • /
    • v.7 no.3
    • /
    • pp.27-34
    • /
    • 2002
  • When caught in a fire inside a building or a tunnel the generated smoke is the main cause of the bad visibility, which makes it difficult for a person to find escape route. Therefore of the fire simulation it is required to visualize the simulated results of smoke realistically form a viewpoint of a person caught in a fire. In the present study, developed is a CFD post-processor which can visualize the object through smoke from the results of CFD fire simulation. Examples of some applications of the program are shown in the paper.

The Influence of Forest Fire Simulation on the Properties of Polymer Insulators

  • Lee, Won-Kyo;Choi, In-Hyuk;Lee, Dong-Il;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.5
    • /
    • pp.161-164
    • /
    • 2009
  • Forest fire simulation tests were performed with polymer and porcelain insulators at GOCHANG Power Testing Center. These tests consisted of open flames causing a temperature rise of up to $600{\sim}800^{\circ}C$ measured at the insulator surfaces. Mechanical and electrical characteristics such as the specific mechanical load, the low frequency dry flashover voltage and the impulse flashover voltage were analyzed for the polymer insulators before, during and after the simulation tests and then compared to the porcelain insulators. At the end of the fire simulation tests, there was no detrimental deterioration of any of the insulators. All the insulators passed the KEPCO specification criteria. This study showed that the forest fire simulation had no impact on the polymer insulators.

Effect of the Statistical Droplet Parcel on Numerical Simulation of Sprinkler Spray (스프링클러 분무 해석에 영향을 미치는 통계적액적군집의 영향)

  • Kim, Sung-Chan;Lee, Sang-Woo;Park, Won-Ju
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.363-370
    • /
    • 2008
  • The present study has been performed to investigate the effect of statistical number of droplets on the simulation of the sprinkler spray using fire field model. In order to simulate the sprinkler spray characteristics, the present study uses NIST Fire Dynamics Simulator version 5.2. A group of Lagrangian particle with similar droplet characteristics, such as diameter, velocity, temperature and so on, is represented by parcel concept to decrease the total number of droplets tracked in the simulation. The present study introduces a new parameter to represent the ratio between real number of droplets and computational parcels. The dependency of the number of parcels on the fire suppression characteristics and spray patterns is quantitatively examined for different ratio between the real number of droplets and computational parcels.

  • PDF

Numerical Simulation of Vertical Wall fires II. Propane Fire (수직벽화재의 수치 시뮬레이션 II. 프로판 화재)

  • Park, Woe-Chul;Trouve, Arnaud
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.188-193
    • /
    • 2008
  • Numerical simulation was carried out for a propane fire of mass transfer rate 3g/m^2-s$ on a 1m high vertical wall. The objectives of this study are to confirm the outcomes of evaluation of the simulator through simulation of natural convection, and to compare the results of the wall fire with those of previous studies. It was confirmed that the simulated boundary layer was laminar at C_s=0.2$ while it was turbulent at C_s=0.1$. The z direction velocity showed lack of turbulent mixing as seen in the natural convection case, and the profiles of temperature and velocities were in relatively good agreement with those of experiment and previous simulation. It was found that the air entrainment into the boundary layer was well predicted.

A Study on the Improvement of Urban Fire Simulation on Firebrand Scattering (불티의 성상을 고려한 도시화재 시뮬레이션 개선에 관한 연구)

  • Koo, In-Hyuk;Seo, Dong-Goo;Kim, Bong-Chan;Kwon, Young-Jin
    • Fire Science and Engineering
    • /
    • v.29 no.5
    • /
    • pp.67-72
    • /
    • 2015
  • Korea urbanized rapidly, and overpopulation with high growth of the economy has resulted in decrepit facilities scattered all cities. If there is a strong wind during a fire, the fire is rapidly spread by various factors. Korea cannot build a prediction model for urban fire combustion phenomena because there are no studies that physically explain the suitable flame phenomena for its buildings. This study built a model for the generation of fire brand and includes to scattering, fall, and ignition An experiment was done using the wind tunnel facilities of the Japanese Building Research Institute (BRI). The results were used to explain the behavior of fire brand, and reflected in the fire simulation model.

Development of Post-Processor for Fire Simulation (화재 Simulation을 위한 Post-Processor 개발)

  • Chang J.;Hur N.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2001.05a
    • /
    • pp.155-160
    • /
    • 2001
  • When caught in a fire inside a building or a tunnel the generated smoke is the main cause of the bad visibility, which makes difficult for a person to find escape route. Therefore it is required to visualize the simulated results of smoke realistically from a viewpoint of a person caught in a fire. In the present study, demonstrated is a CFD post-processor which can visualize the objects through smoke from the results of CFD fire simulation.

  • PDF